• Title/Summary/Keyword: Water exchange ratio

Search Result 187, Processing Time 0.036 seconds

Transport of Organic Acids through Porous Sulfonated Polystyrene Divinylbenzene Copolymer Membranes (다공성 술폰화 폴리스티렌-디비닐벤젠 공중합체 분리막을 통한 유기산의 이동)

  • 이광재;한정우;조영일
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1991
  • Sulfonated polystyrene-divinylbenzene(PS-DVB) copolymer membranes were prepared using different diluents (toluene, cyclohexane, cyclohexanol), various diluent ratio and DVB contents. And initial fluxes of organic acids were investigated by varying pH and initial concentration. As a results, water content and ion-exchange capacity decreased with increasing DVB concetration. Among used diluents, cyclohexanol was the most efficient for building up the highest water content and ion-exchange capacity. In the experiment of permeation, carboxylic acid such as formic acid and acetic acid showed higher fluxes when pH was lower than pKa and amino add such as L-alanine showed minimum flux when pH was isoelectric value. The relationaship between initial fluxes and initial concentrations has been expressed by saturation kinetics.

  • PDF

Adsorption Characterization of Cd by Activated Carbon containing Hydroxyapatite using Response Surface Methodology (RSM) (반응표면분석법을 이용한 Hydroxyapatite 첨가 활성탄에서의 Cd 흡착특성에 관한 연구)

  • An, Sang-Woo;Yoo, Ji-Young;Choi, Jae-Young;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.943-950
    • /
    • 2009
  • Cadmium (Cd) adsorption onto the activated carbon containing hydroxyapatite (HAP) was investigated in batch experiments and response surface methodology (RSM) using the Box-Behnken methods were applied to the experimental results. Cd adsorption with different HAP mass ratio of from 10% to 30%. With more HAP, Cd was more adsorbed. These results suggest that the higher HAP mass causes an increase of the ion exchange potential of the HAP sorbent. Equilibrium experimental results from Cd adsorption was fitted to Langmuir and Freundlich isotherm models. Cd adsorption on HAP sorbent were found to follow the Freundlich isotherm model well in the initial adsorbate concentration range. Also, Cd adsorption was a function of the HAP mass ratio ($x_1$), initial Cd concentration ($x_2$), and initial pH ($x_3$) from the application of the RSM. Statistical results showed the order of significance of the independent variables to be initial Cd concentration > HAP mass ratio > initial pH.

A computer simulation of ion exchange membrane electrodialysis for concentration of seawater

  • Tanaka, Yoshinobu
    • Membrane and Water Treatment
    • /
    • v.1 no.1
    • /
    • pp.13-37
    • /
    • 2010
  • The performance of an electrodialyzer for concentrating seawater is predicted by means of a computer simulation, which includes the following five steps; Step 1 mass transport; Step 2 current density distribution; Step 3 cell voltage; Step 4 NaCl concentration in a concentrated solution and energy consumption; Step 5 limiting current density. The program is developed on the basis of the following assumption; (1) Solution leakage and electric current leakage in an electrodialyzer are negligible. (2) Direct current electric resistance of a membrane includes the electric resistance of a boundary layer formed on the desalting surface of the membrane due to concentration polarization. (3) Frequency distribution of solution velocity ratio in desalting cells is equated by the normal distribution. (4) Current density i at x distant from the inlets of desalting cells is approximated by the quadratic equation. (5) Voltage difference between the electrodes at the entrance of desalting cells is equal to the value at the exits. (6) Limiting current density of an electrodialyzer is defined as average current density applied to an electrodialyzer when current density reaches the limit of an ion exchange membrane at the outlet of a desalting cell in which linear velocity and electrolyte concentration are the least. (7) Concentrated solutions are extracted from concentrating cells to the outside of the process. The validity of the computer simulation model is demonstrated by comparing the computed results with the performance of electrodialyzers operating in salt-manufacturing plants. The model makes it possible to discuss optimum specifications and operating conditions of a practical-scale electrodialyzer.

