• Title/Summary/Keyword: Water curtain

Search Result 132, Processing Time 0.025 seconds

Performance Evaluation of Curtain-Wall Applying Light-weight Inorganic Foam Panel (경량 무기 발포패널을 적용한 커튼월의 성능평가)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.211-212
    • /
    • 2012
  • To prevent energy waste in buildings used heat insulator. Heat insulator materials can be classified inorganic and organic. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. However, there is little study to explain fire resistance performance of the curtain walls. This study focused on evaluation of the physical properties of light-weight inorganic foam panel for using industrial by-products materials and performance evaluation by mock up test.

  • PDF

Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse (2중 단동비닐하우스의 태양열 축열이용 효과)

  • Lee, Sung-Hyoun;Ryou, Young-Sun;Moon, Jong-Pil;Yun, Nam-Kyu;Kwon, Jin-Kyung;Lee, Su-Jang;Kim, Kyeong-Won
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

A Study on the Practical Use of Alternative Energy for Agriculture in Korea (우리나라 농업의 대체에너지 활동 실태에 관한 연구)

  • 홍지형
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.81-90
    • /
    • 1993
  • Groundwater and animal wastes are typical example which are underutilized resources than their value in agriculture. This paper was to investigate the actual patterns of utilization of water curtain for greenhouses and methane gas utilization from swine wastes in a view point of promoting more efficient use of alternative energy. The results from measurements can be summarized as follows : 1.It was estimated that the maximum heating load per l0a was around 23,2804/hr and the heating load at January showed 3.93X 1064 respectively for strawberry greenhouses with insulation by the water curtain. 2.The average heating cost of the greenhouse with water curtain system amounted to about 75,000 Won per l0a. This result suggested that the greater cultivated area provides less heating cost. 3.The operating volume was about 73 percent of the optimum size of the digester. The net available methane gas rates of the produced gas remained close to 62 percent, But the conventional and small size of the digester was maintained at a lower level of around 20 to 29 percent. 4.It appeared that major problems of biogas production system were required to maintain the temperature of the fermentation above ambient temperature and the optimum volume of digester.

  • PDF

O/H Stable Isotopic Composition and Groundwater-surface Water Connectivity: A Case Study for Wangjeon-ri Water Curtain Cultivation Area, Nonsan, Korea (산소/수소안정동위원소를이용한지하수-지표수연계성연구: 논산시왕전리수막 재배지역 사례)

  • Moon, Sang-Ho
    • Economic and Environmental Geology
    • /
    • v.51 no.6
    • /
    • pp.567-577
    • /
    • 2018
  • One of problems related with water curtain cultivation (WCC) in Korea includes severe declination of groundwater levels during the peak season, and it is likely that the problem can be resolved efficiently when the connection characteristics between groundwater and stream are well understood. This study examined temperature, and oxygen/hydrogen stable isotopic compositions of the flowing groundwater to understand the connection between stream and ground water, and the influence of stream water on the nearby aquifer. This study was performed in Wangjeon-ri (Kwangseok-myon, Nonsan City), the well-known strawberry town using WCC technique. The sampling was done during February 2010 through June 2011 for both groundwaters and nearby streams. Temperature distribution pattern indicates that stream widely affected groundwater in the right part of WCC ara. In the left part, the influence of stream seems to occur narrowly near the stream. The similar phenomenon is reflected in the oxygen and hydrogen isotopic data.

Analysis of Correclations between Flow Rate, Pressure and Average Size of Droplet with Hydraulic Diameter of Water Curtain Nozzle (수막설비용 노즐의 수력직경 변화에 따른 방사유량, 방사압 그리고 액적의 평균 크기 상관관계 분석)

  • Park, Jung Wook;Shin, Yeon Je;You, Woo Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.317-323
    • /
    • 2020
  • In this study, the correlations between flow rate, exhaust pressure, and droplet mean diameter with the shape factor of a water curtain nozzle were investigated. To analyze the flow coefficient and the distribution constant on the effects of the hydraulic diameter, five nozzles (D5W3, D5W6, D5W8, D4W6, and D7W6) were mocked up with a consideration of the internal diameter and width. The results showed that the flow coefficient increased in proportion to the constant 0.79 and 62.8 of the hydraulic diameters according to the diameter. As the nozzle width increased, the average droplet size decreased to the -0.235 exponential of the pressure. The average volume was reduced, in which the size distribution of the volume indeterminate decreased with increasing pressure for the same nozzle of the water-curtain. The distribution constants of droplet increased in proportion to the 0.258 exponential of the hydraulic diameter and 244.21. These results are expected to be useful to the design of pressure, flow meter, and average droplet size from a water curtain nozzle to predict the flow characteristics.

