• 제목/요약/키워드: Water plant

검색결과 6,544건 처리시간 0.037초

토양함수량의 조절에 의한 Glycine max. 인공군업의 성장과 총질소량의 변동에 관하여 (On the Growth and Total Nitrogen Changes of Glycine max. Artificial Plant Communities, Grown in Sandy Loam Soil withe a Controlled Moisture Content)

  • 임양재
    • Journal of Plant Biology
    • /
    • 제14권3호
    • /
    • pp.21-28
    • /
    • 1971
  • Dry matter production, leaf area growth and total nitrogen changes were studied in Glycine max. soybean communities, which were grown in sandy loam soils controlled to provide various moisture levels, i.e., 5-7%(level 1), 8-10%(level 2), 11-13%(level 3), 14-15%(lev디 4), 17-20%(level 5) and 22-24%(level 6). A summary of the results is shown. The maximum dry matter production of leaves, stems and nodules and the maximum leaf area per unit area were at level 5, but the maximum of root dry matter production was at level 4. Total nitrogen content of the soybean plant decreased with growth, but each level of soil moisture content also showed a little difference. Water content of the plant decreased with plant age and soil water deficiency, especially in roots and nodules. Nodule formation increased in proportion to soil moisture content. total nitrogen content of the soil on which the soybeans grew, increased from 0.23% before sowing to 0.30% at 100 days after sowing. It seems that soil water content acts as a linear factor in the elongation or dry weight increase of shoots and roots until increasing to level 5. Considering the pattern of plant growth through analysis of the shoot and root dry weight ratio, or the photosynthetic organ and non-photosynthetic organ dry weight ratio, the asymptote of plant growth at a high soil water content exceeded that at a low soil water content.

  • PDF

해양소수력 건설에 따른 방류수로의 수위 변화 특성 분석 (Water Level Variation Analysis in the Cooling Water Discharge Channel of Power Plant due to Installation of Ocean Small Hydropower Plant)

  • 강금석;김지영;유무성
    • 한국해안·해양공학회논문집
    • /
    • 제21권5호
    • /
    • pp.391-404
    • /
    • 2009
  • 삼천포 화력발전소에서 냉각수로 이용되고 방류되는 해수를 이용한 소수력 발전소를 건설하였다. 본 연구에서는 해양소수력 발전소 건설시 가장 중요한 문제인 기존 화력발전소의 순환수 계통에 미치는 영향을 평가하기 위한 방안으로 배수로 수위의 해양소수력 건설 이전, 건설 중, 건설 이후 해양소수력 운전 상태에서의 변화를 예측한 값과 실제 계측값을 분석하였다. 설계시 일반적으로 이용되는 개수로 수리식에서부터 Flow 3D를 이용하여 3차원적인 수리해석 기법을 이용하는 것까지 다양한 예측을 시도하였고 관측을 통하여 검증하고자 하였다. 예측치와 실제 관측치의 비교 결과, 수위의 전체적인 평균값은 예측치와 관측치가 유사하였지만 수위의 변화 폭은 건설 중과 해양소수력 운전 상태에서 매우 크게 나타났다. 또한, 소수력 건설 이전에는 표준위어식과 Honma식의 예측값이 관측값과 가장 유사하였으나, 소수력 건설 이후에는 HEC-2, HEC-RAS, Flow-3D의 예측값이 실측값과 가까운 결과를 보였다.

상수도 배관망에서의 수질변화에 관한 연구 (수질악화의 영향인자 분석과 잔류염소 모델링) (A study on Water Quality Changes in Distribution System (Factor analysis of deterioration of water quality & Modelling of free chlorine))

  • 이현동;정원식;문숙미
    • 상하수도학회지
    • /
    • 제11권3호
    • /
    • pp.59-66
    • /
    • 1997
  • Although it produces well-treated water in water treatment plant, water quality at the tap can be changed depending on the state of pipes. It is because water quality deteriorates as plant water passes through pipeline networks. Therefore, the improvement of not only water treatment technology but also O & M of water pipelines is required to supply good water to consumers. The purpose of the study was to obtain the basic data of control technology for water quality in pipes through investigating water quality in distribution system. We selected 11 sampling sites and investigated water quality from plant to endpoint of distribution system. we also simulated decreasing tendency of free chlorine through pipeline network. As the result of water quality test, all parameters were below allowable levels, but some parameters had the possibility of being over levels. So there must be more work to set up proper countermeasure for violable parameters.

  • PDF

하수처리수를 이용한 소수력발전소 설계 및 성능예측 (Design and Performance Prediction of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant)

  • 이철형;박완순;김원경;김정연;채규정
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.78-83
    • /
    • 2013
  • A methodology to predict the output performance of small hydro power plant using treated effluent in waste water treatment plant has been studied. Existing waste water treatment plant located in Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. .Based on the models developed in this study, the hydrologic performance characteristics for SHP sites have been analyzed. The results show that the flow duration characteristics of small hydropower plant for waste water treatment plant have quite differences compared with small hydropower plant for the river. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in waste water treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed. It was found that the models developed in this study can be used to decide the design performance of small hydropower plant for waste water treatment plant effectively.

