• 제목/요약/키워드: Water injection

검색결과 1,680건 처리시간 0.03초

Prevention of Oak Wilt by Tree Injection of Culture Suspension of an Antifungal Microorganism, Streptomyces blastmyceticus against Oak Wilt Fungus, Raffaelea quercus-mongolicae

  • Lee, Jin Heung;Hong, A Reum;Yun, Ji Ho;Seo, Sang Tae;Lee, Jong Kyu
    • Journal of Forest and Environmental Science
    • /
    • 제34권5호
    • /
    • pp.376-381
    • /
    • 2018
  • For the control of oak wilt caused by Raffaelea quercus-mongolicae, an antifungal microorganism, Streptomyces blastmyceticus, was used as a potential agent. Culture suspension of S. blastmyceticus was injected into Quercus mongolicae in the research forest of Kangwon National University by $ChemJet^{(R)}$ trunk injection and Macro-infusion at root flare injection. $Alamo^{(R)}$ (a.i., propiconazole 14.5%), a fungicide currently used for the control of oak wilt in USA, was also treated by both methods to compare the efficacy. For preventive efficacy, culture suspension of the pathogen was inoculated at 1 month after injection of either agent. Tested trees were cut at 3 months after treatment, stained with 1% Fuchsin acid, and then non-conductive area (NCA) and re-isolation frequency (RIF) of oak wilt fungus were compared among treatments. While NCA was the highest as 47.3% in pathogen only treatment, it was the lowest as 16.0% in sterilized water treatment by Macro-infusion. NCAs of Alamo treatment by Macro-infusion and ChemJet injection were 25.3% and 32.1%, respectively. NCA of S.blastmyceticus treatment by ChemJet injection was 32.3%, similar with Alamo treatment's by ChemJet injection. All treatments by either injection method showed significantly lower NCA compared to the pathogen only treatment. These results indicate that S. blastmyceticus injection shows the preventive efficacy against oak wilt disease by suppressing the growth of pathogen injected. NCA of Macro-infusion injection of sterilized water was lower as 16.0%, compared to 21.3% of ChemJet injection. It means that Macro-infusion is more effective in translocation of sterilized water than ChemJet injection by even distribution. RIF from wood discs of treated trees showed high in pathogen only treatment, but relatively low in S. blastmyceticus treatment. RIF results were correlated with NCA results. From the above results, it was confirmed that S. blastmyceticus showed preventive efficacy against oak wilt disease by ChemJet trunk or Macro-infusion at root flare injection.

물 분사 펌프의 동특성 분석 (Analysis of Dynamic Characteristics of Water Injection Pump)

  • 이종명;이정훈;하정민;안병현;김원철;최병근
    • 대한기계학회논문집A
    • /
    • 제37권12호
    • /
    • pp.1483-1487
    • /
    • 2013
  • 물 분사 펌프는 심해 유정의 시추작업 후 유정 내 높은 압력으로 인하여 원유를 1 차 생산하고 이후 유정 내 압력이 낮아져 유정 자체의 압력 만으로 생산이 어려울 때 고압의 해수를 유정에 주입해 회수율을 높이는 해양플랜트에서 사용되는 핵심 기자재이며, 여러 기업에서 개발 중이다. 본 논문은 회전체의 동특성 을 분석하여 베어링 강성에 따른 고유진동수 변화분석, 운전속도 변화에 따른 고유진동수의 변화와 위험속도 분석, 안정성 평가, 불평형 응답을 통하여 변위와 틈새 관계 분석 등의 수학적 해석을 통하여 개발 중의 제품의 신뢰성에 기여하였다.

The Effects of Water Mist on the Compartment Fire

  • Ryou, Hong-Sun;Kim, Sung-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권1호
    • /
    • pp.30-36
    • /
    • 2004
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water spray. The predicted temperature fields of smoke layer are compared with those of measured data. Numerical results agree with the experimental results within $10^{\circ}C$ in the case without water mist. In the case of fire suppression with water mist, numerical results do not predict well for temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with those of measured data. The reason for the discrepancy between predicted and measured data is due to the poor combustion modeling during the injection of water mist. More elaborate models for numerical simulation are required for better predictions of the fire suppression characteristics using water mist.

A Verification Study on the Temperature reduction Effect of Water Mist Injection

  • Kim, Jeong-Ho;Lee, Myung-Hun;Yoon, Yong-Han
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.5-14
    • /
    • 2015
  • Purpose: Recently, according to climate changes, human health is exposed to danger over the world and they influence all fields of human society. Due to these climate changes, humans can be exposed to more frequent and extreme scorching heat and cold wave than the present. As precautions against these urban higher temperature and dryness, diverse methods are being sought. Among them, as measures to form cold islands, the evaporative cooling effect realistic to social and economic conditions was examined. Method: This study was conducted to analyze effects of temperature reduction and cooling according to injection quantity of minute water particles by using a blast sprayer as one of alternatives of alleviation of urban climate changes in outside space in summer. For this, through temperature difference in accordance with the injection quantity per hour of a day, a time zone representing the value of the highest temperature change was analyzed. Also, by analyzing temperature difference according to the injection quantity per daytime insolation, relation of amounts of insolation and evaporation was investigated. Temperature difference in accordance with distances at the highest temperature with the highest value in temperature changes was analyzed. Result: At the study result, about temperature, as injection quantity increase, temperature reduction was significant statistically at the highest temperature with the most insolation. A factor with the highest influence was judged to be the increase of the injection quantity. According to the injection quantity, it was predicted that $3.1^{\circ}C$ temperature reduction of a daily average in case of 0.16L/min, $3.5^{\circ}C$ temperature reduction of a daily average in case of 0.32L/min, and $4.4^{\circ}C$ temperature reduction of a daily average in case of 0.48L/min.

