• 제목/요약/키워드: Water distribution system

검색결과 1,590건 처리시간 0.034초

기후변화에 따른 하수관거시설의 계획우수량 산정을 위한 일반극치분포 분석 (Analysis of Generalized Extreme Value Distribution to Estimate Storm Sewer Capacity Under Climate Change)

  • 이학표;류재나;유순유;박규홍
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.321-329
    • /
    • 2012
  • In this study, statistical analysis under both stationary and non-stationary climate was conducted for rainfall data measured in Seoul. Generalised Extreme Value (GEV) distribution and Gumbel distribution were used for the analysis. Rainfall changes under the non-stationary climate were estimated by applying time variable (t) to location parameter (${\xi}$). Rainfall depths calculated in non-stationary climate increased by 1.1 to 6.2mm and 1.0 to 4.6mm for the GEV distribution and gumbel distribution respectively from those stationary forms. Changes in annual maximum rainfall were estimated with rate of change in the location parameter (${\xi}1{\cdot}t$), and temporal changes of return period were predicted. This was also available for re-evaluating the current sewer design return period. Design criteria of sewer system was newly suggested considering life expectance of the system as well as temporal changes in the return period.

배.급수관망의 잔류염소 확보를 위한 적정 재염소 주입량 산정 및 효과분석 (Computing the Dosage and Analysing the Effect of Optimal Rechlorination for Adequate Residual Chlorine in Water Distribution System)

  • 김도환;이두진;김경필;배철호;주혜은
    • 대한환경공학회지
    • /
    • 제32권10호
    • /
    • pp.916-927
    • /
    • 2010
  • 일반적으로 정수처리 공정에서 염소에 의한 소독공정은 수인성 질병을 억제하고 상수도관망에서 미생물의 재성장을 억제하는 목적으로 사용되고 있다. 그러나 염소소독은 수중의 유기물과 반응하여 소독부산물(Disinfection By-products; DBPs) 과 같은 발암성 물질을 생성함으로 적절한 염소 주입이 필요하고 최근에는 관말지역에서의 잔류염소 확보를 위해 상수관로 나 배수지 등에서 재염소를 실시하는 경향이 증가하고 있는 추세이다. 따라서 본 연구에서는 정수장에서 최적의 염소주입과 재염소 주입량을 산정하기 위하여 미국 EPA에서 개발한 EPANET 2.0을 사용하여 최적 염소 주입량을 산정하고 그 효과를 모의하였다. 대상지역 상수관로에 대한 수질을 모의하기 위하여 bottle test를 통해 수체감소계수($k_{bulk}$)를 도출하였으며, syster-matic analysis method를 이용하여 관벽감소계수($k_{wall}$)를 도출하였다. 배ㆍ급수계통에서의 수질을 정확히 예측하고자 유량과 체류시간 등을 고려한 수리해석 모델을 기초로 하여 상수도관망에서의 잔류염소 농도를 예측하고 염소주입 농도에 따른 소독부산물(DBPs)인 트리할로메탄(Trihalomethanes; THMs)의 생성변화를 실험을 통해 확인하였다. 수체감소계수($k_{bulk}$)를 도출한 결과 온도가 높을수록 초기에 빠른 감소를 보였으며, $25^{\circ}C$의 경우 25시간이 지난 이후에는 절반이상이 감소하였다. 대상지역에 재염소 주입시설을 도입할 경우 최적 재염소 주입량을 산정하였으며, 관망도상에서 경제적으로 유리한 지점을 선정할 수 있었다.

