• Title/Summary/Keyword: Water distribution system

Search Result 1,586, Processing Time 0.028 seconds

Comparison of the Node Method and the Pipeline Method for the Analysis of Water Distribution Systems (배수관망해석(配水管網解析)에 있어서 절점유출법(節点流出法)과 관로유출법(管路流出法)의 비교(比較))

  • Lee, Sang Mok;Lyu, Jong Hyun;Hyun, In Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.85-93
    • /
    • 1996
  • This study is to make a comparison between the node method and the pipeline method for the analysis of the water distribution systems. For these purposes, the two methods were applied to a pipeline system in series, an artificial distribution network and a real distribution network. The results are as follows. 1. The difference between the results of the two methods was increased with the increase of the hydraulic gradient and the length between two adjacent nodes. 2. When all pipe lengths between two adjacent nodes were larger than 200~300m and have the steep hydraulic gradient, it was found that the results of the two methods showed high differences. 3. The difference between the results of the two methods were negligible in the case of the real distribution system in which only 12% whole pipelines were longer than 30m and the longest pipe length was 850m.

  • PDF

An Optimal Design of Paddy Irrigation Water Distribution System

  • Ahn, Tae-Jin;Park, Jung-Eung
    • Korean Journal of Hydrosciences
    • /
    • v.6
    • /
    • pp.107-118
    • /
    • 1995
  • The water distribution system problem consists of finding a minimum cost system design subject to hydraulic and operation constraints. The design of new branchin network in a paddy irrigation system is presented here. The program based on the linear programming formulation is aimed at finding the optimal economical combination of two main factors : the capital cost of pipe network and the energy cost. Two loading conditions and booster pumps for design of pipe network are considered to obtain the least cost design.

  • PDF

Study on the sampling rate for the purpose of use in water distribution network data (상수도 관망 데이터의 사용목적에 관한 수집 주기 연구)

  • Lee, Kyounghwan;Suh, JungChul;Cha, Hunjoo;Song, Kyosin;Choi, Junemo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.233-239
    • /
    • 2013
  • Sampling rate of Hydraulic pressure data, depending on the intended use of the water distribution system is an important factor. If sampling interval of hydraulic data is short, that will be more useful but it demand a lot of expense for maintenance. In this study, based on simulation of water distribution system 2 khz data, statistical techniques of student t distribution, non-exceedance probability using the optimal sampling rate for research.

Application of Management Reliability Index for Water Distribution System Assessment

  • Choi, Taeho;Lee, Sewan;Kim, Dooil;Kim, Mincheol;Koo, Jayong
    • Environmental Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.117-122
    • /
    • 2014
  • Indexes of safety, restoration, damage impact, and management reliability were developed to assess reliability of drinking water distribution networks (DWDNs) management. The developed indexes were applied to evaluate the reliability of the pipeline management stage during unexpected mechanical and hydraulic accidents of components. The results were used to support the decision-making process in effective management and maintenance by enhancing the administrator's system understanding and by helping to create appropriate maintenance and management policies. The results of this study indicated that application of a management reliability index to assess DWDNs reliability may help create a more effective plan for establishing DWDNs management and maintenance.

Effect of Water Demand Patterns on the Water Distribution System with Multi-Reservoirs (다점주입계(多点注入系) 배수관망(配水管網)에 미치는 상수수요형태(上水需要形態)의 영향(影響))

  • Hyun, In Hwan;Wi, Wuk Ryang;Lee, Sang Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.51-58
    • /
    • 1997
  • Determining sizes and the locations of reservoirs in the water distribution system(WDS) with multi-reservoirs is much difficult than that with single reservoir. The extended period simulation(EPS) models provide more comprehensive analysis of water distribution systems than the steady-state models can do. Therefore, EPS models should be applied to the WDS with multi-reservoirs. This study is to investigate the variations of required reservoir sizes and residual nodal pressures according to reservoir locations. In this study, EPS was applied to analyze an artificial and a real WDS under several water demand patterns. As a result, it was found that water demand patterns make no significant differences in the determining of the reservoir size, if they have similar peaking factors. And the variations of the peaking factor should be carefully checked in the design and the analysis of the WDS with multi-reservoirs, because the peaking factor itself will affect the minimum allowable sizes of reservoirs in those systems.

