• Title/Summary/Keyword: Water pollutant

Search Result 1,362, Processing Time 0.026 seconds

Estimation of Pollutant Load Using Genetic-algorithm and Regression Model (유전자 알고리즘과 회귀식을 이용한 오염부하량의 예측)

  • Park, Youn Shik
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • BACKGROUND: Water quality data are collected less frequently than flow data because of the cost to collect and analyze, while water quality data corresponding to flow data are required to compute pollutant loads or to calibrate other hydrology models. Regression models are applicable to interpolate water quality data corresponding to flow data. METHODS AND RESULTS: A regression model was suggested which is capable to consider flow and time variance, and the regression model coefficients were calibrated using various measured water quality data with genetic-algorithm. Both LOADEST and the regression using genetic-algorithm were evaluated by 19 water quality data sets through calibration and validation. The regression model using genetic-algorithm displayed the similar model behaviors to LOADEST. The load estimates by both LOADEST and the regression model using genetic-algorithm indicated that use of a large proportion of water quality data does not necessarily lead to the load estimates with smaller error to measured load. CONCLUSION: Regression models need to be calibrated and validated before they are used to interpolate pollutant loads, as separating water quality data into two data sets for calibration and validation.

Characteristics of Pollutant Loads according to Types of Sources for the Chungju Dam Watershed (충주댐 유역의 오염원에 따른 오염부하량 발생 특성)

  • Kim, Chul-Gyum;Kim, Nam-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.465-472
    • /
    • 2008
  • Soil and Water Assessment Tool (SWAT) model was selected as a tool for assessing the effect of pollutant sources on the total loads from the Chungju Dam upstream watershed. The model was constructed through calibration of parameters related to nitrogen (N) and phosphorus (P), which was based on the runoff and sediment modeling performed in the previous research. Using this, the spatial and temporal pollutant loadings by source type were investigated. Results of this study indicated that in most forested upstream sub-watersheds, pollutant loadings from point sources were very low, and total loadings by point and non-point sources were also insignificant. On the other hand, in #14 sub-watershed including Jecheon city, the loadings by point source were relatively considerable. For the whole watershed, non-point sources accounted for 99% of sediment, 97% of N, and 93% of P loads. And monthly non-point source loadings were concentrated on rainy summer season, while point source loadings of N and P kept nearly constant throughout the year and were high on dry winter season relative to non-point source.

Pollutant Load Characterization with Flow Conditions in Heukcheon Stream (흑천의 유량조건별 오염부하량 특성)

  • Choi, Kyungwan;Lee, Sangwon;Noh, Changwan;Lee, Jaekwan;Lee, Youngjoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.551-557
    • /
    • 2015
  • The TMDL (Total Maximum Daily Load) has been used to determine the water quality target. LDC (Load Duration Curve) based on hydrology has been used to support water quality assessments and development of TMDL. Also FDC (Flow Duration Curve) analysis can be used as a general indicator of hydrologic condition. The LDC is developed by multiplying FDC with the numeric water quality target of the factor for the pollutant of concern. Therefore, this study was to create LDC using the stream flow data and numeric water quality target of BOD and T-P in order to evaluate the pollutant load characterization by flow conditions in Heukcheon stream. When it is to be a high-flows condition, BOD and T-P are necessary to manage. BOD and T-P did not satisfy the numeric water quality target for both seasons (spring and summer). In order to meet the numeric water quality target in Heukcheon stream, management of non point source pollutant is much more important than that of point source pollutant control.

Behavior of Water Quality in Freshwater Lake of Tide Reclaimed Area Using SWMM and WASP5 Models (SWMM과 WASP5모형을 이용한 간척지 담수호의 수질거동 특성 조사)

  • 김선주;김성준;이석호;이준우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.2
    • /
    • pp.148-160
    • /
    • 2002
  • Lake water quality assessment information is useful to anyone involved in lake management, from lakeshore owners to lake associations. 11 provides lake water quality, which can improve how to manage lake resources and how to measure current conditions. It also provides a knowledge base that can be used to protect and restore lakes. SWMM was applied to simulate the discharge and pollutant loads from Boryeong watershed, and WASP5 was applied to analyze the changes of water quality in Boryeong freshwater lake. In each model, the most suitable parameters were calculated through sensitive analysis and some parameters used default data. Simulated in SWMM and measured discharge showed the accuracy of 88.6%. T-N and T-P exceeds the criteria in the simulation of water quality in Boryeong freshwater lake, and control of pollutant loads in the main stream showed the most effective way. Integrated water quality management system was developed to give convenience in the operation of SWMM and WASP5 and data acquisition.

