• Title/Summary/Keyword: Water heater

Search Result 352, Processing Time 0.035 seconds

Effect of Heating by Infrared Heating Lamps on Growth of Strawberry and Heating Cost (적외선 난방등을 이용한 난방이 딸기의 생육과 난방비에 미치는 영향)

  • An, Jae Uk;An, Chul Geon;Hwang, Yeon Hyeon;Yoon, Hae Suk;Chang, Young Ho;Shon, Gil Man;Jeong, Byoung Ryong
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.355-360
    • /
    • 2013
  • Diesel-burning air heater (air heater) and infrared heating lamp (infrared heater) were installed as auxiliary heaters in two single water-curtained plastic greenhouses with a set night temperature of $6^{\circ}C$ for cultivation of strawberry 'Seolhyang'. The average night air temperature was $6.6^{\circ}C$ in the infrared heater treatment and $7.1^{\circ}C$ in the air heater treatment. However, when the minimum outside temperature fell below $-10^{\circ}C$, the air heater had less internal temperature fluctuations. In contrast, the infrared heater had some cases of falling below the set temperature. The relative humidity was higher than 98% by the side-effect of water-curtain system regardless of the heating system. There was about $5^{\circ}C$ difference in leaf temperature between the turned-on and -off state of the infrared heater, and the efficacy of the infrared heater on leaf temperature was only limited to about 4 meters from the system. Peduncle length and plant height in the infrared heater tended to be greater than those in the air heater. There was, however, no statistically difference in leaf size and numbers of leaves, flowers on first cluster and branches. There was no difference in soluble solids content, fruit firmness, average fruit weight of the harvested fruits, and the yield. Comparing the heating costs, the air heater system took 622,662 won based on 543 L tax-free diesel, while the infrared heater system took 235,284 won by consuming 5,685 kWh of electricity, and 62.2% heating costs saving was achieved.

Experimental Study for Consolidation by Electric Heating Systems (전기가열장치를 이용한 압밀촉진에 관한 실험적 연구)

  • Park, Min-Cheol;Im, Eun-Sang;Lee, Kum-Sung;Han, Heui-Soo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.43-53
    • /
    • 2012
  • This study deals with the conventional consolidation methods like preloading and vertical drains. For it, Two different mechanism, i.e., increasing of permeability and evaporating of pore water were studied. The marine clays excavated in Incheon were heated at low temperature($90^{\circ}C$) to increase the permeability. Also, Microwave oven and high-temperature electric heater were used for pore water evaporation. Several points raised from the experiments. To fix them, the electric heating system was revised to upgrade the field application and drain efficiency of pore water, and the marine clays were heated by revised electric heater at high temperature($250^{\circ}C$). From Experimental result showed that results, high-temperature heater induced the pore water evaporation and displayed the excellent consolidation behavior. In addition, the cone index of heated clays were increased about 19 times, which suggested that electric heating system could be applied for ensuring the trafficability of heavy equipments.

A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles (스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구)

  • Jeon, Byungyong;Ko, Wonbin;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.

A Effect Saving Temperature of Instantaneous Heater Using An Economical Bidet Due to Change Silicon-Tube (실리콘 튜브의 변경으로 인한 절전형 비데용 순간 히터 온도 절감 효과)

  • Chung, In-Ryong;Kim, Won-Jong;Nam, Sang-Younk;Lee, Sung-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2057-2058
    • /
    • 2011
  • We have studied that a effect saving temperature of instantaneous heater using an economical bidet due to change Silicon-Tube. The results, we have found that the existing instantaneous heater is reduced 15 [%], 20 [%] better than a new product instantaneous heater as a discharge water [${\ell}$/min] with temperature and ${\nabla}$ value, respectively. Therefore, we have showed that the innovative effect of a working process and the cost reduction because an economical bidet due to change Silicon-Tube.

  • PDF

Performance Characteristics on the Mixed Flow Type Absorption Chiller-Heater (혼합흐름 사이클용 흡수식 냉온수기의 성능특성)

  • Yoon, J.I.;Shin, G.B.;Park, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.351-360
    • /
    • 1996
  • This study focuses on the development and evaluation of the high efficiency absorption chiller-heater, which can be applied to a direct gas fired, double effect system with 40RT (508,000kJ) cooling capacity. The performance of the absorption chiller-heater is investigated through cycle simulation and experiment to obtain the system characteristics with the inlet tenperature of cooling, chilled water, and gas input flow rate. The efficiency of the different cycles has been studied and the simulation and experiment results show that higher coefficient of performance could be obtained for mixed flow cycle. The five percent difference was obtained from the comparison between experimental and cycle simulation results. As a result of this study, the optimum designs were determined based on the operating conditions and the coefficient of performance.