Electrochemical nitrate reduction using a cell divided by ion-exchange membrane

  • Lee, Jongkeun;Cha, Ho Young;Min, Kyung Jin;Cho, Jinwoo;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • v.9 no.3
    • /
    • pp.189-194
    • /
    • 2018
  • Electrochemical reduction of nitrate was studied using Zn, Cu and (Ir+Ru)-Ti cathodes and Pt/Ti anode in a cell divided by an ion exchange membrane. During electrolysis, effects of the different cathode types on operating parameters (i.e., voltage, temperature and pH), nitrate removal efficiency and by-products (i.e., nitrite and ammonia) formation were investigated. Ammonia oxidation rate in the presence of NaCl was also determined using the different ratios of hypochlorous acid to ammonia. The operating parameter values were similar for all types of cathode materials and were maintained relatively constant. Nitrate was well reduced and converted mostly to ammonia using Zn and Cu cathodes. Ammonia, produced as a by-product of nitrate reduction, was oxidized in the presence of NaCl in the electrochemical process and the oxidation performance was enhanced upon increasing the hypochlorous acid-to-ammonia ratio to 1.09:1. Zn and Cu cathodes promoted the nitrate reduction to ammonia and the produced ammonia was finally removed from solution by reacting with hypochlorite ions. Using Zn or Cu cathodes, instead of noble metal cathodes, in the electrochemical process can be an alternative technology for nitrate-containing wastewater treatment.

Evaluation on the Electro-electrodialysis for hydrogen production by thermochemical water-splitting IS process (열화학적 수소제조 IS 프로세스의 효율향상을 위한 전해-전기투석의 실험적 평가)

  • Hong, Seong-Dae;Kim, Jeong-Geun;Lee, Sang-Ho;Choi, Sang-Il;Bae, Ki-Kwang;Hwang, Gab-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.13-16
    • /
    • 2006
  • Electro-electrodialysis (EED) experiments were carried out for the HI concentration from HIx $(HI-H_2O-I_2)$ solution to improve the Hl decomposition reaction in the thermochemical water-splitting is (iodine-Sulfur) process. EED cell is composed of the collector electrode and electrolyte. Nafion 117 which was cation exchange membrane used as an electrolyte, and the activated carbon cloth used as an electrode. The HI concentration experiment was carried out using the HIx solution and molar ratio of the $I_2$ were varied from 1 to 3 mole. The cell voltages were decreased as temperature increase. And, membrane properties such as transport number of proton and electro-osmosis coefficient were decreased as temperature increase

  • PDF

Preparation of Anion Exchange Membranes for Electrodialysis by Impregnating Porous Polyethylene Films with Crosslinked Poly(vinylbenzyl ammonium chloride)s (다공성 폴리에틸렌 필름에 가교된 poly(vinylbenzyl ammonium chloride)를 충진한 전기투석용 음이온 교환 복합막의 제조)

  • Kim, Jeong-Hoon;Lee, Jung-Soo;Yoo, Min-Chul;Chang, Bong-Jun;Kang, Ho;Lee, Soo-Bok
    • Membrane Journal
    • /
    • v.18 no.2
    • /
    • pp.138-145
    • /
    • 2008
  • A series of anion exchange composite membranes were prepared and characterized for electro-dialysis process used in the removal of toxic anion and cation polutants in groundwater or wastewater. The membranes were prepared as follows; first, porous poly(ethylene) (PE) substrates were fully impregnated with monomer mixtures with various ratio of vinylbenzylchloride (VBC), divinylbenzene (DVB) and ${\alpha},\;{\alpha}$-azobis(isobutyronitrile) (AIBN). Second, they were thermally polymerized to yield crosslinked poly(VBC-DVB)/PE composite membranes. Finally, the membranes were treated in trimethylamine (TMA)/acetone to give $-N^+(CH_3)_3$-containing poly(VBC-DVB)/PE membranes. The basic membrane properties such as ion exchange capacity (IEC), electric resistance and water content of the resulting membranes were measured as a function of VBC/DVB and TMA/Acetone content. As a result, the composite membranes showed lower electric resistance, lower water content and higher IEC than commercial anion exchange membranes (AMX, Astom) due to thin PE substrates, indicating that the composite membranes could be successfully applied to the electrodialysis for water treatment.

