• 제목/요약/키워드: Water exchange

검색결과 1,492건 처리시간 0.038초

Soil Physical and Chemical Properties of Forest-Fired Area in Koseong, Kangwon (강원도 고성 산화지역의 토양 이화학성 변화)

  • Nam, Yi;Min, Ell-Sik;Jang, In-Soo
    • Korean Journal of Environment and Ecology
    • /
    • 제14권1호
    • /
    • pp.38-45
    • /
    • 2000
  • This research has been done to investigate influence of soil physical and chemical properties on forest environmental change by fired pine forest in Koseong, Kangwondo. The sample sites were divided by not-fired sites(NF), not-cutting site after fired(FNC), cutting and planting sites after fired(FCP) and cutting and not-planting sites after fired(FC). Soil texture of whole sites was sandy clay loam. Sand content of NF top soil were lower than those of sub soil and clay content were higher, while FNC, FCP and FC sand content of top soil were higher than those of sub soil. Total porosity didn't differ between the sites. Coarse porosity and permeability had the increasing order as NF> FNC> FCP> FC, but fine porosity and bulk density had the opposite trends. Because forest fire removed the vegetation and then soil erosion was accelerated, forest environmental changes by forest fire greatly degraded soil porosity and permeability which were indices for forest water retention, so that soil physical properties were deteriorated. Both top and sub soil pHs of NF and FNC were higher than those of FCP and FC. Organic matter content and total nitrogen content of top and sub soils were high in order as NF> FNC> FCP> FC. Cation exchange capacities and exchangeable cation(K+, Na+, $Ca^2$+, $Mg^2$+) content in top soils were higher than those in sub soils, and in order as NF> FNC> FCP> FC, to be compared by the sites. Those mean that forest fire result from the erosion of top soil layers.

  • PDF

Environmental Geochemistry of Radon at the Taejon City Area in Korea (대전시(大田市) 지역(地域) 라돈 환경(環境) 지화학(地化學) 연구(硏究))

  • Hong, Young-Kook
    • Economic and Environmental Geology
    • /
    • 제30권1호
    • /
    • pp.51-60
    • /
    • 1997
  • The high radon (Rn222) potentials of soil, groundwater, hotspring and indoor environments in the Taejon city area were delineated by use of an EDA RDA-200 radon detector. The U and Th contents were also analysed using a Multi Channel Analyzer to illustrate the sources of the radon potentials. The average U concentrations in Taejon vary according to the type of granites such as $4.14{\pm}2.36ppm$ in schistose granite (SG), $3.13{\pm}1.70ppm$ in biotite granite (BG) and $3.01{\pm}1.95ppm$ in two mica granite (TG). The U contents in the granites are closely related with the amounts of uraniferous minerals. However, the U contents in the soil are found to be $5.05{\pm}4.75ppm$ in TG, $4.07{\pm}1.69ppm$ in BG and $3.87{\pm}1.91ppm$ in SG which are mainly explained by the different cation exchange capacities (CEC) of the soils from various granites. The levels of soil radon are $552{\pm}656pCi/l$ in SG, in which levels at two locations exceed the level of 1,350 pCi/l established as guideline for follow-up action by the U.S. Environmental Protection Agency (EPA), $443{\pm}284pCi/l$ in TG and $224{\pm}115pCi/l$ in the BG. The soil radon concentrations are found to be proportional to the U content and hardness of the soils. The groundwater radon concentrations in the domestic wells of - 30~-100 m depth show that $6,907{\pm}4,665pCi/l$ in TG, $5,503{\pm}6,551pCi/l$ in SG and $2,104{\pm}1,157pCi/l$ in BG which are positively related with U contents in soils. The radon levels of six groundwater wells in TG and two in SG are greater than guideline for drinking water level, 10,000 pCi/l by EPA (1986). Average radon contents of hotsprings and public bathes in the TG area are $7,071{\pm}1,942pCi/l$ and $1,638{\pm}709pCi/l$, respectively, which are below the EPA standard for remedial action value of the 10,000 pCi/l. The mean indoor radon concentrations of the TG and SG areas are $1.60{\pm}1.20pCi/l$ and $1.60{\pm}0.70pCi/l$, respectively. The elevated indoor radon levels of 5.6 pCi/l and 6.7 pCi/l are found to be particularly in TG area, which exceeds 4 pCi/i guideline, correlating positively with the U contents in the soil and radon concentration in the groundwater.

