• Title/Summary/Keyword: Water gauge

Search Result 346, Processing Time 0.025 seconds

Comparison of Topex/Poseidon sea levels data and Tide Gause sea levels data from the South Indian Ocean (남인도양에서의 해수면에 대한 위성자료(Topex/Poseidon 고도계)와 현장자료(Tide Gauge 해면계)간의 비교)

  • 윤홍주;김상우;이문옥;박일흠
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • According to standard procedures as defined in the users handbook for sea level data processes, I was compared to Topex/poseidon sea level data from the first 350days of mission and Tide Gauge sea level data from the Amsterdam- Crozet- Kerguelen region in the South Indian Ocean. The comparison improves significantly when many factors for the corrections were removed, then only the aliased oceanic tidal energy is removed by oceanic tide model in this period. Making the corrections and smoothing the sea level data over 60km along-track segments and the Tide Gauge sea level data for the time series results in the digital correlation and RMS difference between the two data of c=-0.12 and rms=11.4cm, c=0.55 and rms=5.38cm, and c=0.83 and rms=2.83cm for the Amsterdam, Crozet and Kerguelen plateau, respectively. It was also found that the Kerguelen plateau has a comparisons due to propagating signals(the baroclinic Rossby wave with velocity of -3.9~-4.2cm/sec, period of 167days and amplitude of 10cm) that introduce temporal lags($\tau$=10~30days) between the altimeter and tide gauge time series. The conclusion is that on timescales longer than about 10days the RMS sea level errors are less than or of the order of several centimeters and are mainly due to the effects of currents rather than the effects of sterics(water temperature, density) and winds.

  • PDF

On the determination of the maximum water requirement Stage and the net unit duty of water in the rice fields (논벼의 최대용수시기와 순단위용수량의 결정에 대하여)

  • 김철기;김재휘
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.4
    • /
    • pp.37-51
    • /
    • 1984
  • The purpose of this study is to find out the determination method of designed duty of water in the rice fields through the comparison of the net unit duty of water at the late reduction division to heading stage with that at the planting stage. The data used for analysing this problem are the data of precipitation and gauge evaporation observed by Cheong-ju Meterological Center, the coefficient of evapotranspiration by College of Agriculture, Chung Buk University and the data of transplanting progressing in Boun area. The results obtained from this analysis are summarized as follows. 1.The occurring year of 1/10 probability value for available precipitation, gauge evaporation and mean maximum daily evapotranspiration during growing season is the year of 1977. 2.The 1/10 probability values of mean maximum evapotranspiration per day under the production rate of 1, 400kg/l0a and 1, 500kg/10a based on the weight of dry matters are 9. 2mm/day and 9. 6mm/day, respectively. 3.The net unit duty of water required in the fields that the maximum planting rate exists is more than the one in the fields that the planting rate is uniform in the planting stage. 4.The determination of net unit duty of water in the late reduction division to heading stage or the planting stage depends upon the daily evapotranspiration and percolation rate in the late reduction division to heading stage or the water depth required for planting and daily consumptive use of water after planting at the planting stage. Therefore the use of figure 5-(1) to figure 5-(6) can easily make the determination of the designed net unit duty of water out of above two kinds of net unit duty of water.

  • PDF

Development of Wave Height Field Measurement System Using a Depth Camera (깊이카메라를 이용한 파고장 계측 시스템의 구축)

  • Kim, Hoyong;Jeon, Chanil;Seo, Jeonghwa
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.6
    • /
    • pp.382-390
    • /
    • 2021
  • The present study suggests the application of a depth camera for wave height field measurement, focusing on the calibration procedure and test setup. Azure Kinect system is used to measure the water surface elevation, with a field of view of 800 mm × 800 mm and repetition rate of 30 Hz. In the optimal optical setup, the spatial resolution of the field of view is 288 × 320 pixels. To detect the water surface by the depth camera, tracer particles that float on the water and reflects infrared is added. The calibration consists of wave height scaling and correction of the barrel distortion. A polynomial regression model of image correction is established using machine learning. The measurement results by the depth camera are compared with capacitance type wave height gauge measurement, to show good agreement.

