• Title/Summary/Keyword: Water charge

Search Result 656, Processing Time 0.03 seconds

Experimental Study on the Heating Performance of a Variable Speed CO2 Heat Pump with a Variation of Operating Conditions (가변속 이산화탄소 열펌프의 난방성능 특성에 관한 실험적 연구)

  • Cho, Hong-Hyun;Lee, Ho-Sung;Jang, Yong-Hee;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.8
    • /
    • pp.694-701
    • /
    • 2007
  • The applications of a transcritical $CO_2$ cycle into water heaters show advantages over conventional systems in the respect of power consumption and heating efficiency because the $CO_2$ cycle has a high compressor discharge temperature. Besides, the heating performance of the transcritical $CO_2$ cycle can be improved by optimizing operating conditions. In this study, the heating performance of a variable speed $CO_2$ heat pump was measured and analyzed by varying refrigerant charge amount, EEV opening, compressor frequency and outdoor temperature. As a result, the optimum normalized charge for heating was 0.226. The COPs at the compressor frequencies of 40, 50 and 60 Hz were 2.94, 2.75 and 2.25, respectively. The heating performance of the $CO_2$ cycle with charge amount was more sensitive than the cooling performance. Moreover, the heating performance was improved significantly by optimizing of compressor frequency and EEV opening.

Hydrophilic and Hydrophobic Group Characteristics for Nonionic Surfactants (비이온 계면활성제에 대한 친수성기와 소수성기의 그룹 특성)

  • Ha, Youn-Shick;Son, Man-Shick;Paek, U-Hyon
    • Journal of Environmental Science International
    • /
    • v.3 no.1
    • /
    • pp.57-64
    • /
    • 1994
  • On the basis of the principle of Bratch's electronegativity equalization, we calculated group partial charges and group electronegativities for nonionic surfactants with Pauling's elecoonegativity parameters by using numerical calculation method. From calculated outputs we have investigated structural stability of micelle, characteristics of hydrophilic and hydrophobic groups, and relation between CMC(Critical Micelle Concentraion) and group partial charge and group electronegativity of hydrophilic and hydrophobic groups for nonionic surfactants. We have known that CMC by micelle formation depends upon group partial charge and group electronegativity of hydrophilic and hydrophobic groups for surfactants. Also, the structural stability of micelle in H2O solution is related to the electric double layer by the hydrophilic group of nonionic surfactants with H atoms in water CMC is diminished by the decrease of repeating units in hydrophilic group at constant hydrophobic group and is diminished by the increments of alkyl chains in hydrophobic group at constant hydrophilic group for nonionic surfactants. In conclusion, CMC is diminished because there is no electrostatic repulsion and is diminished of Debye length by the increments of partial charge of hydrophobic group.

  • PDF

Surface Properties and interfacial Potential Distribution of Surface Treated-Alumina (표면처리한 알루미나의 표면물성과 계면전위분포)

  • 홍영호;함영민
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.7
    • /
    • pp.823-831
    • /
    • 1996
  • Due to the intrinsic low surface activation of ${\gamma}$-alumina it has been used limitely in practice. Accordingly forward enhancing its utility ${\gamma}$-alumina surface was treated with slfuricf aicd nitric acid and chloric acid respec-tively. Subsequently the effects of surface activity on the surface electrical characteristics were investigated. The ${\gamma}$-alumina was prepared by the precipitation of aluminium nitrate [Al(NO3)3.9H2O] using ammonia water as a precipitator and it was chemically treated with such acids mentioned above. The surface and morphology of the acid-treated ${\gamma}$-alumina were analysed by XRD, BET and the surface activities were measured by the amine titration methods. The interfacial properties of the ${\gamma}$-alumina dispersed in electrolyte solution were esti-mated by the surface charge density measured using potentiometric tiration. Based on the relation between surface charge density and the acid amount the following results were drawn for the surface and interfacial electrical properties ; Acidic properties of surface-treated alumina increase with anion load on alumina surface. P. Z. C decreases with acid amount on alumina surface. The surface charge densities were apart from electrolyte ionic strength. The acidity of ${\gamma}$-alumina is linearly dependent on the P. Z,.C when the ${\gamma}$-alumina was dispersed in aqueous electrolyte solution.

