• 제목/요약/키워드: Water heater

검색결과 352건 처리시간 0.031초

맥동 연소식 열교환기의 열적 및 동적 특성에 관한 해석 (A Study on the Thermal and Dynamic Behavior of the Single Combustion Chamber Pulse Burner)

  • 이관수
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.810-820
    • /
    • 1985
  • 배기 decoupling chamber룰 갖고 있는 맥동 연소 급수가열기에 대한 수학적인 모델링과 관련된 컴퓨터 시뮬레이션을 하였고, 이 때 계에 대한 맥동 현상과 관련된 열적 및 동적 특성을 고려 였다. 시뮬레이션결과 시동기간에 대한 계의 각 부분에서 일어나는 열전달, 압력 및 온도를 구 였고 또한 해석의 제한성과 개선의 필요성을 논의하였다. 이 연구에서 얻어진 결과는 도관에서 맥동에 의한 대류열전달을 예측하기 위한 모델을 세우는데 활용될 수 있다.

SPM의 동적해석 S/W 개발 (Development of SPM Dynamic Analysis Software)

  • 이문성;김진석;조철희;홍성근;정광식
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.84-89
    • /
    • 2000
  • Thermal simulation of typical stack-type and newly proposed planar-type micro-gas sensors were studied by FEM method. The thermal analyses for the proposed planar structure including temperatur distribution over the sensing layer and power consumption of the heater were carried using finite element method by computer simulation and well compared with those of typical stack-type micro-gas sensor. The thermal properties of the microsensor from thermal simulation were compared with those of a actual device to investigate the acceptability of the computer simulation.

  • PDF

온풍난방기의 배기열을 이용한 지중난방용 온수시스템 개발 (Underground hot water heating system development using exhaust gas heat in the hot air heater)

  • 김영중;이건중;신정웅;유영선;장진택
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1999년도 학술발표논문집
    • /
    • pp.100-103
    • /
    • 1999
  • 온풍난방은 우리 나라 대부분의 온실난방지역에서 가장 많이 채택하고 있는 온실난방방법으로 간주되고 있다. 온풍난방은 기본적으로 화석연료를 연소열로 변환시켜 온실난방에 사용하는 방법으로 온수난방, 태양열난방 보다 열효율이 높다. 가장 보편적 온실난방열원으로는 경유나 보일러등유를 연소실에서 연소하여 열교환기를 거친 후 온풍기의 상부에 부착되어 있는 송풍팬으로 강제적으로 온실 내로 온풍을 불어넣는다. (중략)

  • PDF

태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능 (Thermal Performance of Solar Cooling & Hot-water System According to Control Condition)

  • 이호;주홍진;김상진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF

새로운 건성 및 습성 침착 채취기의 개발 (Development of the Novel Dry and Wet Deposition Collector)

  • 이병규;이채복
    • 한국대기환경학회지
    • /
    • 제16권6호
    • /
    • pp.675-684
    • /
    • 2000
  • A novel dry and wet deposition collector, which can overcome the several problems such as water evaporation cartridge cracks and high costs founded in the previous collector systems, has been constructed. ENVI-18 SPE adsorption cartridge has been used to measure atmospheric deposition of polycylic aromatic hydrocarbons (PAHs). A surrogate surface, consisted of water and methanol, was filled in the dry deposition funnel to simulate dry deposition onto water surface. A water supply system in order to compensat evaporation of the surrogate surface was used and it was consisted of a piston pump, a tubing pump, a overflow tube and a chamber system. A novel water vaporizing system to supply water onto the wet SPE cartridge system with a constant flow rate was developed. The novel water vaporizing system, consisted of a vacuum pump, a water supply reserviour and tube and a mini space heater, could prevent the PAHs adsorption cartridge cracks occurred in the previous collector and effectively adsorb PAHs. The novel dry and wet deposition collector showed a good adsorption, desorption, and recovery rates of PAHs. By reducing the number of pumps used and employing polypyopylene (PP) instead of teflon as a material of collection funnel, the total construction costs were much reduced as compared with the previous dry and wet deposition collectors.

  • PDF

스위스 Grimsel Test Site에서 수행된 FEBEX 현장시험에 대한 수치해석적 연구 (Numerical analysis of FEBEX at Grimsel Test Site in Switzerland)