압축비가 기관의 방열에 미치는 영향 (Effect of compression ratio on the heat dissipation of engine)

  • 이창식
    • 오토저널
    • /
    • 제5권1호
    • /
    • pp.89-93
    • /
    • 1983
  • This paper describes on experimental investigation into the heat dissipation of Diesel engine, placing emphasis on the variations of compression ratio and cooling water temperature. The engine used for this test was a vertical single-cylinder four-cycle type, having a direct injection. Engine performance and heat transfer rates was tested under the compression ratio 14.3 and 17.4. In this study, the results showed that output and transfer rates of engine decrease in accordance with the decrease of compression ratio. The effect of cooling water temperature and injection delay of fuel on the heat dissipation brings about the decrease of heat transfer rates from cylinder to cooling water.

  • PDF

물분무에 의한 화재제어 특성에 관한 연구 (A Study on the Fire Suppression Characteristics Using a Water Mist)

  • 김성찬;유홍선
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.261-267
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water droplet, droplet evaporation, and combustion of pool fire. The predicted temperature fields of smoke layer are compared with that of measured data. Numerical results agree with the experimental results within 5$^{\circ}C$ in the case without water mist In the case of fire suppression with water mist, numerical results dose not predict well lot temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with that of measured data. The reason of the discrepancy between predicted and measured data is due to the variation of turning rate during the injection of water mist. The effect of burning rate on the fire suppression is left as future study.

토조 및 수치모형을 이용한 개방형 지중 열교환 시스템 모의 (Simulation of Open-Loop Borehole Heat Exchanger System using Sand Tank Experiment and Numerical Model)

  • 이성순;배광옥;이강근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.489-492
    • /
    • 2007
  • Understanding the thermohydraulic processes in the aquifer is necessary for a proper design of the aquifer thermal energy utilization system under given conditions. Experimental and numerical test were accomplished to evaluate the relationship between the geothermal heat exchanger operation and hydrogeological conditions in the open-loop geothermal system. Sand tank experiments were designed to investigate the open-loop geothermal system. Water injection and extract ion system as open-loop borehole heat exchanger was applied to observe the temperature changes in time at injection well, extraction well and ambient groundwater. The thermohydraulic transfer for heat storage was simulated using FEFLOW for two cases of extraction and injection phase operation in sand tank model. As one case, the movement of the thermal plume was simulated with variable locations of injection and extraction well. As another case, the simulation was performed with fixed location of injection and extraction well. The simulation and experimental results showed that the temperature distribution depends highly on the injected water temperature and the length of injection time and the groundwater flow and pumping rate sensitively affect the heat transfer.

  • PDF

Single-dose Intramuscular-injection Toxicology Test of Water-soluble Carthami-flos and Cervi cornu parvum Pharmacopuncture in a Rat Model

  • Park, Sunju;Sun, Seung-Ho
    • 대한약침학회지
    • /
    • 제18권3호
    • /
    • pp.42-48
    • /
    • 2015
  • Objectives: The aim of the study is to investigate both the single-dose intramuscular injection toxicity and the approximate lethal dose of water-soluble Carthami-flos and Cervi cornu parvum pharmacopuncture (WCFC) in male and female Sprague-Dawley (SD) rats. Methods: The study was conducted at Biotoxtech Co. according to the Good Laboratory Practice (GLP) regulation and the toxicity test guidelines of the Ministry of Food and Drug Safety (MFDS) after approval of the Institutional Animal Care and Use Committee. Dosages for the control, high dose, middle dose and low dose groups were 0.5 mL/animal of saline and 0.5, 0.25 and 0.125 mL/animal of WCFC, respectively. WCFC was injected into the muscle of the left femoral region by using a disposable syringe (1 mL, 26 gauge). The general symptoms and mortality were observed 30 minutes, 1, 2, 4, and 6 hours after the first injection and then daily for 14 days after the injection. The body weights of the SD rats were measured on the day of the injection (before injection) and on the third, seventh, and fourteenth days after the injection. Serum biochemical and hematologic tests, necropsy examinations, and histopathologic examinations at the injection site were performed after the observation period. Results: No deaths, abnormal clinical symptoms, or significant weight changes were observed in either male or female SD rats in the control or the test (0.125, 0.25, and 0.5 mL/animal) groups during the observation period. No significant differences in hematology and serum biochemistry and no macroscopic abnormalities at necropsy were found. No abnormal reactions at injection sites were noted on the topical tolerance tests. Conclusion: The results of this single-dose toxicity study show that WCFC is safe, its lethal doses in male and female SD rats being estimated to be higher than 0.5 mL/animal.

메탄 하이드레이트 동적특성에 대한 실험적 연구 (A Experimental Study of the Kinetic Characteristics of Methane Hydrate)

  • 김남진;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.19-25
    • /
    • 2006
  • Methane hydrate, non-polluting new energy resource, satisfies requirement and considered as a precious resource that can prevent the global warming. Fortunately, there are abundant resources of methane hydrate distribute in the earth widely. Therefore, developing the techniques that can utilize these gases effectively is highly desired. The work in this paper here is to develop a skill which can transport and store methane hydrate. As a first step, the equilibrium experiment was carried out by increasing temperatures in the cell at fixed pressures. The influence of gas consumption rates under variable degree of subcooling, stirring and water injection has been investigated formation to clarify kinetic characteristics of the hydrate. The results of present investigation showed that the enhancements of the hydrate formation in terms of the gas/water ratio are closely related to operational pressure, temperature, degrees of subcooling, and water injection.