• Title/Summary/Keyword: Water hazards

Search Result 257, Processing Time 0.025 seconds

Multivariate assessment of the occurrence of compound Hazards at the pan-Asian region

  • Davy Jean Abella;Kuk-Hyun Ahn
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.166-166
    • /
    • 2023
  • Compound hazards (CHs) are two or more extreme climate events combined which occur simultaneously in the same region at the same time. Compared to individual hazards, the combination of hazards that cause CHs can result in greater economic losses and deaths. While several extreme climate events have been recorded across Asia for the past decades, many studies have only focused on a single hazard. In this study, we assess the spatiotemporal pattern of dry compound hazards which includes drought, heatwave, fire and wind across Asia for the last 42 years (1980-2021) using the historical data from ERA5 Reanalysis dataset. We utilize a daily spatial data of each climate event to assess the occurrence of such compound hazards on a daily basis. Heatwave, fire and wind hazard occurrences are analyzed using daily percentile-based thresholds while a pre-defined threshold for SPI is applied for drought occurrence. Then, the occurrence of each type of compound hazard is taken from overlapping the map of daily occurrences of a single hazard. Lastly, a multivariate assessment are conducted to quantify the occurrence frequency, hotspots and trends of each type of compound hazard across Asia. By conducting a multivariate analysis of the occurrence of these compound hazards, we identify the relationships and interactions in dry compound hazards including droughts, heatwaves, fires, and winds, ultimately leading to better-informed decisions and strategies in the natural risk management.

  • PDF

A study on the application of water safety plans for the hazard risk management of tap water (수돗물 위해요소 리스크 관리를 위한 물안전계획 적용 연구)

  • Kim, Jinkeun;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.259-268
    • /
    • 2019
  • One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.

DISTRIBUTION AND SCOPE ANALYSIS OF SOIL AND WATER POLLUTION CONTAMINANT AT ABANDONED METALLIFEROUS MINES USING GIS

  • Kim, Jung-A;Yoon, Suk-Ho;Choi, Jong-Kuk;Kim, Won-Kyun
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.721-724
    • /
    • 2006
  • Among many sources of soil and water pollution, former mining regions also play an important role in distribution and scope of pollution. In response, KMRC has made an investigation into the status mine hazard at the abandoned metalliferous mine area in Korea. In this study, we analyzed distribution of mine hazards at abandoned metalliferous mines using GIS. We considered the distribution of mine hazards and its magnitude for each abandoned mine and displayed the mine hazard index (MHI) using GIS. We divided the MHI value for each mine into 5 classes, and displayed the first class as smallest point symbol and the last class as biggest point symbol. The biggest symbol shows the most serious status of mine hazards. This GIS function was included in the AMGIS system KMRS are running, and it would be helpful to make decision of reclamation priority at abandoned metalliferous mine area.

  • PDF

Consideration for the Highest Temperature Point Movement of the Dongrae Thermal Water in the Pusan Area. (Poster)

  • Kim Tong-Kwon;Lee Jin-Soo;Lee Seung-Gu;Song Yoon-Ho;Kim Tack-Hyun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.10a
    • /
    • pp.158-159
    • /
    • 2005
  • This study showed that the highest temperature point of the Dongrae thermal spring in Pusan was moved to the north direction of the Dongrae fault as times goes by. The Br concentration(1.5mg/L) in Dongrae thermal waters indicated the influence of 2% seawater mixing. If the simple mixing without hydrochemical reaction occurs between seawater and thermal water, the concentration of Mg will be about 20mg/L. But the low concentration(0.1 mg/L) of Mg, contrary to high concentration(10 mg/L) of surrounding groundwater not affected by thermal water, suggested the thermal water, seawater and rock interactions. The calculation of saturation index(SI) by using the geochemical code of EQ3NR showed that the Mg in thermal groundwater, which was introduced by seawater, was removed by the precipitation of Antigorite (SI: log Q/K =71.753, $Mg_{48}Si_{24}O_{85}(OH)_{62}$) and Tremolite (SI: 8.463, $Ca_2Mg_5Si_8O_{22}(OH)_2$), Talc (SI: 6.409, $Mg_3Si_4O_{10}(OH)_2$), Dolomite (SI: 2.014, $CaMg(CO_3)_2$), Chrysotile (SI: 3.698, $Mg_3Si_2O_5(OH)_4$) in the crack of fault zone. The highest temperature point in the study area will move to north direction and stop in the Jangjun area without the input of seawater.

  • PDF

Generation Characteristics and Prediction of Acid Rock Drainage(ARD) of Road Cut Slopes (건설현장 절취사면의 산성배수 발생특성과 잠재적 산발생능력 평가)

  • Lee, Gyoo-Ho;Kim, Jae-Gon;Lee, Jin-Soo;Chon, Chul-Min;Park, Sam-Gyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.491-498
    • /
    • 2005
  • Acid Rock Drainage(ARD) is the product formed by the atmospheric(i.e. by water, oxygen and carbon dioxide) oxidation of the relatively common iron-sulphur minerals pyrite($FeS_2$). ARD causes the acidification and heavy metal contamination of water and soil and the reduction of slope stability. In this study the generation characteristics and the prediction of ARD of various road cut slopes were studied. An attempt to classify the rocks into several groups according to their acid generation potentials was made. Acid Base Accounting(ABA) tests, commonly used as a screening tool in ARD predictions, were performed. Sixteen rock samples were classified into PAF(potentially acid forming) group and four rock samples into NAF(non-acid forming) group. The chemical analysis of water samples strongly suggested that ARD with high content of heavy metals and low pH could pollute the ground water and/or stream water.