Pollutant Control using the Separation Wall between Stormwater and Sewage in a Combined Sewer System (우오수분리벽을 이용한 합류식 하수관거의 오염물질 제어효과)

  • Lee, Kuang Chun;Choi, Bong Choel;Lim, Bong Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.461-469
    • /
    • 2004
  • This research is to determine the stormwater effects on sewer concentrations by measuring and comparing the flow and pollutant concentrations during dry and rainy periods in the existing BOX type combined sewer pipes. The monitoring was carried out in two sites, which are the Daesachen outfall having PE separation wall in BOX type combined sewer pipes and the Yongunchen outfall not having seperatioin wall. The average flow-weighted BOD concentraion in Yongunchen outfall is 2-fold lower than in Daesachen outfall because of the dilution effect from ravine water. However, the pollutant mass loading is 16 fold higher in Yongunchen outfall than in Daesachen outfall because of more flows. According to the research, the separation wall controls 52% pollutant mass during a storm period (11.5 mm/hr rainfall intensity). Therefore, the Yongunchen combined sewer system (CSS) need separation wall to control and to prevent more pollutant input in stream. In Daesachen area, the maximum sewer flow rate during a storm period measured about 10 fold bigger than average sewer flow during dry periods. Also the concentrations between rainy and dry periods increase approximately 33 fold for BOD and 120 fold for SS. In Yongunchen area, it increases about 9 fold for the maximum flow rate, 18 fold for BOD and 22 fold for SS during a storm. Therefore, the research is concluded that the separation wall between stromwater (or ravine water) and sewage can decrease the dilution effect in CSS and control the pollutant loading.

Determination of Pollutant Unit Loads from Various Transportation Landuses (교통관련 포장지역 비점오염원에서의 오염물질 유출원단위 산정)

  • Lee, So-Young;Lee, Eunju;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.543-549
    • /
    • 2008
  • Human activities and land-use practices are intensely widening the urban areas. High impervious surface areas cover much of urban landscapes and are the primary pollutant sources which can lead to water quality and habitat degradation in its watershed. As the urban areas expand, transportation land-use such as parking lots, roads, service areas, toll-gates in highways and bridges also increase. These land-uses are significant in urban pollution due to high imperviousness rate and vehicular activities. To regulate the environmental impacts and to improve the water quality of rivers and lakes, the Ministry of Environment (MOE) in Korea developed the Total Pollution Load Management System (TPLMS) program. The main objective is to lead the watershed for a low impact development. On a local scale, some urban land surfaces can be emitting more pollution than others. Consequently, in urban areas, the unit loads are commonly employed to estimate total pollutant loadings emitted from various land-uses including residential, commercial, industrial, transportation, open lands such as parks and golf courses, and other developed land like parking areas as a result of development. In this research, unit pollutant loads derived specifically from transportation land-uses (i.e. branched out from urban areas) will be provided. Monitoring was conducted over 56 storm events at nine monitoring locations during three years. Results for the unit pollutant loads of transportation land-use are determined to be $399.5kg/km^2-day$ for TSS, $12.3kg/km^2-day$ for TN and $2.46kg/km^2-day$ for TP. The values are higher than those of urban areas in Korean MOE and US highways. These results can be used by MOE to separate the pollutant unit load of transportation landuses from urban areas.

Modeling Large Scale of Urban Nonpoint Source Pollution using a Geographic Information System (지리정보체계를 이용한 도시 비점원오염의 대축척 모형화)

  • Kim, Kye-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.1 no.1 s.1
    • /
    • pp.171-180
    • /
    • 1993
  • Concern about nonpoint source pollution associated with urban storm water has led to the development of new tools for better water quality planning. This paper presents an application of a geographic information system (GIS) for urban water quality study. The GIS was used to manage land use data for nonpoint source pollution modeling and to aggregate pollutant loadings within various types of geographic units. An empirical water quality model was used to estimate pollutant loadings based primarily on land use. A land use coverage was created by updating an old coverage through interpretation of recent photography. This land use coverage was also used to record all pollutant loadings for each land use polygon. Storm sewer maps were digitized and interpreted to create a coverage of storm sewer basins and sub-basins. By overlaying pollutant loadings with the sewer sub-basin layer, aggregated pollutant loadings for major sewer outfalls were calculated. Based on the loading information, critical areas of excessive pollutant loadings were located and the effectiveness of Best Management Practices (BMPs) to control pollutant loadings were evaluated.

