• Title/Summary/Keyword: Water management treatment system

Search Result 324, Processing Time 0.027 seconds

An Analysis on Removal Effect of Biological Contaminants in the Process of Municipal Sewage Treatment System - On the Seoul Cheonggye Cheon Sewage Treatment Plant (도시하수 처리에 의한 미생물 오염의 제거효과에 관한 조사연구(I) -청계천 하수처리장을 중심으로-)

  • Yu Byong Tae;Chung Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.1 s.4
    • /
    • pp.27-39
    • /
    • 1988
  • This investigation was carried out to evaluate the removal effect of biological contaminants for the municipal sewage treatment process at Cheonggye Cheon terminal plant which in the first plant for municipal sewage treatment in Seoul area. It was conducted in raw influent, primary treatment water and secondary treatment water from September, 1986 to July, 1987. The results were as follow; 1, The primary treatment could eliminate microbials for $65.38\%$ of total bacteria, $64.35\%$ of total coliform, $62.16\%$ of fecal coliform $69.48\%$ of pseudomonas and $64.70\%$ of fecal streptococci in averages for a year respectively. 2. The secondary treatment could eliminate microbials for $97.50\%$ of total bacteria, $97.30\%$of total coliform, $95.95\%$ of fecal coliform, $97.00\%$ of pseudomonas and $96.53\%$ of fecal streptococci in average for a year respectively. 3. In the detect rate of pathogenic agent, salmonella spp was decreased $12.5\%$ to $4.2\%$ in primary treatment and it was not detected in secondary treatment, shigella spp was detected $4.2\%$ in influent water but it was not detected in primary and secondary treatment. 4. In the seasonal variation of treatment effect, the removal of summer was the highest, and the removal of all item in winter was lower than the other seasons. 5. There was significant correlation between water temperature and microbal all items (P<0.05) $NH_3-N$ and Microbal items (P< 0.01) at raw water.

  • PDF

Evaluation of Water Quality Goal and Load Allocation Achievement Ratio in Guem River Total Maximum Daily Loads for the 1st Phase (금강수계 1단계 수질오염총량관리제의 목표수질 및 할당부하량 달성도 평가)

  • Park, Jae Hong;Oh, Seung Young;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.859-865
    • /
    • 2012
  • It is necessary to evaluate performances hitherto carried out in the management of Total Maximum Daily Loads (TMDLs) and to set up direction so that this system can be improved continuously in the future. This study was investigated load allocation achievement ratio, water quality goal achievement ratio and interrelation between water quality goal and load allocation for the first period (2004~2010). Load allocation achievement and BOD water quality goal achievement ratio were 50% and 73% in Guem River Basin, respectively. The main reason for excess of load allocation and shortfall of water quality goal were unfulfilled reduction plan and pollution sources increment. Therefore, it is necessary to develop enhanced pollution sources prediction method and make a list realizable reduction plan. 63% of the unit watershed was not interrelation between water quality goal and load allocation. The reason why water quality goal and load allocation had not correlation were water quality of upper unit watershed, increment of inflow quantity, effluent water quality of wastewater treatment plant affected the unit watershed, increment of inner productivity by algae, water quality deterioration during the specific period, river management flow, etc.

Design of Monitoring System for Integrated Management of On-site Wastewater Treatment Plants and Development of its Operation Program (소규모 현장 오수처리시설의 통합관리를 위한 모니터링 시스템 설계 및 운영 프로그램 개발)

  • Cho, Young-Hyun;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.137-140
    • /
    • 2002
  • The monitoring system for integrated management of on-site wastewater treatment plants(biofilter) was designed and its operation program was developed. In design process, the research on monitoring parameters which will be able to represent condition and operation of the pilot plants was accomplished, and these parameters came to reveal with ORP(Oxidation-Reduction Potential), water level, pump and power on/off. Proposed monitoring system is composed with measurement, control, communication and display device, and PCB(Prototype Circuit Boards) and microcontroller (PIC16F877) technique are applied to its design of control device for performing specific function. also, The operation program of PC setup is developed in order to provide a convenience to the manager.