A Study of Numerical Analysis on Hydrogeological Influence by Groundwater Development around Underground Oil Storage Cavern (지하 석유비축기지 주변의 지하수 개발에 의한 수리지질학적 영향의 수치해석 연구)

  • 정현영;송무영;이경주
    • The Journal of Engineering Geology
    • /
    • v.11 no.1
    • /
    • pp.37-50
    • /
    • 2001
  • Through the modeting study on the groundwater now system around the underground stockpile site of crude oil near Seoul, we carried out the research on the influence of the groundwater yield near the site, the effect of the water curtain construction in order to reduce the influence of water yield, and the realized case study by measuring the water level change after the construction of the water curtain. For the simu1ation of the water yield and the water curtain, the nwnerical analysis code, MODFLOW has been utilized. Groundwater levels of the observation wells which were established to observe the hydraulic head around underground oil storage cavern of the study area have been changed in the range of from EL.+30 to +60 meter, while the simulation study revealed that groundwater levels changed in the range of from EL.+20 to +5Om. The hydrogeological condition of the underground oil storage cavern becomes stable by injection water to maintain the groundwater level around the cavern. The result shows the proper input of the hydrogeological factors helps the management to be effective for the oil stockpile site.

  • PDF

A Study on the Removal Efficiency of the Soil Vapor Extraction by Numerical Simulation (수치모형에 의한 토양증기추출법의 제거효율에 관한 연구 - 차단벽, 추출유량, 펌프가동방법의 영향 -)

  • Lee, Chang-Su
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.2
    • /
    • pp.121-129
    • /
    • 1999
  • When the soil vapor extraction as a remediation method of contaminated soil and groundwater has been used, the effects of curtain wall, mode of pump operation and magnitude of extraction flowrate were examined by numerical simulation. Consequently, it was found that the removal rate was enhanced in case that the curtain wall was established around the extraction well with the extraction pumps operated alternatively. It was because that the removal of high density gas around the extraction well was possible. It was found that the removal efficiency of TCE gas did not depend on the extraction flowrate. However, the removal rate of TCE gas at varying extraction flowrate was not enhanced flowrate increase.

  • PDF

Reinforcement effect of surface stabilizer using surface curtain walls on aging reservoirs

  • Song, Sang-Huwon;Cho, Dae-Sung;Seo, Se-Gwan
    • Geomechanics and Engineering
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • In Korea, accidents related to the collapse of deteriorated aging reservoirs occur every year. The grouting method is generally applied to reinforce an aging reservoir. However, when using this method, different reinforcing effects appear depending on the ground conditions. Thus, new construction methods and materials capable of providing consistent reinforcing effects are required. In this study, the direct shear test (DST), model test, and simulation analysis were performed to evaluate the impact of surface stabilizers, generally used to reinforce roads, rivers, and slopes of roads, applied using surface curtain walls on aging reservoirs. The DST results indicate that when the surface stabilizer was mixed with in-situ soil, the increase in cohesion was the highest at a mixing ratio of 9%. No changes in the friction angle were evident; therefore, 9% was determined to be the optimal mixing ratio. In addition, the model test and simulation analysis showed that when 9% of the surface stabilizer was mixed and applied to the aging reservoir, the seepage quantity of water and the saturated area were reduced by approximately 42% and 73%, respectively. Moreover, the comprehensive analysis of results showed that the grouting method could be completely replaced by surface stabilizers applied through surface curtain walls because the technique could secure stability by decreasing the seepage in the aging reservoir.