• Title/Summary/Keyword: Water conductivity

Search Result 1,918, Processing Time 0.059 seconds

Growth Evaluation of 10 Cultivars of Creeping Bentgrass in Salt Affected Environment (염해지에서 크리핑벤트그래스 10개 품종의 생육 비교)

  • Kim, Jun-Beom;Yang, Geun-Mo;Choi, Joon-Soo
    • Asian Journal of Turfgrass Science
    • /
    • v.22 no.2
    • /
    • pp.149-160
    • /
    • 2008
  • This study was carried out to examine the growth performance of 10 cultivars of creeping bentgrass under salt injury in Seo-san reclaimed area. Turfgrass performance studies included 10 creeping bentgrass cultivars (T-1, L-93, Penn A1, Pennlinks II, Seaside II, Declaration, Penn A4, Crenshaw, Dominant, and Penncross). Ten creeping bentgrass cultivars were grown on a USGA recommended research green. Plots were seeded on May 31, 2006 at the rate of $7\;g{\cdot}m^{-1}$. Electric conductivities of irrigation water (ECw) and soil (ECe) were ranged from 0.28 to $3.3\;d\;S{\cdot}m^{-1}$ and from 0.25 to $3.5\;d\;S{\cdot}m^{-1}$ respectively. Leaf color, turf quality, coverage rate, and growth rate were checked under the salty condition in reclaimed land for 2 year. Creeping bentgrass cultivars of T-1, Penn links, and Crenshaw presented dark green color and Penn A1, Declaration showed lighter green color. Penn A1, Penn A4 and L-93 exhibited the highest overall turfgrass quality. Average visual coverage was 75.3% after eleven weeks after seeding. Dominant, L-93, and Penn A1 resulted in higher visual coverage compared to the other cultivars. There was no difference in density among cultivars at 1 year after establishment. However, Declaration, Penn A1, T-1, and L-93 showed higher density compared to the other cultivars at 2 years after seeding. Creeping bentgrass showed different quality, density and color in salty soil (ECe: $0.25-3.5\;d\;S{\cdot}m^{-1}$) and from application of salty irrigation water (ECw: $0.28-3.3\;d\;S{\cdot}m^{-1}$) conditions. These results will be useful where selecting green cultivars for the golf courses in reclaimed land area.

Detection of Sea-water Intrusion Caused by Tidal Action Using DC Resistivity Monitoring (전기비저항 모니터링을 이용한 해수침투 파악)

  • Hwang, Hak-Soo;Lee, Sang-Kyu;Ko, Dong-Chan;Kim, Yang-Soo;Park, In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • The 1 $km^2$ area studied is located in Sukchun-ri, Hwasung-koon, the southern part of Kyeonggi-do. Even though this site has been known as a contaminated area caused by seawater intrusions, geophysical and geochemical surveys have never been carried out at the site to determine the extent of the seawater contamination and to investigate whether the seawater intrusion is in progress. The purpose of this study is to determine the extent of seawater contamination and a preferred channel of the seawater intrusion using geophysical methods such as DC resistivity surveys with Schlumberger array and a dipole-dipole array. In order to determine whether the seawater intrusion is in progress in the area, DC resistivity monitoring with Schlumberger array was performed. According to the resistivity map obtained from the inversion of the resistivity data measured with Schlumberger array, the study area is divided into two districts as relatively lowly resistive (less than 30 ohm-m) and highly resistive (more than 30 ohm-m) areas. The distribution of the lowly resistive area is consistent with the distribution of the layer composed of clay minerals, and the resistivity of this layer decreases slowly as approaching to the old seashore. Hydrogeological analysis shows that the clay layer within a distance of about 200 m from the seashore has been already contaminated by sea-water and its electric conductivity is 8 times higher than that of the sand layer covered by the clay layer. According to the results of the 2-dimensional DC resistivity surveys with a dipole-dipole array, there are two preferred channels of the seawater intrusion in the site, and both the channels are in the NW-SE direction from the old seashore. The lowly resistive zone in the southern channel extends to a depth of 80 m. The DC resistivity monitoring with Schlumberger array was carried out along the preferred channel which has the low resistivity Bone (fracture zone) that extended to a depth of 80 m. The time series of apparent resistivity, measured at a distance of 260 m from the old coast line, fluctuates with a period of 12 hours. From these observations, it can be concluded that the seawater intrusion caused by tidal action is still in progress along the fractured zone interpreted by the DC resistivity surveys with a dipole-dipole array.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

Stability Analysis of the Unsaturated Infinite Slope Considering Suction Stress under Steady Infiltration Condition (정상침투조건에서 흡입응력을 고려한 불포화 무한사면의 안정해석)

