• Title/Summary/Keyword: Water flow rate

Search Result 3,036, Processing Time 0.037 seconds

Correlation between Xerostomia, Stress, and Qi Movement Stagnation in Halitosis Patients (구취환자의 구강건조감과 스트레스, 기울의 상관성 분석)

  • Han, Ga-Jin;Kim, Jin-Sung;Seon, Jong-Ki;Son, Ji-Hee;Oh, Seung-Wha;Park, Young-Sun;Jung, Yong-Jae;Jerng, Ui-Min;Park, Jae-Woo;Ryu, Bong-Ha
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.3
    • /
    • pp.488-499
    • /
    • 2010
  • Objective : This study was designed to investigate the correlation between Qi movement stagnation condition, stress level and xerostomia in halitosis patients. Methods : Ninety-nine halitosis patients visiting the Halitosis Clinic in the hospital of Oriental medicine, Kyung Hee University from January, 2010 to May, 2010 were recruited. The subjects were assessed on their stress levels(based on the Stress Response Inventory), xerostomia symptoms(based on the 8-item Visual Analogue Scale xerostomia questionnaire), and Qi movement stagnation(氣鬱) condition(one of the subcategories in the Qi, blood and water pattern identification(氣血水辨證)). Salivary functions were evaluated using the unstimulated whole salivary flow rate measurements. Results : Compared to the non-Qi movement stagnation group(Qi movement stagnation pattern identification score < 30), the confirmed Qi movement stagnation group(Qi movement stagnation pattern identification score $\geqq$ 30) showed higher levels of xerostomia and stress. In the regression analysis, the Qi movement stagnation condition and stress levels showed a significant correlation. Furthermore, the Qi movement stagnation condition and stress levels each displayed significant correlations with xerostomia. Conclusions : The results of this study suggest that stress and Qi movement stagnation condition contribute to xerostomia symptoms in halitosis patients. Considering the correlation found between the Qi movement stagnation and stress, this study suggests a novel methodology in treating xerostomia, halitosis, and other stress-related disorders through the Qi movement stagnation-related approach.

Quantitative Analysis of Antioxidants in Korean Pomegranate Husk (Granati pericarpium) Cultivated in Different Site (HPLC에 의한 산지별 한국산 석류과피 중 항산화화합물의 함량분석)

  • Kwak, Hye-Min;Jeong, Hyun-Hee;Song, Bang-Ho;Kim, Jong-Guk;Lee, Jin-Man;Hur, Jong-Moon;Song, Kyung-Sik
    • Applied Biological Chemistry
    • /
    • v.48 no.4
    • /
    • pp.431-434
    • /
    • 2005
  • The quantitative analytical method for major antioxidants, ellagic acid and punicalagin, in pomegranate husk (Granati pericarpium) were established by HPLC. The optimal HPLC conditions were as follows: Column; Agilent Zorbax Eclipse XDB-C18 ($4.6{\times}150mm,\;5{\mu}m$), mobile phase; 1% formic acid in water (A) and 1% formic acid in MeCN (B) (gradient elution of 5% to 100% B for 50 min), flow rate; 0.8 ml/min., detection; UV 254 nm. The optimal pre-treatment conditions for HPLC analysis were as follows: 5 g of pomegranate husk in 100 ml of 95% EtOH, refluxed for 3 h. Under these analytical conditions, punicalagin and ellagic acid contents in Korean pomegranates husks which were cultivated in five different sites were determined. As results, the ellagic acid and punicalagin (as a mixture of ${\alpha-\;and\;{\beta}-anomer$) contents were the highest in Haepyung pomegranate husk $(15.27{\mu}g/mg)$ and Jangsung pomegranate husk $(16.21{\mu}g/mg)$, respectively.

A Study of Nonpoint Source Pollutants Loads in Each Watershed of Nakdong River Basin with HSPF (HSPF 모델을 이용한 낙동강유역의 유역단위별 비점오염부하량 산정)

