• 제목/요약/키워드: Water circulation apparatus

검색결과 13건 처리시간 0.021초

초전도 HGMS를 이용한 열연 냉각수의 자기분리 연구 (Study on Magnetic Separation of Hot Roller coolant by Using Superconducting HGMS)

  • 하동우;김태형;오상수;박성국;이상길;노유미
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.37-38
    • /
    • 2007
  • It needs several large reservoirs and long time to remove suspended solid like steel fines and iron oxide in hot rolling coolant. If removing rate of suspended solid in rolling coolant is improved by using high gradient magnetic separation (HGMS) system, the productivity of working process can be increased and the area of reservoir can be reduced. Pre-treatment process that react magnetic floc with inorganic and organic flocculant in coolant was studied. Horizontal type superconducting HGMS system was manufactured successfully, which was constituted with automatic filter transportation apparatus, 6 T He-free superconducting magnet system and water circulation system. The solid suspension removal ratio in hot rolling coolant was increased by flocculation with inorganic and organic flocculant.

  • PDF

소형실험태양(小型實驗太陽)연못에서 열저장층(熱貯藏層)의 두께에 관(關)한 실험적(實驗的) 연구(硏究) (Experimental Study on Thicknesss of Heat Storage Zone in Small Solar Pond)

  • 박이동;서지원
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.22-29
    • /
    • 1987
  • This paper dealed with thickness variation of bottom heat sotrage zone due to salinity and flow rate of extration hot brine in small test solar pond (0.5m wide, 0.5m high, 1.0m long). Testing apparatus and situation were follows: 7.1 cm of height of suction diffuser and 1.8cm of height of discharge diffuser above the test pond respectively, 0.3cm of slot size of suction diffuser, 1.0cm of slot size of discharge diffuser, 47cm of length of the slot; heating of hot water ($75^{\circ}C$) through separated hot water tank, discharge of the brine into storage zone through discharge diffuser, the extration of the brine through suction diffuser, circulation of the extracted brine through a heat exchanger (cooler). Following results were obtained through the experiments. 1. In small test solar pond, the typical three zone which showed up in real solar pond were established. 2. Richardson Number was used more effectively to confirm hydrodynamic stability of the stratified flow. 3. The thickness of non convective layer had a great effect on the heat storage of the bottom convective layer, then the temperature of bottom convective layer had a relation to that of upper convective layer. 4. Optimum operating condition in the test pond was on 10%-15% of salt concentration and $0.05m^3/hr$ of flow rate of extraction hot brine. 5. Following thickness of 3 zones were available to obtain under optimum operation condition: o bottom storage zone: $30%{\pm}10%$ of total pond depth o non-convective zone: $40%{\pm}10%$ of total pond depth o Upper surface zone: $20%{\pm}10%$ of total pond depth.

  • PDF

수직 오리피스 이젝터의 혼합유동 및 산소전달 특성 (Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector)

  • 김동준;박상규;양희천
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.61-69
    • /
    • 2015
  • 본 논문은 수직 오리피스 이젝터의 혼합유동 및 산소전달 특성에 대한 실험적 연구를 목적으로 한다. 실험장치는 전동 모터-펌프, 오리피스 이젝터, 순환 수조, 공기압축기, 고속 카메라 시스템 그리고 제어 및 측정기기로 구성하였다. 측정된 구동유체 및 유입공기의 유량을 이용하여 유량비를 도출하였다. 이적터에서 분출된 혼합유동의 가시화를 통해 정성적 거동을 고찰하였으며, 용존산소 농도를 측정하여 총괄 산소전달계수를 도출하였다. 구동유체의 유량이 일정하고 압축기의 공기압이 높아지면 유량비와 산소전달계수는 증가하며, 압축기의 공기압이 일정하고 구동유체의 유량이 증가하면 유량비는 감소하지만 산소전달계수는 증가하였다. 기포의 크기에 따른 체류시간 및 확산도와 수직 혼합유동의 도달거리는 2 상의 접촉면적과 시간에 크게 영향을 미치기 때문에 산소전달율의 중요한 변수임을 유추할 수 있다.