• 제목/요약/키워드: Water district

검색결과 597건 처리시간 0.031초

용수구역 물 관리를 위한 표준화 물수지 모형 개발 (Development of Standardized Water Balance Model for Applying Irrigation District in South Korea)

  • 노재경;이재남;김용국
    • 농업과학연구
    • /
    • 제37권1호
    • /
    • pp.105-112
    • /
    • 2010
  • The objective of this study is to develop a standardized model for analyzing water balances in large scaled water basin by considering agricultural water districts, and to evaluate the hydrological feasibility of applying this model to several water districts such as Nonbul, Geumbok, Daejeon 1, Daejeon 2, and Cheonggang in Geum river basin. Ten types of stream network were considered in developed model. Using this model, streamflows were simulated by major stations and water balances were analyzed by water districts. Simulated streamflows and measured streamflows were compared at check stations such as Gapcheon and Bugang stations in which Nash and Schcliffe's model efficiencies were 0.633, 0.902, respectively. This results showed its applicabilities to national water resources plan, rural water development plan, and total maximum daily load plan in Korea.

미래의 불확실한 냉방부하에 대한 아이스슬러리를 이용한 지역냉방시스템 및 경제성 평가 (A District Cooling System using Ice Slurry for the Uncertain Cooling Load of the Future and its Economic Evaluation)

  • 이윤표;안영환;윤석만
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.776-782
    • /
    • 2006
  • A new district cooling system using ice slurry for the uncertain cooling load of the future is presented. The chilled water produced by the absorption chillers is used for the base cooling load. The temperature of the chilled water is reduced by mixing of ice slurry depending on increasing of the cooling load. Finally, IF of the ice slurry is increased up to 10% at the peak load. The transporting mass flow rate is decreased down to 44.7%, and the diameter of the main pipe is decreased down to 66.7%, but the diameter of the branched pipe is designed as the same size of the chilled water.

자원순환형 소각열 이용시스템에 관한 평가 (Evaluation on Utilizing Systems of Incineration Heat as Resource cycling Type)

  • 정용현
    • 한국환경과학회지
    • /
    • 제12권4호
    • /
    • pp.503-510
    • /
    • 2003
  • How to plan the energy system is one of the keys f3r constructing the Environment -Friendly City. for this reason, a great number of surveys for utilizing unused energy have conducted by a planner. In regard to unused energy, the heat from incineration plants classify as a unused energy having high-exergy-energy. From this point of view, It is studied about the plant systems providing heat to district heating & cooling(D.H.C) and producing electric power. It is divided four system models as system I (10K [kgf/cm$^2$) vapor as outlet of boiler, supply far 10K vapor and return to 60$^{\circ}C$ as supply condition of district heating), system II (30 K vapor as outlet of boiler, supply for 5t vapor and return to 60f as supply condition of district heating), system 111 (30 K vapor as outlet of boiler, supply for 85$^{\circ}C$ hot water and return to 60$^{\circ}C$ as supply condition of district heating), system IV (30 K vapor as outlet of boiler, supply for 47$^{\circ}C$ hot water and return to 40t as supply condition of district heating). The results from the upper condition of four system, System II got a proper on economical benefits and system IV calculated as benefiting on energy saving effects, and suggest indifference curve as the total evaluation method of both economical benefits and energy saving.

세미워터제트형 연안어선 개발에 관한 연구 (A Study on the Development for the Coastal Fishing Boat attached Protected-Tunnel for Propeller)

  • 고재용;심상목;박충환;서성부;배동균
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2003년도 춘계공동학술대회논문집
    • /
    • pp.16-20
    • /
    • 2003
  • 최근 어선어업 주변환경의 급속한 변화는 기존 어선어업의 구조조정과 새로운 사회, 경제적 환경에 부응하는 선형개발의 요구로 이어지고 있다. 한편, 서ㆍ남해 연안에서 작업 및 항해하는 연안어선들은 노출된 프로펠러에 어망, 로프 등이 감기는 사고가 매년 증가하고 있는 실정이다. 본 연구는 이상과 같은 관점에서 연안어선의 해난사고 방지를 위해 기존 선미형상을 수정한 프로펠러 보호터널 부착 연안어선을 대상으로 모형시험을 통하여 세미워터제트형 연안어선의 주요성능을 분석, 검토한 것이다.

  • PDF

단지계획지구 홍수저류지의 하천유지유량 공급방안 연구 (A Feasibility Study on Supplying Stream Minimum Flow Using Detention Storage in Developing Planned District)

  • 노재경;박현구
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1219-1223
    • /
    • 2005
  • This study was accomplished to confirm the possibility of supplying stream minimum flow from detention storage which was determined to reduce peak flows of flood within developing planned district. The results analyzed was summarized as follows; Firstly, Sin-gil district situated in Ansan city was selected, of which watershed area has $0.56km^2$. And detention storage was determined to $5,370m^3$ from analyzing flood volume by the SCS unit hydrograph method. Secondly, using Visual Basic ver 6.0, a detention storage water balance model was developed, in which simulation was based on conditioning storage inflow and outflow according to streamflow volume or rate state. And streamflow was simulated using the DAWAST model. Thirdly, detention operation scenarios were consisted of the combinations with inflow referencing streamflow of 5mm/day, 10mm/day and outflow referencing streamflow of 1mm/day, 2mm/day. The developed detention storage water balance model was operated to simulate daily water storages of detention sized on flood by scenarios. Stream minimum flows were able to be supplied during 209 days to 237 days per a year, total volume of stream minimum flows supplied for this period was analyzed to reach 27 to $55\% of yearly streamflow volume. If inflow criteria of streamflows to detention was considered to be established on a theoretical condition, it is expected to supply stream minimum flows of 20 to $30\% of yearly streamflow from stream to detention. Also to maximize function of supplying urban stream minimum flow from detention storages, sewage waters within developing planned district have to be treated and entered to detention inflow together with streamflows to enrich function of detention planned to reduce flood volumes.

  • PDF

수돗물불소농도조정사업이 지역주민의 골밀도에 미치는 영향 (The Effect of Adjusted Water Fluoridation on Bone Mineral Density)

  • 한윤정;민진영;한동헌;김현덕;백도명
    • 한국환경보건학회지
    • /
    • 제34권4호
    • /
    • pp.261-270
    • /
    • 2008
  • Adjusted water fluoridation has been disputed because of its various effects on human health. Previous studies have been concerned with the difference in bone mineral density (BMD) between water fluoridated (WF) and none water fluoridated (NWF) districts. The aim of this study is to examine whether water fluoridation affects BMD. BMD was measured by dual energy X-ray absorptiometry (DXA). 386 adults(174 males and 212 females) in Ansan (WF) district and 399 adults (176 males and 223 females) in Sihwa (NWF) district, participated in this study. The Ansan and Sihwa districts are similar in residential environment and living class. The relationship between serum fluoride concentration and BMD was also examined by analysis of the serum fluoride concentrations from 402 inhabitants of the Ansan district. In females, the BMD of subjects living in Ansan ($0.457{\pm}0.008$) was a little higher than that of Sihwa subjects ($0.446{\pm}0.008$), although it is not significant, after adjusting for BMI, physical activity level, educational achievement, smoking volume, menopause status, and number of births. However, the BMD of Ansan subjects ($0.532{\pm}0.020$) in their forties was statistically higher than that of Sihwa (0.498{\pm}0.019). No relationship was found in males. In residential periods, there was significant difference (Ansan $0.467{\pm}0.013$, Sihwa $0.434{\pm}0.012$, p=0.0125) in the BMD between females of two districts, particularly in the group of over 6 year long-term inhabitants. On the contrary, there was no remarkable difference in males from the two districts. Serum fluoride concentrations in females were associated with BMD, especially in the age group of forties (p=0.0457). No relationship was observed in the male group. Analysis of adult BMD over the age of 20 in a water fluoridated and a none water fluoridated district, confirms more or less a higher BMD in the water fluoridated (WF) district, especially for females. It is assumed that the difference between two districts came somewhat from the effect of water fluoridation.

농업용 저수지 용수공급 모의 시스템의 개발 (Development of agricultural reservoir water supply simulation system)

  • 전상민;강문성;송인홍;송정헌;박지훈;기우석
    • 농촌계획
    • /
    • 제20권2호
    • /
    • pp.103-114
    • /
    • 2014
  • The objective of this study was to develop agricultural reservoir water supply simulation system to assess water cycle of agricultural water district. Developed system was named as ARWS (Agricultural Reservoir Water supply simulation System). ARWS consists of platform and independent modules. In ARWS, reservoir inflow was calculated using Tank model, and agricultural water supply was calculated considering current farming period and mid-summer drainage. ARWS was applied to simulate water level of Gopung and Tapjung reservoir in 2011 - 2012. The results were compared to simulation results of HOMWRS and observed data. Average $R^2$, EI, RMSE of ARWS were 0.76, 0.46, 1.78 (m), average $R^2$, EI, RMSE of HOMRWS were 0.88, -0.14, 2.37 (m) respectively. Considering statistical variances, water level simulation results of ARWS were more similar to observed data than HOMWRS. ARWS can be useful to estimate reservoir water supply and assess hydrological processes of agricultural water district.

냉방부하 수요 창출을 통한 효율적 에너지 관리방안 연구 (A Study on the Cooling Load Generation for Efficient Energy Management)

  • 우남섭;김용기;이태원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1007-1012
    • /
    • 2008
  • Demand for the highly efficient and high performance urban energy supply system having been continuously increased according to the rise of quality of life and continuously increased energy cost all over the world. The district heating and cooling system is very effective way for energy saving, cost reduction, and demand side management of energy. There are several district cooling supply technologies such as chilled water direct transportation, installation of absorption type chiller in the user side, and desiccant cooling. This study investigates the advantage and technical problems of each district cooling technology. Also, it is necessary political and financial support system for the extension of district cooling system.

  • PDF