• 제목/요약/키워드: Water condensation

검색결과 474건 처리시간 0.023초

공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰- (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 -)

  • 최영돈;강용태;김내현;김만회;박경근;박병윤;박진철;홍희기
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

EXPERIMENTAL SIMULATION OF A DIRECT VESSEL INJECTION LINE BREAK OF THE APR1400 WITH THE ATLAS

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Kang, Kyoung-Ho;Choi, Nan-Hyun;Kim, Dae-Hun;Park, Choon-Kyung;Kim, Yeon-Sik;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.655-676
    • /
    • 2009
  • The first-ever integral effect test for simulating a guillotine break of a DVI (Direct Vessel Injection) line of the APR1400 was carried out with the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) from the same prototypic pressure and temperature conditions as those of the APR1400. The major thermal hydraulic behaviors during a DVI line break accident were identified and investigated experimentally. A method for estimating the break flow based on a balance between the change in RCS inventory and the injection flow is proposed to overcome a direct break low measurement deficiency. A post-test calculation was performed with a best-estimate safety analysis code MARS 3.1 to examine its prediction capability and to identify any code deficiencies for the thermal hydraulic phenomena occurring during the DVI line break accidents. On the whole, the prediction of the MARS code shows a good agreement with the measured data. However, the code predicted a higher core level than did the data just before a loop seal clearing occurs, leading to no increase in the peak cladding temperature. The code also produced a more rapid decrease in the downcomer water level than was predicted by the data. These observable disagreements are thought to be caused by uncertainties in predicting countercurrent flow or condensation phenomena in a downcomer region. The present integral effect test data will be used to support the present conservative safety analysis methodology and to develop a new best-estimate safety analysis methodology for DVI line break accidents of the APR1400.

유근피(楡根皮) 추출액(抽出液)이 HeoG2 간암세포(肝癌細胞)에 미치는 항암효과(抗癌效果) 및 기전(機轉)에 대(對)한 연구(硏究) (A Study on Antitumor Effect and Mechanism of Cortex ulmi pumilae Water Extract on HepG2 Hepatoma cell)

  • 최수덕;박용권;김강산;강병기;한상일
    • 대한한방내과학회지
    • /
    • 제21권2호
    • /
    • pp.259-266
    • /
    • 2000
  • Objectives : The effects of aqueous extracts of Cortex ulmi pumilae (a traditional medicine for cancer treatment in oriental medicine) on the induction of apoptotic cell death were investigated in human liver origm hepatoma cell lines, HepG2. Methods : The death of HepG2 cells was markedly induced by the addition of extracts of Cortex ulmi pumilae in a dose-dependent manner. The apoptotic characteristic ladder pattern of DNA strand break was not observed in cell death of HepG2. In addition, it was not shown nucleus chromatin condensation and fragmentation under hoechst staining. However, by the using annexin V staining assay, externalizations of phosphatidylserine in HepG2 cell which were treated with Cortex ulmi pumilae extracts were detected in the early time (at 9 hr after extract treatment). Furthermore, LDH release was not detected in this early stage. Therefore, Cortex ulmi pumilae extracts-induced cell death of HepG2 cells is mediated by apoptotic death signal processes. Result : The activity of caspase 3-like proteases remained in a basal level in HepG2 cells which treated with the extract of Cordyceps sinensis. However, it was markedly increased in HepG2 cells which treated with two extracts of Cortex ulmi pumilae (C.U.P.-C, C.U.P.-K) which were differently extracted (respectively, 2.3 and 3.3 fold). On a while, the phosphotransferase activities of JNK1 was markedly induced in HepG2 cells which were treated with two extracts of Cortex ulmi pumilae. On the contrary, the activation of transcriptional activator, activating protein1(AP-1) and NF-kB were severely decreased by these two extracts of Cortex ulmi pumilae (C.U.P.-C, C.U.P.-K). In addition, antioxidants (GSH and NAC) and intracellular $Ca2^+$ level regulator (Bapta/AM and Thapsigargin) did not affect Cortex ulmi pumilae extracts-induced apoptotic death of HepG2 cells. Conclusions : In conclusion, our results suggest that two extracts of Cortex ulmi pumilae (C.U.P.-C, C.U.P.-K) induces the apoptotic death of human liver origin hepatoma HepG2 cells via activation of caspase 3-like proteases as well as JNK1, and inhibition of transcriptional activators, AP-1 and $NK-{\kappa}B$.

