• Title/Summary/Keyword: Water exchange rate

Search Result 285, Processing Time 0.023 seconds

Studies on the Adsorption of Linear Alkylbenzene Sulfonate from Waste Water by Fibrous Aminated Acrylic ion-Exchanger (아민화 아크릴계 이온교환섬유의 폐수 중 Linear Alkylbenzene Sulfonate 흡착에 관한 연구)

  • 황택성;박진원;김원종
    • Polymer(Korea)
    • /
    • v.26 no.4
    • /
    • pp.516-522
    • /
    • 2002
  • The ion exchange characteristic of quaternary ammonium as functional group containing aminated acrylic fibrous ion exchanger were studied for the adsorption of linear alkylbenzene sulfonate (LAS) in a continuous ion exchange process. The adsorption capacities of aminated acrylic for LAS as the adsorption temperature were increased with increasing adsorption temperature and were equilibrated at $40^{\circ}C$. The maximum adsorption capacities as column packing ratio (L/D) were obtained at L/D>2. The adsorption capacity for LAS was increased with increasing pH and the maximum adsorption capacity as pH was obtained at pH 7. The effects of temperature and pH were similar to those of flow rate and concentration of LAS tin the breakthrough curves, the breakthrough time and slope of breakthrough corves decreased with increasing flow rate and concentration of LAS in adsorption process.

Comparison of CDI and MCDI applied with sulfonated and aminated polysulfone polymers

  • Kim, Ji Sun;Rhim, Ji Won
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.39-53
    • /
    • 2016
  • In this study, polysufone (PSf) was used as a base polymer to synthesize sulfonated polysulfone (SPSf) and aminated polysulfone (APSf) as cation and anion exchange polymers, respectively. Then the ion exchange polymers were coated onto the surface of commercial carbon electrodes. To compare the capacitive deionization (CDI) and membrane capacitive deionization (MCDI) processes, the pristine carbon electrodes and ionic polymer coated electrodes were tested under various operating conditions such as feed flow rate, adsorption time at fixed desorption time, and feed concentration, etc., in terms of effluent concentration and salt removal efficiency. The MCDI was confirmed to be superior to the CDI process. The performance of MCDI was 2-3 times higher than that of CDI. In particular, the reverse desorption potential was a lot better than zero potential. Typically, the salt removal efficiency 100% for 100 mg/L NaCl was obtained for MCDI at feed flow rate of 15 ml/min and adsorption/desorption time of 3 min/1 min and applied voltages 1.0 V for adsorption and -0.3 V for desorption process, and for 500 mg/L, the salt removal efficiency 91% was observed.

Study on the Operation Method of Ground Source Heat Pump System Considering Recovery of Ground Temperature (지중온도회복을 고려한 지열 히트펌프 시스템의 운전방법 검토)

  • Bae, Sangmu;Jeon, Jae-Young;Kwon, Young Sik;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.24-30
    • /
    • 2020
  • Ground source heat pump (GSHP) systems are actively introduced as cooling and heating conditioning systems of buildings due to annual stable performance and easily maintenance. However, ground temperature imbalance is occurred when the GSHP is used for a long period. Therefore, in this study, we proposed the operation method of the system that considered the recovery time of heat source temperature. The entering water temperature (EWT) and heat exchange rate (HER) were comparatively analyzed according to the continuous and intermittent operation. Furthermore, the underground thermal environment was evaluated by numerical analysis model. As the result, the intermittent operation was a maximum of 12.3% higher HER during the heating period than the continuous operation. In addition, the overall ground heat source temperature at the intermittent operation was higher than it at the continuous operation.

Thermal load analysis of tank culture system for applying seawater source heat pump (육상 수조식 양식장의 해수 열원 히트펌프 시스템 적용을 위한 열부하 분석)

  • Min-Gi YOON;Tae-Hoon KIM;Seok-Kwon JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.2
    • /
    • pp.155-163
    • /
    • 2023
  • This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.

Reduction Kinetics of Gold Nanoparticles Synthesis via Plasma Discharge in Water

  • Sung-Min Kim;Woon-Young Lee;Jiyong Park;Sang-Yul Lee
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.386-392
    • /
    • 2023
  • In this work, we describe the reduction kinetics of gold nanoparticles synthesized by plasma discharge in aqueous solutions with varied voltages and precursor (HAuCl4) concentrations. The reduction rate of [AuCl4]- was determined by introducing NaBr to the gold colloidal solution synthesized by plasma discharge, serving as a catalyst in the reduction process. We observed that [AuCl4]- was completely reduced when its characteristic absorption peak at 380 nm disappeared, indicating the absence of [AuCl4]- for ligand exchange with NaBr. The reduction rate notably increased with the rise in discharge voltage, attributable to the intensified plasma generated by ionization and excitation, which in turn accelerated the reduction kinetics. Regarding precursor concentration, a lower concentration was found to retard the reduction reaction, significantly influencing the reduction kinetics due to the presence of active H+ and H radicals. Therefore, the production of strong plasma with high plasma density was observed to enhance the reduction kinetics, as evidenced by optical emission spectroscopy.

