• Title/Summary/Keyword: Water and heat degradation

Search Result 66, Processing Time 0.022 seconds

WATER ACTIVITY AND PIGMENT DEGRADATION IN DRIED LAVERS STORED AT ROOM TEMPERATURE (건해태(김) 저장시의 수분활성과 색소분해반응)

  • LEE Kang-Ho;CHOI Ho-Yeon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.6 no.1_2
    • /
    • pp.27-36
    • /
    • 1973
  • The effect of water activity on degradation of pigments in dried lavers, Porphyra tenera Kjellm. was examined when stored at room temperature for fifty days. Chlorophyll pigment was extracted with methanol-petroleum ether mixture solvent(2:1 v/v), partitioned in ether, and analysed spectrophotometrically at 662 nm as chlorophyll a. The degradation products of chlorophyll were isolated on sugar-starch column(85:15 w/w) with n-propanol-petroleum ether solution(1:200 v/v) as a developing solvent. The isolated green colored zones were analysed individually at the wavelengths of 650, 662, and 667 nm as allomerized product, chlorophyll a retained, and pheophytin formed respectively. Carotenoida were also extracted with the methanol mixture solvent, partitioned in ether, and finally redissolved in acetone after the evaporation of ether in a rotary vacuum evaporator. The total carotenoid content was measured as lutein at 450 nm. From the results, it is noted that the rate of chlorophyll degradation reached a minimum at 0.11 to 0.33 water activity while progressively increased at higher moisture levels resulting in rapid conversion of chlorophyll to pheophytin. At lower activity, autocatalysed oxidizing reaction like allomerization seemed prevailing the acid catalysed conversion reaction. The loss of carotenoid pigment was also greatly reduced at the range of 0.22 to 0.34 water activity with much faster oxidative degradation at both higher and extremely lower moisture levels. These two moisture levels indicated above at which the both pigments exhibited maximum stability are considerably higher than the BET monolayer moisture which appeared 7.91 percent on dry basis at Aw=0.10 calculated from the adsorption isothermal data of the sample at $20^{\circ}C$. The rate of pigment loss in heat treated samples at 60 and $100^{\circ}C$ for 2 hours prior to storage somewhat decreased, particularly at higher moisture levels although the final pigment retention was not much stabilized.

  • PDF

Protease Inhibitors in Porcine Colostrum: Potency Assessment and Initial Characterization

  • Zhou, Q.;He, R.G.;Li, X.;Liao, S.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.12
    • /
    • pp.1822-1829
    • /
    • 2003
  • Porcine colostrum and milk were separated into the acid-soluble and casein fractions by acidification followed by centrifuge. The acid-soluble fraction of porcine colostrum was further separated by liquid chromatography and anisotropic membrane filtration. Trypsin and chymotrypsin inhibitory capacity in porcine colostrum, milk and their components was determined by incubating bovine trypsin or chymotrypsin in a medium containing their corresponding substrates with or without addition of various amounts of porcine colostrum, porcine milk or their components. The inhibition of insulin-like growth factor I (IGF-I) and epidermal growth factor (EGF) degradation in pig small intestinal contents by porcine colostrum was measured by incubating iodinated IGF-I or EGF with the intestinal contents with or without addition of porcine colostrum. Degradation of labeled IGF-I or EGF was determined by monitoring the generation of radioactivity soluble in 30% trichloroacetic acid (TCA). The results showed that porcine colostrum had high levels of trypsin and chymotrypsin inhibitory activity and increased the stability of IGF-I and EGF in pig intestinal contents. The inhibitory activity declined rapidly during lactation. It was also found that trypsin and chymotrypsin inhibitory activity and the inhibition on IGF-I and EGF degradation in the acid-soluble fraction were higher than that in the casein fraction. Heat-resistance study indicated that trypsin inhibitors in porcine colostrum survived heat treatments of $100^{\circ}C$ water bath for up to 10 min, but exposure to boiling water bath for 30 min significantly decreased the inhibitory activity. Compared with the trypsin inhibitors, the chymotrypsin inhibitors were more heatsensitive. Separation of the acid-soluble fraction of porcine colostrum by liquid chromatography and anisotropic membrane filtration revealed that the trypsin and chymotrypsin inhibitory capacity was mainly due to a group of small proteins with molecular weight of 10,000-50,000. In conclusion, the present study confirmed the existence of high levels of protease inhibitors in porcine colostrum, and the inhibition of porcine colostrum on degradation of milk-borne growth factors in the pig small intestinal tract was demonstrated for the first time.