  • PDF

Space Charge Measurement of Low Density Polyethylene Film due to Morphological Change (고차구조 변화에 따른 저밀도 폴리에틸렌의 공간전하 측정)

  • Go, Si-Hyeon;Kim, Seong-Pil;Shin, Jong-Yeol;Lee, Su-Won;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.41-45
    • /
    • 2000
  • As LDPE, widely used as a insulating material of power cable, has defects of treeing and space charge accumulation, various methods to improve them have been suggested. It is difficult to understand the mechanism of electrical conduction according to the complexity of molecular structure and the changes of super-structure due to various environmental parameters. Therfore in this paper, four kinds of heat-treated LDPEs(origin, slow cooled, water cooled, quenched in $LN_2$) were used as specimens to help us understand the mechanisms and space charge distributions were investigated at 60[min] just after applying the field of 1[MV/cm] and 10[min] just after short-circuiting, using LIPP method.

  • PDF

EFFECT OF MIXTURE PREPARATION IN A DIESEL HCCI ENGINE USING EARLY IN-CYLINDER INJECTION DURING THE SUCTION STROKE

  • Nathan, S. Swami;Mallikarjuna, J.M.;Ramesh, A.
    • International Journal of Automotive Technology
    • /
    • v.8 no.5
    • /
    • pp.543-553
    • /
    • 2007
  • It is becoming increasingly difficult for engines using conventional fuels and combustion techniques to meet stringent emission norms. The homogeneous charge compression ignition(HCCI) concept is being evaluated on account of its potential to control both smoke and NOx emissions. However, HCCI engines face problems of combustion control. In this work, a single cylinder water-cooled diesel engine was operated in the HCCI mode. Diesel was injected during the suction stroke($0^{\circ}$ to $20^{\circ}$ degrees aTDC) using a special injection system in order to prepare a nearly homogeneous charge. The engine was able to develop a BMEP(brake mean effective pressure) in the range of 2.15 to 4.32 bar. Extremely low levels of NOx emissions were observed. Though the engine operation was steady, poor brake thermal efficiency(30% lower) and high HC, CO and smoke were problems. The heat release showed two distinct portions: cool flame followed by the main heat release. The low heat release rates were found to result in poor brake thermal efficiency at light loads. At high brake power outputs, improper combustion phasing was the problem. Fuel deposited on the walls was responsible for increased HC and smoke emissions. On the whole, proper combustion phasing and a need for a well- matched injection system were identified as the important needs.

Effects of Polyelectrolytes on the Charge Transfer Complexing between Indole derivatives and Methylviologen: Hydrophobic and Electrostatic Interactions

  • Park, Joon-Woo;Hwang, Book-Kee
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.3
    • /
    • pp.145-148
    • /
    • 1985
  • The effect of anionic polyelectrolytes, poly(styrenesulfonate) (PSS) and poly(vinylsulfonate) (PVS), on the charge transfer complexing between indole derivatives and methyl viologen($MV^{++}$) cation was investigated. The results were compared with effect of NaCl and an anionic surfactant, sodium dodecylsulfate (SDS). Both PSS and PVS enhanced the complex formation of neutral species (indole and indole acetate at low pH), zwitter ionic tryptophan, and positively charged tryptamine and tryptophan at low pH with $MV^{++}$. This result was attributed to the contribution of hydrophobic interaction, in addition to electrostatic interaction. The enhancing effect of PSS was much higher than that of PVS reflecting the higher hydrophobicity of PSS. The interaction between indole acetate anion and $MV^{++}$ was greatly reduced by addition of PVS and PSS. The higher charge density of PVS was appeared as greater reducing effect indicating the importance of electrostatic force in this case. In all cases, the effect of polyelectrolytes showed maxima, and further addition of PVS and PSS decreased the effect. This behavior was explained in terms of distribution of indole derivatives and $MV^{++}$ in domain of polyanions. The complex formation constants and molar absorptivities of complexes were determined, and the values were compared with those in water and SDS solutions.

Estimation of Water Content in Leaf Litter of Three Quercus Species by Reflectance Water Index (Reflectance water index를 이용한 참나무속 3종 낙엽의 함수량 추정)

  • Suh, Kyehong
    • Journal of Environmental Science International
    • /
    • v.27 no.4
    • /
    • pp.275-279
    • /
    • 2018
  • Water status of intact plants has been optically estimated by measuring reflectance at the wavelengths 1,450 nm and 1,900 nm based on their signal strengths. Although another water band at 970 nm is considered to have very small signals, the band apparently lies within the detection range of inexpensive spectrometer and plain charge-coupled device (CCD) camera used in wild fire studies. However measurement of the reflectance at 970 nm has been rarely applied to estimate the water status of dead plant materials such as fallen branch, twig, and leaf. To test the possibility of applying water reflectance at 970 nm to estimate the water content (WC) in leaf litter, the reflectance in various WC values were measured in the leaf litter of three Quercus species (Q aliena, Q aliena, Q mongolica, and Quercus variabilis). The results showed that the WC in the leaf litter can be determined by reflectance water index (WI) in the three Quercus species ($WC=1,450{\times}WI-1,378.8$, r=0.865). However, there was no interaction effect in the relationship between WI and WC among the litter of the three Quercus species.

