• 제목/요약/키워드: Water chiller

검색결과 120건 처리시간 0.025초

태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션 (Dynamic simulation of a solar absorption cooling system)

  • 정시영;조광운
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

하천수 이용 열원시스템의 경제성 평가 (Economic Evaluation on Energy System Using River Water)

  • 이철구;김종대;임태순;최명식;방승기;함흥돈
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권2호
    • /
    • pp.25-31
    • /
    • 2013
  • It has become very important for unused energy to be used for building air conditioning. Economic evaluation on energy system by using river water as a heat source, which is one of the unused energy, was carried out. The floor area of the building and the distance between heat source equipment and river was assumed $50,000m^2$ and 200 m. General heat source system using absorption chiller-heater was used for comparing to the energy saving system, and payback period method using initial cost and running cost of two systems, was used to perform economic evaluation. According to development of high capacity of water source heat pump which is appropriate for using river water, initial cost for the system has been reduced. Payback period was about 3.2 years, and this period might be shortened if nation's economic support enact.

유문암-열수 반응과 유광 견운모 광상의 성인 (Hydrothermal Solution-Rhyolite Reaction and Origin of Sericitite in the Yukwang Mine)

  • 박맹언;최인식;김진섭
    • 자원환경지질
    • /
    • 제25권3호
    • /
    • pp.225-232
    • /
    • 1992
  • The hydrothermal alteration is evaluated using multicomponent equilibrium calculations with the program CHILLER for the reactions between hydrothermal water and rhyolite at the temperature of $300^{\circ}C$ and pressure of 500 bars. The chemical-reaction model on the depositional processes of the sericitite confirms that the hydrothermal water-rock interaction(hydrothermal alteration) is the main mechanism of the sericitite formation. The principal change in the aqueous phase during the reaction is the pH increase. Overall trends for the major species are the increase in total molalities of K, Ca, $SiO_2$, Al, Mg, Fe, Na, and sulfide in solid phase with hydrothermal water-rhyolite reaction and the decrease of them in aqeous solution by precipitation of hydrothermal products. Quartz and sericite are the first minerals to form. The sequence of minerals to precipitate following them is chlorite, epidote, pyrite and microcline as water/rock ratio decreases. Although calculated results cannot duplicate the complexities of natural hydrothermal alteration, the calculation provides thermodynamic constraints on the natural process. The calculation results resemble those of experimental studies. Sericitite forms where pH decreases and water/rock ratio increases.

  • PDF

태양열 흡수식 냉방 시스템의 동특성 연구 (A Study on the Dynamic Performance of a Solar Absorption Cooling System)

  • 백남춘;이진국;양윤섭;정시영
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.81-87
    • /
    • 1998
  • Solar energy has been experiencing renewed interest because of the recent economical crisis in Korea. Absorption cooling is one of the promising solar energy utilization technologies. In this study the dynamic performance of a solar driven absorption cooling machine(SDACM) was numerically investigated. The simulated machine is a commercially available water/LiBr single effect absorption chillers driven by hot water from solar collectors. The present study has been directed to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collector, a hot water storage tank, fan coil units, and the air-conditioned space. The operation of the system was simulated for 9 hours in varying operation conditions. The variation of temperature and concentration in the system components, and that of heat transfer rates in the system were obtained. It was also found that the room temperature was maintained near the desired value by controlling the mass flow rate of hot water.

  • PDF

Effects of a Dietary Chitosan-Alginate-Fe(II) Complex on Meat Quality of Pig Longissimus Muscle during Ageing

  • Park, B.Y.;Kim, J.H.;Cho, S.H.;Hwang, I.H.;Jung, O.S.;Kim, Y.K.;Lee, J.M.;Yun, S.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권3호
    • /
    • pp.414-419
    • /
    • 2005
  • The current study was conducted to investigate the effects of dietary chitosan-alginate-Fe(II) complex (CAFC) supplementation on carcass and meat qualities of pig m. longissimus during chiller ageing. One hundred and twenty-two LYD (Landrace${\times}$Yorkshire${\times}$Duroc) pigs were sampled from an industrial population. Seventy-four pigs (32 gilts and 42 barrows) were administered 3 ml of dietary supplementation of CAFC per day from 25 to 70 days of age, while the remaining 48 pigs (20 gilts and 28 barrows) were fed the same commercial feeding regime without the supplementation. For assessing the dietary effects on pH, objective meat color, cooking loss, water-holding capacity (WHC), thiobarbituric acid reactive substances (TBARS), volatile basic nitrogen (VBN) and fatty acid composition during ageing, 20 barrows (10 of each treatment) were randomly sampled, and aged for 3, 7, 12, 16, 20 and 25 days in a $1^{\circ}C$ chiller. The results showed that CAFC-fed pigs required approximately 10 fewer feeding days than the control group. Furthermore, the treatment resulted in greatly higher carcass grade whereby the grade A was increased by approximately 35% and 7% for gilts and barrows, respectively. The treatment had no significant effect (p>0.05) on pH, meat color and WHC during ageing. On the other hand, the CAFC-fed pigs showed significantly (p<0.05) lower TBARS values from 20 days of storage. In addition, the sum of unsaturated fatty acids for the treated group was significantly (p<0.05) higher than that for the control group after the storage time. This implied that CAFC supplementation could reduce the formation of free radicals in fatty acids (i.e., lipid oxidation). The treatment also significantly (p<0.05) retarded VBN formation during ageing, indicating a significant reduction in protein degradation. However, as there was no difference in pH between the two groups, the result raised a possibility that antibacterial activity of the CAFC alone could cause reduction in the formation of TBARS and VBN. In this regard, although the treatment effectively slowed down the formation of TBARS and TBA during chiller ageing, it was not resolved whether that was associated with the direct effect of the antioxidant function of chitosan and/or alginate, or a consequence of their antibacterial functions.