  • Song, Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.9
    • /
    • pp.5-15
    • /
    • 2013
  • In this paper, the unsaturated slope stability analysis considering suction stress (Lu and Godt, 2008) was introduced and the results applied for a certain sand slope were analyzed. The unsaturated slope stability analysis considering suction stress can analyze both conditions of steady infiltration and no infiltration, and it can estimate the safety factor of slope as a function of soil depth. Also, the influence of weathering phenomenon at a certain depth from the ground surface can be considered. The stability analysis considering suction stress was applied to the unsaturated infinite slope composed of sand with the relative density of 60%. The suction stress under no infiltration condition was affected by ground water table until a certain influencing depth. However, the suction stress under steady infiltration condition was affected by seepage throughout the soils. Especially, the maximum suction stress was displayed around ground surface. The factor of safety in the infinite slope under no infiltration condition rapidly increased and decreased within the influence zone of ground water table. As a result of slope stability analysis, the factor of safety is less than 1 at the depth of 2.4 m below the ground surface. It means that the probability of slope failure is too high within the range of depths. The factor of safety under steady infiltration condition is greater than that under no infiltration condition due to the change of suction stress induced by seepage. As the steady infiltration rate of precipitation was getting closer to the saturated hydraulic conductivity, the factor of safety decreased. In case of the steady infiltration rate of precipitation with $-1.8{\times}10^{-3}cm/s$, the factor of safety is less than 1 at the depths between 0.2 m and 3 m below the ground surface. It means that the probability of slope failure is too high within the range of depths, and type of slope failure is likely to be shallow landslides.

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

Physicochemical Properties of Various Blends of Peatmoss and Perlite and the Selection of Rooting Media for Different Growing Seasons (다양한 종류의 피트모스와 펄라이트 혼합에 따른 물리·화학성 변화와 계절별 육묘를 위한 상토 선발)

  • Shim, Chang Yong;Kim, Chang Hyeon;Park, In Sook;Choi, Jong Myung
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.886-897
    • /
    • 2016
  • The physical properties of rooting media for the establishment of plugs in a greenhouse are modified according to variations in the greenhouse environment throughout the season. In this study, we established a standard for rooting media for the production of plug seedlings for each growing season (summer, winter and spring fall). Eight types of peatmoss (PM) and 4 types of perlite (PL) commonly used in Korea were collected and blended with the ratio of 7 parts PM to 3 parts PL (v/v) to make 32 different rooting media blends. We determined the total porosity (TP), container capacity (CC), air-filled porosity (AFP), pH, and electrical conductivity (EC) of the 32 media blends, and 6 media blends were selected for seasonal use. We also conducted additional analyses for plant easily available water (EAW), buffering water (BW), cation exchange capacity (CEC), and nutrient contents in the 6 media blends. The TP, CC, and AFP of the 32 media blends ranged from 64.7 to 96.0%, 42.9 to 90.1%, and 1.3 to 27.8%, respectively, indicating that the physical properties were strongly influenced by the type of PM and PL. The pH and EC of the PMs ranged from 2.96 to 3.81 and 0.08 to $0.47dS{\cdot}m^{-1}$, respectively. However, after blending the PM with the PL the pH was raised and the EC was lowered The media blends selected for the summer growing season were Blonde Golden peatmoss (BG) + No. 1 perlite size < 1 mm (PE1) and Latagro 0-10 mm (L1) + No. 2 perlite size 1-2 mm (PE2). These two media blends had 89.8-90.9% of TP, 80.8-81.3% of CC, and 9.0-9.7% of AFP. The media blends selected for the winter growing season were Sfagnumi Turvas (ST) + PE2 and Latagro 20-40 mm (L3) + PE2. These media blends had 79.9-86.7% of TP, 60.4-74.9% of CC, and 11.8-19.6% of AFP. The TP, CC, and AFP of two media blends, BG + No.3 perlite 2-5 mm (PE3) and Orange peatmoss (O) + PE3, selected for the spring and fall growing seasons, respectively, were 85.2-87.3%, 77.9%, and 7.4-9.4%, respectively. The percentage of EAW of the media blends selected for the spring, summer, and winter growing seasons ranged from 24.2-24.9%, 22.0-28.6%, and 18.0-21.8%, respectively, but the percentages of BW were not significantly different among the selected root media blends. The pH, EC, and CEC of the 6 selected media blends ranged from 3.11-3.97, $0.06-0.26dS{\cdot}m^{-1}$, and $97-119meq{\cdot}100g^{-1}$, respectively.