Boron removal from model water by RO and NF membranes characterized using S-K model

  • Kheriji, Jamel;Tabassi, Dorra;Bejaoui, Imen;Hamrouni, Bechir
    • Membrane and Water Treatment
    • /
    • v.7 no.3
    • /
    • pp.193-207
    • /
    • 2016
  • Boron is one of the most problematic inorganic pollutants and is difficult to remove in water. Strict standards have been imposed for boron content in water because of their high toxicity at high concentrations. Technologies using membrane processes such as reverse osmosis (RO) and nanofiltration (NF) have increasingly been employed in many industrial sectors. In this work, removal of boron from model water solutions was investigated using polyamide reverse osmosis and nanofiltration membranes. RO-AG, RO-SG, NF-90 and NF-HL membranes were used to reduce the boron from model water at different operational conditions. To understand the boron separation properties a characterization of the four membranes was performed by determining the pure water permeability, surface charge and molecular weight cut-off. Thereafter, the effect of feed pressure, concentration, ionic strength, nature of ions in solution and pH on the rejection of boron were studied. The rejection of boron can reach up to 90% for the three membranes AG, SG and NF-90 at pH = 11. The Spiegler-Kedem model was applied to experimental results to determine the reflection coefficient of the membrane ${\sigma}$ and the solute permeability $P_s$.

Techniques of Water Quality Improvement by Using Ozone Generation System (오존발생시스템을 이용한 하천수질 개선기법)

  • Kim, Min-Young;Ryu, Jae-Wook;Lee, Seung-Yun;Jee, Hong-Kee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2122-2126
    • /
    • 2008
  • With the degradation of water quality and, at the same time increased water usage, the sources of high quality, for examples, river/stream, municipal reservoir, wells, artisan and surface water, are diminishing. Therefore, the importance of water quality has been emphasized over the years through publications and various literature sources. Even though considerable research has resulted in significant strides for providing interpretive information and mitigation strategies for improvement of waters, the quality of which is still questionable. This study aims to propose a completely independent self-contained system for purifying waters, solar-powered ozone generator. It is a semi-permanent and cost effective environmental solution. Functions of ozone treatment are: 1) to maintain oxidative flexibility, 2) remove harmful chemicals, wastes, and other substances, and 3) prevent epizootic microbial outbreaks. Recent advances in technology have allowed the development of the practical, self-contained and independent solar powered device. Solar electrical producing panels that charge batteries are the key to using these systems anywhere electrical power is not available. This paper invites the readers to examine the problem and consider the viable, proven solution the solar powered ozone purifying system. This paper also introduces basic concept and background of solar powered ozone generators and examine its feasibility for improving water quality in rivers and streams.

  • PDF

A Study on the Charge of Water Quality in the Vicinity of Mokpo Harbor due to the Discharges from Yongsan River Estuary Weir and Yongam-Kumho Sea Dike (영산강 하구둑과 영얌-금호방조제 방류에 의한 목포항 주변 수역의 수질변화에 관한 연구)

  • 정대득;이중우;국승기
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.253-261
    • /
    • 1999
  • It is essential for port planning, coastal zone management and environmental impact study to analyze the variation of current and water quality due to the development of water area and discharged water from the estuary barrage and basin, etc. Mokpo sea area has downstream from a long river and two large basins, the Yongsan river and Yongam-Kumho basins, discharging much of water through water gates for the purpose of flood and prohibition of salt intrusion to the inland fresh water area. In this study, the numerical calculation were carried out for the analysis of diffusion characteristics due to discharging operation, adopting the results of tidal current simulation. ADI method is applied to the governing equation for the movement of sea water and diffusion and 6-point method to the advection terms of diffusion equation. As the results of this study, it is known that the discharging operation causes increasing and/or decreasing of current velocity and enlarging and/or depressing of pollutant diffusion limits depending on the distance from the discharging gates and the modes of discharging operation. To utilize these result, the linked gate operation and the method increasing exchange of sea water must be considered.