  • PDF

엔진 폐열 회수를 위한 이중 회로 랭킨 사이클 성능 해석 (Performance Analysis of Two-Loop Rankine Cycle for Engine Waste Heat Recovery)

  • 김영민;신동길;김창기;우세종;최병철
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.402-410
    • /
    • 2012
  • 본 연구에서는 가솔린 엔진 자동차에서 엔진 폐열 회수를 위한 이중 회로 랭킨 사이클 성능 해석이 수행되었다. 고온(HT)의 엔진 배기가스 열회수를 위해서는 물을 사용하는 스팀사이클이 적용되었고, 엔진 냉각수열과 고온 사이클로부터의 응축열을 활용하는 저온(LT) 사이클은 R-134a를 사용하는 유기랭킨사이클이 적용되었다. 고온 및 저온 열원을 동시에 활용하는 이중 회로 시스템의 특성을 파악하기 위해 에너지 및 엑서지 분석이 수행되었다. 고온 및 저온 사이클에 사용되는 용적형 팽창기의 체적이 차량적용을 위한 시스템 최적화에 매우 중요하며 시스템 최적화를 위해서는 반드시 고려되어야 한다. 목표로 하는 엔진 운전 조건에서 고온(HT) 팽창기와 저온(LT) 팽창기의 체적을 고려하면서 고온(HT) 사이클의 팽창비와 저온(LT) 사이클의 응축온도가 시스템의 성능에 미치는 영향을 파악하였다. 본 연구에서는 이러한 이중 회로 랭킨 사이클 시스템에 의해 목표 엔진 운전조건에서 엔진 폐열로부터 약 21%의 추가 동력을 얻을 수 있는 것으로 예측되었다.

열교환기 형상에 따른 분리형 히트파이프 성능 비교 (Separate type heat pipe performance comparison by the heat exchanger shapes)

  • 전성택;조진표
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.723-729
    • /
    • 2016
  • 본 연구에서는 핀-관형 히트파이프와 평행류형 히트파이프 제작하여 시험하였으며 분리형 히트파이프의 작동유체의 충진량은 40~60(% vol.), 풍량은 300~1,400 사이에서 변화시켜가며 온도교환 효율, 열회수량, 공기측 압력강하를 비교하였다. 온도교환 효율은 두 종류의 히트파이프 모든 경우에서 저 풍량에서는 작동유체 충진량이 40(%vol.)일 때가 가장 높았으며 풍량이 증가함에 따라 최대 효율을 가지는 작동유체 충진량이 다름을 알 수 있었고, 환기량이 작을수록 온도교환 효율이 높게 나타났다. 평행류형 히트파이프 60(%vol.)의 실험결과에서 보는 것과 같이 작동 유체를 너무 많이 충진하게 되면 오히려 낮은 온도교환 효율을 보이는데 이는 관벽의 액막이 두터워지면서 열전달 효과를 악화시킨 결과로 최적 충진량이 40~50(%vol.) 사이에 있음을 알 수 있다. 풍량 변화에 따른 공기측 압력강하 비교에서는 증발부 히트파이프가 응축부 히트파이프 보다 크게 계측 되었는데 증발부 표면에 생긴 결로수의 영향으로 생각된다. 평행류형 히트파이프는 핀-관형 히트파이프와 비교하여 냉매 충진량은 48%, 체적은 41%에서 동등이상의 성능을 보였으며, 공기측 압력강하도 37% 정도로 좋은 성능을 나타내었다.

N-Acyl Taurates의 환경친화적인 제조공정 개발 및 이의 물성 연구 (Development of Environmental-friendly N-Acyl Taurates Manufacturing Process and Evaluation of their Physical Properties)

