• 제목/요약/키워드: Water consumption

검색결과 1,949건 처리시간 0.022초

Effect on Testosterone Production in Sprague-Dawley Rats of Gastrodia and Bee Pollen

  • Hong, In-Pyo;Woo, Soon-Ok;Jang, Jae-Seon
    • 한국환경보건학회지
    • /
    • 제39권1호
    • /
    • pp.43-47
    • /
    • 2013
  • Objectives: We investigated the effects of Korean gastrodia and bee pollen on testosterone production in Sprague-Dawley rats. Methods: This study measured the body weight, consumption of food and water, and serum testosterone concentration in SD rats fed for four weeks with gastrodia and bee pollen. Results: The average body weights after four weeks were $375{\pm}2g$ for the control group, $358{\pm}3g$ for gastrodia consumption, and $354{\pm}2g$ and $367{\pm}8g$ for acorn pollen and Siberian gooseberry pollen, respectively. The average food consumption in SD rats over the four weeks in the control was 23.6 g for gastrodia consumption, 24.3 g and 24.9 g for acorn pollen and Siberian gooseberry pollen, respectively. The average water consumption over the four weeks was 38.33 ml in the control group, 35.0 ml for gastrodia treatment, and 33.3 ml and 33.3 ml for acorn pollen and Siberian gooseberry pollen treatment, respectively. The testosterone secretion levels in the serum of male rats were increased by gastrodia, acorn pollen, and Siberian gooseberry pollen (2.68, 3.00, and 3.28 pg/ml, respectively) compared to the control group (2.23 pg/ml). Conclusions: These results suggest that gastrodia or bee pollen may be developed as a complementary medicine to improve sexual hormone production.

인버터시스템 적용 지역난방 시스템의 2차측 공급수 온도 제어방안에 따른 에너지사용량 실증 비교 (Actual Energy Consumption Analysis of Temperature Control Strategies for Secondary Side Hot Water District Heating System with an Inverter)

  • 조성환;홍성기
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.179-186
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side District Heating System (DHS) with different hot water supply temperature control methods is compared. The two methods are Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side system, the results show that the Outdoor Temperature Predictive Control method saves more energy. In general, the Outdoor Temperature Predictive Control method lowers the supply temperature of hot water, and it reduces standby losses and increases the overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, the Outdoor Temperature predictive Control method saves about 6.6% of energy when compared to the Outdoor Temperature Reset Control method. Also, it is found that at partial load condition, such as during daytime, the fluctuation of hot water supply temperature with Outdoor Temperature Reset Control is more severe than that with Outdoor Temperature Predictive Control. Thus, it proves that Outdoor Temperature Predictive Control is more stable even at partial load conditions.

VALUE OF BARLEY GRAIN AND COTTONSEED CAKE AS SUPPLEMENTS TO FOURWING SALTBUSH, AND THE LIVE WEIGHT GAINS AND WATER CONSUMPTION OF SHEEP FED THE DIETS

  • Rehman, Atiq-ur;Thompson, E.F.;Rafique, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제9권6호
    • /
    • pp.647-650
    • /
    • 1996
  • Fifteen sheep were used in a trial which compared the feeding value of whole barley gain and cottonseed cake as supplements to a basal diet of leaves of fourwing saltbush (Atriplex canescens). Diet SB contained 700 g (air-dry matter) of saltbush alone, diet SB + BG contained 700 g SB with 400 g whole barley grain and diet SB + CS contained 700 g SB with 400 g cottonseed cake. The digestibility of the dry matter of diets SB (69%) and SB + CS (70%) were lower (p < 0.001) than of diet SB + BG (76%). Sheep offered SB alone daily lost 80g whereas those fed the other diets gained 11 g (SB + CS) or 17 g (SB + BG) per day. Daily water consumption of the sheep offered the three diets was similar (p > 0.05), but their water consumption was higher (p < 0.001) than that of sheep offered daily 700 g wheat straw and 200 g barley grain. The results indicate that, at the levels of feeding used, barley grain and cottonseed cake had similar value as supplements to fourwing saltbush harvested in summer. The addition of the supplement allowed the sheep to gain some live weight. However, the presence of saltbush leaves in the diet resulted in higher water intakes by the sheep.

OXYGEN CONCENTRATION IN THE CATHODE CHANNEL OF PEM FUEL CELL USING GAS CHROMATOGRAPH

  • Ha, T.H.;Kim, H.S.;Min, K.D.
    • International Journal of Automotive Technology
    • /
    • 제8권1호
    • /
    • pp.119-126
    • /
    • 2007
  • Because of the low temperature operation, proton exchange membrane (PEM) fuel cell has a water phase transition. Therefore, water management is an important operation issue in a PEM fuel cell because the liquid water in the fuel cell causes electrode flooding that can lower the cell performance under high current density conditions. In this study, in order to understand the reactant distributions in the cathode channels of the PEM fuel cell, an experimental technique that can measure the species concentrations of reactant gases by using gas chromatograph (GC) is applied for an operating PEM fuel cell. The oxygen distribution along the cathode flow channels of PEM fuel cell is mainly investigated with various operating conditions. Also, the relations between cathode flooding and oxygen concentrations and oxygen consumption pattern along the cathode channel configurations of the unit cell adopted for this study are discussed using GC measurement and visualization experiment of cathode flooding. It is found that the amount of oxygen consumption is very sensitive to various operating conditions of the fuel cell and was much affected by the flooding occurrence in cathode channels.