Effects of Non-absorbable Gases in the Absorption of Water Vapor by Aqueous LiBr Solution Film on Horizontal Tube Banks

  • Kwon, Ky-Seok;Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.19-27
    • /
    • 2001
  • In the present study, the effects of film Reynolds number (60∼200) and volumetric content of non-absorbable gases (0∼10%) in water vapor on the absorption process of aqueous LiBr solution were investigated experimentally. The formation of solution film on the horizontal tubes of six rows was observed to be complete for Re>100. Transition film Reynolds number was found to exist above which the Nusselt number and Schmidt number diminishes with solution flow rate. As the concentration of non-absorbable gases increased, mass transfer rate decreased more seriously than heat transfer rate did. the degradation effects of non-absorbable gases seemed to be significant especially when small amount of non-absorbable gases was introduced to the pure water vapor.

  • PDF

Analysis of the Influence of Anti-icing System on the Performance of Combined Cycle Power Plants (가스터빈 결빙방지 시스템이 복합화력발전 시스템의 성능에 미치는 영향)

  • Moon, Seong Won;Kim, Jeong Ho;Kim, Tong Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.19-25
    • /
    • 2016
  • Anti-icing is important in gas turbines because ice formation on compressor inlet components, especially inlet guide vane, can cause performance degradation and mechanical damages. In general, the compressor bleeding anti-icing system that supplies hot air extracted from the compressor discharge to the engine intake has been used. However, this scheme causes considerable performance drop of gas turbines. A new method is proposed in this study for the anti-icing in combined cycle power plants(CCPP). It is a heat exchange heating method, which utilizes heat sources from the heat recovery steam generator(HRSG). We selected several options for the heat sources such as steam, hot water and exhaust gas. Performance reductions of the CCPP by the various options as well as the usual compressor bleeding method were comparatively analyzed. The results show that the heat exchange heating system would cause a lower performance decrease than the compressor bleeding anti-icing system. Especially, the option of using low pressure hot water is expected to provide the lowest performance reduction.

An Influence of Unit-Water Content Distribution in Ready-Mixed Concrete on Strength and Durability of Concrete (레미콘 단위수량 산포가 콘크리트 강도 및 내구성에 미치는 영향)

  • Woo, Young-Je;Lee, Han-Seung;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.375-381
    • /
    • 2008
  • Various problems such as durability degradation may happen when extra water is added to concrete. Because of these reasons, the change of water content is managed by using rapid evaluation method of unit water content such as electric capacity method, heat drying method making use of micro wave, unit capacity mass method among various methods. Especially, in Japan, guidance for the change of water content ($\pm$ 10, 15, 20 kg/$m^3$ etc.) were regulated and used. However, it is the real situation that the guidance which were regulated in South Korea evaluate suitability only considering production and measurement error under the circumstances which are not considering the degree of durability degradation. Therefore, this study tries to investigate the influence of addition of extra water in the concrete on the durability degradation of concrete when it was added by artificial manipulation or by management error. From the test results, a guideline of the contents of extra water for the quality control is suggested with the consideration of the degree of durability degradation and the probable error resulted from the addition of extra water. The contents of extra water for tests are set as 0, 15, 25, 35 kg/$m^3$. To examine the durability degradation of concrete, freezing and thawing, carbonation, chloride penetration and compressive strength are tested.

Heat Liberation in the Reaction of $YBa_2Cu_3O_{7-}\delta$, $Y_2BaCuO_5$, and Binary Compounds in the Ba-Cu-O System with Water ($YBa_2Cu_3O_{7-}\delta$, $Y_2BaCuO_5$ 및 Ba-Cu-O계 화합물의 수분과의 반응에 의한 열방출에 관한 연구)

  • 김배연
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.1
    • /
    • pp.83-89
    • /
    • 1995
  • YBa2Cu3O7-$\delta$, Y2BaCuO5, and binary compounds in the Ba-Cu-O system with the nominal composition of Ba2CuO3, BaCuO2, Ba3Cu4O7, Ba3Cu5O8 were synthesized to investigate the heat evolutions and crystalline phases in the hydration reaction of orthorhombic YBa2Cu3O7-$\delta$ phase. The observed crystalline phases were YBa2Cu3O7-$\delta$, Y2BaCuO5, and BaCuO2, or Ba2Cu3O5+x, and some amount of noncrystalline phase in the Ba-Cu system comounds. In contact with distilled water, YBa2Cu3O7-$\delta$ and Y2BaCuO5 did not have considerable heat liberation, but in the binary compounds of the Ba-Cu-O system, the amount of total heat liberation was increased with respect to the Cu content. It might be that the reaction of high temperature superconductor YBa2Cu3O7-$\delta$ with water and/or moisture originated from the unusual oxidation state of Cu ion and the presence of amorphous Ba-Cu oxide compound. The degradation of high Tc superconductor by moisture and water could be controlled by restricting the heterogeneous distribution of Tc comlposition and the formation of second phase, such as stable Y2BaCuO5, and the resulting unstable Ba-Cu oxide compound.