  • 박지나;송아람;정용우;배재흠;지흥진;임호
    • 청정기술
    • /
    • 제11권4호
    • /
    • pp.195-204
    • /
    • 2005
  • 기존 공정에 비하여 오염물 발생이 적고 수율이 60 % 이상의 환경친화적인 새로운 N-acyl taurate 단일축합공정을 개발하였다. 개발된 공정의 최적 운전조건은 석유계 정제유인 parasol 123 용매와 반응촉매로 sulfone산계 촉매와 인산계 촉매의 혼합촉매를 사용할 때 반응온도가 $210{\sim}230^{\circ}C$이며 반응시간이 6 ~ 9시간 이었다. 이렇게 제조된 제품은 기존 수입된 N-acyl taurate와 비교하여 산가, 아민가, 색상 등의 물성이 비슷하거나 더 좋고 부산물도 적게 배출되어 본 연구에서 개발된 공정이 기존 공정보다 우수한 공정이라고 할 수 있다. 그리고 본 연구에서 제조된 N-acyl taurate를 시판 음이온 계면활성제와 표면장력, 기포력, 기포안정성, 경수안정성, 유화력 등의 물성을 비교할 때 동등 이상의 물성을 보여 기존의 음이온 계면활성제를 충분히 대체할 수 있음을 확인할 수 있었다.

  • PDF

9,9'-비스[4-(글라이시딜옥시)페닐]플루오렌의 효율적 제법 (Improved Procedure for the Preparation of 9,9'-bis[4-(glycidyloxy)phenyl]fluorene)

  • 김진원;심재진;나춘섭
    • 청정기술
    • /
    • 제18권3호
    • /
    • pp.325-328
    • /
    • 2012
  • 플로렌 구조를 가진 다양한 에폭시 수지의 합성 전구물질 9,9'-비스[4-(2'-하이드록시-3'-아크릴로일옥시프로폭시)페닐]플루오렌(2)을 에 대한 효율적 제법을 연구하였다. 화합물(2)는 비스(4-하이드록시페닐)플루오렌과 에피클로로하이드린의 축합 반응에서 얻어졌으며 반응 수율은 여러 가지 실험적 조건(반응 온도와 시간, 에피클로로하이드린의 사용량, 촉매와 용매의 사용 등)에 민감하게 변화하였다. 이들의 반응 수율에 미치는 효과에 대한 실험적 결과를 기술하고 논의하였다. 373 K이하의 반응온도에서 1.5시간 이하의 반응시간을 유지함으로써 부생성물의 생성을 최소화할 수 있었으며, 톨루엔/DMSO/물의 혼합용매를 사용하여 반응온도를 적절히 조절하고 생성물을 용이하게 정제할 수 있었다. 여러 사차 암모늄염을 이 반응의 촉매로 이용할 수 있었다. 본 연구를 통하여 적은 양의 반응물질을 사용하고, 화학적 폐기물의 생성은 최소화하는 용이한 정제방법을 확립했으며 반응 온도를 낮추어 에너지의 사용을 감소시킴으로써 9,9'-비스[4-(2'-하이드록시-3'-아크릴로일옥시프로폭시)페닐]플루오렌 제조 방법에 대한 환경친화성을 높일 수 있었다.

소경 굴참나무 횡절 원판의 강제송풍천연건조 (Forced Air-drying of Cross-cut Disks from Small-diameter Logs of Quercus variabilis)

  • 이준우;강춘원;박로원;강호양
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권1호
    • /
    • pp.52-59
    • /
    • 2015
  • 소경 참나무 횡절목을 열처리하여 브로치 등 악세사리용 소재로 개발하였다. 그러나 국산참나무는 난건조수종으로 특히 횡절 원판을 건조결함없이 건조하기 어렵다. 소경 굴참나무(Quercus variabilis)에서 얻은 원판(섬유방향 길이 7 mm)을 여름과 가을에 강제송풍천연건조하면서 여러 조건에 따른 건조수율을 조사하였다. 같은 조건에서 가을에 건조한 시편의 최종 평균함수율이 여름에 건조한 시편의 평균함수율보다 낮았다. 두 계절 모두 큰 직경의 시편은 풍속에 따른 차이를 보이지 않았으나 작은 직경의 시편은 풍속이 높았을 때 최종 평균함수율이 약간 낮았다. 두 계절 모두 직경이 큰 시편의 할렬 발생빈도가 직경이 작은 시편보다 높았는데 가을에는 2배 정도인데 반해 여름에는 4배가 넘었다. 여름에 낮은 풍속에서 건조한 큰 직경 시편의 할렬 발생빈도가 높은 이유는 여름의 높은 습도와 낮은 풍속으로 반복적인 수분 응축과 증발이 일어났기 때문으로 설명할 수 있다.

역마이셀에 의한 TiO(OH)$_2$ 미세분말 제조 (Formation of TiO(OH)$_2$ Ultrafine Particles by Reverse Micelle)

  • 장화익;강석원;이광래
    • 한국세라믹학회지
    • /
    • 제35권6호
    • /
    • pp.594-602
    • /
    • 1998
  • 유기용메인 이소옥탄(isooctane)에 계면활성제를 이용하여 물을 역마이셀 형태로 생성시킨 후, 이소프로필 알코올(isopropyle alcohol)에 묽힌 티타늄알코옥사이드(tetraisopropyl orthotitanate)를 가하여 가수분해 반응를 거쳐 TiO(OH)2 분말을 제조하였다. 역마이셀에 의한 TiO(OH)2 분말 제조에 미치는 공정변수들인 계면활성제의 종류, 농도, 보조계면활성제, 가수분해 반응온도, pH등이 생성된 입자의 크기, 모양, 입도분포에 미치는 영향을 규명하였다. 비이온계활성제인 Span 80을 사용하였을 경우에는 Span 80의 농도변화, 가수분해 반응온도 변화, pH변화에 무관하게 입도분포가 uninodal형태였으나, 음이온계면활성제인 Aerosol-OT(AOT)를 사용하였을 경우, binodal형태를 나타내었다. 에타올(ethanol)을 cosurfactant로 첨가한 계(AOT, 1.0CMC, isooctane+ethanol, pH2.5, 30$^{\circ}C$)로 부터 생성된 입자는 평균입경이 0.12${\mu}{\textrm}{m}$ 으로서 미세할 뿐아니라 입도분포도 매우 좁은 것을 알 수 있다. 따라서, cosurfactant의 유무가 생성 입자의 입도분포에 큰 영향을 미치는 것을 알 수 있다. FT-IR 분석으로 T1-O 결합과 Ti-OH 결합에 의한 흡수피크를 확인하였고, TGA-DTA 분석결과에 의하면 41$0^{\circ}C$ 부근의 발열피크로 부터 비정질 구조에서 anatase 구조로 결정화가 시작됨을 알 수 있었으며, 온도 상승과 더불어 결정이 성장하여 약 45$0^{\circ}C$ 정도에서 비정질상이 anatase상의 결정구조로 완전히 전이됨을 확인하였다.

  • PDF

공동주택 하자보수보증기간에 기초한 공종별 하자위험 분석 (Analysis of Defect Risk by Work Types based on Warranty Liability Period in Apartments)

  • 김상현;김재준
    • 한국건설관리학회논문집
    • /
    • 제19권4호
    • /
    • pp.34-42
    • /
    • 2018
  • 공동주택은 국민 대다수가 선호하는 대표적인 주거양식으로 자리매김한 반면, 완공된 공동주택의 기초 골조 설비 마감 및 조경 등의 수많은 구조체와 마감재에서 균열 침하 파손 누수 결로 및 탈락 등의 다양한 결함이 발생하여 하자없는 신축 공동주택을 원하는 입주자와 하자가 발생하는 것은 불가피하다고 주장하는 사업주체간에 분쟁이 지속적으로 발생하고 있다. 이러한 하자분쟁은 입주자와 건설업체 모두에게 경제적 손실을 발생시킨다. 이러한 관점에서 본 논문에서는 하자분쟁사례를 활용하여 공종별 각 보증기간의 하자보수 빈도 및 비용을 분석하고, 이를 종합하여 공종별 각 보증기간의 하자보수위험을 평가하여 하자보수보증금 산정에 대한 시사점을 도출하는 것을 목적으로 한다. 이를 위해 본 논문에서는 준공 이후 10년 이상된 공동주택 하자분쟁사례 32건, 5337개의 하자아이템을 활용하여 공종별 각 보증기간의 하자보수위험을 평가하였다. 하자빈도와 하자비용을 종합하여 공종별 하자보수보증기간의 하자비용을 분석한 결과, 철근콘크리트공사와 마감공사의 하자위험이 매우 높은 것으로 파악되었다. 이는 결국 하자보수보증금이 일률적으로 연차별로 배분되어 있는 것에 문제점이 있음을 나타낸다. 또한 하자보수보증금의 경과년수에 따른 반환비율과 경과년수에 따른 하자위험을 비교한 결과, 기존 반환비율에 대한 조정이 필요할 것으로 나타났다.