• 제목/요약/키워드: Water heater

검색결과 352건 처리시간 0.026초

심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석 (Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater)

  • 정훈;황성욱;이철희
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

실증연구를 위한 주택용 태양열 온수기 모니터링 시스템 개발 (The Development of monitoring system for demonstration research of solar hot water heater for dwellings)

  • 양동조;김재열;한재호;송경석;김우진
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.156-161
    • /
    • 2004
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

수치적 모델링을 통한 이산화탄소 급탕기의 특성 연구 (Studies on Performance of CO2 Water Heater by Numerical Modeling)

  • 박한빛;윤린
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.20-27
    • /
    • 2013
  • Numerical modeling of $CO_2$ water heater was conducted prior to optimal design of medium and large sized $CO_2$ water heater, and the experimental test with small sized $CO_2$ water heater having heat capacity of 4 kW was completed to verify the present numerical model. The present model estimated the experimental data of COP(coefficient of performance), heating capacity, and the hot water outlet temperature within the range of 3% to 8% of mean deviation. As increase of EEV(electric expansion valve) opening area, decreasing of heating capacity and the hot water outlet temperature, and increasing of COP were found in both experimental and numerical investigation.

시즈히터의 화재위험성에 관한 실험 연구 (An experimental study on the fire hazard of Sheath Heater)

  • Kim, Hakjoong
    • 한국재난정보학회 논문집
    • /
    • 제10권4호
    • /
    • pp.511-517
    • /
    • 2014
  • 최근 매년 겨울철이면 온수용으로 사용 중인 시즈히터에 의한 화재가 빈번하게 발생하고 있다. 시즈히터는 구조가 간단하여 비교적 간단한 장치로 온수를 얻을 수 있기 때문에 그 사용이 지속해서 증가하고 있다. 본 연구에서는 온수용 시즈히터에 의한 화재 발생을 감소시키는 방안을 마련하기 위하여 실험을 통하여 화재 발생 메커니즘을 파악함으로써 화재의 위험요인을 발견하고자 한다. 온수용 시즈히터의 화재위험요인에 대한 분석을 위하여 시중에 시판 중인 온수용 시즈히터를 종류별로 구매하여 가열에 따른 온도변화와 발화 실험을 하였다. 실험결과 온수용 시즈히터는 화재가 발생할 위험이 아주 큰 기기이며, 온수용 시즈히터에 설치된 온도조절기는 과열을 방지하기 위한 장치의 역할을 제대로 수행하지 못하고 있음을 확인하였다. 시즈히터에 의한 화재는 발열부의 과열이 주요 원인으로 물의 양과 가장 밀접한 관계를 가지고 있기 때문에 물이 증발하거나, 사용자의 부주의로 물을 사용 후 보충하지 않아 수위가 내려갈 때에 이를 감지 할 수 있는 수위감지장치와 발열부가 과열되는 경우 전원을 차단할 수 있는 발열부 온도제어 장치가 설치되어야 한다.

히트펌프 온수기 개발을 위한 계측 및 성능평가시스템 구축 (Development of Measurement and Performance Testing System for Heat Pump water Heater)

  • 권성철;양승권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2310-2312
    • /
    • 2004
  • In Korea Electric Power Corporation (or KEPCO), several Demand-Side Management (or DSM) program have been carried out to effectively meet electric power demand at least costs by modifying customers electricity use patterns. As one of them, KEPCO applies low-priced night thermal-storage power service for heat appliances to facilitate efficient use of power facilities by shifting relatively high daytime demands to night hours to build loads during the off-peak periods. In the market of heat-storage type water-heater, electric water-heater has been mostly used, but it has low energy efficiency and needs high capacity electric equipments. So in order to replace these electric water heaters, 15 HP air-source heat pump water heater is developed in Korea Electric Research Institute (or KEPRI). This paper shows that measurement system for performance testing of heat pump water heater is established and heating capacity and performance is analyzed and measured for out-door environmental change.