  • PDF

Chlorine Residual Prediction in Drinking Water Distribution System Using EPANET (EPANET을 이용한 상수도 관망의 잔류염소 거동 예측)

  • 유희종;김주원;정효준;이홍근
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.8-15
    • /
    • 2003
  • In this study, chlorine dose at water storage tank was predicted to meet the recommended guideline for free chlorine residual in drinking water distribution system, using EPANET which is a computer program that performs extended Period simulation of hydraulic and water quality behavior within pressurized pipe networks. The results may be summarized as follows. The decay of chlorine residual by season varied considerably in the following order; in summer ($25^{\circ}C$) > spring and fall (15$^{\circ}C$) > winter (5$^{\circ}C$). For re-chlorination at water storage tank by season, season-varying chlorine dose was required at its maximum of 1.00 mg/l in summer and minimum of 0.40 mg/l in winter as free chlorine residual. The decay of chlorine residual through out the networks increased with water age spent by a parcel of water in the network except for some points with low water demand. In conclusion, the season-varying chlorine dose as well as the monitoring of water quality parameters at the some points which showed high decay of chlorine residual may be necessary to deliver the safe drinking water.

Development of Rehabilitation and Management Techniques for Old Water Distribution Systems (기존 상수도 노후관망의 개량 및 관리 기법의 개발)

  • 김중훈;김종우
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.197-205
    • /
    • 1996
  • Flow carrying capacity of water distribution systems is getting reduced by deterioration of pipes in the systems. The objective of this study is to develop a managerial decision-making model for the rehabilitation of water distribution systems with a minimum cost. The decisions made by the model also satisfy the requirements for the discharge and pressure at demanding nodes in the system. The replacement cost, pipe break repair cost, and pumping cost are considered in the economic evaluation of the decision along with the break ratio and interest ratio to determine the optimal replacement time for each pipe. Then, the hydraulic integrity of the water distribution system is checked for the decision by a pipe network simulator, KYPIPE, if the discharge and pressure requirements, the decision made for the optimal replacement time is revised until the requirements are satisfied. The model is applied to an existing water distribution system, the Metropolita Water Supply Project (1st Phase). The result shows that the decisions for the replacement time determined by the economix analysis are accepted as optimal and the hydraulic integrity of the system is in good condition.

  • PDF

Mixing Method of Water and Chemicals in a Small-Scale Water Supply System (간이상수도에서 물과 약품의 혼합방법)

  • Yoo, Young-Hyun;Ki, Hyun;Choi, Jong-Wook;Kim, Sung-Cho;Kim, Jeong-Soo;Kim, Yong-Seon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3128-3133
    • /
    • 2007
  • The mixing method of water and chemicals is significant in a small-scale water supply system because drinking water should be supplied with a certain quantity of remaining chemicals maintained. In the present study, the concentration distribution and the mixing index were obtained from four models, which were to find out the optimal mixing method of water and chemicals. The two models brought the good mixing effects out of the four, one for providing chemicals from the center of water supply pipe and the other for setting up the semicircle block at the downstream of the chemicals-providing pipe. As a result, the mixing effect was found out to be increased due to the diffusion and the disturbance of flows. In conclusion, these results are expected to contribute to designing the optimal mixing system.

  • PDF

Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System (소독부산물 최소화를 위한 운영조건 연구)

  • Shin, Hyung-Soon;Choi, Phil-Kweon;Kim, Jong-Su;Choi, Ill-Woo;Kim, Sang-Hoon;Kim, Tae-Hyun;Lee, Kyung-Hee;Lee, Soo-Moon;Jang, Eun-Ah;Jung, Yeon-Hoon;Kim, Jung-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.4
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.