• Title/Summary/Keyword: Water level detection

Search Result 260, Processing Time 0.026 seconds

Detection of Oscillatory Pattern Signals and its Application to the Fault Diagnosis of a Boiler Drum-Level Control System (Oscillatory 파형감지에 의한 보일러 플랜트 드럼수위 제어계통의 고장진단)

  • Kim, Jae-Hwa;Seo, Yeol-Kyu;Jang, Tae-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 1999
  • This paper proposes a new approach of plant fault diagnosis which is based on detecting the characteristic pattern signals and associating them with the corresponding faults. The new approach does not require analytic modeling of the target system but best reflects the expertise embedded in the experienced human operation by mimicking them in a systematic way. This paper intends to illustrate the feasibility of the proposed by developing the algorithms to detect and estimate the typical characteristic pattern signals, I. e., oscillatory patterns, and applying them to the diagnosis of various faults of a 500MW boiler control system including tube rupture, feed-water leak, and controller failure.

  • PDF

Terahertz Spectral Characteristics of Electrolyte Solutions under Different Magnetic Fields

  • Shao, Siyu;Huang, Haiyun;Peng, Bo;Wang, Guoyang;Ye, Ping;Wang, Jiahui;Su, Bo;Cui, Hailin;Zhang, Cunlin
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.337-343
    • /
    • 2022
  • Microfluidic chips are new devices that can manipulate liquids at the micrometer level, and terahertz (THz) time-domain spectroscopy has good applicability in biochemical detection. The combination of these two technologies can shorten the distance between sample and THz wave, reduce THz wave absorption by water, and more effectively analyze the kinetics of biochemical reactions in aqueous solutions. This study investigates the effects of different external magnetic field intensities on the THz transmission characteristics of deionized water, CuSO4, CuCl2, (CH3COO)2Cu, Na2SO4, NaCl, and CH3COONa; the THz spectral intensity of the sample solutions decrease with increasing intensity of the applied magnetic field. Analysis shows that the magnetic field leads to a change in the dipole moment of water molecules in water and electrolyte solutions, which enhances not only the hydrogen-bond networking ability of water but also the hydration around ions in electrolyte solutions, increasing the number of hydrogen bonds. Increasing the intensity of this magnetic field further promotes the hydrogen-bond association between water molecules, weakening the THz transmission intensity of the solution.

Development of a Residue Analysis Method for Metamifop in Paddy Water, Soil, and Rice with HPLC (HPLC를 이용한 농업용수, 논토양, 및 현미 중 metamifop의 잔류분석법 개발)

  • Park, Hee-Woon;Moon, Joon-Kwan
    • The Korean Journal of Pesticide Science
    • /
    • v.21 no.1
    • /
    • pp.68-74
    • /
    • 2017
  • An analytical method for detecting metamifop residue in paddy water, soil, and rice with high performance liquid chromatography (HPLC) was developed. Water was extracted with ethyl acetate before analyzing by HPLC. Soil residues were extracted with acetone under acidic condition and after purifying with $Extrelut^{(R)}$ NT, and silica SPE, the residue was analyzed by HPLC. For residue analysis in rice, the procedure involved extraction with acetone, purification with $Extrelut^{(R)}$ NT, partitioning between acetonitrile/hexane, purification with silica SPE cartridge, and analysis by HPLC. The limit of detection (LOD) was 1.0 ng, limit of quantitation (LOQ) was 3.0 ng, and method limit of quantitation (MLOQ) were 0.001 mg/L for paddy water, 0.01 mg/kg for rice and soil, respectively. Standard calibration curve shows linearity from 0.05 mg/kg to 5.0 mg/kg ($R^2=0.9999$). The recoveries in fortified paddy water were $91.3{\pm}3.5%$ (0.01 mg/L level) and $93.2{\pm}6.3%$ (0.05 mg/L level). The recoveries in fortified paddy soils were $92.5{\pm}4.0%$ (0.1 mg/kg level) and $92.7{\pm}4.0%$ (0.5 mg/kg level) in soil A, while, $102.3{\pm}4.4%$ (0.1 mg/kg level) and $98.9{\pm}7.9%$ (0.5 mg/kg level) in soil B, respectively. The recoveries in fortified rice were $93.0{\pm}6.9%$ (0.1 mg/kg level) and $85.0{\pm}3.5%$ (0.5 mg/kg level). This method was proved to be effective and can be used to determine the metamifop residue in paddy water, paddy soil, and rice.

