• 제목/요약/키워드: Water meter

검색결과 637건 처리시간 0.036초

인구통계학적 요인 및 원격검침 자료를 활용한 가정용 물 사용패턴 분류 및 물 사용량 예측 연구 (Water consumption forecasting and pattern classification according to demographic factors and automated meter reading)

  • 김기범;박해금;김태현;형진석;구자용
    • 상하수도학회지
    • /
    • 제36권3호
    • /
    • pp.149-165
    • /
    • 2022
  • The water consumption data of individual consumers must be analyzed and forecast to establish an effective water demand management plan. A k-mean cluster model that can monitor water use characteristics based on hourly water consumption data measured using automated meter reading devices and demographic factors is developed in this study. In addition, the quantification model that can estimate the daily water consumption is developed. K-mean cluster analysis based on the four clusters shows that the average silhouette coefficient is 0.63, also the silhouette coefficients of each cluster exceed 0.60, thereby verifying the high reliability of the cluster analysis. Furthermore, the clusters are clearly classified based on water usage and water usage patterns. The correlation coefficients of four quantification models for estimating water consumption exceed 0.74, confirming that the models can accurately simulate the investigated demographic data. The statistical significance of the models is considered reasonable, hence, they are applicable to the actual field. Because the use of automated smart water meters has become increasingly popular in recent year, water consumption has been metered remotely in many areas. The proposed methodology and the results obtained in this study are expected to facilitate improvements in the usability of smart water meters in the future.

밸브 수압측정기의 구조해석 (Structural Analysis of Hydraulic Valve Meter)

  • 이종선
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1447-1452
    • /
    • 2012
  • 산업현장에서 사용되고 있는 기존의 밸브 수압측정기는 압력조절을 수동으로 제어함으로서 정확한 압력측정을 할 수 없는 불편함이 있었다. 이를 개선하기 위하여 기존의 밸브 수압측정기에 대하여 자동설계 프로그램인 CATIA를 활용하여 설계하고 3차원 유한요소 해석코드인 ANSYS를 활용하여 설계된 밸브 수압측정기에 대하여 구조해석을 수행하고 내부압력에 따른 내부누수, 응력, 변형률, 총변형량 등을 구하였다. 이러한 결과는 새로운 밸브 수압측정기를 개발하기 위한 기초자료로 활용할 계획이다.

Post-Chlorination Process Control based on Flow Prediction by Time Series Neural Network in Water Treatment Plant

  • Lee, HoHyun;Shin, GangWook;Hong, SungTaek;Choi, JongWoong;Chun, MyungGeun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제16권3호
    • /
    • pp.197-207
    • /
    • 2016
  • It is very important to maintain a constant chlorine concentration in the post chlorination process, which is the final step in the water treatment process (hereafter WTP) before servicing water to citizens. Even though a flow meter between the filtration basin and clear well must be installed for the post chlorination process, it is not easy to install owing to poor installation conditions. In such a case, a raw water flow meter has been used as an alternative and has led to dosage errors due to detention time. Therefore, the inlet flow to the clear well is estimated by a time series neural network for the plant without a measurement value, a new residual chlorine meter is installed in the inlet of the clear well to decrease the control period, and the proposed modeling and controller to analyze the chlorine concentration change in the well is a neuro fuzzy algorithm and cascade method. The proposed algorithm led to post chlorination and chlorination improvements of 1.75 times and 1.96 times respectively when it was applied to an operating WTP. As a result, a hygienically safer drinking water is supplied with preemptive response for the time delay and inherent characteristics of the disinfection process.

다공 오리피스를 이용한 액체산소 유량측정 (Flow Measurement of Liquid Oxygen using the Multi-hole Orifice)

  • 임하영;이지성;김정한;노용오
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1031-1035
    • /
    • 2017
  • 액체산소의 유량을 측정하기 위해 두 가지 형태의 다공성 오리피스 미터를 제작하여 물을 이용하여 $C_d$를 측정하였다. 다공 오리피스 미터와 코리올리 미터를 직렬로 연결하고 액체산소를 흘려보내는 유동시험을 수행하여 물을 이용하여 구한 $C_d$를 이용하여 질량유량을 산출하였다. 코리올리 미터를 기준으로 할 때 A 형(1/2")의 경우 0.4%, B 형(3/4")의 경우 0.8% 이하의 오차를 확인하였다.

  • PDF

마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I) (A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I))

  • 김철수;김진현
    • Journal of Biosystems Engineering
    • /
    • 제19권2호
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

Performance Analysis of Water-Water Heat Pump System of 100 kW Scale for Cooling Agricultural Facilities

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Biosystems Engineering
    • /
    • 제39권1호
    • /
    • pp.34-38
    • /
    • 2014
  • Purpose: In this study, the performance of cooling system with the water-water heat pump system of 100kW scale made for cooling agricultural facilities, especially for horticultural facilities, was analyzed. It was intended to suggest performance criteria and performance improvement for the effective cooling system. Methods: The measuring instruments consisted of two flow meters, a power meter and thermocouples. An ultrasonic and a magnetic flow meter measured the flow rate of the water, which was equivalent to heat transfer fluid. The power meter measured electric power in kW consumed by the heat pump system. T-type thermocouples measured the temperature of each part of the heat pump system. All of measuring instruments were connected to the recorder to store all the data. Results: When the water temperature supplied into the evaporator of the heat pump system was over $20^{\circ}C$, the cooling Coefficient Of Performance(COP) of the system was higher than 3.0. As the water temperature supplied into the evaporator, gradually, lowered, the cooling COP, also, decreased, linearly. Especially, when the water temperature supplied into the evaporator was lower than $15^{\circ}C$, the cooling COP was lower below 2.5. Conclusions: In order to maintain the cooling COP higher than 3.0, we suggest that the water temperature supplied into evaporator from the thermal storage tank should be maintained above $20^{\circ}C$. Also, stratification in the thermal storage tank should be formed well and the circulating pumps and the pipe lines should be arranged in order for the relative low-temperature water to be stored in the lower part of the thermal storage tank.

미끄럼시험에서 비눗물을 대체하기 위한 SDS 수용액의 적정 혼합비율 도출 (Extraction of Proper Mixture Ratio of SDS Solution as the Substitute of Soapy Water in a Slip Test)

  • 김대규;신윤호;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.83-84
    • /
    • 2016
  • For the slip resistance test of shower room floor, the "O-Y Pull Slip Meter method (O-Y·PSM)" regulated under KS M 3510. This test method uses cooking oil as a substitute of soapy water, and thus it does not reflect the real condition. In this study, on 10 types of floor material samples, the Coefficient of Slip Resistance Bath (CSR·B) on bare foot between 10 types of body wash solution and 6 types of SDS solution was compared. The body wash solution is a mixture of soap and water in 1:20 ratio. As a result, SDS 0.1% solution was the most suitable for a substitute of soapy water in shower.

  • PDF