• 제목/요약/키워드: Water exchange

검색결과 1,492건 처리시간 0.04초

지중열 이동 시뮬레이션을 이용한 수평형 지열시스템의 채열성능 예측 (Prediction of the Heat Exchange Rate for a Horizontal Ground Heat Pump System Using a Ground Heat Transfer Simulation)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.297-302
    • /
    • 2013
  • The ground source heat pump (GSHP) system has attracted attention, because of its stability of heat production, and the high efficiency of the system. However, there are few studies on the prediction method of the heat exchange rate for a horizontal GSHP system. In this research, in order to predict the performance of a horizontal GSHP system, coupled simulation with a ground heat transfer model and a heat exchanger circulation model was developed, and calculation of heat exchange rate was conducted by the developed tool. In order to optimally design the horizontal GSHP system, the flow rate of circulation water, and the depth and buried spaces of heat exchangers were considered by the case study. As a result, the temperature of circulation water and the heat exchange rate of the system were calculated in each case.

백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구 (Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction)

  • 왕쩐후안;전종균;권영철
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

수전해용 분리막 연구 동향 및 전망 (Research Trend and Prospect of Membranes for Water Electrolysis)

  • 이재훈;조원철;김창희
    • 공업화학전망
    • /
    • 제24권4호
    • /
    • pp.1-21
    • /
    • 2021
  • 화석연료의 과도한 사용으로 유발된 기후변화 문제를 해결하기 위해 대체에너지의 개발에 대한 관심이 높아지고 있는 가운데 재생가능하며 친환경적인 수소에너지가 실현가능한 궁극적 대안으로 주목받고 있다. 다양한 수소 생산 기술 중 물의 전기분해를 이용한 수전해 기술은 온실가스와 같은 오염물질을 배출하지 않으며 재생에너지와 연계하여 미이용 전력을 대용량 장주기로 저장할 수 있다는 장점이 있다. 수전해 장치는 수소와 산소를 발생하는 전극과 기체의 섞임을 방지하고 이온을 전달하는 분리막으로 구성되며 그 중 분리막은 수전해 장치의 효율과 안정성을 결정짓는 핵심 부품이다. 본 총설에서는 수전해 기술 중 저온 수전해에 해당하는 알칼라인 수전해(alkaline water electrolysis), 고분자전해질막 수전해(polymer electrolyte membrane water electrolysis)와 음이온교환막 수전해(anion exchange membrane water electrolysis)에 사용되는 분리막에 대한 특성을 분석하고 최근 연구 동향에 대해서 다루고자 한다.

지르코늄 메조기공 구조체를 이용한 수중의 인 제거 (The Phosphorus Removal from Water by Zirconium Mesoporous Structure)

  • 이병천;이관용;이상협;최용수;박기영
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.455-461
    • /
    • 2005
  • This study was designed to investigate the fundamental aspects of a possible recovery of phosphorus strategy from wastewater by using the zirconium mesoporous structured materials as a new type of ion exchangers. Zirconium mesoporous structure material was synthesized by hydro-thermal synthesis. The synthesized zirconium mesoporous structure was examined by X-ray diffraction (XRD) and Transmission electron micrograph (TEM). From the results of XRD and TEM, it was found out that hexagonal mesoporous structure, pore size was about $47{\AA}$, was synthesized. Experimental results showed that the complex of zirconium sulfate tetrahydrate and surfactant micelles had very high ability for capture of phosphorus. The amount of phosphate ions exchanged into the solid was as great as 3.4mmol/g-ZS. And the ion exchange reaction was occurred between $PO_4{^{3-}}$ and $SO_4{^{2-}}$ and also between $PO_4{^{3-}}$ and $OH^-$. Therefore, it is possible to get the higher removal efficiency than other ion exchange media and adsorbent.

Hematological Responses, Survival, and Respiratory Exchange in the Olive Flounder, Paralichthys olivaceus, during Starvation

  • Park, I.S.;Hur, J.W.;Choi, J.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권9호
    • /
    • pp.1276-1284
    • /
    • 2012
  • A 12-wk experiment was conducted to examine the hematological changes, survival, and respiratory exchange in the olive flounder, Paralichthys olivaceus, during starvation. The growth, survival and respiratory exchange rates of the starved group were lower than those of the fed group during the experiment. Blood analysis, including hematocrit, hemoglobin, red blood cells, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and mean corpuscular volume, did not differ significantly (p>0.05) between the fed and starved groups at the end of the experiment. There were no significant differences in plasma cortisol, glucose, $Na^+$, $Cl^-$, $K^+$, or aspartate aminotransferase between the fed and starved groups (p>0.05). Alanine aminotransferase levels were higher in the starved group than in the fed group, whereas plasma osmolality was lower in the starved group than in the fed group. It was shown that starved fish had various problems after four weeks, which did not occur in the fed group. Long-term starvation is infrequent in aquaculture farms. However, starvation studies of this kind are very useful for a basic understanding of how physiological changes affect fish health, life expectancy, and growth.