  • PDF

Performance Tests on Parallel Plate Type Solar Air Heater (공기식 평행판형 태양집열기 성능실험)

  • Cha Jong Hee;Song Hi Yul
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.6 no.4
    • /
    • pp.255-261
    • /
    • 1977
  • This study was concerned with the performance of solar air heater using parallel channels. Heat transmission model was developed and fabricated to increase the economic feasibility for solar heating system by using the cheap zinc plate. The prformance was discussed as a function of mass flow rate, and plate, inlet and outlet temperatures. Experimental results show that heat transmission model is sufficient for the analysis of thermal characteristics of air heater and collection efficiency is better than the domestic water heater, as the range 32-49 percent. Collection efficiency in the 2 layers of glass cover is better than that in 1 layer, so it is considered better to use the 2 layers of glass cover during the cold winter season in Korea.

  • PDF

Computational Fluid Dynamics Model for Solar Thermal Storage Tanks with Helical Jacket Heater and Upper Spiral Coil Heater (상부 코일히터를 갖춘 나선재킷형 태양열 축열조의 성능예측을 위한 CFD 해석모델 개발 및 검증)

  • Baek, Seung Man;Zhong, Yiming;Nam, Jin Hyun;Chung, Jae Dong;Hong, Hiki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In a solar domestic hot water (SDHW) system, solar energy is collected using collector panels, transferred to a circulating heat transfer fluid (brine), and eventually stored in a thermal storage tank (TST) as hot water. In this study, a computational fluid dynamics (CFD) model was developed to predict the solar thermal energy storage in a hybrid-type TST equipped with a helical jacket heater (mantle heat exchanger) and an immersed spiral coil heater. The helical jacket heater, which is the brine flow path attached to the side wall of a TST, has advantages including simple system design, low brine flow rate, and enhanced thermal stratification. In addition, the spiral coil heater further enhances the thermal performance and thermal stratification of the TST. The developed model was validated by the good agreement between the CFD results and the experimental results performed with the hybrid-type TST in SDHW settings.

Modeling of a pulse combustion water heater (맥동 연소식 온수기의 모델링)

  • 이관수;김창기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.6
    • /
    • pp.982-990
    • /
    • 1987
  • In previous modeling of Helmholtz-type pulse combustion water heater, muffler and the motion of the flapper valve were omitted. In present work, these have been included in modeling for providing more accurate information regarding the thermal and dynamic behavior of the water heater. In addition, a computer simulation based on the modeling was developed. The comparison of computer predictions with available experimental data shows that the simulation is satisfactory in predicting the nature of operating behavior, amplitudes of the pressure oscillations, and the magnitude of the frequency. But the predicted time-averaged axial temperature of the flue gas along the flue tube length is somewhat below the previous experimental results. The temperature pulsation of the combustion chamber and the velocity pulsation of the flue gas were predicted which have never been measured in previous studies. In particular, the latter is of importance for a valid determination of the heat transfer enhancement due to the gas flow pulsation. Heat transfer results in flue tube were presented and discussed. Also the effects on the installation of the muffler were investigated.

An analytical study on the thermal performance of multi-tube CO2 water heater (다중관형 CO2 급탕열교환기의 열적성능에 대한 해석연구)

  • Chang, Keun Sun;Choi, Youn Sung;Kim, Young-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.23-30
    • /
    • 2016
  • In this study, the heat transfer and pressure drop characteristics were evaluated for multi-tube $CO_2$ water heaters with lengths of 4.5 m and 7.5 m. The evaluation was done using the -NTU method, and the results were compared with experimental data. Water flows through the shell side of the water heater, while $CO_2$ flows through 8 inner tubes. The heater uses a counter-current design to maximize the heat transfer efficiency. The energy balance equation describing the flows of $CO_2$ and water for each node is set up using the section-by-section method. The calculated heat transfer rates agree well with the experimental data within ${\pm}5%$ error. The outlet water temperature decreased linearly with the increase of the water flow rate. The calculated heat transfer rates agreed well with the experimental data within ${\pm}3%$ error. The results show that the heat transfer rate increases almost linearly with the increase of water flow rate or $CO_2$ inlet temperature in both the 4.5-m and 7.5-m water heaters, whereas the water outlet temperature linearly decreases with the increase of the water flow rate. The comparison of the $CO_2$ pressure drop between the calculation and experiment results shows good agreement at the high $CO_2$ flow rate within 5 % error, but the value is about 20 % higher in the experimental pressure drop at the low $CO_2$ flow rate.

A Study on Turbine Auxiliary Devices in a Thermal Power Plant (화력발전소 터빈 보조기기 제어 관한 고찰)

  • Jeong, Chang-Ki;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1667-1668
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Turbine auxiliary devices such as condenser, deaerator, feed water heater, gland steam condenser, pump recirculation equipment, feed water pump, and so on should be operated well so that the steam turbine exert its maximum efficiency. There are many control loop such as hot well level and condenser recirculation, deaerator level, pegging steam pressure, feed water heater level, feed water pump recirculation. In this paper condenser level control and deaerator level control are going to be described.

  • PDF