  • PDF

Research on Advanced Measures for Emergency Response to Water Accidents based on Big-Data (빅데이터 기반 수도사고 위기대응 고도화 방안에 관한 연구)

  • Kim, Ho-sung;Kim, Jong-rip;Kim, Jae-jong;Yoon, Young-min;Kim, Dae-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.317-321
    • /
    • 2022
  • In response to Incheon tap water accident in 2019, the Ministry of Environment has created the "Comprehensive Measures for Water Safety Management" to improve water operation management, provide systematic technical support, and respond to accidents. Accordingly, K-water is making a smart water supply management system for the entire process of tap water. In order to advance the response to water accidents, it is essential to secure the reliability of real-time water operation data such as flow rate, pressure, and water level, and to develop and apply a warning algorithm in advance using big data analysis techniques. In this paper, various statistical techniques are applied using water supply operation data (flow, pressure, water level, etc) to prepare the foundation for the selection of the optimal operating range and advancement of the monitoring and alarm system. In addition, the arrival time is analyzed through cross-correlation analysis of changes in raw water turbidity between the water intake and water treatment plants. The purpose of this paper is to study the model that predicts the raw water turbidity of a water treatment plant by applying raw water turbidity data considering the time delay according to the flow rate change.

  • PDF

Economic Management of River Water Quality by Utilization of Self Purification-An Environmental Resource (환경자원의 자정능력 선용을 통한 경제적 하천 수질관리)

  • Koo, Ja Kong;Lee, Byung Kuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.3
    • /
    • pp.13-21
    • /
    • 1987
  • The object of this study was to evaluate the management alternatives with respect to the attainable water quality and total cost(construction+O & M cost) in order to devise a reasonable water quality management system. Joong Ryang-cheon stream located Seoul, Korea was taken as the study area, and dissolved oxygen concentration as the water quality index. Water quality simulation model QUAL2E and linear programming optimization technique were used for scientific and rational analyses. It was assumed that the improvement of water quality could be obtained by the treatment of major point sources where imaginary treatment plants were constructed. And by this, the relationship between total cost of the treatment plants and the stepwise improvement of water quality was studied. The result showed that 3.5mg/l of DO(=dissolved oxygen) level at best could be attained in Joong Ryang-cheon stream during summer. When the DO standard was set 3.0mg/l in the severely polluted regions, more than 5.0mg/l of DO level can be achieved by the construction of 4 treatment plants. Also, the cost comparisons showed that the uniform treatment method is economically inefficient(\$24.8{\times}10^8$) in comparison with the least cost method(\$22.9{\times}10^8$), and there is little difference between the least cost method and the the zoned treatment method(\$23.0{\times}10^8$) that is regarded as more equitable, which shows the characteristics of this basin.

  • PDF

Performance Evaluation of Combined Sewer Overflow Treatment using Filtration Pilot Device (파일럿 여과장치를 이용한 합류식하수관 월류수 처리성능 평가)

  • Lee, Jun Ho;Shin, Young Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.5
    • /
    • pp.409-417
    • /
    • 2019
  • In this study, a $480m^3/day$ pilot device was constructed through laboratory experiments based on the Ministry of Environment manual. The purpose of this study was to analyze the characteristics of CSO treatment and backwashing characteristics by applying the pilot device to the field. The purpose of this study was to acquire the basic data necessary for the design and operation management of the real scale filtration type non-point pollution control system. The filtration was conducted while maintaining the linear velocity of 20m/hour. The CSO treatment efficiencies of the pilot devices were 0.4-76.1%(mean 49.0 %), SS 51.4-91.6%(mean 77.8%), COD 22.2-59.4% (mean 38.3%) and TP 14.5-52.6%(mean 38.1%),respectively. The correlation coefficient between SS and the turbidity of influent water was 0.90, higher than that of CSO. To operate the treatment system effectively, the turbidity can be easily measured in real time as the monitoring item is the most appropriate because SS is the main target substance of the non-point source. As a result of analyzing the adsorbent treatment characteristics of PP filter material applied to this pilot device, the average particle diameter range of influent was $4.6-40.1{\mu}m$(mean $21.2{\mu}m$) and the treated water was $0.9-24.5{\mu}m$(mean $6.4{\mu}m$), respectively. Particles of approximately 10m or less are leached out, and so it is necessary to compensate for the raw water containing micro particulate matter.

A Study on the Threat Analysis and Risk Assessment of Ship Ballast Water System (선박 평형수 시스템의 위협 분석 및 위험 평가에 관한 연구)

  • Hyoseok Lim;Yonghyun Jo;Wonsuk Choi
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.34 no.5
    • /
    • pp.961-972
    • /
    • 2024
  • As IT and OT systems become integrated into ship operations, the security of propulsion, control, communication, and navigation systems has become increasingly critical. In response, the International Association of Classification Societies (IACS) will enforce cybersecurity requirements starting from July 2024. IACS No. 171 (Recommendations on Incorporating Cyber Risk Management into Safety Management Systems) presents quantitative assessment methods; however, there is room for improvement. This study aims to address these issues by applying the TARA framework, outlined in ISO/SAE 21434 for connected vehicles, to identify attack surfaces and conduct risk assessments of the Ballast Water Treatment System(BWTS), which is crucial for navigational safety. Moreover, the study conducts a comparative analysis of the quantitative risk assessments of IACS No. 171 and the TARA framework, proposing the need for and considerations of a new risk assessment framework, VeTARA, specifically tailored for ships. This research is expected to contribute to the enhancement of cyber risk management in maritime operations.