싸리나무에 있어서 수분공급량이 생장에 미치는 영향 (Influence of Different Soil Moisture on the Growth of Lespedeza bicolor)

  • 이호준
    • Journal of Plant Biology
    • /
    • 제18권4호
    • /
    • pp.143-149
    • /
    • 1975
  • For the evaluation of drought resistance of the plant, the growth of Lespedeza bicolor Turcz. var. japonica Nakai was analyzed by the control of water content of soil: 1. The growth of leaf, stem and root showed high value in accordance with the increase of soil water content. 2. The formation of nodule was alos increased as the content of soil water became higher. 3. The highest water content of the plant was shown in the plots of 30 and 40% of water centent in soils and in the middle of the growing period (August-September). 4. The C/F ratio in the early period of the growth(July) was similar in each plot, but showed a higher value as the water centent of soil became higher at the later period(October). 5. The T/R ration increased in early period of the growth as the soil water content became higher, but it was decreased to the value of 1 in each plot.

  • PDF

Digital Governor의 Isolation Mode에 대한 고찰 (The consideration of the Isolation Mode for Digital Governor System)

  • 옥연호;이용길;한철희;곽원구;조승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.776-777
    • /
    • 2011
  • 조속기는 수차발전기의 핵심을 담당하는 두뇌라고 말할 수 있으며, 전력계통의 부하(주파수)가 변할 경우 수차발전기의 회전속도를 정격으로 유지시켜 양질의 전기를 생산하도록 항시 조정되는 역할을 한다. 최근 조속기는 디지털화되어 최적제어 감시 및 보호기능을 수행하고 있으나 문제점도 하나둘씩 나타나고 있는 실정이다. 본 논문에서는 디지털 가버너의 Isolation Mode에 대한 설명과 사고사례를 통해 디지털가버너 운영 시 문제점을 분석, 검토하여 보완하고자 하였으며, 이를 통해 안정적으로 전력공급을 주요 목적으로 하였다.

  • PDF

조력발전용 수차발전기의 기동·정지시스템에 관한 연구 (A Study on Start·Stop System at Water Turbine-Generator for Tidal Power Plant)

  • 오민환;박철원
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.113-118
    • /
    • 2014
  • Tidal power is one of new and renewable energy sources. Tidal power is generated by using the gap in the water level between the water outside and inside the embankment. All tidal power plant in Korea were being operated by import of turn-key from abroad. The know-how and technology which are the most important to build predictive control system has become increasingly difficult to obtain from advanced countries because most of them avoid to transfer, which the domestic development of the control system is needed. In this paper, a study on start stop system at water turbine-generator for tidal power plant at the beginning of development was presented. For improvement the efficiency and develope of core technology of the start stop system, the technique and characteristics of tidal power, modeling, maximum generation calculation method, and optimal control of joint control system in Sihwa tidal power plant were studied.

대규모 해수담수화 플랜트에서의 전처리공정 비용 분석 (Cost comparison of pretreatment processes in large SWRO desalination plant)

  • 김영민;김진호;이상호;이창규;박광덕;최준석
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.555-560
    • /
    • 2013
  • A cost analysis method for pretreament processes of a large scale seawater desalination plant was considered using a cost estimation model, WaTER (Water Treatment Estimation Routine). This model is based on cost functions of U.S. EPA to conduct economic analysis of water treatment facilities. A virtual seawater desalination plant which has pretreatment production capacity of $100,000m^3$ per day was chosen as a model plant. Dual media filtration and microfiltration systems were compared as pretreatment process, and the following reverse osmosis process was modeled. As a result, microfiltration showed a price competitiveness in condition of operating with reverse osmosis process by reducing the loads of water treatment and membrane cleaning despite it's high annual cost.

Soil-Plant-Water Relations and the Importance in Horticultural Crops

  • Myeong, No-Hui
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 2001년도 가을 학술발표논문집
    • /
    • pp.3-19
    • /
    • 2001
  • Where temperature permits plant growth, the existence of plants is controlled chiefly by the water availability. Without water, plants cannot grow, and man and animals cannot survive. With too much water, plant growth is also rather limited due partly to oxygen deficit in root zone (Ro et al., 1995). The objective of this seminar is to discuss the most important aspects of water management in relation to crop production and environmental conservation. (omitted)

  • PDF

양어장 방류수를 이용한 해양소수력발전소 구축에 관한 연구 (Construction of Marine Small Hydro Power Plant using Discharge Water of Fish Farm)

  • 황영철;최영도
    • 한국유체기계학회 논문집
    • /
    • 제16권5호
    • /
    • pp.11-17
    • /
    • 2013
  • This study is aimed to construct a marine small hydro power plant using discharge water of fish farm in Jeju Haengwon-ri. The difference of design methods between marine small hydro power plant and land small hydro power plant is to consider the tides. Moreover, ground condition should be examined because gushout sea water comes out from the ground at high tide in Jeju as the ground of Jeju beach consists of basalt stone. From the field test of the turbine generator after construction of the power plant, output power and efficiency of the turbine generator shows good conformance to the required conditions.