• 제목/요약/키워드: Water condensation

검색결과 476건 처리시간 0.032초

응축폐열을 이용한 건조 및 온수장치에 관한 연구 (A Study on The Drying and Hot Water System Using Condensation Waste Heat)

  • 박노현;고하영;정진웅;강통삼
    • 대한설비공학회지:설비저널
    • /
    • 제15권4호
    • /
    • pp.362-371
    • /
    • 1986
  • In the normal Refrigeration process, the condensation heat of refrigerant s not been used because of its low-temperature waste heat. To recover the condensation waste heat of R-12 refrigerator, a drying and hot water system was designed and experimented. The results obtained were summarized as follows: 1. As the temperature a temosphere was increased, the temperature of discharge gas of compressor was increased. And the temperature was $80-84^{\circ}C$ for air condensing type and was $68-71^{\circ}C$ for water condensing type during summer. 2. The condensation waste heat could be obtained up to $50-55^{\circ}C$ of drying heat-source and Hot water in summer. In this case, recovered rate was about $73\%$. And the more temperature of drying Heat-source and Hot water were increased, the more a recovered rate were decreased. 3. When comparing drying characteristics of Agro-products in dryer of waste heat utilization and Hot air, there was no quality difference in products. But drying time of the former was 3 Hours longer than the latter. 4. The condensation waste heat of compressor could be applied into the drying of marine products, the predrying of agro-products and making hot water. And showed high possibility of the waste heat using in low-temperature storage.

  • PDF

한반도 상공의 응결핵 연구를 위한 기상항공기 나라호의 응결핵입자계수기 개선 및 관측 (Improvement and Observation of Condensation Particle Counter in Atmospheric Research Aircraft NARA for Condensation Particle Research in Korea)

  • 정운선;구정모;김민성;신혜민;고아름;장기호;차주완;이용희
    • 한국환경과학회지
    • /
    • 제31권9호
    • /
    • pp.803-813
    • /
    • 2022
  • In this study, we improved the water-based condensation particle counter in Atmospheric Research Aircraft NARA and investigated the condensation particle number concentration over the Korean peninsula. Pump and set point information were changed to improve the instrument used by aircraft for observation. Ground-based observational result showed that the error between two instruments, which are water-based condensation particle counter and butanol-based condensation particle counter, was 4.7%. Aerial observational result revealed that the number concentration before improvement indicate large variation with unstable condition, whereas the number concentration after improvement indicate a reasonable variation. After improvement, the number concentration was 706±499 particle/cm3 in the West Sea and 257±80 particle/cm3 in Gangwon-do, and these are similar to the concentration range reported in previous studies. Notably, this is the first attempt to use aerial observation with water-based condensation particle counter to investigate condensation particle number concentration.

테플론 코팅과 오일 담지를 이용한 알루미늄 양극산화피막의 응축 열전달 향상 (Enhancement of Condensation Heat Transfer of Anodized Aluminum by Teflon Coating and Oil-Impregnation)

  • 강민주;이종훈;차수진;신예지;김동현;김경자;이정훈
    • 한국표면공학회지
    • /
    • 제54권2호
    • /
    • pp.90-95
    • /
    • 2021
  • Surface modification technique enabling the control of condensation provides various benefit in various engineering systems, such as heat transfer, desalination, power plants, and so on. In this study, lubricant oil-impregnation into Teflon-coated nanoporous anodic oxide layer of aluminum to enhance a de-wetting and mobility of water droplet on surface. Due to the surface treatment improving water-repellency, the condensation mode is changed to dropwise, thus the frequency of sliding condensed water droplet on surface is increased. For these reasons, the surface of oil-impregnated Teflon-coated nanoporous anodic aluminum oxide shows significantly enhanced condensation heat transfer compared to bare aluminum surface. In addition, the porosity of anodic aluminum oxide affected the mobility of water droplet even with oil-impregnation and Teflon-coating, indicating that the optimization of porous structure of anodic oxide is required for maximizing the condensation heat transfer.

An Experimental Investigation of the Interfacial Condensation Heat Transfer in Steam/water Countercurrent Stratified Flow in a Horizontal Pipe

  • Chu, In-Cheol;Yu, Seon-Oh;Chun, Moon-Hyun;Kim, Byong-Sup;Kim, Yang-Seok;Kim, In-Hwan;Lee, Sang-Won
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.565-570
    • /
    • 1998
  • An interfacial condensation heat transfer phenomenon in a steam/water countercurrent stratified flow in a nearly horizontal pipe has been experimentally investigated. The present study has been focused on the measurement of the temperature and velocity distributions within the water layer. In particular, the water layer thickness used in the present work is large enough so that the turbulent mixing is limited and the thermal stratification is established. As a result, the thermal resistance of the water layer to the condensation heat transfer is increased significantly. An empirical correlation of the interfacial condensation heat transfer has been developed. The present correlation agrees with the data within $\pm$15%

  • PDF

RELAP5 Analysis of a Condensation Experiment in an Inverted U-tube

  • Park, Chul-Jin;Lee, Sang-Yong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.383-388
    • /
    • 1995
  • Two-phase transient phenomena in the noncondensable gas-filled closed loop was investigated numerically using the RELAP5/MOD3 version 3.1 computer code. The condensation heat transfer correlation for noncondensable gases was studied in detail. Two modes of the reflux condensation which can be characterized by countercurrent flow of steam and its condensed water and the oscillatory between reflux condensation and natural circulation were predicted well. However, the natural circulation mode which the condensed water carried over the U-bend concurrently with steam was failed to predict.