Image-based rainfall prediction from a novel deep learning method

  • Byun, Jongyun;Kim, Jinwon;Jun, Changhyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.183-183
    • /
    • 2021
  • Deep learning methods and their application have become an essential part of prediction and modeling in water-related research areas, including hydrological processes, climate change, etc. It is known that application of deep learning leads to high availability of data sources in hydrology, which shows its usefulness in analysis of precipitation, runoff, groundwater level, evapotranspiration, and so on. However, there is still a limitation on microclimate analysis and prediction with deep learning methods because of deficiency of gauge-based data and shortcomings of existing technologies. In this study, a real-time rainfall prediction model was developed from a sky image data set with convolutional neural networks (CNNs). These daily image data were collected at Chung-Ang University and Korea University. For high accuracy of the proposed model, it considers data classification, image processing, ratio adjustment of no-rain data. Rainfall prediction data were compared with minutely rainfall data at rain gauge stations close to image sensors. It indicates that the proposed model could offer an interpolation of current rainfall observation system and have large potential to fill an observation gap. Information from small-scaled areas leads to advance in accurate weather forecasting and hydrological modeling at a micro scale.

  • PDF

Efficient Management of the pH of the Wet Scrubber Washing Water for Risk Mitigation (리스크 완화를 위한 Wet Scrubber 세정수 pH의 효율적 관리)

  • Joo, Dong-Yeon;Seoe, Jae Min;Kim, Myung-Chul;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.85-92
    • /
    • 2020
  • Wet Scrubber reacts the incoming pollutant gas with cleaning water (water + absorbent) to absorb pollutants and release the clean air to the atmosphere. Wet scrubbers and packed tower scrubbers using this principle are widely used in businesses that emit acid gases. In particular, in the etching process using hydrochloric acid (HCl), alkaline washing water (NaOH) having a pH of about 8 to 11 is used to absorb a large amount of acid gas. However, These salts are attached to the injection nozzle (nozzle), filling material (packing), and the demister (Demister), causing air pollution, human damage, and inoperability due to clogging and acid gas discharge. Therefore, In this study, an improvement plan was proposed to manage the washing water with pH 3~4 acidic washing water. The test method takes samples from the Wet Scrubber flue measurement laboratory twice a month for 1 year. Hydrogen chloride (HCl) concentration (ppm) was measured, and nozzle clogging and scale conditions were measured, compared, and analyzed through a differential pressure gauge and a pressure gauge. As a result of the check, it was visually confirmed that the scale was reduced to 50% or less in the spray nozzle, filler, and demister. In addition, the emission limit of hydrogen chloride in accordance with the Enforcement Regulation of the Air Quality Conservation Act [Annex 8] met 3 ppm or less. Therefore, even if the washing water is operated in an acidic pH range of 3 to 4, it is expected to reduce air pollution and human damage due to clogging of internal parts, and it is expected to reduce maintenance costs such as regular cleaning or replacement of parts.

Runoff Simulation of An Urban Drainage System Using Radar Rainfall Data (레이더 강우 자료를 이용한 도시유역의 유출 모의)

  • Kang, Na Rae;Noh, Hui Seung;Lee, Jong So;Lim, Sang Hun;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.15 no.3
    • /
    • pp.413-422
    • /
    • 2013
  • In recent, the rainfall is showing different properties in space and time but the ground rain gauge only can observe rainfall at a point. This means the ground rain gauge has the limitations in spatial and temporal resolutions to measure rainfall and so there is a need to utilize radar rainfall which can consider spatial distribution of rainfall This study tried to apply radar rainfall for runoff simulation on an urban drainage system. The study area is Guro-gu, Seoul and we divided study area into subbasins based on rain gauge network of AWS(Automatic Weather station). Then the radar rainfalls were adjusted using rainfall data of rain gauge stations the areal rainfalls were obtained. The runoffs were simulated by using XP-SWMM model in subbasins of an urban drainage system. As the results, the adjusted radar rainfalls were underestimated in the range of 60 to 95% of rain gauge rainfalls and so the simulated runoffs from the adjusted radar and gauge rainfalls also showed the differences. The runoff peak time from radar rainfall was occurred more fast than that from gauge rainfall.