A Study on Process Performances of Continuous Electrodeionization with a Bipolar Membrane for Water Softening and Electric Regeneration (바이폴라막을 이용한 연수용 전기탈이온의 공정 효율 및 전기적 재생에 관한 연구)

  • Moon, Seung-Hyeon;Hong, Min-Kyoung;Han, Sang-Don;Lee, Hong-Joo
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.210-218
    • /
    • 2007
  • CEDI-BPM(Continuous Electrodeionization-Bipolar Membrane) has advantages due to high ion permselectivity through ion exchange membranes and the production of $H^+$ and $OH^-$ ions on the bipolar membrane surfaces for regeneration of ion exchange resin during electrodeionization operation. In this study, hardness materials were removed by the CEDI-BPM without scale formation and the ion exchange resins were electrically regenerated during the operation. The adsorption characteristic of ion exchange resin surface, the influence of flow rate on the hardness removal and electric regeneration were investigated in the study. The removal efficiency of Ca was higher than that of Mg in the CEDI-BPM, which was related to the high adsorption capacity of Ca on the cation exchange resin. With increasing flow rate, the flux of Ca and Mg was enhanced by the permselectivity of a cation exchange membrane. In the electric regeneration of CEDI-BPM, it was shown that the regeneration efficiency was higher with a lower regeneration potential applied between cathode and anode.

Electrochemical nitrate reduction using a cell divided by ion-exchange membrane

  • Lee, Jongkeun;Cha, Ho Young;Min, Kyung Jin;Cho, Jinwoo;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • v.9 no.3
    • /
    • pp.189-194
    • /
    • 2018
  • Electrochemical reduction of nitrate was studied using Zn, Cu and (Ir+Ru)-Ti cathodes and Pt/Ti anode in a cell divided by an ion exchange membrane. During electrolysis, effects of the different cathode types on operating parameters (i.e., voltage, temperature and pH), nitrate removal efficiency and by-products (i.e., nitrite and ammonia) formation were investigated. Ammonia oxidation rate in the presence of NaCl was also determined using the different ratios of hypochlorous acid to ammonia. The operating parameter values were similar for all types of cathode materials and were maintained relatively constant. Nitrate was well reduced and converted mostly to ammonia using Zn and Cu cathodes. Ammonia, produced as a by-product of nitrate reduction, was oxidized in the presence of NaCl in the electrochemical process and the oxidation performance was enhanced upon increasing the hypochlorous acid-to-ammonia ratio to 1.09:1. Zn and Cu cathodes promoted the nitrate reduction to ammonia and the produced ammonia was finally removed from solution by reacting with hypochlorite ions. Using Zn or Cu cathodes, instead of noble metal cathodes, in the electrochemical process can be an alternative technology for nitrate-containing wastewater treatment.

A Simple Preparation of Monoiodobromosulfophthalein-$^{131}$ I by Isotope Exchange for Medical Use

  • Kim, Jaerok;Kim, Tae-Ho
    • Nuclear Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.1-6
    • /
    • 1977
  • Monoiodobromosulfophthalein-$^{131}$ I (MIBSP-$^{131}$ I), one of the useful radiopharmaceuticals for liver function studies, has been prepared by a simple isotope exchange between the MIBSP and the molecular iodine-$^{131}$ I in phosphate buffer, pH 5.3. The pooled cold MIBSP was prepared by a normal iodination of BSP using iodine monochloride, and separated from the iodination mixture by applying a Sephadex LH-20 chromatography. At 10$0^{\circ}C$, the exchange rate was so fast that the reaction could be terminated in 5 min to show upto 95% yield. The final product could be obtained simply by further heating for about 5 min in a boiling water bath in the presence of a small amount of hydrogen peroxide, and subsequent pH adjustment and membrane filtration.

  • PDF

Column regeneration for Partisil/Partisphere ion-exchange columns (Partisil/Partisphere 이온 교환 컬럼 재생 가이드)

  • Mark Fever;Gemma Howse
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.5.1-5.3
    • /
    • 2024
  • The document discusses the regeneration of Partisil/Partisphere ion-exchange columns in chromatography. It mentions that column efficiency can diminish with use due to the accumulation of sample and/or mobile phase impurities at the head of the column. This can lead to a change in back pressure, lower column efficiency, and sometimes a change in selectivity. The document outlines a procedure that may restore column performance. The document also provides everyday practices to enhance the lifetime of a column. These include using only high-purity HPLC solvents and buffers, using freshly prepared mobile phases and buffers, filtering mobile phases to remove particulates, using appropriate sample clean-up procedures, using a guard column or pre-column filter, and working within the pressure and flow rate limitations of the column. For the regeneration of Partisil/Partisphere SAX, SCX, WAX, and WCX columns, the document suggests passing 20 column volumes of various mobile phases through the column. These include a buffer wash, distilled water, an acid wash, a chelating wash, a methanol wash, and a buffer for separation. The document emphasizes that not all of these wash steps are required for every column clean-up and that some chromatographers require only a combination of certain steps.

  • PDF

Dissolved Oxygen Budget in Floating Net Cage of Fish Farm at the Coastal Area -In case of yellow tail farm in Konli-Do- (해산 어류 양식장 가두리의 DO수지 -곤리도 방어 양식장의 경우-)

  • KIM Yong Sool
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.1
    • /
    • pp.30-34
    • /
    • 1988
  • In roastal fish farms the farmers, especialy engaging in dealing with the floating cage culture, going to know about relationships between holding capacity and water quality in cage. Some of water quality managers and specialists studing physiological ecology understand that the key of water quality management concerned fish farming is budget of dissolved oxygen. This paper deals with oxygen budget in floating cage of the yellow tail farms at southern coastal area in Korea. The sampling station is located at Konli-Do fish farm near Chungmu, and the data is collected for 24 hours from 3:00 p.m. 8th September 1987. In result, the needed oxygen coming after the consumption by the rearing fish had been supplied with the tide current exchange, the sum of oxygen produced by phytoplankton photosynthesis and diffused from atmosphere are no more that $43\%$ for the needs of sea water consumption included respiration of planktons and decomposition of organic matters. The optimum holding capacity of cage is possible to compute with the calculation of minimum diurnal water exchange rate $[Qin{\cdot}V^{-1}\;(C-\bar{c})]$ through net mesh of cage.

  • PDF