  • Kwon, Kwangwoo;Choi, Kyoung-sik
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.1
    • /
    • pp.68-77
    • /
    • 2017
  • In order to estimate the non-point pollution loads from each watersheds among 209 watersheds, the calibration and validation of HSPF model were carried out based on 2012 in 2013 years. In the case of flow rate, R2 of calibration and validation were 0.71~0.93 and 0.71~0.79, which were relatively good values. With the respect to calibration of water quality, % differences between measured and simulated values were 0.4 ~ 9.7 of DO, BOD 0.5 ~ 30.2% and TN 1.9~28.6% except for Hwhangkang B site. In case of validation, DO was 0.2 ~ 13.7%, BOD 1.3~23% and TN 0.5~24.3% excluding Hwhangkang B. However, since the concentration of TP was very small compared with other items, the range of difference was large as 0.8~55.3%. level. As the result of calculating annual accumulative BOD loads for each watershed, it was found that RCH 123 (Uryeong, Gyeongsangnamdo), RCH 121 (Jinju, Gyeongsangnamdo) and RCH 92 (Daegu) were the high ranked. The unit watersheds including various landuse type susch as forest and agricultural sites in mainstream areas have a higher BOD nonpoint pollution load than those in dam regions. However, the results of the annual cumulative loading of the basins for nutrients did not appear to be consistent with the BOD annual cumulative loading ranks. Other factors that represent watershed characteristics such as landslope and soiltypes, including landuse pattern, have been found to be closely related to nonpoint pollutant loads.

Adsorption Characteristics of CO2 on Activated Carbons Treated with Alkali-metal Salts (알칼리금속염으로 처리된 활성탄에 대한 CO2의 흡착특성)

  • Ryu, Dong Kwan;Kim, Sung Hyun
    • Applied Chemistry for Engineering
    • /
    • v.9 no.2
    • /
    • pp.286-293
    • /
    • 1998
  • Two methods were used to enhance the adsorption capacity of activated carbons. One is to impregnate activated carbons with chemical compounds which have a good affinity for $CO_2$. The other is to activate by heat-treating after impregnation with KOH on activated carbons(AC). The chemical compounds impregnated on AC were alkali metal, alkaline earth metal, and transition metal chlorides. The adsorption capacity of $CO_2$ on AC impregnated with these metals was less than that of pure AC. These compounds have not the chemical affinity for $CO_2$ and obstruct the micropore of AC. The experiment of breakthrough for $CO_2$ on AC impregnated with KOH showed the increase of the adsorbed amount of $CO_2$ in influent gases containing water vapor. This means that KOH adsorbes $CO_2$ gas. However, the adsorbents impregnated with KOH had not the reproducibility because of the production of $K_2CO_3$ by the reaction of KOH with $CO_2$. The amount of $CO_2$ adsorbed on the heat-treated AC at $800^{\circ}C$ increased with the amount of impregnation. The adsorption capacity of $CO_2$ was the largest when the ratio of weight of KOH to AC equal to 4. The isosteric heat of adsorption was calculated by the equation of Clausius-Clapeyron form adsorption capacity data of $CO_2$ for the temperature change. In addition, the characteristics of $CO_2$ breakthrough curve were surveyed for the change of flow rate and concentration.

  • PDF

Process gas purification using cyclone recirculation and cooling process (싸이클론 재순환, 냉각공정을 이용한 공정가스 정제 연구)

  • Kim, Ju-Hoe;Jo, Woo-Jin;Choi, Young-Tae;Jo, Young-Min;Kim, Sang-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 2018
  • Renewable energy has been of interests in the area of modern alternative fuels. Biogas is produced in waste landfill sites through anaerobic digestion processes, including hydrolysis, acidogenesis, organic acid fermentation (acetogenesis), and methane fermentation (methanogenesis). High contents of fine dust and moisture limited its utilization for direct combustion, town gas and vehicle fuel. Thus, this study proposed a new design for a cooling device using a centrifugal cyclone for simultaneous removal of fine dust and moisture as a pretreatment in the purification processes. A heat exchanger and an ID fan, which are installed inside and outside of the cyclone, in order to cool the humid gas below the freezing point and form a foggy mist. Such an atmosphere enhanced to capture fine dust as recirculating the cold mist flow. The water removal rate was 80.8% at a relative humidity of 95%, and the particle removal efficiency was 98.3% for $2.5{\mu}m$. Simultaneous removal efficiency was 70.8% and 99.6% for particle and moisture respectively.

