• Title/Summary/Keyword: Water curtain

Search Result 131, Processing Time 0.023 seconds

Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System (유리커튼월 수막시스템 분무헤드의 화재 실험 연구)

  • Kim, Sung-Won;Nam, Jiwoo;Cho, Seongwook;Ryou, Hong-Sun;Nam, Jun-Seok;Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, a curtain wall system was applied to skyscrapers to prevent fire spreading along the vertical direction due to stack effect and outside air flow when a fire breaks out in skyscraper. Conventional sprinklers cannot prevent the spread of fire to the upstairs areas, which increases the loss of life and property. In this study, a water curtain nozzle that creates wider water coverage on the surface of glass and can prevent the spread of fire to the upstairs areas was developed. The spray pattern of the water curtain nozzle was compared with that of a sprinkler to determine performance of the water curtain nozzle. A fire experiment was constructed on the second floor to verify performance of the water curtain nozzle in preventing the spread of fire to the upstairs areas. The fire and watering experiment proved that the water curtain nozzle prevented more effectively the spread of fire than the conventional sprinkler. The position of first crack and critical temperature of fracture were also analyzed using numerical analysis.

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.

A Numerical Study on the Mitigation Effect of Water Curtain for SiCl4 Toxic Gas Release (SiCl4 누출 시 수막설비의 방재효과에 대한 수치 해석 연구)

  • Tae In Ryu;Eunmi Lee;Seungha Kim;Seong-mi Kang;Chang-hyun Shin;Seungbum Jo
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.43-50
    • /
    • 2023
  • Silicone tetrachloride (SiCl4) leak accidents cause enormous human and environmental damage because it is highly toxic. Some handling facilities use water curtains to reduce the impact range of SiCl4. Although the water curtain is known as one of the most efficient technologies for post-release mitigation, its effect on reducing SiCl4 concentration needs to be investigated scientifically and quantitatively. In this study, three-dimensional computational fluid dynamics (CFD) was used to investigate the physical and chemical effects of water curtains as a release-mitigation system for SiCl4. SiCl4 is released and dispersed five seconds prior to the operation of the water curtain. Once the water curtain works, the SiCl4 reacts chemically with the water and its concentration decreases rapidly; it reaches an emergency response planning guidelines level 2 (ERPG-2) of 5 parts per million (ppm) at about 570 m. We observed, however, that the physical effect of water curtains on reducing SiCl4 concentration is insignificant when the chemical effect is eliminated. These results are crucial since they can be a scientific and quantitative basis for the 'technical guidelines for estimating the accident affected range'. In order to protect the public from chemical accidents, more toxic gas mitigation technologies need to be developed.

Establishment of Numerical Model for Groundwater Flow (Water Curtain) Analysis around Underground Caverns (지하공동 주변의 지하수 흐름(수막)해석을 위한 수치모형의 확립)

  • Jeong, Il-Mun;Jo, Won-Cheol;Bae, Deok-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.1
    • /
    • pp.63-73
    • /
    • 1997
  • Finite element model is established for the simulation of groundwater flow due to water curtain around underground oil storage Choleski decomposition method. The symmetric global conductance matrix is solved by vector storage Choleski decomposition method. The model is verified through comparison with the results of electric analogy. For the application of this model to real site, the finite element meshes are constructed according to representative vertical cross and longitudinal sections. In cross-sectional analysis, potential and flow distributions are compared based on the cavern pressure and horizontal water curtain. For longitudinal section, effects between nearly located caverns with or without vertical water curtain are analyzed. These results prove that the established model can be used as a tool for flow analysis around underground caverns.

  • PDF

A Study on Performance of Water Curtain Nozzles for Protection of Wooden Cultural Properties from Forest Fire (산불로부터 목조문화재 보호를 위한 수막노즐의 성능에 관한 연구)

  • Kim, Kyoung-Jin;Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.8-13
    • /
    • 2012
  • This study suggests the water curtain nozzles as the way to protect important wooden cultural properties from an adjacent building fire or a forest fire. They are designed to block off the pyrolysis of timbers which occurs at $200{\sim}250^{\circ}C$ by forming a water curtain with the flow of water that spouts over a certain pressure from the bottom. The existing water curtain nozzles installed at the following sites were examined: NakSan-sa (Temple) in Gangwon-do (Province) and in Muwisa (Temple) in Jeollanam-do (South Province). As a way to improve and complement the system, this study designed nozzles with covers in order not to disrupt the landscape. Connected pipes are elevated and jet water when they are in use. Possible ways to install the connected elevating pipes to jet water effectively were investigated.