서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석 (A Case Study for Energy Consumption Characteristics of High School Facilities in Seoul)

  • 김성범;오병칠;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.61-69
    • /
    • 2016
  • In this study, we analyzed five-year(2011~2015) data for D high school in Seoul area to analyze energy consumption characteristics in high school. The results are summarized as follows. (1) In the result of comparison analysis about 2015 energy consumption by usage, based on primary energy, 18% of energy was consumed in cafeteria, and 82% was consumed in main building. In the case of main building, base and constant load excepting hot water supply in restroom took 40%, heating including freeze protection took 20%, hot water supply in restroom took 14%, and cooling took 8% in order. (2) In the 2015 total energy consumption in D high school based on primary energy, heating energy takes 28%. The range and limit of energy savings coming from the reinforcement of insulation and window performance could be estimated. (3) To introduce new & renewable energy system in high school, electricity-based system is suitable than heat-based system because usage of electric energy is larger than that of heat energy in high school. (4) Five-year energy consumption unit according to heating degree-day showed a linearly increasing trend, and the coefficient of determination(R2) was 0.9763, which means high correlation.

가변 콘덴서를 이용한 디지털 수도미터의 설계 및 제작 (Design and Fabrication of Digital Water Meter Using a Variable Capacitor)

  • 박근형
    • 한국전기전자재료학회논문지
    • /
    • 제29권3호
    • /
    • pp.141-146
    • /
    • 2016
  • The AMR(automatic meter reading) system has been increasingly and widely used for its efficient and intelligent management, which is a technology that automatically collects consumption data from a water meter or energy metering device. The digital meter instead of the mechanical meter should be used in the system. Up to now, various types of sensor to measure the water flow rate have been used in the digital water meter, for example, reed switch, photo IR approximate sensor, ultrasonic sensor, electromagnetic sensor, etc. In this paper, a new sensing technology, where a variable capacitor and digital circuit were used for sensing the water flow rate, was proposed. The circuit was designed and verified by Pspice simulation. And a PCB board for the circuit was fabricated. After then, a prototype of digital water meter using a variable capacitor to measure the water flow rate was fabricated. The function tests of the fabricated digital water meter were performed, and it was found that the meter worked properly. Since the new technology has much better properties in terms of cost and power consumption compared to conventional technologies, it should be one of the major digital water meter technologies in the future.

에너지 소모를 고려한 역삼투 해수담수화 플랜트 주요 성능인자 영향 분석 (Comprehensive Analysis of Major Factors Associated with the Performance of Reverse Osmosis Desalination Plant for Energy-saving)

  • 김지혜;이경혁;임재림
    • 멤브레인
    • /
    • 제29권6호
    • /
    • pp.314-322
    • /
    • 2019
  • 기후변화로 인해 가속화되고 있는 충남 지역 가뭄현상에 대응하고 대산 임해산업단지의 증가하는 용수 수요를 만족하기 위해서, K-water에서는 100,000 ㎥/일 규모 역삼투 해수담수플랜트 건설 사업을 추진하고 있다. 이에 본 연구에서는 해수담수플랜트 운영비용의 70% 이상을 담당하는 역삼투 공정 성능에 영향을 미치는 주요 인자에 대한 성능 분석을 수행하였다. 대산 지역 해수 염분농도 및 수온 변화 조건에서 RO 공정의 전력소모는 2.39 ± 0.13 kWh/㎥로 나타났으며, 막여과유속과 회수율이 낮을수록 전력소모가 절감되어 연간 운영비용이 감소하였다. 주요 막 제조사별 고유량 막의 성능 비교 결과, 전량 2단 여과공정(full two pass) 기준 생산수 TDS는 평균 3.84 mg/L로 양호하였고, 전력소모는 2.22 ± 0.13 kWh/㎥ 수준으로 확인되었다. 역삼투 공정 구성을 전량 2단 여과방식에서 partial 또는 split partial 방식으로 변경함에 따라 전력소모는 최대 0.29 kWh/㎥, 막모듈 설치비용은 최대 15.6% 절감 가능할 것으로 기대된다.

고도정수처리에서 사여과와 정밀여과의 유기물처리특성에 관한 연구 (Treatment Characteristics of Sand Filtration and Microfiltration (MF) in Advanced Water Treatment)

  • 김형석;이병호
    • 상하수도학회지
    • /
    • 제24권6호
    • /
    • pp.723-734
    • /
    • 2010
  • With a belief of high water quality production and less chemical usage, membrane technology including Microfiltration (MF), Ultrafiltration (UF), and Nanofiltration(NF) is being employed more and more in drinking water treatment process. However, due to higher energy consumption of UF and NF, MF is normally used for drinking water treatment especially in a plant of large scale. In this investigation, performance ofsand filtration and membrane filtration was compared regarding removal of various water quality parameters, such as TOC, DOC, KMnO4 consumption, THMFP, and HAAFP. Two lines of pilot plant have been operated, one of which line is a traditional advanced water treatment process which includes sedimentation, sand filtration, ozonation, and activated carbon, and the other line is an alternative treatment process which includes sedimentation with inclined plate, MF membrane, ozonation, and activated carbon. For the first about 4months of period, MF filtration showed similar or little bit higher performance than sand filtration. However, after about 4month later, sand filtration showed much higher performance in removing all parameters monitored in the investigation. It was found that sand filtration is a better option than MF filtration as far as microbial community is fully activated in sand filter bed.

