• Title/Summary/Keyword: Water pollution accident

Search Result 57, Processing Time 0.026 seconds

국내 토양공정법과 산처리 방법의 비교: 최종 pH와 용출률의 관계

  • 이평구;최선규;오창환;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.46-51
    • /
    • 2000
  • Environmental quality regulations are used to establish the maximum permissible concentrations of heavy metals before a site can be deemed to be polluted or contaminated. This paper compares the results obtained by 0.IN HCl extraction and acid extraction method(HNO$_3$+HClO$_4$.HCl). The leaching efficiency of 0.1N HCl extraction is directly proportional to the final pH of leachate, due to the different solubilities of the heavy metals at different pH values, The severe differences between 0.1N HCl-extractable and total metal contents result mainly from the buffering effect of carbonates, present in sediment. samples. Application of sequential extraction experiments to some sediments collected from gully pot in Seoul illustrates a much stronger scavenging effect by Fe and Mn-hydroxides, carbonates and organic phases. As deduced from both sequential extraction and leaching experiments, the relative mobility of heavy metals is found to be: Mn>Zn>>Co>Cd>>Cu>Pb>Cr>Fe, in spite of large differences in heavy metal content and localization. Changes in the physicochemical environments (such as acidification) caused by a traffic accident may result in the severe environmental pollution of heavy metals of surrounding area( surface water and rivers).

  • PDF

Development of Web Based Water Pollution Accident Response Management System in Rivers (Web 기반 하천의 수질오염사고 대응예측시스템 개발)

  • Mun, Hyun-Saing;Kim, Joo-Young;Jang, Joo-Hyung;Ryu, In-Gu;Kim, Kyung-Hyun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.48-48
    • /
    • 2011
  • 우리나라는 최근 4대강 살리기 사업의 보 건설로 인하여 하천의 수리특성이 크게 변화되고 있어 새로운 하천 환경변화가 충분히 반영된 수질오염사고 대응시스템의 구축이 필요하다. 국내 하천의 오염사고는 매년 50여건 발생하고 있으며, 2008년 김천 유화공장 화재로 인한 페놀유출사고는 이동시간의 예측오류로 취 정수장의 사전대응에 상당한 혼란이 발생되어 먹는 물 공급에 상당한 어려움이 발생되었다. 이러한 시점에서 본 연구에서는 하천의 유역환경변화를 반영하고 실시간으로 오염물질의 이동시간과 확산농도를 예측하기 위한 수질오염사고대응예측시스템을 개발하였다. 본 시스템은 평상시 4대강의 본류 및 주요 지방 1 2급 하천에 대해 수리모델을 매일 업데이트하고, 3차원 수리 수질모형인 EFDC의 독성모듈을 개선하여 예측모델로 사용하고 있으며, 최적방제방법을 선정하기 위해 상류 댐, 보, 농업용저수지 방류량 등을 분석할 수 있도록 구성되어 있다. 시스템의 예측결과는 방제기관, 취 정수장 등의 사전대응 능력을 높이는 데 기여할 것이다.

  • PDF

Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류 모니터링용 실시간 무선 원격 감시 시스템)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2729-2731
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. In this paper, results of development about Real-time Wireless Remote Monitoring System for Stray Current of Subway System are presented.

  • PDF

The Buried Type Reference Electrode for Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류의 실시간 무선 원격 감시 시스템용 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2732-2734
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development about the permanent buried type reference electrode($Cu/CuSO_4$) are presented.

  • PDF

The Development of Buried Type Reference Electrode Using Porous Ceramic(${\alpha}-Al_{2}O_{3}$) (다공성 세라믹(${\alpha}-Al_{2}O_{3}$)를 이용한 지중 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.145-147
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development of buried type reference electrode using porous ceramic$({\alpha}-Al_{2}O_{3})$ are presented.

  • PDF

Research on water quality and flow rate measurement by applying GPS electronic Floater standard experimental method when water environmental chemical accidents occur (수환경 화학사고 발생시 GPS 전자부자 표준실험법 적용을 통한 수질-수리 측정에 대한 연구)

  • Lee, Chang Hyun;Nam, Su Han;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.845-853
    • /
    • 2023
  • Recently, along with the increase in chemical accidents, the number of accidents-related disasters has been increasing continuously since 2012, and when looking at the hydrogen fluoride incident which is a representative example of domestic chemical incidents, there is insufficient technology applicable to the incident site. The result was that the damage spread. Therefore, in this paper, we will adapt the water pollution accident response system to a location-based approach, and introduce a measurement method for alternative index tracking using a GPS electronic floater of a location-based index measurement method for real-time response in the water environment when a chemical incident occurs. The research target area is Gumi City, which is the area where the hydrogen fluoride incident occurred, and Gamcheon is selected, and alternative tracking using GPS electronic floater is conducted in the corresponding target area through water quality and flow measurement. As a result, it is possible to measure water quality and flow at the same time in tracker experiments using GPS electronic floater based on the research results, it is believed that using GPS electronic floater will be of great help in disaster response systems for spill incidents in the river.