Speciation of Cr(III)/Cr(VI) in Tannery Waste Waters by Using Ion-Exchange Resins

  • Kartal, S.;Tokalloglu, S.;Ozkan, B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권5호
    • /
    • pp.694-698
    • /
    • 2006
  • A method has been described for the chemical speciation, preconcentration and determination of Cr(III) and Cr(VI) species in filtered tannery waste waters by flame atomic absorption spectrometry using ion-exchange resins. Amberlite IR-120($H^+$) strongly acidic cation exchanger and Amberlite IRA-410($CI ^-$) strongly basic anion exchanger resins were used for the separation and preconcentration of Cr(III) and Cr(VI) species, respectively. Optimum condition for preconcentration and speciation was obtained by testing pH of sample and eluent, flow rates of sample and eluent, amount of resins, volume of sample and eluents, and effect of foreign ions. The recommended method has been successfully applied for the preconcentration and determination of chromium species in the dissolved phase of waste water samples collected from a tannery waste water treatment plant in Kayseri, Turkey. The detection limits achieved were 0.73 $\mu$g/L for Cr(III) and 0.81 $\mu$g/L for Cr(VI). Recovery studies showed 99% for Cr(III) and 98% for Cr(VI), for samples spiked with single species.

Reuse of Oyster Shell Waste as Antimicrobial Water Treatment Agent by Silver Ion Exchange

  • Jo, Myung-Chan;Byeong-II Noh;Shin, Choon-Hwan
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권3호
    • /
    • pp.185-193
    • /
    • 2000
  • A water treatment agent with antimicrobial activity(Ag-Os) was created by exchanging silver ion($Ag^{+}$) on calcined oyster shell powder. The desorption of the exchanged silver ion was negligible, thereby indicating a stable antimicrobial water treatment agent. The sterilization effect of Ag-Os on underwater microorganisms was then investigated. An MIC (Minimum Inhibitory Concentration) test result indicated that Ag-Os had an excellent sterilization effect on G-germs, such as Escherichia coli and Pseudomonas aeruginosa. Most germs were annihilated with an Ag-Os concentration of 200 ppm and contact time of 60 minutes. The sterilization effect was mainly dependent on the contact time. The zeta potential of the Ag-Os powder adsorbed on sand was measured relative to the concentration of exchanged silver ion. As the concentration of the exchanged silver ion increased, the surface charge density of the anions on the surface of the Ag-Os powder adsorbed on sand also increased. Accordingly, this result indicated that a higher silver ion than ion exchange capacity was present on the particle surface due to adsorption. Consequently, this increased concentration of exchanged silver ion would appear to significantly enhance the sterilization power.

  • PDF

식물생장용 LED 램프의 적정 수냉조건 및 열교환량 분석 (Analysis of Optimum Water Cooling Conditions and Heat Exchange of LED Lamps for Plant Growth)

  • 박종호;이재수;김동억;김용현
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.334-341
    • /
    • 2011
  • This study was conducted to compare the characteristics of heat dissipated from LED lamps with water cooling method and natural cooling method in a closed-type plant production system (CPPS) and to determine the optimum water temperature and flow rate for LED lamps with water cooling method. The experiments were performed in CPPS maintained at temperature of $24^{\circ}C$ and humidity of 70%. As compared to the LED lamps operated at water temperature of $22.5{\pm}1.2^{\circ}C$ and flow rate of $1,521{\pm}3.3\;mL{\cdot}min^{-1}$, air temperature under LED lamps with natural cooling was approximately increased by $1^{\circ}C$ and photosynthetic photon flux was decreased by $10{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. PPF illuminated from LED lamps was affected by forward voltage varied by the surface temperature of LED lamps. Forward voltage of LED lamps was decreased with increasing surface temperature and then PPF was proportionately decreased. Five levels ($14^{\circ}C,\;17^{\circ}C,\;20^{\circ}C,\;23^{\circ}C,\;26^{\circ}C$) of water temperature and three levels ($500\;mL{\cdot}min^{-1}$, $1,000\;mL{\cdot}min^{-1}$, $1,500\;mL{\cdot}min^{-1}$) of flow rate were provided to analyze the change of surface temperature and heat exchange of LED lamps. Heat exchange was increased with decreasing water temperature and increasing flow rate. At flow rate of $1,000-1,500\;mL{\cdot}min^{-1}$ and water temperature of 22.0-$22.6^{\circ}C$, surface temperature of LED lamps can be approached to $24^{\circ}C$ that was almost same as air temperature in CPPS. The calorific value generated from LED lamps used in the study was estimated to be $103.0\;kJ{\cdot}h^{-1}$.