서울시 물환경관리체계 개선을 위한 물발자국 도입 및 활용방안에 관한 연구 - 서울시 자치구 물환경관리 정책 및 제도, 관리체계 분석을 중심으로 - (Analysis and Application of Water Footprint to Improve Water Resource Management System - With a Focus on Seoul City -)

  • 전동준;김진오
    • 환경영향평가
    • /
    • 제25권3호
    • /
    • pp.222-232
    • /
    • 2016
  • 물발자국은 인간의 활동을 통해 소비되는 직접수와 간접수의 총사용량을 산정함으로써 지속가능한 물이용을 유도하기 위한 효과적 수단으로 활용되고 있다. 본 연구는 서울시의 물이용 관리와 관련한 계획들의 문제점 분석을 통해 물발자국의 도입가능성을 분석하고 장단기적인 측면에서 도입 및 활용방안을 제시하고자 하였다. 또한 서울시 25개 자치구를 대상으로 시뮬레이션을 통해 청색 및 회색 물발자국을 산정하고, 지역별 물발자국의 차이점 분석과 이를 바탕으로 물발자국을 줄이기 위한 대안들을 모색하였다. 물발자국 측면에서의 서울시 물환경시스템에 대한 분석은 크게 청색물발자국과 회색물발자국으로 나누어 수행하였다. 개인이나 공동체가 제품이나 서비스를 생산 소비하기 위해 필요한 지표수와 지하수의 양을 의미하는 청색물발자국을 분석하기 위해서 서울시의 각 행정구역별 지하수의 사용량과 생활용수의 사용량을 합산하여 추정하였다. 각 행정구역별 청색물발자국을 인구수와 세대수 비율로 확인해 본 결과 중구, 종로구 강남구, 용산구, 서초구 등의 순으로 높게 나타났다. 회색물발자국은 각 행정구역별 BOD기준의 오 폐수발생부하량을 배출기준 수질(BOD기준 3.5ppm)로 정화하여 배출할 때 사용되는 물의 양을 추론하여 산출하였다. 각 행정구역별 회색물발자국을 인구수와 세대수 비율로 확인해 본 결과 중구, 종로구 강남구, 용산구, 서초구, 영등포구 등의 순으로 높게 나타났다. 본 연구 결과는 물관리 있어 공급중심의 양적 관리 정책의 한계를 극복하기 위한 일환으로 물발자국의 개념 및 방법의 도입을 제안하였으며 이는 환경적 경제적 사회적으로 보다 탄력적이고 지속가능한 물관리 정책을 모색하는데 중요한 기초자료가 될 것으로 기대된다.

도시 근로자가계의 주생활비 소비지출구조분석 -1982년부터 1992년까지- (An Analysis of housing Consumption Expenditure in Urban Salary and Wage-earners' Households -From 1982 to 1992-)

  • 김영숙
    • 대한가정학회지
    • /
    • 제32권2호
    • /
    • pp.1-16
    • /
    • 1994
  • This paper analysis the structure of Housing Consumption Expenditure of urban salary and wage-earners' households from 1982 to 1992 by employing Time-series. Data was based on " Annual report on the Family Income and Expenditure Survey" of the National Bureau of Statistic Planning Board, Republic of Korea. Percentile marginal-propensity to consume(MPC) and income elasticity of consumption expenditure are estimated by their socio-economic and demographic variables. The results are as follows: 1. The proportion of the expenditure for furniture and utensils and house mending has increased with the increase of income in urban salary and wage-earners' households, while fuel light and water charges and rents paid has decreased. 2.1) Engel Function by income group; MPC associated with rents paid and fuel light and water charges is higher in the lower income group than in the rest. The income elasticity estimates in rents paid and fuel light and water charges is less than 1 in all group while larger than 1 in furniture and utensils and house mending. 2) Engel Function by occupation of household head; The highest MPC in rents paid is associated with the sales profession. The income elasticity of fuel light and water charge is found be inelastic. The groups other than the sales group show irregular MPC. 3) Engel Function by family size; MPC in house mending and fuel light and water charge is increased while is decreased in rents paid in accordance with family size. The income elasticity of rents paid and fuel light and water charge is less than 1 in all groups while that of house mending and furniture and utensils is larger than 1. 4) Engel Function by age of housegold head; MPC in rents paid is decreased according to the age of housefold head. The income elasticity of rents paid and fuel light and water charge is less than 1 in all group while it is larger than 1.

  • PDF