The Vertical Changes of Zooplankton Dynamics and Community Filtration Rate in the Artificial Lake (Okjeong Lake) (인공호수(옥정호)내 동물플랑크톤 동태 및 군집 여과율의 수직적 변화)

  • La, Geung-Hwan;Lee, Hak-Young;Kim, Hyun-Woo
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.4
    • /
    • pp.392-401
    • /
    • 2008
  • The vertical changes (upper layer: 0$\sim$0.5 m, middle layer: 4$\sim$5 m and lower layer: 8$\sim$10 m) of the limnological variables, zooplankton dynamics and community filtration rate on the phytoplankton were evaluated monthly intervals from November 2004 to June 2007 at the artificiallake (Okjeong Lake). During the study, the annual mean of water temperatures were 15.2$\pm$7.8$^{\circ}C$ (upper layer), 14.5$\pm$7.4$^{\circ}C$ (middle layer) and 13.0$\pm$6.2$^{\circ}C$ (lower layer), respectively (n=30). The vertical variations of most limnological parameters (DO, pH, conductivity and turbidity) were fairly similar, except for chl.-${\alpha}$ concentration. Annual mean of chl.-${\alpha}$ concentration was highest at the upper layer (21.4 ${\mu}g$ L$^{-1}$), while annual means of concentrations were low at the middle layer and lower layer (4.3 ${\mu}g$ L$^{-1}$ and 3.5 ${\mu}g$ L$^{-1}$, respectively). Annual mean of Secchi depth was 261 cm (n=30). A total 45 species of zooplankton were identified (28 rotifers, 12 cladocerans and 5 copepods) during the study. The mean abundance of rotifers was highest (124$\pm$232 ind. L$^{-1}$, n =90) and that of cladocerans and copepods were relatively low (22$\pm$56 ind. L$^{-1}$ and 13$\pm$30 ind. L$^{-1}$) in the whole layer. Total zooplankton abundance increased from late spring to summer, and then declined and remained low throughout the winter. The annual mean of total zooplankton filtration rate for phytoplankton at the lower layer was much higher than that of both layers (upper layer: 44.4$\pm$107.8, middle layer: 95.1$\pm$436.4 and lower layer: 158.2$\pm$436.4 mL L$^{-1}$ day$^{-1}$). Among the major zooplankton community, relative community filtration rate (RCFR, %) of copepods for phytoplankton (50.2$\sim$54.8%) was much higher than that of cladocerans (27.7$\sim$36.3%) and rotifers (8$\sim$17.6%). The seasonal variation of RCFRs of major zooplankton community was observed. The RCFRs of rotifers were high in winter (44.6%, n=9), while the RCFRs of cladocerans were high in summer (58.0%, n=7). In spring and fall, the RCFRs of copepods were high in the whole layer (spring: 67.4%, n=9; fall: 74.4%, n=5).

Effect of Soil Salinity on Growth, Yield and Nutrients Uptake of Whole Crop Barley in Newly Reclaimed Land (신간척지에서 토양 염농도가 청보리 생육, 수량 및 양분 흡수에 미치는 영향)

  • Lee, Sang-Bok;Cho, Kwang-Min;Shin, Pyung;Yang, Chang-Hyu;Back, Nam-Hyun;Lee, Kyeong-Bo;Baek, Seung-Hwa;Chung, Doug-Young
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.4
    • /
    • pp.332-337
    • /
    • 2013
  • BACKGROUND: Newly reclaimed land has poor soil environment for crop growth since it is high in salt concentration but low in organic content compared with ordinary soil. It is known that whole-crop-barley can grow better in the soil of relatively high salt concentration than other crops but, the growth is poor at the concentration if higher than certain amount and it is a difficulty to secure productivity. Hence, the level of soil salt concentration suitable for the production of bulky feed in newly reclaimed land has been investigated. METHODS AND RESULTS: At Saemanguem reclaimed land, the land for the soil salt concentration electrical conductivity (EC) 0.8, 3.1, 6.5, 11.0 dS/m was selected; and chemical fertilizer $N-P_2O_5-K_2O$ (150-100-100kg/ha) was tested; and forage barley 220kg/ha were sown. The soil salt concentration during the cultivation period decreased in the order of harvest season>earing season>sowing season>wintering season, and the salt concentration in harvest season is 1.4-4.2 times higher than that of the sowing season. The higher the salt concentration, the poorer the over ground growth due to poor rooting; especially at EC 11.0 ds/m there was emergence but, it blighted after wintering. The Yield from the soil salt concentration 3.1dS/m and 6.5 dS/m was 68% and 35% from that of the soil salt concentration 0.8 dS/m (8.8 MT/ha) respectively. The proline content in early life stage was more than that of the harvest season, and it increased with salt concentration. The higher salt concentration, the more $Na_2O$ and MgO content in harvest season; but the higher the salt concentration, the less the content of N, $P_2O_5$, $K_2O$ and CaO. CONCLUSION(S): When the soil salt concentration becomes higher than 3.1 dS/m, the yield becomes poor because there is serious growth inhibition of forage barley both in root part and above aerial part that results in unbalanced absorption of nutrients. Therefore, it is recommended that the salt concentration should be lowered below 3.1 dS/m by underground drainage facilities or irrigating water for the stable production of whole-crop-barley.