Variations of Disinfection By-products in a Chlorinated Drinking Water Distribution System

  • Lee, Soo-Hyung;Park, Jeong-Kun;Lee, Hyung-Jun;Kim, He-Kap
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권2호
    • /
    • pp.71-78
    • /
    • 2000
  • The chlorination of municipal drinking water supplies leads to the formation of so-called disinfection by-products(DBPs), many of which have been reported to cause harmful health effects based on animal studies. This study was conducted: 1) to observe seasonal changes in the major DBPs at four sampling sites on a drinking water distribution system located in Chunchon, Kangwon Do; and 2) to examine the effects of major water quality parameters on the formation of DBPs. During the field sampling, the water temperature, pH, and total and free chlorine residuals were all measured. The water samples were then analyzed for total organic carbon(TOC) and eight disinfection by-products in the laboratory. Chloroform, dichloroacetic acid, and trichloroacetic acid were the major constituents of the measured DBPs. The concentrations of the total DBPs were highest in fall, particularly in October, and lowest in summer. The concentrations of the total DBPs increased with increasing TOC concentrations. Multiple regression analyses showed that the concentrations of chloroform, bromodichloromethane, and chloral hydrate were linearly correlated with the pH. Other water parameters were not included in the regression equations. Accordingly, these results suggest that TOC and pH are both important factors in the formation of DBPs.

  • PDF

효율적인 상수도 유수율 관리 시스템 설계 및 구현 (Design and Implementation of an Efficient Water Count Management System)

  • 이석재;황정희;하은실
    • 디지털콘텐츠학회 논문지
    • /
    • 제11권2호
    • /
    • pp.169-175
    • /
    • 2010
  • 일상생활 및 제반 활동을 유지시키는 중요한 사회 기반 시설은 상수도이다. 본 논문에서는 상수도 관리의 기본이 되는 유량의 계측과 분배, 관리를 위한 상수도 유수율 관리 시스템의 설계 및 구현 방법을 제안한다. 본 논문에서 제안하는 상수도 유수율 관리 시스템의 개발은 상수도 시설의 유지관리와 상수도 시스템의 효과적인 운영을 위한 데이터를 체계적으로 관리하여 양질의 수량 공급과 합리적인 용수 수요량의 예측 및 누수 방지를 위한 상수도 기반 시설의 설계 방향을 제시할 것으로 판단된다.

상수관망의 수리학적 지배인자 결정기법 (Determination Algorithm of Hydraulic Parameters in Water Distribution System)

  • 박재홍;김상현;한건연
    • 물과 미래
    • /
    • 제29권6호
    • /
    • pp.217-224
    • /
    • 1996
  • 본 연구에서는 관망 시스템에서의 관경, 관경 및 전체유속, 유량 및 전체조도계수를 주어진 지점의 압력과 유량값을 이용하여 산정하는 기법을 개발하였다. 선택된 관망의 수리학적 인자들은 연속방정식과 에너지방정식을 재구성함으로써 결정될 수 있었다. 계수메트릭스를 해석하기 위하여 부가적인 에너지방정식이 사용되었다. 복잡한 관로 시스템에 대해 본 연구모형들이 적용되었다. 본 모형의 검증을 위해 계산결과를 KYPIPE2 모형에 역대입한 결과는 서로 잘 일치하고 있는 것으로 나타났다.

  • PDF

Real-time measurement of velocity distribution of water flow

  • Kawasue, K.;Ishimatsu, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1032-1036
    • /
    • 1990
  • This paper describes a system which enables a real-time measurement of 2-D water flow field. One distinctive feature of our system is that velocity vectors of water flow are obtained from the movement of tracer particles at video rate. In order to enable a fast measurement a real time video processor and two Digital Signal Processor(TMS32OC25) are employed. The real-time video processor extracts contours of tracer particles in order to reduce the amount of image data to be processed. And two DSP(Digital Signal Processor) analyse the correlation of every tracer paticle in the consecutive two images to obtain the velocity distribution of water flow.

