• Title/Summary/Keyword: Water addition

Search Result 9,546, Processing Time 0.045 seconds

Determination of Water-to-Binder Ratios on the Equivalent Compressive Strength of Concrete with Supplementary Cementitious Materials (혼화재 치환 콘크리트의 등가 압축강도에 대한 물-결합재비의 결정)

  • Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.687-693
    • /
    • 2015
  • The present study proposed a k-value to determine the water-to-binder ratio of concrete using fly ash (FA) or ground granulated blast-furnace slag (GGBS) as a partial replacement of ordinary portland cement (OPC) with regard to an equivalent strength of OPC concrete. From the regression analysis using an extensive database including 7076 concrete mixes, k-values were determined for various water-to-binder ratios when the replacement ratio of OPC by the addition of FA or GGBS were below 50%. For deriving an equation to identify k-value, the relationship of concrete compressive strength and water-to-binder ratio was generalized by an exponential function. In general, k-values decreased with the increases in the addition of FA or GGBS for replacement of OPC and water-to-binder ratio. The rate in decreasing k-value against water-to-binder ratio was marginally affected by the addition of FA or GGBS, although a higher k-value was commonly obtained for GGBS concrete than for FA concrete at the same water-to-binder ratio. Consequently, the determined k-values were simplified as a function of water-to-binder ratio and the addition ratio of FA or GGBS as replacement of OPC.

Bacterial Aggregates Formation After Addition of Glucose in Lake Baikal Water

  • Spiglazov Lev P.;Drucker Valentin V.;Ahn Tae Seok
    • Journal of Microbiology
    • /
    • v.42 no.4
    • /
    • pp.357-360
    • /
    • 2004
  • For determining the process of bacterial aggregation, glucose was added into water from Lake Baikal which had been stored for seven months. In the presence of a higher concentration of glucose, the abun­dance of single bacteria and aggregates were higher, but the biovolumes of both bacteria were similar. Theses results mean that both free-living and aggregated bacteria have similar maximum sizes and that aggregates are forming with available organic materials. With available organic materials, the biovol­ume of aggregates becomes larger.

The Effects of Hot Water Extraction of Wood Meal and the Addition of CaCl2 on Bending Strength and Swelling Ratio of Wood-Cement Board (목질(木質)의 열수추출(熱水抽出) 및 CaCl2 첨가(添加)가 목질(木質)-세멘트 보드의 휨강도(强度) 및 팽윤율(膨潤率)에 미치는 영향(影響))

  • Ahn, Won-Yung;Shin, Dong-So;Choi, Don-Ha
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.49-53
    • /
    • 1985
  • The effects of pre-treatments, the hot water extraction of wood meal and the addition of chemical ($CaCl_2$) to wood-cement water system on the properties of wood-cement composite such as modulus of rupture (MOR), modulus of elasticity (MOE), water sorption ratio and swelling ratio of resulting boards were studied in this experiment. The wood meals through 0.83mm(20 mesh) and retained on 0.42mm(35 mesh) screen were prepared from Pinus densiflora S. at Z. and Larix leptolepsis G. For hot water extraction, 500 grams of wood meal for each species were heated to boiling with 1,500ml of distilled water in 2-liter beaker for 6 hours. Every 2 hours, the wood meals were washed with boiling distil1ed water and reheated to boiling again. After 6 hours boiling, the boiled wood particles were collected by pouring this particles on 200 mesh screen. The collected particles then washed twice with hot distilled water and dried for 24 hours in an oven at $109{\pm}20^{\circ}C$. A mixture of 663.4 grams of cement with 331.7 grams of wood meal based on oven-dry weight were dry-mixed in a plastic vessel. The mixture was kneaded with 497.6ml of distilled water in the ratio of 1.5ml of water to a gram of wood meal. To add calcium chloride to the mixture as an accelerator, $CaCl_2$ 4% solution by weight per volume, was added to pine-or larch-cement board in the ratio of 3% to cement weight. To set wood-cement board, this mixture was clamped at 30cm ${\times}$ 30cm, in thickness of 1.5cm for 3 days at room temperature, declamped and then placed at open condition for 17 days. The target density was 1.0. The four specimens sized to 5cm in width and 28cm in length were used for MOR and MOE test for each treatment. After MOR test, the tested specimens were cut to the size of 5cm ${\times}$ 5cm for water sorption and swelling test. The twenty specimens used to measure the water sorption ratio (soaking 24 hours) and ten of these were used for swelling ratio measurement The results obtained were as follows: 1) Larch was not suitable for wood-cement boards because larch-cement board developed no strength, but pine showed 97.9kg/$cm^2$ by hot water extraction. 2) To increase MOR, hot water extraction was more effective than the addition of $CaCl_2$ in pine and larch because the $CaCl_2$ addition was seemed to speed up the ratio of cement hydration without reacting with the wood substances. 3) The water sorption ratio was lowered by the addition of $CaCl_2$ to wood-cement system because the chemical additive accelerated the rate of cement hydration. 4) In pine-cement board, the swelling ratio from 0.37 to 0.42 percent was observed in length and the swelling ratio from 0.88 to 2.0 percent in thickness. As a rule, the swelling ratio of wood-cement board was very low and the swelling ratio in thickness was higher than in length.

