• Title/Summary/Keyword: Water condition

Search Result 8,173, Processing Time 0.034 seconds

Parallel Reservoir Analysis of Drought Period by Water Supply Allocation Method (공급량 배분기법을 이용한 갈수기 병렬저수지 해석)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2006
  • In this study, an optimization technique was developed from the application of allocation rule. The results obtained from the water supply analysis and reliability indices analysis of Andong dam and Imha dam which are consist of parallel reservoir system are summarized as the followings; Allocation rule(C) is effective technique at the parallel reservoir system because results of the water supply analysis, storage analysis and reliability indices analysis is calculated reasonable results. Also, reliability indices analysis results are not sufficient occurrence based reliability or quantity based reliability. Thus reliability indices analysis are need as occurrence based reliability, quantity based reliability vulnerability, resilience, average water supply deficits and average storage. And water supply condition is better varying water supply condition than constant water supply condition.

Stability Analysis of Slope in Unsaturated Soil Based on the Characteristics of Rainfall (강우특성을 고려한 불포화토 사면의 안정성 해석)

  • Lee, Gwan-Young;Lee, Kang-Il;Kim, Chan-Kee;Chang, Yong-Chai
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.663-668
    • /
    • 2005
  • The present study proposed to examine the appropriateness of the ground water level condition that had a significant effect on the stability of the slopes and, for this purpose, analyzed the rise of ground water level during the rainy season by applying the average daily rainfall of Seoul for the last 30 years. The result showed that the rise of ground water level was 6.0$\sim$41.0% of the slope height, which suggests that the currently applied condition of ground water level is somewhat overestimated. In addition, the result of interpreting the stability of slopes during the rainy season, slopes were unstable in all conditions when the ground water level was at the ground surface and base failure occurred. This suggests the importance of ground water level condition in stability analysis.

  • PDF

On the Distribution of Water Temperature in the Warm Water Pool. -On the Wudu Warm Water Pool- (온수지에서의 수온분포에 관한 연구 -우두온수지를 중심으로-)

  • 연규석;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.121-126
    • /
    • 1979
  • The objective of this study was to grasp the condition of the distribution of water temperature in the warm water pool, and these observations were performed in Wudu warm water pool located at Wodu-Dong in Chuncheon. The results summarized in this study are as follows; 1. The horizontal distribution charts of water temperature at each depth of points were shown as Fig. 3, Fig. 4, and Fig. 5, respectively. In consequence of the observation, the condition of warm water was stagnant in the coner of warm water pool. As the result, it was found out that stagnant condition was the heaviest at water surface (depth; 0.05m), more heavier at middle depth (depth; 0.55m) and some heavy at bottom of the pool (depth; 1.10m). 2. The vertical water temperature change was shown as Fig. 6, and the mean water temperature of water surface (depth;0.05m) was higher about $2.2{\sim}3.3^{\circ}C$ than bottom water temperature. 3. Therefore, it was required to device such structures as form of broad cannels or overflow diversion weirs to mingle with top and bottom water.

  • PDF

A study of the performance on large capacity screw compressors (중대형 스크루 압축기의 성능에 관한 연구)

  • Park, D.S.;Yang, S.H.;Lee, D.J.;Shin, J.K.;Yoo, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.668-671
    • /
    • 2001
  • For the saving of energy consumption, it is necessary that the high efficient energy transfer machine. We found the optimum operating condition of screw water chiller during this performance test. The specifications of compressor for this performance test are as follows. Built-in volume ratio; Vi=2.4, using refrigerant; HCFC-22, nominal motor output; 60kW(80Hp). We found the test results on water cooled chiller standard test condition that the evaporating capacity is increased 8% maximum and 5.6% under same operating condition. and COP is increased 11 % max. and 8% under same operating condition with change of the evaporating inlet/outlet condition. For the results of these test, we can estimate the optimum operating condition of water cooled type screw chiller.

  • PDF

Application of tubular membrane to thickening process as a pre-treatment of anaerobic digester (관형막을 이용한 혐기소화조의 전처리 농축공정으로써 적용가능성 연구)

  • Kang, Hee-Seok;Park, Ki-Tae;Park, Jung-Woo;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.203-209
    • /
    • 2015
  • The purpose of this study is to estimate the applicability of a stable anaerobic digester using a separator membrane to the preprocessing thickening process. The results of the experiments showed about a 47.16% weight loss rate for the sludge under anaerobic condition, and about 41.17% under intermittent aeration condition. The concentrations of rejection water were $SCOD_{Cr}$ 25 mg/L, T-N 16.6 mg/L, and T-P 1.4 mg/L on the average under the intermittent aeration condition, which were lower than the concentrations of rejection water under an anaerobic condition. As for the factors affecting the reduction of the flux, correlation analyses of TTF, MLSS, $SCOD_{Cr}$, and $EPS_{Protein}$, $EPS_{Polysacchride}$ resulted in -0.97, -0.95, -0.84 and -0.86, -0.95, respectively, which showed that TTF had the highest correlation to the reduction of the flux. In addition, it was concluded that MLSS, $SCOD_{Cr}$ and $EPS_{Protein}$, $EPS_{Polysacchride}$ also have close correlations. The results are considered to show that, in the case of the process using a tubular membrane in the preprocessing process of an anaerobic digester, an intermittent aeration condition of the thickener considering the contamination of the membrane and load of rejection water is appropriate for the stable preprocessing process.

