• 제목/요약/키워드: Water charge

검색결과 655건 처리시간 0.029초

용량 가변 및 유량변화에 따른 지열원 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성 (Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Type Ground Source Heat Pump with a Variation of Compressor Speed and Water Flow Rate)

  • 조찬용;최종민
    • 신재생에너지
    • /
    • 제7권4호
    • /
    • pp.30-36
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWTs of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system was optimized at higher refrigerant charge amount conditions.

압축기 용량 및 유량변화에 따른 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성 (Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Heat Pump with a Variation of Compressor Speed and Water Flow Rate)

  • 조찬용;최종민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.143.1-143.1
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz, and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWT of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system optimized at higher refrigerant charge amount conditions.

  • PDF

폴리이미드 박막의 공간전하현상 및 수분의 영향 (Space Charge Phenomena in Polyimide Films and Effects of Absorbed Water)

  • 윤주호;최용성;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.82-85
    • /
    • 2008
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

폴리이미드 박막의 공간전하현상 (Space Charge Phenomena in Polyimide Films)

  • 윤주호;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.311-312
    • /
    • 2007
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

PCB 절연체에서 전하 형성과 수분 흡수 (Water Absorption and Charge Formation in PCB)

  • 이정수;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.233-234
    • /
    • 2008
  • We observed internal space charge behavior for two types of epoxy composites under dc electric fields to investigate the influence of water at high temperature. In the case of glass/epoxy specimen, homocharge is observed at water-treated specimen, and spatial oscillations become clearer in the water-treated specimens. Electric field in the vicinity of the electrodes shows the injection of homocharge. In aramid/epoxy specimens, heterocharge is observed at water-treated specimens, i.e. negative charge accumulates near the anode, while positive charge accumulates near the cathode. Electric field is enhanced just before each electrode. In order to further examine the mechanism of space charge formation, we have developed a new system that allows in situ space charge observation during ion migration tests at high temperature and high humidity. Using this in situ system.

  • PDF

PCB 절연체에서 전하 형성과 수분 흡수의 영향 (Influence of Water Absorption and Charge Formation in PCB)

  • 구정현;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2307-2308
    • /
    • 2008
  • We observed internal space charge behavior for two types of epoxy composites under dc electric fields to investigate the influence of water at high temperature. In the case of glass/epoxy specimen, homocharge is observed at water-treated specimen, and spatial oscillations become clearer in the water-treated specimens. Electric field in the vicinity of the electrodes shows the injection of homocharge. In aramid/epoxy specimens, heterocharge is observed at water-treated specimens, i.e. negative charge accumulates near the anode, while positive charge accumulates near the cathode. Electric field is enhanced just before each electrode. In order to further examine the mechanism of space charge formation, we have developed a new system that allows in situ space charge observation during ion migration tests at high temperature and high humidity. Using this in situ system.

  • PDF

낙동강 하류 원수의 응집제 주입 자동화를 위한 Streaming Current Detector (SCD)와 Charge Analyzing System (CAS)의 평가 (Evaluation of Streaming Current Detector (SCD) and Charge Analyzing System (CAS) for automation of coagulant dosage determination)

  • 김상구;손희종;이정규;염훈식;유평종
    • 대한환경공학회지
    • /
    • 제39권4호
    • /
    • pp.201-207
    • /
    • 2017
  • 본 연구에서는 낙동강 하류원수에 대한 응집제 주입율 자동화를 위해 stream current detector (SCD)와 charge analyzing system (CAS)의 적용성 비교 평가하였다. SCD 시스템을 이용한 경우, 원수 pH가 9.3에서 5.7로 낮아지면 pH 9.3에서 설정된 유동 전하값을 응집제 주입율로 사용할 수 없었고, pH 5.7에 맞는 유동 전하값의 재설정이 필요하였다. 원수의 pH 변화에 따른 SCD의 유동 전하값의 재설정을 하지 않을 경우, 후단의 모래여과 처리수 탁도가 증가하는 현상을 보였다. CAS 시스템의 경우는 원수 pH의 범위가 6.0~9.3의 범위일 때 polydadmac을 전하 중화제로 사용하는 것이 가능하였고, 고탁도 원수에도 poly-dadmac이 양호한 전하중화제로 평가되었다. 그러나 pH 5~11의 범위에서 polydadmac의 전하량은 거의 변화하지 않은 반면, 응집제로 사용되는 alum의 전하량은 6배 정도 차이가 발생하고, pH에 적합한 응집제 요구량을 보였다. 따라서 원수의 pH가 높은 경우는 전하 적정제로 정수장에서 사용하는 응집제를 직접 이용하는 것이 효율적이었다.

폴리이미드 박막의 공간전하현상에 관한 연구 동향 (A Research Trend on High Density Polyethylene Electrical Strength)

  • 최근호;오창근;신현만;황종선;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1984-1985
    • /
    • 2007
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

수질배출부과금제도 개선 방안 연구 (The Effect of Industrial Waste Water Effluent Charge Reform)

  • 민동기
    • 자원ㆍ환경경제연구
    • /
    • 제18권4호
    • /
    • pp.767-785
    • /
    • 2009
  • 본 연구에서는 수질배출부과금제도의 부과체계를 분석하고 개선 방안을 연구하였다. 수질배출부과금제도는 환경오염 원인자에게 처리비용을 부담시켜 환경자원을 효율적으로 사용하도록 하는 경제적 유인 목적을 가지고 있으나 현행 수질배출부과금제도는 행정 규제적 성격이 강하다. 즉, 배출허용기준을 설정하여 이를 위반한 배출업소에 대하여 사업장 규모, 지역, 위반 횟수, 오염물질별 초과율을 고려한 누증적 부과계수를 적용하여 실제 환경오염 비용을 훨씬 초과하는 형벌적 성격의 부과금을 부과하고 있다. 그러나 과도한 부과금 부과로 배출부과금 징수율은 환경관련 부과금 중 가장 낮은 수준이다. 따라서 본 연구에서는 규제적 성격의 부과체계를 개편하여 경제적 유인제도로 수질배출부과금제도를 개편하는 부과체계 개편안을 연구하였으며 이에 따른 부과액 및 징수액 변화 효과를 추정하였다. 추정 결과를 보면 현행 부과금 부과액은 오염물질 처리단가의 약 4배 이상을 부과하고 있어 환경자원의 비효율적 배분을 초래하고 있음을 보여준다. 아울러 과도한 부과금 부과체계를 개선하는 경우에는 징수율도 제고되어 수질배출부과금제도의 기능을 회복할 수 있음을 보여준다.

  • PDF

Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable

  • Ebinuma, Yasumitsu;Masui, Noriaki
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.224-229
    • /
    • 2006
  • Many studies have been done on the application of residual charge measurement in cable degradation diagnosis. In this paper, the behavior of residual charges measured with water-tree degraded XLPE sheets and cable are discussed. At charge injection process, the charge is injected by applying dc voltage as a conventional method, suddenly cut-off ac voltage or impulse voltage. Therefore the residual charge is influenced by the applying process. At charge release process, transient dc current flows when applying ac high voltage and also ac high voltage superimposed to dc low voltage. From the results, new diagnosis method is suggested.