A CFD Study of Oil Spill Velocity from Hole in the Hull of Oil Tanker (유조선 선체 파공에 따른 원유 유출 유속의 CFD 연구)

  • Choi, Dooyoung;Lee, Jungseop;Paik, Joongcheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.71-71
    • /
    • 2018
  • Sea pollution accidents have been occurred due to the increase of marine ship traffic. Oil spill from the hull hole induced by tanker collision results in the huge sea pollution. Proper and prompt reaction on such oil spill disaster is needed to minimize the damage. Thru-hull emergency wood plug is typically used to manually close small holes, while it is required to develop some mechanical devices for closing large holes in the hull due to huge fluid pressure. Accurate estimation of oil discharge and velocity from such holes are important to develop proper device to control hull hole damage. High resolution CFD modeling investigation on the configurations of hull hole of 7.5 m initial depth and 30 cm diameter, which was observed in the oil spill accident of the Hebei Sprit off the west coast of Korea in 2007, has been carried out to compute the oil spill velocity distribution in terms of flow depth. Friction loss due to the viscous flow and the discharge coefficient of crude oil with specific gravity SG = 0.85 and viscosity of $4-12cP(mPa{\cdot}s)$ at the temperature of $20^{\circ}C-100^{\circ}C$ are presented in terms of Reynolds number based on the results of high-resolution CFD modeling.

  • PDF

A standardized procedure on building spectral library for hazardous chemicals mixed in river flow using hyperspectral image (초분광 영상을 활용한 하천수 혼합 유해화학물질 표준 분광라이브러리 구축 방안)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.845-859
    • /
    • 2020
  • Climate change and recent heat waves have drawn public attention toward other environmental issues, such as water pollution in the form of algal blooms, chemical leaks, and oil spills. Water pollution by the leakage of chemicals may severely affect human health as well as contaminate the air, water, and soil and cause discoloration or death of crops that come in contact with these chemicals. Chemicals that may spill into water streams are often colorless and water-soluble, which makes it difficult to determine whether the water is polluted using the naked eye. When a chemical spill occurs, it is usually detected through a simple contact detection device by installing sensors at locations where leakage is likely to occur. The drawback with the approach using contact detection sensors is that it relies heavily on the skill of field workers. Moreover, these sensors are installed at a limited number of locations, so spill detection is not possible in areas where they are not installed. Recently hyperspectral images have been used to identify land cover and vegetation and to determine water quality by analyzing the inherent spectral characteristics of these materials. While hyperspectral sensors can potentially be used to detect chemical substances, there is currently a lack of research on the detection of chemicals in water streams using hyperspectral sensors. Therefore, this study utilized remote sensing techniques and the latest sensor technology to overcome the limitations of contact detection technology in detecting the leakage of hazardous chemical into aquatic systems. In this study, we aimed to determine whether 18 types of hazardous chemicals could be individually classified using hyperspectral image. To this end, we obtained hyperspectral images of each chemical to establish a spectral library. We expect that future studies will expand the spectral library database for hazardous chemicals and that verification of its application in water streams will be conducted so that it can be applied to real-time monitoring to facilitate rapid detection and response when a chemical spill has occurred.

A comparative study on managing processes of environmental crisis by water contamination : Taegu and Sydney (물 오염에 의한 환경위기의 관리 과정에 관한 비교 연구 : 대구와 시드니)

  • Choi, Byung-Doo
    • Journal of the Korean association of regional geographers
    • /
    • v.7 no.4
    • /
    • pp.120-145
    • /
    • 2001
  • Environmental risk is one of major risks in contemporary society which is often conceptualized in terms of 'risk society'. The crisis which retains such environmental risk can be characterized by 'technical hazards', rather than natural hazards in traditional societies, because of potentiality of technical control over its generation and managing process. Environmental crisis tends to be recurred due to certain limitations of response of both government and civil society. Moreover, it can be argued that generation of environmental crisis and limitations of its managing process are inherent in problematic structures in contemporary society, especially in its 4 basic elements and their characters; that is, capitalist market economy which promotes increasing profits and decreasing cost; bureaucratic representative politics which has brought about concentration of power and evasion of responsibility, instrumental science and technology which leads to blind belief on scientific knowledge and its uncertainty; and finally individualistic way of life with exclusive and passive response to crisis. This paper aims to consider the generation and managing process of environmental crisis in terms of these 4 basic elements, with comparative studies on empirical cases of the water crisis by Phenol pollution in Taegu in 1991 and the water crisis by parasites contamination in Sydney in 1998.

  • PDF

Analysis of Minimum Detectable Activity Concentration of Water Samples and Evaluation of Effective Dose (물 시료의 최소검출가능 농도 분석과 유효선량 평가)

  • Jang, Eun-sung;Kim, Yang-su;Lee, Sun-young;Kim, Jung-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.857-862
    • /
    • 2020
  • In March 2011, a tsunami off Japan caused radioactive material that had seeped into the sea from the Fukushima nuclear accident to flow to the Pacific Ocean, causing pollution to sea life. For a comparative evaluation with the area surrounding the site of a nuclear power plant by the release of radioactive materials, an area 20 to 30 km away from the emergency protection plan area was selected as a comparative point considering weather conditions, population distribution, etc. In addition, the government intends to analyze the minimum detection radiation received by residents around the nuclear power plant and evaluate the effective dose. Analysis of tritium radiation from water samples showed that most of the samples were not detected and that 0.0014 % to 0.777 % of the annual legal standard of 1 mSv for the general public had little effect on the human body. Therefore, the measurement and analysis of water samples around the nuclear power plant site is expected to help relieve anxiety, such as exposure to the general public and neighboring residents due to radiation release.