  • PDF

Physicochemical Properties of Wheat Bran in Different Areas Prepared by a High-pressure Homogenizer Process (고압균질처리에 따른 산지별 밀기울의 이화학적 특성)

  • An, Eun-Mi;Lee, Jae-Kang;Choi, Yong-Seok;Kim, Young-Hwa;Shin, Han-Seung
    • Korean Journal of Food Science and Technology
    • /
    • 제46권4호
    • /
    • pp.404-409
    • /
    • 2014
  • In this study, the effects of high-pressure homogenizer treatment on the physicochemical properties of wheat bran from different areas were evaluated. The results showed that the high-pressure homogenizer process could effectively decrease particle size and loosen the microstructure of the wheat bran matrix. As the particle size decreased, the bulk density of wheat bran was significantly decreased (p<0.05) and the water-holding capacity, swelling capacity, oil-holding capacity, and cation-exchange capacity were substantially increased. In addition, microscopic analysis revealed the gradual disintegration of the original cell wall structure and the dissociation of bran tissues over the course of high-pressure homogenization treatment. Scanning electron micrographs showed that the process could also effectively separate out the structural components of wheat bran. These results suggest that the high-pressure homogenizer process is an effective method to modify the physicochemical properties of wheat bran and likely other cereal brans, which might provide potential fiber-rich ingredients for use in functional foods.

Electrochemical Properties of Kaolinite in Aqueous Suspension (수용액중(水溶液中)에서의 Kaolinite 입자(粒子)의 전기화학적(電氣化學的) 성질(性質))

  • Lim, Hyung-Sik;Baham, J.;Volk, V.V.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • 제16권4호
    • /
    • pp.318-324
    • /
    • 1983
  • Electrochemical properties of Georgia kaolinite in aqueous suspension were studied by ion adsorption, potentiometric titration, and electrophoretic mobility measurements. Kaolinite in 0.001 M and 0.1 M NaCl solution showed qualitatively both pH independent and pH depender negative and positive charges through pH range 2.5-11.0 when dissolved aluminum ions from kaolinite were considered as well as $Na^+$ and $Cl^-$ as index ions. Electrophoretic mobilities (EM) of 0.02 wt. % kaolinite suspension in distilled water and 0.001 M NaCl solution were approximately constant against mobility measuring time consumed in the electrophoresis cell at different pH values, and isoelectric points(IEP) were around pH 4.7. EM values in 0.1 M NaCl solution were positive and constant against mobility measuring time below pH 4; but above pH 4, EM values were negative for the first 10 seconds followed by positive values which became approximately constant through stepped changes after 10 minutes. Hydrated cations may bind to the six- member oxygen ring sites having multiple partial negative charges on the exterior tetrahedral layer surface by both electrostatic and hydrogen bonding force while hydrated anions bind to the partially positively charged hydrogen atoms on the exterior octahedral layer surface. Parts of the aluminol groups on the exterior octahedral layer surface as well as edge faces may be involved in complex reactions and have both anion and cation exchange capacities in the electrolyte solution above pH 4.

  • PDF

Preparation and Characterization of the Impregnation to Porous Membranes with PVA/PSSA-MA/THS-PSA for Fuel Cell Applications (연료전지 응용을 위한 다공성막에 가교된 PVA/PSSA-MA/THS-PSA의 함침을 통한 고내구성 이온교환막의 제조 및 특성 연구)