  • 이창수;이재원;김건영
    • 터널과지하공간
    • /
    • 제30권4호
    • /
    • pp.359-381
    • /
    • 2020
  • 벤토나이트 완충재에서의 열-수리-역학적 복합거동을 예측하기 위해 TOUGH2-MP/FLAC3D 시뮬레이터를 기반으로 개발된 Barcelona basic 모델(BBM) 해석모듈의 현장 적용성을 검토하고자 국제공동연구 DECOVALEX-2019 Task D에 참여하여 스위스 Grimsel Test Site의 현장시험(full-scale engineered barriers experiment, FEBEX) 모델링을 수행하고 현장시험에서 계측된 히터 파워, 온도, 상대습도, 응력, 포화도, 함수율 그리고 건조밀도를 계산 값과 비교하였다. 수치해석을 이용하여 시간에 따른 히터 파워와 온도 변화는 전반적으로 잘 재현되었지만, 히터 1과 히터 2에서의 파워 차이를 계산할 수는 없었으며 이를 개선하기 위해서는 FEBEX 터널 주변에 분포하는 황반암과 시험장치 및 벤토나이트 블록의 설치 공정을 반영할 필요가 있을 것으로 판단된다. 상대습도 변화와 분포 역시 전반적으로 잘 모사되었으나, 수치해석에서 히터 부근에서의 재포화과정이 상대적으로 빠르게 진행된 것으로 보아 수리모델에 대한 일부 수정이 필요할 것으로 보인다. 현장시험에서는 벤토나이트 완충재와 암반 사이에 틈이 존재하지만 수치해석에서는 완벽하게 접촉하고 있는 것으로 가정하였기 때문에 운영 초기의 응력 변화는 다소 차이를 보였지만, 전반적으로 유사한 경향을 보이는 것으로 나타났다. 해체 이후 측정한 포화도, 함수율, 그리고 건조밀도의 분포 역시 전반적으로 잘 재현되었지만, 건조밀도가 터널 중심과 히터부근에서 조금 크게 계산되어 벤토나이트 블록의 투수계수가 상대적으로 작은 값으로 반영되어 포화도와 함수율이 작게 계산된 것으로 보이며, 이를 개선하기 위해서는 건조밀도에 따른 투수계수 모델에 일부 수정이 필요할 것으로 판단된다. 본 연구의 결과를 토대로 수치모델을 수정하고 추가적인 연구를 수행한다면, 보다 나은 해석 결과와 벤토나이트 완충재에서의 THM 복합거동을 좀 더 현실적으로 예측할 수 있을 것으로 판단된다.

평판집열기(平板集熱機)를 이용(利用)한 고추 건조(乾燥)에 관(關)한 연구(硏究) (Red Pepper (Capsicum annum) Drying Using Flat-Plate Solar Collectors)

  • 김동만;김만수;장규섭
    • 농업과학연구
    • /
    • 제6권1호
    • /
    • pp.56-64
    • /
    • 1979
  • 고추 건조(乾燥)의 열원(熱源)으로 태양(太陽)에너지를 이용(利用)하기 위(爲)하여 가격(價格)이 저렴(低廉)한 두 종류(種類)의 평판집열장치(平板集熱裝置)를 설계제작(設計製作)하였으며 이의 이용(利用)에 따른 기본적(基本的)인 요소(要素)들을 분석(分析) 검토(檢討)하였고, 고추의 형태(形態)에 따라 건조시험(乾燥試驗)을 수행(遂行)한바 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 대전지방(大田地方)에서의 집열기(集熱機)의 적정경사각(滴定傾斜角)은 1년(年)에 2번 조정(調整)할 경우, 하절기(夏節期)에는 약(約) ${\phi}-15^{\circ}$이고 동절기(冬節期)에는 약(約) ${\phi}+15^{\circ}$였다. 1년중(年中) 직달방향계수(直達方向係數)(Rb)는 집열기(集熱機)의 경사각(傾斜角) $33^{\circ}$에서 4월(月) 16일(日)부터 8월(月) 27일(日)까지를 제외(除外)하고는 1이상(以上)이었다. 2. 시험기간중(試驗期間中)의 외기(外氣) 및 각건조실(各乾燥室)의 조건(條件)은 외기(外氣)의 평균(平均) 온습도(溫濕度)가 $25.6^{\circ}C$, 52.6%RH, 대비건조실(對比乾燥室)이 $42.0^{\circ}C$, 74.2%RH였으며, 물가열식(加熱式)에서 가장 높았고 상대습도(相對濕度)는 공기가열(空氣加熱) 건조실(乾燥室)이 가장 낮았다. 3. 고추 건조(乾燥)에서 건조속도(乾燥速度)는 통고추는 물가열식(加熱式)이 2.3배(培)로 가장 빨랐고 다음이 공기가열식(空氣加熱式), 대비구(對比區) 천일노천구(天日露天區)의 순서(順序)였다. 가장 빠른 건조방법(乾燥方法)은 고추를 수평(水平)으로 절단(切斷)하여 물가열식(加熱式) 건조실(乾燥室)에서 건조(乾燥)시켰을 때였다. 4. 고추의 신미성분(辛味成分)인 capsaicine과 적색소(赤色素)인 capsanthine 함량(含量)은 건조과정중(乾燥過程中)에 약간 감소(減少)하였으나 건조제품(乾燥製品)의 질(質)에 영향(影響)을 미치는 정도(程度)가 아니었으며 건조처리별(乾燥處理別)로도 큰 차이(差異)를 보여 주지 않았다.

  • PDF