  • PDF

열펌프 가열식 온수기의 동적특성 해석 (Numerical Simulation on Dynamic Characteristics of a Water Heater System Driven by a Heat Pump)

  • 김민성;김민수;백남춘
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.10-20
    • /
    • 2002
  • A dynamic model of a water heater system heated by a heat pump was developed. The water heater system was composed of heat pump and hot water reservoirs. Finite volume method (FVM) was applied to describe the heat exchangers. A new constraint on electronic expansion valve (EEV) or thermostatic expansion valve (TXV) that can control superheat after the evaporator was developed. Dynamic performances were evaluated for various sizes of the reservoir. In order to compare those performances, time scale was normalized by time constant representing the characteristics of reservoir size. Time constant was determined from quasi steady-state simulation of the system. From the simulation, the size of the water heater reservoir was found to have a large influence on the transient performance of the sys- tem. Therefore, the optimization of the reservoir size is needed in a design process.

태양열 온수기 성능평가 위한 모니터링 시스템 개발 (The Development of Monitoring System for Performance Evaluation of Solar Hot Water Heater)

  • 김재열;최승현;양동조
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.417-417
    • /
    • 2009
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

태양열 온수기를 이용한 다목적 공조시스템의 재생효율에 관한 연구(제1보 액체흡수제 온도가 재생량에 미치는 영향) (Research on the Performance of Regenerator using Hot Water from Solar Water Heater(1st paper : On the Effect of Solution Temperature to Regeneration Rate))

  • 우종수;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제24권1호
    • /
    • pp.53-61
    • /
    • 2004
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an efficient solar water heater, this study examines a regeneration process using hot water obtained from solar water heater to recover absorption potential by evaporating moisture in the liquid desiccant. In this paper, a solar absorption dehumidifying system with solar water heater is suggested to save the electricity for operating an air conditioner. LiGl(lithium chloride) solution was adopted as a liquid desiccant in the proposed system, and hot water obtained from the solar water heater was used for regenerating the liquid desiccant. As a result, it was clear that the dilute LiCl solution could be regenerated by hot water, and the regeneration rate depends mostly on temperature level of liquid desiccant. The regeneration rates were about 2.4kg/h with $40^{\circ}C$, 4.0kg/h with $50^{\circ}C$, and 6.2kg/h with $60^{\circ}C$ of hot water respectively.

중형 이산화탄소 급탕기의 최적 설계 (Optimum Design of Middle-Sized CO2 Water Heater)

  • 박한빛;윤린;김영득
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.173-179
    • /
    • 2013
  • Middle-sized $CO_2$ water heater having compressor power of 7.45 kW was designed, and its performances were experimentally tested. Besides, optimum design of the $CO_2$ water heater was conducted by cycle simulation. When ambient temperature of $7^{\circ}C$ and hot water outlet temperature of $80^{\circ}C$ the $CO_2$ water heater showed the COP of 3.2. As hot water temperature increased the COP is getting decreased due to significant increase of compressor power consumption compared to increasing rate of heating capacity. When ambient temperature increased from $-3^{\circ}C$ to $12^{\circ}C$ the COP increased by 30%. The optimum components design of a gas cooler, an internal heat exchanger, and an evaporator were conducted, and the experimental correlation between amount of EEV opening and ambient temperature, and hot water temperature was suggested.

복합형 태양열 가열기에서 열매체 단일운전에 따른 기기성능 평가 (Performance Estimation of Hybrid Solar Air-Water Heater on Single Working of Heating Medium)

  • 최휘웅;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.49-56
    • /
    • 2014
  • Research about hybrid solar air-water heater that can make heated air and hot water was conducted as a part of improving efficiency of solar thermal energy. At this experiment, ability of making heating air and hot water was investigated and compared with traditional solar air heater and flat plate solar collector for hot water when air or liquid was heated respectively. Comparing hybrid solar air-water heater that used in this experiment to other solar air heater studied already, it has a lower efficiency at same mass flow rate. Air channel structure, fin's shape and arrangement in the air channel result in these difference then the ability of air heating need to be improved with changing these thing. In case of making hot water, performance was shown as similar with traditional system although the air channels were established beneath absorbing plate. But the heat loss coefficient was shown higher value by installing of air channel. Also the performance of hot water making was shown lower value at same liquid mass flow rate with traditional flat plate solar collector for hot water. So the necessity of performance improvement at lower mass flow rate of each heating medium can be confirmed.