  • PDF

동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향 (Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion)

  • 조관형;김선일;우달식
    • 한국환경보건학회지
    • /
    • 제33권1호
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

네트워크 특징에 따른 수질-수리 제약조건 기반 상수도관망 다목적 최적 설계 기술개발 (Development of multi-objective optimal design approach for water distribution systems based on water quality-hydraulic constraints according to network characteristic)

  • 고문진;최영환
    • 한국수자원학회논문집
    • /
    • 제55권1호
    • /
    • pp.59-70
    • /
    • 2022
  • 상수도관망은 대표적인 사회기반시설로 수원에서 수용가에게 물을 공급하는 과정에서 병원성 미생물을 소독하기 위해 염소를 주입한다. 안전한 물의 공급을 위해 잔류염소 농도 기준(0.1-4.0 mg/L)을 유지하도록 규정하고 있으나, 사용자의 사용 패턴, 수령, 상수도관망의 형식 및 특징은 수리학적(i.e., 절점의 압력, 관로의 유속) 및 수질적(i.e., 잔류염소 농도) 특징에 영향을 미친다. 따라서, 본 연구에서는 Multi-objective Harmony Search (MOHS)를 사용하여 수질-수리 인자를 고려한 상수도관망 최적 설계 기법을 개발하였다. 설계인자로는 설계비용과 시스템 탄력성을 고려하였으며, 절점의 압력과 잔류염소 농도를 제약조건으로 적용하였다. 도출된 최적설계안은 상수도관망의 형식 및 특징에 따라 분석하였다. 이러한 최적설계안은 경제적인 측면과 수질 측면의 안전성을 충족할 수 있으며, 사용자의 사용성을 증가시킬 수 있다.

태백권 배수관망 개량사업의 비용효과분석 최적화 모델 연구 (A Study on Cost Benefit Analysis Optimization Model for Water Distribution Network Rehabilitation Project of Taebaek Region)

  • 김태곤;최태호;김경필;구자용
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.395-406
    • /
    • 2015
  • This research carried out an analysis on input cost and leakage reduction effect by leakage reduction method, focusing on the project for establishing an optimal water pipe network management system in the Taebaek region, which has been executed annually since 2009. Based on the result, optimal cost-benefit analysis models for water distribution network rehabilitation project were developed using DEA(data envelopment analysis) and multiple regression analysis, which have been widely utilized for efficiency analysis in public and other projects. DEA and multiple regression analysis were carried out by applying 4 analytical methods involving different ratios and costs. The result showed that the models involving the analytical methods 2 and 4 were of low significance (which therefore were excluded), and only the models involving the analytical methods 1 and 3 were suitable. From the result it was judged that the leakage management method to be executed with the highest priority for the improvement of revenue water ratio was installation of pressure reduction valve, followed by replacement of water distribution pipe, replacement of water supply pipe, and then leakage detection and repair; and that the execution of leakage management methods in this order would be most economical. In addition, replacement of water meter was also shown to be necessary in case there were a large number of defective water meters.

1차원수리모형-분포형 연계모형을 이용한 수질오염사고 분석 (Pollution accident analysis using a hybrid hydrologic-hydraulic model(K-River & K-DRUM))

  • 이용현;안현욱;안정민;허영택
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.472-472
    • /
    • 2023
  • 본 연구에서는 낙동강 수계에서 발생한 수질오염사고에 대해 K-River와 K-DRUM 결합모형을 이용하여 오염물질의 이동을 분석하였다. 국내에서는 수질오염총량제 도입 이후 수질관리에서 물순환과정을 수용한 배분모델의 필요성과 비점오염원의 중요성이 강조되었다. 따라서 비점오염원의 유출특성을 반영하기 위해 유역의 오염도를 분석할 수 있는 K-DRUM 분포모형을 사용하였다. 그리고 낙동강 수계에서 운영되는 댐 운영규칙을 적용하여 모델의 재현성을 높였다. 또한 하천 내 오염물질의 이동을 분석하기 위해 대류-분산 방정식의 대류 부분만을 1차원 수리모델 K-River에 적용하여 오염물질 추적을 수행하였다. 수질오염 분석 결과 오염물질의 최고농도는 과소평가 되었으나 도착시간과 전체 오염물질 농도의 추이는 잘 재현되었다.

  • PDF