  • PDF

순수냉매의 흐름응축 열전달계수 (Flow Condensation Heat Transfer Coefficients of Pure Refrigerants)

  • 김신종;송길홍;정동수
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.175-183
    • /
    • 2002
  • Flow Condensation heat transfer coefficients (HTCs) of Rl2, R22, R32, Rl23, Rl25, R134a, R142b were measured experimentally on a horizontal plain tube. The experi- mental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water-glycol loop. The test section in a refrigerant loop was made of a copper tube of 8.8 mm inner diameter and 1000 mm length respectively. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. All tests were performed at a filed refrigerant saturation temperature of 4$0^{\circ}C$ with mass fluxes of 100, 200, 300 kg/$m^2$s. The experimental result showed that flow condensation HTCs increase as the quality, mass flux, and latent heat of condensation increase. At the same mass flux, the HTCs of R32 and R142b were higher than those of R22 by 35~45% and 7~14% respectively while HTCs of R134a and Rl23 were similar to those of R22. On the other hand, HTCs of Rl25 and Rl2 were lower than those of R22 by 28 ~30% and 15 ~25% respectively Finally, a new correlation for flow condensation HTCs was developed by modifying Dobson and Chato's correlation with the latent heat of condensation considered. The correlaton showed an average deviation of 13.1% for all pure fluids data indicating an excellent agreement.

엔탈피방법을 이용한 결빙 및 응축 메커니즘 해석 (Numerical Analysis of Icing and Condensation Mechanism sing Enthalpy Method)

  • 김성환;허민웅;박원규;정성해
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2901-2906
    • /
    • 2007
  • A solver for icing and condensation of water has been developed. The phase change process was solved by the enthalpy method. For the code validation, the temperature and the phase change from water to ice of the driven cavity were calculated. Also, the melting process of the frost on the windshield glass of an automobile has been simulated. The calculation showed a good agreement with analytical solution and other numerical results. Using the present validated code, the condensation of water vapor has been first tried. The computed results provided some physical features of condensation phenomena even though experimental data and other numerical data were not available. For future work, it is recommended to throughly investigate the effects of boundary conditions on the solution.

  • PDF

응축수를 이용한 이동식 에어컨의 성능특성에 관한 연구 (A Study of Performance Characteristics on Portable Air Conditioner by Using Condensation Water)

  • 김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.762-767
    • /
    • 2012
  • 본 연구는 실내외기가 일체화된 이동식 에어컨을 대상으로 장치 운전 중 발생되는 응축수를 응축기에 분사한 경우, 응축수가 장치의 성능특성에 미치는 영향을 파악한 연구이다. 연구 결과 응축기 입출구 냉매온도 및 출구 공기온도는 응축수를 이용하지 않는 기존방식에 비해 낮게 유입 및 유출되어 응축수에 의해 상당한 응축부하가 처리되는 것을 알 수 있었다. 또한 동일한 조건에서 장치의 냉동능력과 성능계수는 평균 약 3%, 13~16%정도 높게 나타났으며, 압축기 소비동력 또한 약 27%정도 낮게 나타나응축수를 이용한 경우가 주기적인 응축수 배출에 따른 문제점 해결 이외에도 장치의 성능향상에 크게 기여하는 결과를 얻을 수 있었다.

온수 보일러용 열구동 펌프에 관한 연구 (A Study on the Thermal Pump of the Hot Water Boiler)

  • 염한길;김욱중;김창주
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

Semi-Rig, Pontoon 구역 표면 결로 예방 설계 (Semi-Rig, Anti-condensation design on steel surface in pontoon area)

  • 서동재;박상언;노정환;심학무
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2017년도 특별논문집
    • /
    • pp.105-108
    • /
    • 2017
  • Condensation is one of the common issues which we can easily see in everyday life. For example, the surface of glasses with cold water is easily moisturized. This wet surface gives us uncomfortable feeling and is sometimes dangerous because it is slippery. As the safety on working space is one of the most important issue on offshore project, condensation is also important matter to take care of with precaution. Since the bottom of vessel or offshore facility is submersed in the water, the risk of having condensate on the steel surface is getting higher because sea water temperature is normally lower than ambient temperature. And if there is any electric equipment or person working in that space, condensation is normally not allowed. The pontoon of semi-submersible drilling rig is such a space which is submersed, with electric and mechanical equipments and person working periodically. To prevent condensation in pontoon, study was conducted by checking several cases.

  • PDF