Wave deformation due to oscillating water column plant (OWC 플랜트 주위 파랑변형)

  • 김용직;김동준;윤길수;류청로;홍석원
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.77-90
    • /
    • 1997
  • Wave deformation due to Oscillating water column (OWC) plant was studied. To solve this problem, three dimensional numerical method based on Improved Green integral equation was applied. Method condition was considered as well as fixed condition and freely floating condition. From the calculation results, main characteriatic of wave deformation due to OWC plant were discussed. Also, some calculations for the floating barge were performed to confirm the validity of numerical solution of the method.

  • PDF

Effects of Soil Moisture on the Growth of Acer Palmatum under Indoor Low Light Intensity (실내의 저광도하에서 토양수분이 단풍나무의 생육에 미치는 영향)

  • 윤지영;김민수
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.4
    • /
    • pp.21-28
    • /
    • 2000
  • This study is conducted to analyze effects of soil moisture on the growth of maple(Acer palmatum) under indoor low light intensity. Maples grew under three different light intensities such as sunny place(average 353.2W/$m^2$), half shade(average 7.7 W/$m^2$) and shade/(average 1.9W/$m^2$).Under half shady and shady condition, each 24 planters(2 maples planted in each planter) were used and divided into 3 groups treated with different watering points. Three levels of soil water potential were set for watering points, such as -200mbar, -300mbar or -500mbar. Under sunny condition, there were only group of 8 planters, as comparison. Watering was applied when soil water potentials reached -500maber. The results of plant growth experiment are as followed. 1. Under the shady condition, 32 maples died among 48 maples for 7 months. 9 maples survived, watered at soil water potential -200mbar, 5maples at -300mbar and 2maples at -500mbar. 2. Leaf water content ratios were higher under lower light intensity. For the cell wall became thinner under lower light intensity. 3. Maples in shady were easy to die due to having thin cell wall, therefore they were easy to loss the turgor pressure. 4. In case of half shady condition, the group, watered at soil water potential -200mbar, had much smaller amount of rootlet than -300mbar, because there were excessive soil water. The group, watered at soil water potential -500mbar, had smaller amount of rootlet than -300mbar and there was a remarkable difference in leaf water potential in spite of nearly same soil water potential, because leaves received the water stress under lower soil water potential. 5. When maples grew soundly, the leaf water potential was largely influenced by the soil water potential.

  • PDF

The Behavior of Undrained Pore Water Pressure in Normally Consolidated and Saturated Clay(II) - Visco Elastic Analysis Model - (포화된 정규압밀 점성토에서 비배수 공극수압의 거동(II) - 점탄성 해석 모델 -)

  • 임성훈
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.4
    • /
    • pp.137-143
    • /
    • 2003
  • The initial condition of $\Delta \sigma_3 \;=\; \Delta u$ is used for analyzing the time dependent behavior of ground. This is based on the concept that the coefficient of pore water B is the unity on the condition of saturation. but some measured consolidation data in the field showed that the pore water pressure was not dissipated as time elapsed but it was maintained constant value or it's dissipation rate was slower than that of the predicted. and so the measured data of pore water pressure was not consistent with that of settlement. In this study, the rheological model for the pore water pressure behavior on undrained condition was induced and compared with the experiment data of the literature. The result showed that the suggested model was consistent well with the result of experiment, but the suggested model could not explain the effect of the decrease of void ratio according to consolidation.

Using LNAPL to Enhance in situ Oxygen Transfer: (II) Biotic Condition (LNAPL을 이용한 지중 산소전달 향상: (II) Biotic Condition)

  • Ha, Jeong-Hyub;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.337-342
    • /
    • 2004
  • Previous experiment was performed under abiotic condition. Steady-state abiotic experiments in the sand-tank reactor with air flowing through the reactor headspace demonstrated that oxygen supply through the water table interface into the saturated zone was enhanced when an LNAPL (dodecane) pool was present at the water table. Biotic condition was considered in this study. Biotic experiments performed after inoculating the reactor with Pseudomonas putida mt-2, which does not grow on dodecane, indicated that the enhanced oxygen supply in the presence of the LNAPL pool also enhanced biodegradation of a solute (glucose) plume passing beneath the LNAPL pool at steady-state.

A Study on the Degradation Characteristics of EPN (EPN의 분해특성에 관한 연구)

  • 이용두;김현희;김창영
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1103-1108
    • /
    • 2002
  • In order to evaluate the degradation organophosphorus pesticide, EPN, in water environment, the effects of water temp.(10$^{circ}C,\;30^{\circ}C$), pH(3-11) and sunlight on its degradation were investigated during 10 days. The degradation rate of EPN(200 rpm) was faster at higher water temp. and higher pH, i.e., its degradation rate at pH 3, 5, 7, 9, 11 was 57, 63, 66, 69, 75%(1$0^{\circ}C$), and 70, 74, 79, 91, 97%(3$0^{\circ}C$) after 10 days, respectively. The effect of water temp. on its degradation was little in acidic condition, but was rather great in alkaline condition, with time. EPN was degraded fast at the alkaline condition by photolysis. At the condition of pH 11, EPN was degraded fast at the early stage in the first 2 days, but after that the degradation rate was weakened.