  • PDF

A Study on the Evaluation of the Water-soluble Chloride Content and Free-chloride Content in Blast Furnace Slag Cement Pastes (고로 슬래그 시멘트 페이스트 내 자유염화물량과 물가용성 염화물량 평가에 관한 연구)

  • Jo, Young-Kug;So, Seung-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.4
    • /
    • pp.95-101
    • /
    • 2004
  • The purpose of this paper is to compare free-chloride content with water-soluble chloride in blast furnace cement(BSC) paste. The content of free-chloride in cement paste measured by pore solution analysis and water-soluble chloride measured by ASTM. The result of this study are as follows: 1. The concentration of chloride ion in pore solution of BSC-solidified matrix is almost as low as 43-71% compared to that of OPC-solidified matrix containing the same chloride content in cement paste. 2. The binding capacity of specimens, OPC Pl-P5, are 93.5-77%, but the binding capacity of specimens, BSC Pl-P5 are 97.1-86.1%, which is to be as high as 2-9.1% compared to OPC containing the same chloride content. 3. In terms of water-soluble chloride content in BSC paste are 15-31.7 percent of chloride addition but free-chloride content in pore solution are 2.9-13.9 percent of chloride addition. The free-chloride content in pore solution is 19.3-43.8 percent lower for the water-soluble chloride content in cement paste.

Breathability of Breathable Fabrics for Sportswear according to Measuring Method (투습도 측정방법에 따른 스포츠웨어용 투습직물의 투습특성)

  • Kim, Hyun-Ah;Kim, Seung-Jin
    • Fashion & Textile Research Journal
    • /
    • v.19 no.4
    • /
    • pp.493-503
    • /
    • 2017
  • This study investigated water vapor permeability of the 73 breathable fabrics for sports-wear according to the materials, finishing methods and fabric structural parameters. The water vapor permeability by KS K 0594 method of PET breathable fabric was superior than that of nylon one, in addition, water vapor permeability of coated or laminated breathable fabrics were higher than those of hot melt or dot laminated fabrics. The water vapor permeability of breathable fabric was dependent on the thickness, weight and density, which was consistent with measuring method. However, water vapor permeability according to materials and finishing method showed different results according to measuring method. The correlation coefficient of WVP of PET breathable fabrics between ISO and KS K measuring methods was -0.83 and the correlation coefficient of WVP of coated breathable fabrics was -0.72 and -0.71 for KS K and ASTM and -0.72 for KS K and ISO in hot melt laminated breathable fabrics. According to regression analysis, WVP of PET breathable fabric by both KSK and ISO measuring methods was highly dependent upon on the density and weight. In addition, WVP of hot melt laminated breathable fabric was highly dependent upon thickness, weight and density. Therefore, relevant measuring method for WVP of breathable fabrics has to be adopted to measure precise breathability.

The Effects of Water Extract of Genus Panax on Rat Blood Vessels (Panax 속 한약재가 흰쥐 혈관운동성에 미치는 영향에 관한 비교 연구)

  • 유기덕;최호영;이재성;안덕균;김형환
    • The Journal of Korean Medicine
    • /
    • v.25 no.1
    • /
    • pp.60-71
    • /
    • 2004
  • Objectives : We have examined the relaxational response to the water extract of genus Panax in rat thoracic aorta and mesenteric artery. Methods : Segments of thoracic aorta and mesenteric artery obtained from rats immediately after delivery were mounted in organ baths superfused on a polygraph. Results : We found that the thoracic aorta segments responded to the water extract of genus Panax with a dose-dependent vasorelaxation. At $10^{-5}m$ 5-hydroxytrptamine (5-HT), the maximal contraction force were 94.9% of the maximum KCl-response. At $10^{-5}m$ 5-HT - induced contraction, The contractile response of thoracic aortic rings were inhibited by 54.7%, 36.3% and 31.3% after addition of the high concentration (100 mg/ml) of water extract of Panax ginseng, Panax japonicus and Panax quinquefolium. The contractile response of mesenteric arteries were inhibited by 88.3%, 87.7%, and 70.3% after addition of the high concentration (100 mg/ml) of water extract of Panax ginseng, Panax japonicus and Panax quinquefolium. Conclusions : In conclusion, water extract of genus Panax - induced relaxation in the isolated rat thoracic aorta and mesenteric artery were composed of endothelium - independent relaxation and dose - dependent relaxation.

  • PDF

An Investigation of Combustion Emission Characteristics of Kerosene Fan Heater with Addition of Water Droplets by Ultrasonic Atomizer (초음파 수첨가 연소에 의한 석유 홴 히터의 배기가스 특성 고찰)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.44-53
    • /
    • 1999
  • This study is concerned with the emission characteristics of kerosene fan heater, which is burned with kerosene and water droplets simultaneously in the burner, in order to prohibit the emissions of harmful exhaust gas and reduce smell caused by incomplete combustion, and the addition of water droplets to the conventional kerosene fan heater was performed by ultrasonic atomizer. For the investigation of this study, the measurement of exhaust gas components and exhaust gas temperature was carried out by using an automatic combustion gas analyser and $NO_x$ analyser, and the measurement of consumption weight of oil and water was obtained by using electric digital balance. Consequently, according as the water percent weight ratio of about $21{\sim}23%$ was supplied for this study, it was found that the combustion-generated $NO_x$ and CO emissions were reduced very largely, but the emissions of $O_2\;and\;CO_2$ and the temperature of exhaust gas were not changed.

  • PDF

Carbonate scale reduction in reverse osmosis membrane by CO2 in wastewater reclamation

  • Shahid, Muhammad Kashif;Pyo, Minsu;Choi, Young-Gyun
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.125-136
    • /
    • 2017
  • Reverse osmosis technology is being used on large scale for treatment of ground water, brackish water, wastewater and sea water. The most challenging issue in RO process is carbonate scaling which is directly linked with the efficiency and economy. Considering the natural phenomena of carbonate scaling different adaptations have been made to control scaling on the surface of RO membrane including acid dosage and antiscalant addition. As carbonate scaling is directly related with pH level of feed water, present study describes an experimental approach to reduce scaling on RO membrane by lowering the feed water pH by purging $CO_2$. In this comparative study four different conditions including control process (without any scale inhibitor), with dosage of antiscalant, with purging of $CO_2$ and with co addition of antiscalant and $CO_2$ in a feed stream line; it was established that $CO_2$ is a better appliance to reduce carbonate scaling on the membrane surface by reduce pH of feed stream. It was also observed that $CO_2$ and antiscalant mutually function better for scale control.

Implementation of Hydrological Survey Scheduling using Real-Time Water Level Information (실시간 수위정보를 활용한 수문조사 스케줄링 구현)

  • Jae Myeong Choi
    • Journal of Platform Technology
    • /
    • v.11 no.2
    • /
    • pp.66-75
    • /
    • 2023
  • Hydrological survey measurement technology has improved due to the introduction of high-tech equipment and advances in technology, but hydrological survey still requires a lot of manpower and time, and the manpower invested is very limited compared to the size and scope of work. In addition, although automatic flow measurement facilities are in operation, it is difficult to expand them nationwide due to limited field conditions. Therefore, it is necessary to improve the operating infrastructure and environment rather than the measurement technology itself for hydrological investigation. In addition, in terms of flow investigation, it is necessary to schedule an investigation using real-time water level information in order to inventory the accuracy of the water-flow relationship equation and improve work efficiency. Therefore, in this paper, research related to domestic hydrological surveys was analyzed and a hydrological survey scheduling system using real- time water level information based on Open API was implemented to increase the economic and efficiency of hydrological surveys.

  • PDF

Properties of Water-based Paint mixed with Photocatalyst for Indoor Air Quality Improvement (실내 공기질 개선을 위한 광촉매를 혼입한 수성도료의 특성)

  • Choi, Byung-Cheol;Park, Chae-Wool;Kyoung, In-Su;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.29-30
    • /
    • 2020
  • As the modern society enters, the building becomes sealed and the public's interest in the environment increases, so the interest in indoor air pollution increases and the environmental pollution is raised as an important issue not only outdoors but also indoors. In addition, the emergence of sick house syndrome (SHS) has increased the interest in formaldehyde and is a cause of deteriorating indoor air quality. Accordingly, this study prepared a functional paint by incorporating a photocatalyst in an aqueous paint, and conducted formaldehyde adsorption experiments and functional evaluation. As a result of the experiment, as the photocatalyst was added, the formaldehyde adsorption performance tended to increase. In addition, as a result of measuring the impact resistance and alkali resistance according to the KS standard, there is no difference in residual cracks and cracks between the water-based paint without the photocatalyst and the water-based paint with the photocatalyst added. Therefore, it is considered that the water-based paint added with a photocatalyst can improve the indoor air quality by adsorbing formaldehyde and can be used as a functional paint because the functionality is not different from that of a general water-based paint.

  • PDF