  • Kim, Il-Hyoung;Kim, Sung-Pyo;Lee, Hak-Min;Park, Chan-Jong;Rhim, Ji-Won;Cheong, Seong-Ihl
    • Membrane Journal
    • /
    • 제21권3호
    • /
    • pp.299-305
    • /
    • 2011
  • This study deals with the preparation of polymeric electrolyte membranes having high durability for the application of fuel cells. The membranes under investigation were prepared the impregnation to porous polyethylene membranes with poly(vinyl alcohol)(PVA), poly(styrene sulfonic acid-co-maleic acid), and (PSSA-MA)3-(trihydroxysilyl)-1-propanesulfonic acid (THS-PSA). To characterize the resulting membranes, the water contents, the contact angles, FT-IR, the proton conductivity and the the modulus were measured. The proton conductivity of 30% content of THS-PSA at $55^{\circ}C$ gave excellent $1.27{\times}10^{-1}S/cm$ and the mechanical strength was improved 7 times higher up to the THS-PSA content 15%, as a result, the durability was elevated extensively.

Preparation and Characterization of PVdF Microporous Membranes with PEG Additive for Rechargeble Battery (Poly(ethylene glycol)를 첨가한 이차전지용 poly(vinylidene fluoride) 미세다공성 분리막의 제조와 물성)

  • Nam, Sang-Yong;Jeong, Mi-Ae;Yu, Dae-Hyun;Koh, Mi-Jin;Rhim, Ji-Won;Byun, Hong-Sik;Seo, Myung-Su
    • Membrane Journal
    • /
    • 제18권1호
    • /
    • pp.84-93
    • /
    • 2008
  • Poly(vinylidene fluoride) has received much attention in the last several years for the lithium secondary batteries. In this study, to enhance the porosity, PVdF was prepared by phase inversion method using as an additive, PEG (poly(ethylene glycol)), with N,N-dimethylformamid as a solvent. The pores are generated during the solvent and non-solvent exchange process in the coagulation bath filled with non-solvent (distilled water). The surface and cross-section of the membranes were observed with a scanning electron microscopy (SEM). The mechanical property of the membrane was determined by using an universal testing machine (UTM) and thermal property was verified by heat shrinkage. Uniformed sponge structure of PVdF-PEG membrane for the lithium secondary batteries was prepared with 10 wt% of PEG concentration in the PVdF-PEG solution. Porosity, elongation and tensile strengh of the membrane were 87%, 75.45%, and 275. 27 MPa respectively.

Desalination of Tuna Boiled Extract by Electrodialysis (전기투석에 의한 참치 자숙액의 탈염특성)

  • KIM Se-kwon;BYUN Hee-Guk;JEON You-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제32권1호
    • /
    • pp.68-74
    • /
    • 1999
  • The optimum conditions for selective .elimination of salt from tuna boiled extract (TBE) by electrodialysis were determined. The desalination conditions of TBE were determined at various pH's, concentrations and volumes of TBE. The ion-exchange membrane with a molecular weight cut off 100Da was used for desalting of TBE. The desalination times on $1\%$ and $10\%$ of TBE concentrations were 40 min and 240 min, respectively. The electrodialysis process could removed above $95\%$ of the initial salt content in $1\%$ and $10\%$ of TBE concentrations. The desalination of TBE at pH 4.0 was $14\%$ higher than that at pH 9.0 The amount of water transferred by the electrodialysis was determined. The electrodialysis process could remove above $90\%$ of the initial salt content in $5\%$ TBE for 80 min. The initial volume and the permeate did not have significant effects on desalination time and ratio. The key parameters for the desalination of TBE were pH and concentration of TBA.

  • PDF

A Calculation Method of in vivo Energy Consumption in Estimation of Harvesting Date for High Potato Solids (고 고형분함량 감자의 수확시기 예측모형을 위한 식물체내 에너지 소모량 추정)

  • Jung, Jae-Youn;Suh, Sang-Gon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • 제55권4호
    • /
    • pp.284-291
    • /
    • 2010
  • A simulation modeling for predicting the harvesting date with high potato solids consists of development of mathematical models. The mathematical model on potato growth and its development should be obtained by using agricultural elements which analyze relations of solar radiation quantity, temperature, photon quantity, carbon dioxide exchange rate, water stress and loss, relative humidity, light intensity, and wind etc. But more reliable way to predict harvesting date against climatic change employs in vivo energy consumption for growth and induction shape in a slight environmental adaptation. Therefore, to calculate in vivo energy loss, we take a concept of estimate of the amount of basal metabolism in each tuber on the basis of $Wm={\int}^m_tf(x)dt$ and $Tp=\frac{Tm{\cdot}Wm^{Tp}}{Wm^{Tm}}$. In the validation experiments, results of measuring solid accumulation of potato harvested at simulated date agreed fairly well with the actual measured values in each regional field during the growth period of 2005-2009. The calculation method could be used to predict an appropriate harvesting date for a production of high potato solids according to weather conditions.