Early-Year Performance of the Sihwa Constructed Wetland for Stream Water Treatment (하천수 정화를 위한 시화인공습지의 초기 수질 정화능)

  • Kwun, Soon-Kuk;Lee, Kyung-Do;Cho, Young-Hyun;Kim, Song-Bae;Cheon, Gi-Seol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.1
    • /
    • pp.93-102
    • /
    • 2005
  • A prototype surface flow constructed wetland was built in the upstream area of Sihwa reclaimed tidal lands to improve the water quality of Lake Sihwa by treating severely polluted stream water. In this study, we monitored hydrology, macrophyte (Phragmites communis Trin,) growth, and water quality in the Banwol and Donghwa wetlands to evaluate their performance during the initial period after the completion of wetland construction, The average removal efficiency($\%$) in each wetland was relatively low compared with the performance data from the North America Wetland Treatment System Database (NADB), which mainly includes urban sewage-treatment wetlands. However, the average removal rates per unit area ($g/m^{2}/day$) were 0.72, 0.72 and 0.51 (BOD), 2,04, 2.46 and 0.70 (SS), 0.89, 0.43 and 1.09 (TN) and 0.02, 0.02 and 0.02 (TP) in the Banwol and Donghwa wetlands and NADB, respectively. The overall performance of the Banwol and Donghwa wetlands was within the expected range of the wetland system processes contributing the reduction of the pollutant load to Lake Sihwa during the initial period of wetland operation. Considering the low influent concentration, high hydraulic loading rate, and insufficient macrophyte growth since the wetland was constructed, better performance is expected if an improved operational scheme is adopted.

Study on occurrence and management of organic micropollutants in sewer systems (국내·외 하수도시설 미량유기물질의 발생 특성 및 관리체계에 대한 이해)

  • Jeong, Dong-Hwan;Ham, Sang-Yee;Lee, Wonseok;Chung, Hyenmi;Kim, Hyunook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.551-566
    • /
    • 2017
  • As the modern society is rapidly developing and people become affluent in materials, many new chemical compounds in different forms of products (e.g., antibiotics, pesticides, detergents, personal care products and plastic goods) are produced, used, and disposed of to the environments. Some of them are persistently having a harmful impact on the environment and mimicking endocrine properties; in general they are present in the environment at low concentrations, so they are called organic pollutants. These organic micropollutants flow to sewage treatment plants via different routes. In this study, the generation characteristics, exposure pathways, detection levels, and environmental impacts of organic micropollutants were critically reviewed. In addition, currently available risk assessment methods and management systems for the compounds were reviewed. The United States Environmental Protection Agency (US EPA), for example, has monitored organic micropollutants and set the monitoring and management of some of the compounds as a priority. To effectively manage organic micropollutants in sewer systems, therefore, we should first monitor organic micropollutants of potential concern and then make a watch list of specific substances systematically, as described in guidelines on listing water pollutants in industrial wastewater.

Home Bioelectrical Impedance Analysis Management System in Patients With Heart Failure: Rationale and Study Design

  • Min Gyu Kong;Inki Moon;Hye-Sun Seo;Jon Suh;Jah Yeon Choi;Jin Oh Na;Eung Ju Kim
    • International Journal of Heart Failure
    • /
    • v.6 no.1
    • /
    • pp.22-27
    • /
    • 2024
  • Body fluid monitoring and management are essential to control dyspnea and prevent re-hospitalization in patients with chronic heart failure (HF). There are several methods to estimate and monitor patient's volume status, such as symptoms, signs, body weight, and implantable devices. However, these methods might be difficult to use for reasons that are slow to reflect body water change, inaccurate in specific patients' condition, or invasive. Bioelectrical impedance analysis (BIA) is a novel method for body water monitoring in patients with HF, and the value in prognosis has been proven in previous studies. We aim to determine the efficacy and safety of home BIA body water monitoring-guided HF treatment in patients with chronic HF. This multi-center, open-label, randomized control trial will enroll patients with HF who are taking loop diuretics. The home BIA group patients will be monitored for body water using a home BIA device and receive messages regarding their edema status and direction of additional diuretics usage or behavioral changes through the linked application system once weekly. The control group patients will receive the usual HF management. The primary endpoint is the change in N-terminal prohormone of brain natriuretic peptide levels from baseline after 12 weeks. This trial will provide crucial evidence for patient management with a novel home BIA body water monitoring system in patients with HF.