Community characteristics of early biofilms formed on water distribution pipe materials (수도관 재질에 형성된 초기 생물막 형성 미생물의 군집 특성)

  • Kim, Yeong-Kwan;Park, Sung-Gu;Lee, Dong-Hun;Choi, Sung-Chan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.767-777
    • /
    • 2012
  • Annular Biofilm Reactor (ABR) equipped with coupons of three different pipe materials (STS 304, PVC, PE) was used to generate drinking water biofilm samples. The level of assimilable organic carbon (AOC) during the sample generation period was $37.3{\mu}g/L$, and this level did not seem to be low enough to limit the formation of biofilm in this study. Terminal-restriction fragment length polymorphism (T-RFLP) analyses determined T-RF profile as early as 3 h of exposure on PVC coupons. Average surface roughness ($R_a$) measured by atomic force microscopic analyses was 125.7 nm for PVC, and this value was higher than for STS (71.6 nm) and PE (74.0 nm). However, biofilm formation was faster on STS (6 h) than on PE (12 h), which indicated that surface roughness might not be the only factor that controlled the initiation of biofilm development. Upon detection of the T-RF peaks, richness (S) and diversity indices such as Shannon (H) and Simpson (1/D) demonstrated a rather slow increase until 48 h followed by rapid increase regardless of the pipe materials. Differences of microbial community structures among the biofilm samples were determined based on the cluster analysis using Jaccard coefficients (Sj). Biofilm communities could be divided into two distinct groups according to the exposure time regardless of the pipe materials. First group contained a young (< 48 h) biofilm samples (10 out of 11) but second group contained a mature (${\geq}$ 48 h) samples (11 out of 14). Results suggested that, due to the complexity of biofilm, the targeting of the first group of cluster was crucial for optimizing the management of drinking water distribution systems and controlling microbial growth.

Study on the Water Management to get High Quality of Drinking Water (이상적인 음료수 공급을 위한 수질관리에 관한 연구)

  • 김형석;신현덕;박경석
    • Journal of environmental and Sanitary engineering
    • /
    • v.6 no.1
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

A Pilot Study for Introducing Advanced Water Treatment Facilities at Nakdong River (낙동강수계 고도정수시설 도입을 위한 PILOT 실험 연구)

  • Oh, Se-Won;Choi, Kwong-Ho;Choi, Soo-Il;Son, Seong-Sup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.88-98
    • /
    • 1997
  • To obtain design and operating parameters for advanced water facilities, pilot test consisted of ozonation and GAC filtration was conducted at midstream of Nakdong River. Even though the concentrations were very low, 62 chemicals were detected above $0.005{\mu}g/L$ in raw water. In the preozonation, natural organic matters which could produce THMs and organics such as phenols and amines were effectively removed. The performance of TOC removal of GAC filtration with ozonation was better than GAC filtration alone and adsorption capacity of GAC adsorbers were ranged 3~6mg-TOC/g-carbon. And also the life of GAC adsorber for removing TOC was predicted more than 1 years if ozonation is introduced. This indicates that biological degradation of organics happened in GAC filters. Most organics detected at ppt level were removed below detection limit by GAC filtration with ozonation. These results show that ozonation and GAC filtration are the reliable and safe process for organic contaminants and chlorinated byproducts control at Nakdong River.

  • PDF

An Experimental Study on the Detection Characteristic of Draft Ice by Thermography System (열화상 시스템에 의한 유빙의 탐지특성에 관한 실험적 연구)

  • Cho, Yong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.302-307
    • /
    • 2017
  • Draft ice in polar regions is formed due to sea level changes and various environmental factors cause damage due to collision with offshore plants and ships for resource development. Drift ice in polar regions is a potential source of accidents for offshore plants that perform long-term operations in one place, as well as on the ship. To prevent accidents with drift ice, offshore plants and ships in polar regions use satellite image information and detection radar to detect drift ice. However, the inability to use visible satellite images at night significantly lowers the detection probability by radar for small drift ice. In this study, we used a thermal imaging system which can be operated day and night for the detection of drift ice, and carried out an experimental study on the detection characteristics of drift ice. To examine the night operation of the thermal imaging system, the experimental condition was set and the thermal image was measured according to the measurement angle change. Under this condition, the correlation was analyzed by theoretical calculating the radiant energy of the drift ice and the sea water.