Determination of Terazocin in Human Plasma by Liquid Chromatography and Bioequivalence Study of Teratonin® Tablets (액체크로마토그래프법에 의한 사람 혈장 중 테라조신의 정량 및 테라토닌® 정의 생물학적 동등성)

  • Cho, Eun-Sook;Kang, Sung-Ha;Chun, In-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.2
    • /
    • pp.119-125
    • /
    • 2002
  • A rapid, selective and reproducible high-performance liquid chromatographic method has been developed for the determination of terazocin in human plasma. Terazocin plus the internal standard, prazocin hydrochloride, were extracted from alkalified plasma with tert-butylmethyl ether, back-extracted into 0.05% phosphoric acid. Fifty ${\mu}l-portions$ of extract were injected onto a octadecylsilane column and eluted with a mixture of acetonitrile, water and triethylamine (30 : 70 : 0.1 v/v, adjusted to pH 5.0 with dilute phosphoric acid) at a flow rate of 1.0 ml/min. The fluorescence intensity of column eluents was monitored at excitation wavelength of 250 nm and emission wavelength of 370 nm. No interference peaks were observed. The practical limit of quantitation was 5 ng/ml for terazocin. The average intraday and interday coefficients of variation were 4.15 and 3.54%, respectively. Also intraday and interday precisions over the range $5{\sim}60\;ng/ml$ were $0.49{\sim}2.92\;and\;0.38{\sim}5.12%$, respectively. The bioequivalence of two terazosin tablets, the $Hytrine^{\circledR}$ (Il Yang Pharmaceutical Co., Ltd.) and the $Teratonin^{\circledR}$ (Sam-A Pharmaceutical Co., Ltd.), was evaluated according to the guideline of Korea Food and Drug Administration (KFDA). Sixteen healthy male volunteers $(24.6{\pm}2.0\;years\;old)$ were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 2 mg of terazosin was orally administered, blood was taken at predetermined time intervals and the concentration of terazosin in plasma was determined with a HPLC method using spectrofluorometric detector. AUC was calculated by the linear trapezoidal method. $C_{max}\;and\;T_{max}$ were compiled from the plasma drug concentration-time data. Analysis of variance (ANOVA) was utilized for the statistical analysis of the parameters. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between the two preparations were 0.21 %, 5.53% and 8.82%, respectively. The powers $(1-{\beta})\;for\;AUC_t,\;C_{max}\;and\;T_{max}$ were >99%, 97.49%, and 33.26%, respectively. Minimum detectable differences $({\Delta},\;%)\;at\;{\alpha}=0.1\;and\;1-{\beta}=0.8$ and the 90% confidence intervals were all less than ${\pm}20%$ except for $T_{max}.\;AUC_t\;and\;C_{max}$ met the criteria of KDFA for bioequivalence, indicating that $Teratonin^{circledR}$ tablets are bioequivalent to $Hytrine^{circledR}$ tablets.

DEVELOPMENT OF NANO-FLUID MOVEMENT MEASURING DEVICE AND ITS APPLICATION TO HYDRODYNAMIC ANALYSIS OF DENTINAL FLUID (미세 물 흐름 측정장치의 개발과 상아세관액의 수력학에의 응용)

  • Lee, In-Bog;Kim, Min-Ho;Kim, Sun-Young;Chang, Ju-Hea;Cho, Byung-Hoon;Son, Ho-Hyun;Back, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • This study was aimed to develop an instrument for real-time measurement of fluid conductance and to investigate the hydrodynamics of dentinal fluid. The instrument consisted of three parts; (1) a glass capillary and a photo sensor for detection of fluid movement, (2) a servo-motor, a lead screw and a ball nut for tracking of fluid movement, (3) a rotary encoder and software for data processing. To observe the blocking effect of dentinal fluid movement, oxalate gel and self-etch adhesive agent were used. BisBlock (Bisco) and Clearfil SE Bond (Kuraray) were applied to the occlusal dentin surface of extracted human teeth. Using this new device, the fluid movement was measured and compared between before and after each agent was applied. The instrument was able to measure dentinal fluid movement with a high resolution (0.196 nL) and the flow occurred with a rate of 0.84 to 15.2 nL/s before treatment. After BisBlock or Clearfil SE Bond was used, the fluid movement was decreased by 39.8 to 89.6%.