흡착식 냉동기의 열 및 물질전달에 관한 실험적 연구 (An Experimental Study on the Heat and Mass Transfer of Adsorption Chiller)

  • 권오경;윤재호;주영주;김용찬;김종하
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.746-753
    • /
    • 2005
  • Adsorption chillers have been receiving considerable attentions as they are energy-saving and environmentally benign systems. In order to evaluate adsorption rates, experiments were performed in the batch type adsorption apparatus. Three types of silica gels were investigated under an assortment of experimental conditions that are representatives of the actual operating environments in the adsorber of adsorption chillers. Experimental results revealed the effects of silica gel particle size, bed temperature, and fin pitch of fin tube on the adsorption rate. The $0.25\~1.18mm$ particle size of silica gel with high adsorption rate was selected as a suitable adsorbent. The measured adsorption rate became bigger with decreasing particle size. From the comparison of adsorption rate, it is found that the fin tube has about $21\%$ higher value than that of the bare tube. The effect of heat and mass flux is found to be more significant in the fin tube than in the bare tube.

하수처리수 이용 열원시스템의 경제성 평가 (Economic Evaluation on Energy System Using Treated Sewage Water)

  • 이철구
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권3호
    • /
    • pp.16-22
    • /
    • 2017
  • It has become important for unutilized energy to be used for air conditioning of building. Economic evaluation on energy system by using treated sewage water as heat source, which is one of unutilized energy, was performed. The floor area of the subject building and the distance between heat source equipment and sewage treatment plant was assumed $30,000m^2$ and 200m. Absorption chiller-heater system was used for comparing to the energy efficient system, and payback period method was applied to carry out economic evaluation. Although the operating cost of this system is reduced compared to general heat source system, the ratio is not meaningful compared to the initial investment cost increase, and payback period was calculated to be about 36.1 years. However, when calculated based on the 2014 rate of electricity and city gas, it will be greatly reduced to 3.1 years. International commodity prices are constantly changing, and therefore national policy on the spread of unutilized energy should be maintained.

도계장 유래 닭고기와 부산물 및 환경재료에서 Listeria spp의 분리 및 분리균의 특성 I. Listeria spp의 분리 (Characteristics and isolation of Listeria spp from poultry meat, products and environmental specimens in chicken slaughterhouse I. Isolation of Listeria spp)

  • 손원근;강호조
    • 대한수의학회지
    • /
    • 제31권3호
    • /
    • pp.271-277
    • /
    • 1991
  • To investigate the epidemiological trait of listeriosis, Listeria spp were isolated from poultry meat, products and environmental specimens in chicken slaughterhouse. Also determined were isolation rates by the different enrichment procedures, the biochemical properties of isolates. In a total of 307 samples including poultry meat, liver, feathers, feces, chiller water, scalding water overflow and slaughterhouse floor, Listeria spp were isolated predominantly from scalding water overflow (90.0%), body skin before washing (66.7%), liver (20.0%) and feathers(15.0%) However, few Listeria spp were isolated from body skin after washing and feces. The higher isolation rates were obtained in the secondary enrichment procedure (7.2%) than in the primary enrichment (3.9%); after stored the secondary enrichment cultures for 2 weeks at $4^{\circ}C$, Listeria spp were present in 9.8%. The majority of the isolated Listeria spp were identical to those of the standards strains in biochemical and cultural properties. Overall, Listeria spp were present in 13.4% of the specimens tested, and were in order of prevalence of L innocua(11.1%), L monocytogenes(3.3%), L grayi(0.7%) and L murrayi(0.3%).

  • PDF

숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구 (Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building)

  • 최영돈;한성호;조성환;김두성;엄철준
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, such as ground source, river water, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large resident building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing of sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교 (Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle)

  • 정시영;이상수;조광운;백남춘
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF