• 제목/요약/키워드: Water distribution system

검색결과 1,586건 처리시간 0.029초

배수관망해석(配水管網解析)에 있어서 절점유출법(節点流出法)과 관로유출법(管路流出法)의 비교(比較) (Comparison of the Node Method and the Pipeline Method for the Analysis of Water Distribution Systems)

  • 이상목;류종현;현인환
    • 상하수도학회지
    • /
    • 제10권4호
    • /
    • pp.85-93
    • /
    • 1996
  • This study is to make a comparison between the node method and the pipeline method for the analysis of the water distribution systems. For these purposes, the two methods were applied to a pipeline system in series, an artificial distribution network and a real distribution network. The results are as follows. 1. The difference between the results of the two methods was increased with the increase of the hydraulic gradient and the length between two adjacent nodes. 2. When all pipe lengths between two adjacent nodes were larger than 200~300m and have the steep hydraulic gradient, it was found that the results of the two methods showed high differences. 3. The difference between the results of the two methods were negligible in the case of the real distribution system in which only 12% whole pipelines were longer than 30m and the longest pipe length was 850m.

  • PDF

An Optimal Design of Paddy Irrigation Water Distribution System

  • Ahn, Tae-Jin;Park, Jung-Eung
    • Korean Journal of Hydrosciences
    • /
    • 제6권
    • /
    • pp.107-118
    • /
    • 1995
  • The water distribution system problem consists of finding a minimum cost system design subject to hydraulic and operation constraints. The design of new branchin network in a paddy irrigation system is presented here. The program based on the linear programming formulation is aimed at finding the optimal economical combination of two main factors : the capital cost of pipe network and the energy cost. Two loading conditions and booster pumps for design of pipe network are considered to obtain the least cost design.

  • PDF

상수도 관망 데이터의 사용목적에 관한 수집 주기 연구 (Study on the sampling rate for the purpose of use in water distribution network data)

  • 이경환;서정철;차헌주;송교신;최준모
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.233-239
    • /
    • 2013
  • Sampling rate of Hydraulic pressure data, depending on the intended use of the water distribution system is an important factor. If sampling interval of hydraulic data is short, that will be more useful but it demand a lot of expense for maintenance. In this study, based on simulation of water distribution system 2 khz data, statistical techniques of student t distribution, non-exceedance probability using the optimal sampling rate for research.

Application of Management Reliability Index for Water Distribution System Assessment

  • Choi, Taeho;Lee, Sewan;Kim, Dooil;Kim, Mincheol;Koo, Jayong
    • Environmental Engineering Research
    • /
    • 제19권2호
    • /
    • pp.117-122
    • /
    • 2014
  • Indexes of safety, restoration, damage impact, and management reliability were developed to assess reliability of drinking water distribution networks (DWDNs) management. The developed indexes were applied to evaluate the reliability of the pipeline management stage during unexpected mechanical and hydraulic accidents of components. The results were used to support the decision-making process in effective management and maintenance by enhancing the administrator's system understanding and by helping to create appropriate maintenance and management policies. The results of this study indicated that application of a management reliability index to assess DWDNs reliability may help create a more effective plan for establishing DWDNs management and maintenance.

다점주입계(多点注入系) 배수관망(配水管網)에 미치는 상수수요형태(上水需要形態)의 영향(影響) (Effect of Water Demand Patterns on the Water Distribution System with Multi-Reservoirs)

  • 현인환;위욱량;이상준
    • 상하수도학회지
    • /
    • 제11권3호
    • /
    • pp.51-58
    • /
    • 1997
  • Determining sizes and the locations of reservoirs in the water distribution system(WDS) with multi-reservoirs is much difficult than that with single reservoir. The extended period simulation(EPS) models provide more comprehensive analysis of water distribution systems than the steady-state models can do. Therefore, EPS models should be applied to the WDS with multi-reservoirs. This study is to investigate the variations of required reservoir sizes and residual nodal pressures according to reservoir locations. In this study, EPS was applied to analyze an artificial and a real WDS under several water demand patterns. As a result, it was found that water demand patterns make no significant differences in the determining of the reservoir size, if they have similar peaking factors. And the variations of the peaking factor should be carefully checked in the design and the analysis of the WDS with multi-reservoirs, because the peaking factor itself will affect the minimum allowable sizes of reservoirs in those systems.