Hydrogeochemistry and Origin of $CO_2$ and Noble Gases in the Dalki Carbonate Waters of the Chungsong Area (청송 달기탄산약수의 수리지화학과 탄산 및 영족기체 기원)

  • Jeong, Chan-Ho;Kim, Kyu-Han;Nagao, Keisuke
    • The Journal of Engineering Geology
    • /
    • v.22 no.1
    • /
    • pp.123-134
    • /
    • 2012
  • Hydrochemical analyses, carbon isotopic (${\delta}^{13}C_{DIC}$) analyses, and noble gas isotopic ($^3He/^4He$ and $^4He/^{20}Ne$) analyses of the Dalki carbonate waters in the Chungsong area were carried out to elucidate their hydrochemical composition and to determine the source of $CO_2$ gas and noble gases. The carbonate waters have a pH of between 5.93 and 6.33, and an electrical conductivity 1950 to $3030{\mu}S/cm$. The chemical composition of all carbonate waters was Ca(Mg)-$HCO_3$, with a high Na content. The contents of Fe, Mn, and As in some carbonate waters exceed the limit stipulated for drinking water. The concentrations of major ions are slightly higher than those reported previously. The ${\delta}^{13}C_{DIC}$ values range from -6.70‰ to -4.47‰, indicating that the carbon originated from a deep-seated source. The $^3He/^4He$ and $^4He/^{20}Ne$ ratios vary from $7.67{\times}10^{-6}$ to $8.38{\times}10^{-6}$ and from 21.32 to 725.7, respectively. On the $^3He/^4He$ versus $^4He/^{20}Ne$ diagram, the noble gas isotope ratios plot in the field of a deep-seated source, such as mantle or magma. We therefore conclude that $CO_2$ gas and noble gas in the Dalki carbonate waters originated from a deep-seated source, rather than an inorganic $CO_2$ origin as suggested in a previous study.

Allyl-isothiocyanate Content and Physiological Responses of Wasabia japonica Matusum as Affected by Different EC Levels in Hydroponics (고추냉이 수경재배시 배양액의 EC 수준이 Allyl-isothiocyanate 함량과 생리적 반응에 미치는 영향)

  • Choi, Ki-Young;Lee, Yong-Beom;Cho, Young-Yeol
    • Horticultural Science & Technology
    • /
    • v.29 no.4
    • /
    • pp.311-316
    • /
    • 2011
  • This study aimed to determine the effect of EC (electrical conductivity) levels of nutrient solution in hydroponic culture on allyl-isothiocyanate (AITC) content within plant tissues, Vitamin C content and physiological responses in wasabi plant (Wasabia japonica M. 'Darma'). The 'Darma' was grown for 5 weeks with a deep flow technique (DFT) system controlled at 5 different EC levels, including 0.5, 1, 2, 3, and $5dS{\cdot}m^{-1}$. In result, the highest total content of AITC showed at EC level 5 and $3dS{\cdot}m^{-1}$ for 1 or 5- week, respectively. The total content of AITC increased about 1.2-1.4 times when the plants were grown in the EC levels between 0.5 and $2dS{\cdot}m^{-1}$, whereas the content decreased about 6 and 56 % in the EC level 3 and $5dS{\cdot}m^{-1}$, respectively. The content of AITC was relatively higher in petiole tissue, about 53 %, taken from 1 week-grown plants when the EC was controlled between 0.5 and $2dS{\cdot}m^{-1}$. Root tissue also had relatively higher content of AITC, about 45.1 %, when the EC was controlled at 3 and $5dS{\cdot}m^{-1}$. However, a 5-fold decrease in the AITC content was found in blade tissue and a 6.8-fold decrease in root when the EC was controlled at $5dS{\cdot}m^{-1}$ for 5 weeks. There was no significant difference in the vitamin C content in 1-week grown leaf tissues under the different EC level treatments; but, the content increased about 27% in 5-week grown plants at the EC level between 0.5 and $2dS{\cdot}m^{-1}$, compared to the 1 week-grown leaf tissue. Electrolyte leakage of leaf tissue taken from 3-week grown plant was 3-fold higher at the EC level $5dS{\cdot}m^{-1}$, compared to the EC level between 0.5 and $2dS{\cdot}m^{-1}$. Chlorophyll content, photosynthesis rate and transpiration rate were decreased when the EC was controlled at higher than $2dS{\cdot}m^{-1}$. Leaf water content, specific leaf area and growth were decreased when the EC was controlled at $5dS{\cdot}m^{-1}$ for 5 weeks. All the integrated results in this study suggest that the EC level of nutrient solution should be maintained at lower than $3dS{\cdot}m^{-1}$ in order to improve nutritional value and quantity required for hydroponically grown wasabi as functional vegetable.