  • PDF

Analysis of Efficiency of Pollution Reduction Scenarios by Flow Regime Using SWAT Model - A case study for Dalcheon Basin - (SWAT 모형을 활용한 유황별 비점오염 저감 효율 분석 - 달천 유역을 대상으로 -)

  • Kim, Soohong;Hong, Jiyeong;Park, Woonji;Kim, Jonggun;Lim, Kyoungjae
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.469-482
    • /
    • 2021
  • The recent climate change and urbanization have seen an increase in runoff and pollutant loads, and consequently significant negative water pollution. The characteristics of the pollutant loads vary among the different flow regime depending on their source and transport mechanism, However, pollutant load reduction based on flow regime perspectives has not been investigated thoroughly. Therefore, it is necessary to analyze the effects of concentration on pollutant load characteristics and reductions from each flow regime to develop efficient pollution management. As non-point pollutants continuously increase due to the increase in impervious area, efficient management is necessary. Therefore, in this study, 1) the characteristics of pollutant sources were analyzed at the Dalcheon Basin, 2) reduction of nonpoint pollution, and 3) reduction efficiency for flow regimes were analyzed. By analyzing the characteristics of the Dalcheon Basin, a reduction efficiency scenario for each pollutant source was constructed. The efficiency analysis showed 0.06% to 5.62% for the living scenario, 0.09 to 24.62% for the livestock scenario, 0.17% to 12.81% for the industry scenario, 9.45% to 38.45% for the land scenario, and 9.8% to 39.2% for the composite scenario. Therefore, various pollution reduction scenarios, taking into account the characteristics of pollutants and flow regime characteristics, can contribute to the development of efficient measurements to improve water quality at various flow regime perspectives in the Dalcheon Basin.

Determination of Focused Control Pollutant Source by Analysis of Pollutant Delivery Characteristics in Unit Watershed Upper Paldang Lake (팔당호 상류의 단위유역별 오염물질 유출특성 분석을 통한 중점관리 오염원 선정)

  • Kim, Dong Woo;Jang, Mi Jeong;Han, Ihn Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.367-377
    • /
    • 2014
  • Paldang lake which is the most important water resource in Korea is classified as a stream type reservoir and water quality of Paldang lake can be significantly influenced by external pollutant source. So this study was aimed to determine focused control BOD and TP sources of each unit watershed upper Paldang lake through analysis of pollutant source distribution and pollutant runoff characteristics. Generated load, discharge load, delivery load and each load density of 11 unit watersheds upper Paldang lake were calculated using data of water quality and flow rate from pollutant sources and 74 small streams. As a result of generated load, discharge load and delivery load of BOD and TP from pollutant sources, the most BOD generated load was taken by livestock with 66% of total BOD discharge load and domestic had the most BOD discharge load, 42.7%. The ratio of delivery load of livestock and domestic was 36.4% and 34.3%, respectively. Livestock occupied high ratio of TP generated load, discharge load and delivery load with 82.5%, 44.4% and 46.7%, respectively. Gyeongan watershed which had high population density showed the highest BOD delivery load density of $14.6kg/km^2/d$ and the highest TP delivery load density with $1.23kg/km^2/d$ was analyzed in Cheongmi watershed including the biggest number of livestock. From these results, management of domestic sewer and livestock excrement was determined as a focused control pollutant source. And intensive management about domestic sewer in Gyeongan stream and livestock excrement in Cheongmi stream is required for water quality improvement of Paldang lake.

Regional Characteristics of Nonpoint Source Pollutant Loads in the Upstream Watersheds of Nakdong River (낙동강 상류유역의 지역별 비점오염부하 특성)

  • Choe, Gyeong-Suk;Son, Seong-Ho
    • KCID journal
    • /
    • v.13 no.2
    • /
    • pp.283-292
    • /
    • 2006
  • The characteristics of nonpoint source pollutant loads in upstream of Nakdong River were studied through analysis of pollutant loads of 10 sub-watersheds divided based on administrative district. The discharge and pollutant concentration of each sub-watershed were collected from Nakdong-River Water Research Institute and Daegu Regional Environmental office, respectively. Pollution items analysed in this study were BOD, T-N and T-P. The delivery loads of the nonpoint source pollutions of each sub-watershed were calculated after analysing the concentration of the pollution of each site. Several points were found from the results. Firstly, in general, city areas including Sangju, Andong showed higher degree of nonpoint pollution than country areas including Cheongsong, Yeongyang. The sub-watersheds located upstream side, such as Yeongju, Bonghwa, Necessarily show better water quality than the sub-watersheds located downstream side, such as Mungyeong, Uiseong. This result indicates that a given pollution condition within the watershed can be more sensitive than location factor to the level of water quality. Secondly, the delivery load and area of watershed were not necessarily correlated in the sense of water quality, while the discharge was shown to be highly correlated to the delively load of pollution. Lastly, sewage and waste caused from population and livestock, as well as landuse factor, were found to significantly contribute to the water pollution. Alternative solutions for controlling pollution source, therefore, should be provided to meet target levels of water quality in these regions.

  • PDF