  • PDF

The Comprehensive Proportional Hazards Model Incorporating Time-dependent Covariates for Water Pipes (상수관로에 대한 시간종속형 공변수를 포함한 포괄적 비례위험모형)

  • Park, Su-Wan
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.6
    • /
    • pp.445-455
    • /
    • 2009
  • In this paper proportional hazards models for the first through seventh break of 150 mm cast iron pipes in a case study area are established. During the modeling process the assumption of the proportional hazards for covariates on the hazards is examined to include the time-dependent covariate terms in the models. As a result, the pipe material/joint type and the number of customers are modeled as time-dependent for the first failure, and for the second failure only the number of customers is modeled as time-dependent. From the analysis on the baseline hazard functions the failure hazards are found to be generally increasing for the first and second failure, while the hazards of the third break and beyond showed a form of a bath-tub. Furthermore, the changes in the baseline hazard rates according to the time and number of break reflect that the general condition of the pipes is deteriorating. The factors causing pipe break and their effects are analyzed based on the estimated regression coefficients and their hazard ratios, and the constructed models are verified using the deviance residuals of the models.

Analysis of biological hazards and control points in layer houses (산란계 농장에서의 생물학적 위해요인과 관리점 분석)

  • Lee, Sung-Mo;Yoo, Han Sang;Honsg, Chong-Hae
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.4
    • /
    • pp.593-605
    • /
    • 2004
  • An egg has been considered as one of the most important food sources because of it's nutritional superiority and reasonable price. With the complexity of egg flow system from production to consumption in Korea, preventive measures for egg safety have been required. Therefore, our study was carried out to analyze hazards for the egg under farm level and develope preventive measures with a purpose of obtaining egg safety. To analyze biological hazards, microbial contamination of egg(normal, dirty and cracked), water, feed, manure and equipments associated with laying were investigated. One isolate of Salmonella enteritidis and S. bardo were detected from the manure and dirty egg shell respectively. The sanitary conditions in the farm were surveyed by questionaries. Confirmation of vaccination for purchasing chicks and establishment of sanitary guidances for water and type of water suppliers ought to be preceded. Feed supplier systems including feed tanks, feed pipes and hoppers were known that their contamination might give it a chance to infect individuals and egg content and shell. The safe and rapid disposal of dead chickens and rodent were reported as more crucial factors to prevent infectious disease and manage good sanitation. Egg selector and collecting belt should be kept properly not to be contaminated from egg fluids and feces. It should be also considered that regular gathering of eggs, removal of dirty or cracked ones, storage under refrigeration and the use of disposable egg tray were continuously fulfilled. Conclusively, Our results suggested that HACCP-based system for providing fresh and safe eggs to consumers should be applied to the farm.

Wet/dry Repetitions of Centennial Scale Reconstructed by Inorganic Chemistry of the Mid-Holocene Hwayang Wetland in the West Coast of Korea

  • Yang, Dong-Yoon;Kim, Ju-Yong;Nahm, Wook-Hyun;Yi, Sang-Heon;Kim, Jin-Kwan;Kim, Jeong-Chan;Lee, Jin-Young
    • The Korean Journal of Quaternary Research
    • /
    • v.21 no.2
    • /
    • pp.69-73
    • /
    • 2007
  • Inorganic geochemical and mineralogical analyses from the trench sediments of the Hwayang wetland were carried out to verify the wet/dry conditions during 6000 - 5000 yr BP and abnormal event of 6300 yr BP of Korean west coast. Lithostratigraphy, mineralogy and major element concentrations of the sediments of the trench indicate that during 6000 - 5000 yr BP, a wet/dry conditions might be repeated at an interval of 200 years. Carbonate minerals precipitated with the decrease of water depth in the lake or wetland after about 6000 yr BP. On the other hand, the sediments coarser in mean grain size and larger in standard deviation were corresponded with periods of 6300 yr BP and 6230 yr BP. Especially, such a feature of grain size distribution of 6300 yr BP appears in other wetlands situated in the west coast, e.g., Hwangsan wetland and Cheollipo coastal wetland. During the period, the coarse sediments seem to have been delivered by a high energy like storming.

  • PDF

The Proportional Hazards Modeling for Consecutive Pipe Failures Based on an Individual Pipe Identification Method using the Characteristics of Water Distribution Pipes (상수도 배수관로의 특성에 따른 개별관로 정의 방법을 이용한 파손사건 사이의 비례위험모델링)

  • Park, Suwan;Kim, Jung Wook;Jun, Hwan Don
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.87-96
    • /
    • 2007
  • In this paper a methodology of identifying individual pipes according to the internal and external characteristics of pipe is developed, and the methodology is applied to a case study water distribution pipe break database. Using the newly defined individual pipes the hazard rates of the cast iron 6 inch pipes are modeled by implementing the proportional hazards modeling approach for consecutive pipe failures. The covariates to be considered in the modeling procedures are selected by considering the general availability of the data and the practical applicability of the modeling results. The individual cast iron 6 inch pipes are categorized into seven ordered survival time groups according to the total number of breaks recorded in a pipe to construct distinct proportional hazard model (PHM) for each survival time group (STG). The modeling results show that all of the PHMs have the hazard rate forms of the Weibull distribution. In addition, the estimated baseline survivor functions show that the survival probabilities of the STGs generally decrease as the number of break increases. It is found that STG I has an increasing hazard rate whereas the other STGs have decreasing hazard rates. Regarding the first failure the hazard ratio of spun-rigid and spun-flex cast iron pipes to pit cast iron pipes is estimated as 1.8 and 6.3, respectively. For the second or more failures the relative effects of pipe material/joint type on failure were not conclusive. The degree of land development affected pipe failure for STGs I, II, and V, and the average hazard ratio was estimated as 1.8. The effects of length on failure decreased as more breaks occur and the population in a GRID affected the hazard rate of the first pipe failure.