A Study on the Change of Free Surface Vortex according to Intake Conditions in the Pump Sump (펌프 섬프장 흡입 조건에 따른 자유표면 보텍스 변동에 관한 연구)

  • Park, Young-Kyu;Li, Kui-Ming;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.74-79
    • /
    • 2011
  • In this study the change of free surface vortex is represented at different times according to height of water and with or without curtain wall installation. The air volume fraction is investigated at each condition of water level and the influence about creation of vortex is analyzed. The height of sump intake is taken as 100mm and the water level is divided into 5 steps. The sump model is the TSJ model and the curtain wall is applied by HI standard of America. The results shows that the free surface vortex can be identified on the isotropic surface at air volume fraction 1%~5% and the vortices make an air column from the free surface to the sump intake and are created and destroyed repeatedly. In the higher water level, less air is absorbed into the intake pipe. After curtain wall installation, the suction rate of the air volume fraction is decreased by 6.7%. The result of the vortex motion according to time, works on a cycle.

Analysis on the Relations of Droplet Size Distribution and Optical Depth in Water Curtain (워터커튼에서 액적의 크기 분포와 광학 두께의 상관관계 분석)

  • You, Woo Jun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.62-67
    • /
    • 2016
  • In this study, the optical depth is analyzed with the effects of droplet size distribution of the water curtain nozzle to attenuate the radiative heat transfer. The HELOS/VARIO equipment is used for the measurement of the droplet size distributions. The spray characteristics are quantified by the investigation of Deirmenjian's modified gamma distribution function. The distribution constant of the nozzle can be obtained as ${\alpha}=1$ and ${\gamma}=5.2$. The generalized equation of the optical depth related with the droplet size distribution is introduced. These results will be applicable to the analysis of the design condition of the water curtain nozzle.

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

Analysis the Effects of Physical Blocking Weirs on the Water Quality in Daechung Reservoir (물리적 차단시설이 대청호 수질에 미치는 효과 분석)

  • Lee, Heungsoo;Chung, Sewoong;Park, Hyungseok;Jeong, Donghwan
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.1
    • /
    • pp.25-39
    • /
    • 2012
  • This study was aimed to assess the effects of additional installation of two different types of weirs, one is a curtain-type weir and another is a submerged-type weir, on the control of algal growth in Daechung Reservoir. A two-dimensional(2D) coupled hydrodynamic and eutrophication model that can accommodate vertical movement of the curtain weir following the water surface variations was verified using field data obtained in two distinctive hydrological years; dry(2008) and wet(2010). The model adequately simulated the temporal and spatial variations of water temperature, nutrients and algal(Chl-a) concentrations during the periods. The effectiveness of curtain weir on the control of algal bloom was evaluated by applying the model to 2001(dry year) and 2010 assuming 6 different scenarios according to installation locations. The curtain weirs that already installed at 3, 5, 7 sites(scenario C-2) showed significant effect on the control of algal growth in the reservoir; the reduction rates of algal concentration were placed in the range of 7.5~31.5% and 9.1~44.9% for 2001 and 2010, respectively. However the simulation results revealed that additional installation of curtain weirs(scenario C-3~C-6) in the bay area (choosori) have marginal effect. The effectiveness of submerged weir was evaluated against 2010 assuming 7 different scenarios according to installation locations, but all scenarios(S-1~S-7) showed neglectable or negative effect on the control of algal growth.

Characterization of a groundwater system by subsurface hydrogeological investigation data (지하공동굴착 시 수리지질조사 자료를 이용한 저장공동 심도의 지하수체계 특성 연구)

  • 조성일;김천수;김경수;송무영;전한석
    • The Journal of Engineering Geology
    • /
    • v.14 no.1
    • /
    • pp.93-104
    • /
    • 2004
  • This paper intended to assess the hydro-structure characteristics of volcanic rocks based on the hydrogeological data obtained from the underground storage cavern during construction. The variation of groundwater levels was periodically measured from the 28 surface monitoring holes(NX size) and the hydraulic pressures and injection rates were daily monitored from the water curtain holes(95 horizontal holes and 63 vertical holes). The hydraulic interference tests were performed in whole water curtain holes. The distribution patterns of hydraulic pressure are closely related to the dip angles of fracture intersected to the water curtain holes. Three domains can be grouped by the distribution of hydraulic pressures in the horizontal water curtain holes. The initial hydraulic pressures measured immediately after drilling of water crutain holes are high in ascending order of the cavern C-2, C-1, and C-3. The priliminary hydrochemical data also indicate that the portions of the deep groundwater composition is relatively great in the cavern C-3 area. Some of the horizontal water curtain holes in the cavern C-3 show a steady higher groundwater pressure with the composition of shallow groundwater indicating the outer boundary as constant hydraulic boundary. The water curtain holes in the cavern C-2 is characterized as low initial hydraulic pressure and less injection rates, suggesting poor hydraulic connectivity to a shallow groundwater system. The results of the study can help to understand a hydraulic compartment concept in a fracture hydro-geology and be utilized during the surface investigation for a groundwater system.