Use of hybrid materials in the trace determination of As(V) from aqueous solutions: An electrochemical study

  • Tiwari, Diwakar;Jamsheera, A.;Zirlianngura, Zirlianngura;Lee, Seung Mok
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.186-192
    • /
    • 2017
  • The carbon paste electrode (CPE) was modified with the pristine bentonite and hybrid material (HDTMA-modified bentonite). The modified-CPEs are then employed as working electrode in an electrochemical detection of As(V) from aqueous solutions using the cyclic voltammetric measurements. Cyclic voltammograms revealed that As(V) showed reversible behavior onto the working electrode. The hybrid material-modified carbon paste electrode showed significantly enhanced electrochemical signal which was then utilized in the low level detection of As(V). Moreover, the studies were conducted at neutral pH conditions. The electrochemical studies were conducted with scan rates (20 to 200 mV/s) to deduce the mechanism of redox processes involved at the electrode surface. The anodic current was linearly increased, increasing the concentration of As(V) from 5.0 to $35.0{\mu}g/g$ using the hybrid material-modified electrode. This provided fairly a good calibration line for As(V) detection. The presence of varied concentrations of As(III) in the determination of total arsenic was studied. The influence of several cations and anions viz., Cu(II), Mn(II), Zn(II), Pb(II), Cd(II), Fe(III), $Cl^-$, $NO_3{^-}$, $PO_4{^{3-}}$, EDTA and glycine in the detection of As(V) from aqueous solution was also studied. Further, in an attempt to simulate the real matrix analysis, the tap water sample was spiked with As(V) and subjected for As(V) detection using the modified-CPE.

Detection of Red Tide Patches using AVHRR and Landsat TM data (AVHRR과 Landsat TM 자료를 이용한 적조 패취 관측)

  • Jeong, Jong-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Detection of red tides by satellite remote sensing can be done either by detecting enhanced level of chlorophyll pigment or by detecting changes in the spectral composition of pixels. Using chlorophyll concentration, however, is not effective currently due to the facts: 1) Chlorophyll-a is a universal pigment of phytoplankton, and 2) no accurate algorithm for chlorophyll in case 2 water is available yet. Here, red band algorithm, classification and PCA (Principal Component Analysis) techniques were applied for detecting patches of Cochlodinium polykrikoides red tides which occurred in Korean waters in 1995. This dinoflagellate species appears dark red due to the characteristic pigments absorbing lights in the blue and green wavelength most effectively. In the satellite image, the brightness of red tide pixels in all the three visible bands were low making the detection difficult. Red band algorithm is not good for detecting the red tide because of reflectance of suspended sediments. For supervised classification, selecting training area was difficult, while unsupervised classification was not effective in delineating the patches from surrounding pixels. On the other hand, PCA gave a good qualitative discrimination on the distribution compared with actual observation.

  • PDF

Determination of Trace Uranium in Human Hair by Nuclear Track Detection Technique

  • Chung, Yong-Sam;Moon, Jong-Hwa;Zinaida En;Cho, Seung-Yeon;Kang, Sang-Hoon;Lee, Jae-Ki
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.225-230
    • /
    • 2001
  • The aim of this study is to describe a usefulness of nuclear analytical technique in assessing and comparing the concentration levels through the analysis of uranium using human hair sample in the field of environment. A fission track detection technique was applied to determine the uranium concentration in human hair. Hair samples were collected from two groups of people - a) workers not dealing with uranium directly, and b) workers possibly contaminated with uranium. The concentration of $^{235}$ U for the first group varied from <1 to 39 ng/g and the second group can be estimated up to the level of $\mu$g/g. Radiographs of heavy-duty work samples contained high dense “hot spots” along a single hair. After washing in acetone and distilled water, external contamination was not totally removed. Insoluble uranium compounds were not completely washed out. The (n, f)- radiography technique, having high sensitivity, and capable of getting information on uranium content at each point of a single hair, is an excellent tool for environmental monitoring.

  • PDF