  • PDF

THE PERFORMANCE OF CLAY BARRIERS IN REPOSITORIES FOR HIGH-LEVEL RADIOACTIVE WASTE

  • Pusch, Roland
    • Nuclear Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.483-488
    • /
    • 2006
  • Highly radioactive waste is placed in metal canisters embedded in dense clay termed buffer. The radioactive decay is associated with heat production, which causes degradation of the buffer and thereby time-dependent loss of its waste-isolating potential. The buffer is prepared by compacting air-dry smectite clay powder and is initially not fully water saturated. The evolution of the buffer starts with slow wetting by uptake of water from the surrounding rock followed by a long period of exposure to heat, pressure from the rock and chemical reactants. It can be described by conceptual and theoretical models describing processes related to temperature (T), hydraulic (H), mechanical (M) and chemical performance (C). For temperatures below 90 C more than 75 % of the smectite will be preserved for 100 000 years but cementation may reduce the excellent performance of the buffer to a yet not known extention.

Parametric Study on the Heat Loss of the Reactor Vessel in the Nuclear Power Plant (원자력 발전 원자로 용기의 열손실 설계인자에 관한 연구)

  • Jong-Ho Park;Seoug-Beom Kim
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.827-836
    • /
    • 2004
  • The design parameter of the heat loss for the pressurized water reactor has been studied. The heat loss from the reactor vessel through the air gap. insulation are analysed by using the computational fluid dynamics code, FLUENT. Parametric study has been performed on the air gap width between the reactor vessel wall and the inner surface of the insulation, and on the insulation thickness. Also evaluated is the performance degradation due to the chimney effect due to gaps left between the panels during the installation of the insulation system. From the analysis results, the optimal with of air gap and insulation thickness and the value of heat loss are obtained The results show how the heat loss varies with the air gap width and insulation thickness. The temperature and the velocity distributions are also presented. From the results of the evaluation. the optimal air gap width and the optimal insulation thickness are obtained. As the difference between the predicted heat loss and measured heat loss from the reactor vessel is construed Primarily as losses due to chimney effect. the contribution of the chimney effect to the total heat loss is quantitatively indicated.

Sensitivity Analysis on Design Factor of Ground Heat Exchanger for Optimum Design of Vertical Ground Source Heat Pump System (수직밀폐형 지중열교환기의 최적설계를 위한 설계인자 영향도 분석)

  • Bae, Sangmu;Kim, Hongkyo;Nam, Yujin
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.87-93
    • /
    • 2018
  • Ground source heat pump(GSHP) system is one of the high efficiency heat source systems which utilizes the constant geothermal energy of a underground water or soil. However, the design of conventional GSHP system in the domestic market is dependent on the experience of the designer and the installer, and it causes increase of initial installation cost or degradation of system performance. Therefore, it is necessary to develop a guideline and the optimal design method to maintain stable performance of the system and reduce installation cost. In this study, in order to optimize the GSHP system, design factors according to ground heat exchanger(GHX) type have been examine by simulation tool. Furthermore, the design factors and the correlation of a single U-tube and a double U-tube were analyzed quantitatively through sensitivity analysis. Results indicated that, the length of the ground heat exchanger was greatly influenced by grout thermal conductivity for single U-tube and pipe spacing for double U-tube.

Experimental study of sodium fire and its characteristics under the coupling action of columnar liquid sodium flow and concrete

  • Huo, Yan;Zou, Gao-Wan;Dong, Hui;Lv, Jian-Fu;He, Jian
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2866-2877
    • /
    • 2021
  • The complex coupling relationship between liquid sodium and concrete materials affects both the sodium fire characteristics and concrete properties through heat and chemical erosion. In this study, experiments on direct and indirect (separated by a steel plate) contact of the columnar sodium fire with the concrete surface were performed. It was found that the combustion efficiency of liquid sodium in direct contact with concrete was significantly enhanced and accompanied by intermittent explosions and splashing of small concrete fragments. The sodium fire on the surface of the concrete considerably increased the internal temperature, pore size, and distribution density of the concrete. In addition, the depth of influence on the loosening of the concrete structure was also greatly extended. The contact of liquid sodium with the concrete substantially affected its permeability resistance. The water absorption of the concrete surface was increased by more than 70% when liquid sodium directly impacted the bare concrete surface. However, the change in water absorption in the centre of the concrete was primarily affected by the duration of the external heat.