  • PDF

EPANET을 이용한 상수도 관망의 잔류염소 거동 예측 (Chlorine Residual Prediction in Drinking Water Distribution System Using EPANET)

  • 유희종;김주원;정효준;이홍근
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.8-15
    • /
    • 2003
  • In this study, chlorine dose at water storage tank was predicted to meet the recommended guideline for free chlorine residual in drinking water distribution system, using EPANET which is a computer program that performs extended Period simulation of hydraulic and water quality behavior within pressurized pipe networks. The results may be summarized as follows. The decay of chlorine residual by season varied considerably in the following order; in summer ($25^{\circ}C$) > spring and fall (15$^{\circ}C$) > winter (5$^{\circ}C$). For re-chlorination at water storage tank by season, season-varying chlorine dose was required at its maximum of 1.00 mg/l in summer and minimum of 0.40 mg/l in winter as free chlorine residual. The decay of chlorine residual through out the networks increased with water age spent by a parcel of water in the network except for some points with low water demand. In conclusion, the season-varying chlorine dose as well as the monitoring of water quality parameters at the some points which showed high decay of chlorine residual may be necessary to deliver the safe drinking water.

기존 상수도 노후관망의 개량 및 관리 기법의 개발 (Development of Rehabilitation and Management Techniques for Old Water Distribution Systems)

  • 김중훈;김종우
    • 물과 미래
    • /
    • 제29권3호
    • /
    • pp.197-205
    • /
    • 1996
  • 상수도 관망시설에서 각 관로는 시간이 경과함에 따라 각종 부식이 일어나 통수능이 저하된다. 그러므로 적절한 시기에 갱생이나 교체 등의 처리를 해주어야 한다. 본는 연구에서는 각 수요절점에서 요구수량, 요구압력 등 수리학적 조건을 만족시켜주며 동시에 최소의 비용으로 노구된 관로를 처리해주는 의사결정모형을 개발하였다. 교체비용, 관파열보수비용, 양수비용, 관 파열율, 연이율 등은 각 관로의 교체시기를 경제적으로 결정하는데 이용된다. 그리고 배수시설의 수리학적 만족여부는 관망계산 프로그램 KYPIPE에 의해 점검된다. 시스템이 수리학적 조건을 만족지 못할 경우 교체시기는 조건이 만족될 때까지 앞당겨진다. 본 모형은 기존 송배수시설인 수도권 광역상수도 제1단계에 적용되었다. 모형을 이용해 산출한 최적교체시키는 수리학적으로 모의해본 결과 문제가 없으며를 알 수 있었다.

  • PDF

간이상수도에서 물과 약품의 혼합방법 (Mixing Method of Water and Chemicals in a Small-Scale Water Supply System)

  • 유영현;기현;최종욱;김성초;김정수;김용선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3128-3133
    • /
    • 2007
  • The mixing method of water and chemicals is significant in a small-scale water supply system because drinking water should be supplied with a certain quantity of remaining chemicals maintained. In the present study, the concentration distribution and the mixing index were obtained from four models, which were to find out the optimal mixing method of water and chemicals. The two models brought the good mixing effects out of the four, one for providing chemicals from the center of water supply pipe and the other for setting up the semicircle block at the downstream of the chemicals-providing pipe. As a result, the mixing effect was found out to be increased due to the diffusion and the disturbance of flows. In conclusion, these results are expected to contribute to designing the optimal mixing system.

  • PDF

소독부산물 최소화를 위한 운영조건 연구 (Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System)

  • 신형순;최필권;김종수;최일우;김상훈;김태현;이경희;이수문;장은아;정연훈;김주열
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권4호
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.