Study on the Combustion Characteristics of a Small-Scale Orimulsion Boiler (소형 오리멀젼 보일러의 연소특성 연구)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Choi, Young-Chan;Lee, Jae-Gu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1081-1089
    • /
    • 2005
  • In order to examine the application feasibility of Orimulsion fuel in a commercial boiler using heavy fuel oil, a numerical and experimental research efforts have been made especially to figure out the fundamental combustion characteristics of this fuel in a small-scale boiler. One of the notable combustion features of Orimulsion fuel is the delayed appearance of flame location with the flame shape of rather broad distribution, which is found experimentally and confirmed by numerical calculation. This kind of flame characteristics is considered due to the high moisture content included inherently in the process of Orimulsion manufacture together with micro-explosion by the existence of fine water droplets. In order to investigate the effect on the combustion characteristics of Orimulsion, a series of parametric investigation have been made in terms of important design and operational variables such as injected amount of fuel, types of atomization fluid, and phonemenological radiation model employed in the calculation, etc. The delayed feature of peak flame can be alleviated by the adjustment of the flow rate of injected fuel and the generating features of CO, $SO_2$ and NO gases are also evaluated in the boiler. When the steam injection as atomizing fluid is used, the combustion process is stabilized with the reduced region of high flame temperature. In general, the calculation results are physically acceptable and consistent but some refinements of phenomenological models are necessary for the better resolution of pollutant formation. From the results of this small-scale Orimulsion boiler, it is believed that a number of useful information are obtained with the working computer program for the near future application of Orimulsion fuel to a conventional boiler.

Numerical Comparisons of Flow Properties Between Indivisual and Comprehensive Consideration of River Inundation and Inland Flooding (하천범람과 내수침수의 개별적·복합적 고려에 따른 흐름 특성의 수치적 비교)

  • Choi, Sang Do;Eum, Tae Soo;Shin, Eun Taek;Song, Chang Geun
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.10
    • /
    • pp.115-122
    • /
    • 2020
  • Due to the climate change, torrential rain downpours unprecedentedly, and urban areas repeatedly suffer from the inundation damages, which cause miserable loss of property and life by flooding. Two major reasons of urban flooding are river inundation and inland submergence. However, most of previous studies ignored the comprehensive mechanism of those two factors, and showed discrepancy and inadequacy due to the linear summation of each analysis result. In this study, river inundation and inland flooding were analyzed at the same time. Petrov-stabilizing scheme was adopted to capture the shock wave accurately by which river inundation can be modularized. In addition, flux-blocking alrotithm was introduced to handle the wet and dry phenomena. Sink/source terms with EGR (Exponentially Growth Rate) concept were incorporated to the shallow water equations to consider inland flooding. Comprehensive simulation implementing inland flooding and river inundation at the same time produced satisfactory results because it can reflect the counterbalancing and superposition effects, which provided accurate prediction in flooding analysis.

A study on the residues of fluoroquinolones in hen's eggs consumed in Incheon Metropolitan city (인천광역시에서 유통되는 계란의 플루오로퀴놀론계 항균물질 잔류 실태 조사)

  • Park, Eun-Jeong;Lim, Ji-Huen;Lee, Sung-Mo;Im, Jeong-Soo;Oh, Dae-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.3
    • /
    • pp.385-395
    • /
    • 2008
  • This study was carried out to investigate the residue level of fluoroquinolones in hen's general eggs and specific eggs by microbiological assay method and high performance liquid chromatography (HPLC) method. HPLC separation was carried out by reversed phase chromatography on a Symmetry $C_{18}$ (250${\times}$4.6 mm, $5{\mu}m$ particle size) with a phase composed of distilled water (containing 0.4% triethylamine and phosphoric acid) : Methanol (780 : 220, v/v), pumped isocratically at a flow rate of 1.0ml/min. A fluorescence detector was utilized with an excitation wavelength of 278nm and an emission wavelength of 456nm. The calibration curves were linear $({\gamma}^2{\geq}0.999)$ over a concentration range of $0.025{\sim}0.4{\mu}g/ml$. Average recoveries of the five fluoroquinolones in whole eggs at fortified levels of $0.05{\sim}0.2{\mu}g/g$ were ranged mean $78.1{\sim}91.7%$ and low coefficient of variation was less than 10% for all analysed samples. The limits of detection and limits of quantification for whole eggs were $1.2{\sim}6.0ng/g$ and $2.3{\sim}9.1ng/g$, respectively. Only one hen's general eggfrom chicken farm in Incheon was detected with the residual fluoroquinolones (Microbiological assay method; 1 of 47 general eggs) ; the range of residual concentration enrofloxacin was 0.12ppm. Those in food stores were detected with the residual fluoroquinolones (Microbiological assay method; 4 of 88 general eggs) ; the ranges of residual concentration enrofloxacin were $0.15{\sim}2.2 ppm$, ciprofloxacin $0.01{\sim}0.06ppm$, and hen's specific eggs (40) in food stores were not detected. For the microbiological assay method of fluoroquinolones in hen's eggs, as the results of comparative analysis, the disc diffusion method with E coli may be a little highly detected for the residual fluoroquinolones.