Numerical Simulations for Optimal Utilization of Geothermal Energy under Groundwater-bearing Conditions (지하수 부존지역에서 최적 지열에너지 활용방식 수치 모의)

  • Kim, Jin-Sung;Cha, Jang-Hwan;Song, Sung-Ho;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • 제24권4호
    • /
    • pp.487-499
    • /
    • 2014
  • While the vertical open type of heat exchanger is more effective in areas of abundant groundwater, and is becoming more widely used, the heat exchanger most commonly used in geothermal heating and cooling systems in Korea is the vertical closed loop type. In this study, we performed numerical simulations of the optimal utilization of geothermal energy based on the hydrogeological and thermal properties to evaluate the efficiency of the vertical open type in areas of abundant groundwater supply. The first simulation indicated that the vertical open type using groundwater directly is more efficient than the vertical closed loop type in areas of abundant groundwater. Furthermore, a doublet system with separated injection and extraction wells was more efficient because the temperature difference (${\Delta}$) between the injection and extraction water generated by heat exchange with the ground is large. In the second simulation, we performed additional numerical simulations of the optimal utilization of geothermal energy that incorporated heat transfer, distance, flow rate, and groundwater hydraulic gradient targeting a single well, SCW (standing column well), and doublet. We present a flow diagram that can be used to select the optimal type of heat exchanger based on these simulation results. The results of this study indicate that it is necessary to examine the adequacy of the geothermal energy utilization system based on the hydrogeological and thermal properties of the area concerned, and also on a review of the COP (coefficient of performance) of the geothermal heating and cooling system.

Analysis of Growth Condition and Some Suggestions for Its Maintenance of Legally Protected Trees Grown in Pyungtack City, Kunggi Province, Korea (경기도 평택시 보호수의 생육실태와 관리방안 연구)

  • Lee, Jong-Bum;Doo, Chul-Eon;Lee, Jae-Keun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • 제15권3호
    • /
    • pp.45-54
    • /
    • 2012
  • This study intended to analyze growth condition of each object by protected tree's ground for 45 places registered to Pyeongtaek protected tree list in locational characteristics, conduct exchange analysis for impediment extent rate in crown area and tree type to the result and suggest the measures to manage artificial impediment which is an effect on protected tree condition. In this study, the tree whose area of impediment for crown area is less than 21% is tree condition of grade 1~2, less than 21~50% is grade 2~3 and more than 50% is grade 3~5. The more impediment is, the more inconvenience causes on growth and development. So, it verified that the area rate must maintain less than 21% for the root system management of protected tree. For the standard of managing artificial impediment which is an effect on the tree condition of protected trees, the below matters intend to be suggested. The first, the impediment in crown area should be less than 21%. But, if there is not artificial impediment out of crown area, the rate of impediment area is considered to increase somewhat. The second, growth space of protected tree should be maintained by crown area at least and impediment should be established out of the crown area. The third, during the national project and land development, surroundings of protected tree must be applied as park, resting place, etc. and the establishment area of impediment (artificial impediment and natural impediment) in crown area must be limited. The forth, publicity for regional people (especially, land owner) is necessary for the protection of natural inheritance and the value of dependence on local government and village which are the subject of management must be announced widely through the internet media, etc, so its importance must be recognized. The fifth, the matters related to protected tree management must be able to limit artificial damage which is for surroundings of protected tree through the mutual connection among the local governments; construction, civil engineering, architecture, water and sewage, agriculture and forest and others. Also, following studies on the effects of kinds, thickness, etc. of impediment around the protected tree on trees should be continued.