Influence of Ion Exchange Capacity on the Performance of Ultrafiltration Membrane Prepared from Anion Charged Poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite)imide Derivatives (음이온성 Poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite)Imide Derivatives 한외여과막의 투과특성)

  • Jong-Young Jeon
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.26-36
    • /
    • 2004
  • Ultrafiltration membranes based on anion charged poly(bis[4-(3-aminophenoxy)phenyl]sulfone pyromellite) imide derivatives (ACPI) were prepared by the phase inversion method. The polymers have good solubility in aprotic polar solvents. The composition of casting solution and the casting conditions played an important role in determining the permeation characteristics of membrane because the membrane structure could be controlled by the preparation conditions. The extent of fouling-repression was observed by the relative ratio of permeate flux ($J_t$)/pure water flux ($J_0$) and the membrane filtration index (MFI). The characteristics were measured by aqueous solution of bovine serum albumin (BSA) over a pH range of 2.5-9.0. The ACPI membrane having a hydrophilic property was less fouled than the membrane prepared from the original polyimide. With increasing the ion exchange capacity of ACPI membrane, th $\varepsilon$ relative ratio of flux was higher while the membrane filtration index was lower as compared with the original polyimide membrane. From the further away from isoelectric point of bovin serum albumin, the permeation was higher as well as the formation of fouling was more diminish. ACPI membranes having various their properties could be obtained. Further, it was proved that their permeation properties could be determined from the preparation conditions, various operating conditions, and dim $\varepsilon$ rent ion exchange capacity of anion charged polyimide derivatives.

Identification of Proteins in Egg White Using Ion Exchange Cartridge and RP-HPLC (이온교환 카트리지와 RP-HPLC를 이용한 난백 단백질의 확인)

  • Kim, Hyun Moon;Kim, Ah Reum;Lee, Chang Soo;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.713-717
    • /
    • 2012
  • Approximately forty proteins in egg white have been widely studied for their functional properties. To develop a procedure of separation for pure and non-altered proteins from egg white, purification study was conducted to isolate lysozyme, ovotransferrin, and ovalbumin. Ion exchange cartridge can selectively separate proteins from egg white, and reversed-phase HPLC (RP-HPLC) could identify separated proteins. Proteins in egg white were purified by HI trap ion exchange cartridge SP and Q with buffers pH 8.0 and 5.2. C18 column (Phenomenex, USA) was used for RP-HPLC analysis and isocratic mobile phase was used with acetonitrile (ACN)/distilled water (DW)/trifluoroacetic acid (TFA) in the ratio of 50/50/0.1. Comparing the retention times of standards in RP-HPLC experiments showed that ovotransferrin, ovalbumin, and lysozyme in egg white were eluted successively in the RP-HPLC column after the pretreatment in SP and Q ion exchange cartridges.

Studies on Constitutents of the Higher Fungi of Korea : Antitumor Components of the Basidiocarps of Hypsizigus mamoreus (한국산 고등균류 만가닥버섯의 항암성분)

  • 박성미;진미림;김진숙;최응칠;김병각
    • YAKHAK HOEJI
    • /
    • v.37 no.5
    • /
    • pp.490-498
    • /
    • 1993
  • To find antitumor components in the hot water extract from the basidiocarps of Hypsizigus mamomus. protein-bound polysaccharides were purified and fractionated by DEAE-cellulose ion exchange column chromatography and Sepharose CL-4B gel filtration chromatography. When a dose of 20 mg/kg/day was injected intraperitoneally into ICR mice. fraction IV of the component showed the highest inhibition ratio of 73.8% against the count of hemolytic plaque forming cells in mice to 3.2 times. when IV was about 30 KD and the fraction was composed of 76.1% polysaccharide and 4.9% protein. The hexosamine was detected in all the fractions, showing that the polysaccharide and protein moieties were bound each other.

  • PDF

Field Application of the Slit Type Coastal Structures under Waves and Currents

  • Park, Sang-Gil;Kang, Sug-Jin;Kim, Kang-Min;Kim, Suk-Mun;Lee, Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.34 no.9
    • /
    • pp.711-718
    • /
    • 2010
  • Redevelopment of the domestic small fishing ports is being started in earnest by applying the environmentally friendly technology in order to attract tourists. For the purpose of improving water quality in the harbor, selection of breakwater type might have the priority to secure calmness and stability. Therefore, this study is to determine the hydraulic characteristics of reflective ratio, installation efficiency and stability of the special type of blocks through the hydraulic model experiment. The results were introduced to analyze for the effect of infield construction work through numerical analysis. Gujora, a small fishing port in southern Korea, is affected by the waves of SSE, S, SSW direction and strong tidal currents. The results of applying cylindrical slit block show that stability of the blocks and harbor calmness were secured. Considering that the pass rate of a long period wave is still excellent, the primary objective of wave control and the secondary objective of improving water exchange are satisfied simultaneously.