Evaluation of Spatially Disproportionate Rain Gauge Network for the Correction of Mean-Field Bias of Radar Rainfall: A Case Study of Ganghwa Rain Radar (레이더 강우의 편의 보정을 위한 지역적으로 편중된 우량계망의 평가: 강화 강우레이더의 사례 연구)

  • Yoo, Chul-Sang;Yoon, Jung-Soo;Kim, Byoung-Soo;Ha, Eun-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.6
    • /
    • pp.493-503
    • /
    • 2009
  • Estimation of the mean-field bias of radar rainfall is to determine the difference between the areal means of radar and rain gauge rainfall, where the rain gauge rainfall is assumed to be the truth. To exactly determine this bias, the variance of the difference between two observations must be small enough, thus, enough number of observations is indispensible. So, the problem becomes to determine the number of rain gauges to satisfy the level of variance of the difference between two observations. Especially, this study focuses on the case when the rain gauges are disproportionate spatially. This is the problem for the Ganghwa rain radar for the observation of rainfall within the Imjin river basin and the same problem also occurs when a radar is located in between land and ocean. This study considered the Imjin river basin, and compared two cases when rain gauges are available only within the downstream part, about one third of the whole basin, and over the whole basin. Based on the results derived, the rain gauge density within the downstream part of the Imjin river basin was proposed to secure the same accuracy obtained when the rain gauges are available over the whole Imjin river basin.

Calibration of Health Monitoring System installed in the Railway Bridges (철도교 상시계측시스템의 교정 및 교정상수 설정에 관한 연구)

  • 박준오;이준석;최일윤;민경주
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.148-157
    • /
    • 2002
  • A health monitoring system becomes a useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. The health monitoring system not only gives the direct measurement data of the railway bridges but also provides the basic data on the maintenance of the structures. Therefore, periodic calibrations of the health monitoring system will be a necessary step toward precise and accurate assessment of the railway bridges. In this study, the calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges is reviewed and some findings are explained in detail: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in full length. Based on the regression results, it was found that the gauge factors need to be readjusted according to the regression equation but, since the deviation or shift is not serious so far, long-term observation on each sensor is also recommended. Future work will be concentrated on the long-term analysis of each sensor and on the database creation so that the assessment of the structures is possible.

Development of a Digital Soil Tensiometer using Porous Ceramic Cups (다공 세라믹 컵을 이용한 디지털 토양수분 장력계 개발)

  • Jung, In-Kyu;Chang, Young-Chang;Kim, Ki-Bok;Kim, Yong-Il;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.448-454
    • /
    • 2007
  • This study was conducted to develop a 100 kPa soil tensiometer mainly consisted of a porous ceramic cup, water-holding tube, and a digital vacuum gauge, through theoretical design analysis and experimental performance evaluation. Major findings were as follows. 1. Theoretical analysis showed that air entry value of a porous media decreased as the maximum effective size of the pore increased, and the maximum diameter of the pores was $2.9\;{\mu}m$ for measuring up a 100 kPa of soil-water tension. 2. Property analysis of tensiometer porous cups supplied in Korean domestic market indicated that main components were $SiO_2$ and $Al_2O_3$ with a porosity range of $33.8{\sim}49.3%$. 3. The porous cup selected through sample fabrication and air-permeability tests showed weight ratios of 87% and 11% for $Al_2O_3$ and $SiO_2$. The analysis of SEM (scanning electron microscope) images showed that the sample was sintered at temperatures of about $1150^{\circ}C$, which consisted of pores with sizes of up to 25% of those for commercial porous cups. 4. The prototype soil tensiometer was fabricated using the developed porous cup and a digital vacuum gauge that could measure water tension with a pressure of 85 kPa in air tests. 5. In-soil tests of the prototype conducted during a period of 25-day drying showed that soil-water tension values measured with the prototype and commercial units were not significantly different, and soil-water characteristic curves could be established for different soils, confirming accuracy and stability of the prototype.

Synthesis of Radar Measurements and Ground Measurements using the Successive Correction Method(SCM) (연속수정법을 이용한 레이더 자료와 지상 강우자료의 합성)

  • Kim, Kyoung-Jun;Choi, Jeong-Ho;Yoo, Chul-Sang
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.7
    • /
    • pp.681-692
    • /
    • 2008
  • This study investigated the application of the successive correction method(SCM), a simple data assimilation method, for synthesizing the radar and rain gauge data. First, the number of iteration and influence radius for the SCM application were decided based on their sensitivity analysis. Also, for the evaluation of synthetic rainfall, the distributed rainfall field using the dense rainfall gauge network was assumed to be the true one. The synthetic rainfall field based on the SCM was also compared quantitatively with the one based on the co-Kriging frequently used nowadays. As the results, the SCM, a simple and economical data assimilation method, was found to secure the accuracy and statistical characteristics of the co-Kriging application.