• Title/Summary/Keyword: Water Vapor Pressure

Search Result 422, Processing Time 0.025 seconds

Theoretical Analysis on the Factors Affecting the Power Efficiency of the Kalina Cycle (칼리나 사이클의 발전효율에 영향을 미치는 요소에 관한 이론적 해석)

  • Lee, Ki-Woo;Chun, Won-Pyo;Shin, Hyeon-Seung;Park, Byung-Duck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5425-5433
    • /
    • 2014
  • This study examined the effects of the key parameters on the power efficiency of the waste heat power plant using the EES program to obtain data for the design of the 20kW Kalina power plant. The parameters include the ammonia mass fraction, vapor pressure, heat source temperature, and the cooling water temperature. According to the analyses, a lower ammonia mass fraction and a higher vapor pressure increase the efficiency, in general. On the other hand, this study shows that there is a specific region with a very low ammonia mass fraction, where the efficiency decreases with ammonia mass fraction. Regarding the vapor pressure at the turbine inlet, the power efficiency increases with increasing vapor pressure. In addition, it was found that the influence of the vapor pressure on the efficiency increases with increasing ammonia mass fraction. Finally, the optimal condition for the maximum power efficiency is defined in this study, i.e., the maximum efficiency was 15% with a 25bar vapor pressure, $160^{\circ}C$ heat source temperature, $10^{\circ}C$ cooling water temperature, and 0.4 ammonia mass fraction.

Program Development for Drawing of 26 Properties and System Analysis on T-s Diagram of Water or Vapor (물의 T-s 선도 상에서 26 종류의 물성치 작도 및 시스템 해석 프로그램 개발)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.157-164
    • /
    • 2008
  • The temperature-entropy diagram of water or vapor displays graphically the thermophysical properties, so it is very conveniently used in various thermal systems. On general T-s chart of water, there are temperature, pressure, quality, specific volume, specific enthalpy, specific entropy. However, various state and process values besides above properties can be plotted on T-s diagram. In this study, we developed the software drawing twenty six kinds of properties, that is temperature, pressure, quality, specific volume, specific internal energy, specific enthalpy, specific entropy, specific exergy, exergy ratio, density, isobaric specific heat, isochoric specific heat, ratio of specific heat, coefficient of viscosity, kinematic coefficient of viscosity, thermal conductivity, prandtl number, ion product, static dielectric constant, isentropic exponent, velocity of sound, joule-thomson coefficient, pressure coefficient, volumetric coefficient of expansion, isentropic compressibility, and isothermal compressibility. Also, this software can analyze and print the system values of mass flow rate, volume flow rate, internal energy flow rate, enthalpy flow rate, entropy flow rate, exergy flow rate, heat flow rate, power output, power efficiency, and reversible work. Additionally, this software support the functions such as MS-Power Point.

  • PDF

Approximate solutions on the absorption process of an aqueous LiBr falling film : effects of vapor flow (리튬브로마이드 수용액 유하액막의 흡수과정에 대한 근사 해법 : 증기 유동의 영향)

  • Kim, B.J.;Lee, C.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.144-152
    • /
    • 1997
  • Film absorption involves simultaneous heat and mass transfer in the vapor-liquid system. In the present work, the absorption process of water vapor by an aqueous soluton of LiBr flowing inside of the vertical tube was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the heat and mass transfer rate. Particularly the effects of vapor flow conditions on the absorption process were investigated in terms of the vapor Reynolds number. As the vapor Reynolds number increased, the shear stress at the vapor-solution interface also increased. Consequently solution film became thinner at higher vapor flowrate under the co-currentflow condition. Thinner film was capable of higher heat transfer to the wall and leaded to higher absorption rate of the water vapor into the solution film.

  • PDF

EFFECTS OF WATERY VAPOR CONCENTRATION ON DROPLET EVAPORATION IN HOT ENVIRONMENT

  • Lee, M.J.;Kim, Y.W.;Ha, J.Y.;Chung, S.S.
    • International Journal of Automotive Technology
    • /
    • v.2 no.3
    • /
    • pp.109-115
    • /
    • 2001
  • A study has been conducted to clarify the effect of watery vapor concentration in hot ambient on droplet evaporation. Droplets of water, ethanol, n-hexadecaneand n-heptane were used in this experimental study. Ambient conditions are fixed at 470 K in temperature, 0.1 MPa in pressure and 2 m/s in velocity of ambient air. Watery vapor concentration was changed 0%~40% by 10% by add water to air. To obtain the time histories of droplet diameter after exposed in ambient, a suspended droplet in hot and humid ambient stream was synchronized with a back flash light, and enlarged droplet images were taken by a CCD camera. The evaporation rate constant of water droplet decreases slightly with the vapor concentration because diffusion velocity reduction of droplet vapor occurs on the surface. The values of ethanol and n-heptane droplet actively increase by effect that water from condensation of vapor flows into the droplet. The evaporation rate constant of n-hexadecane which has higher boiling point than water increases within around 30% of the concentration.

  • PDF

Effects of Water Vapor Concentration on a Droplet Evaporation (액적의 증발에 미치는 수증기 농도의 영향)

  • Kim, Y.W.;Lee, M.J.;Ha, J.Y.;Chung, S.S.
    • Journal of ILASS-Korea
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 1999
  • An experimental study has been conducted to clarify the effect of vapor on droplet evaporation. Droplets of water, ethanol, n-hexadecane and n-heptane were exposed in air stream. Temperature, pressure, and flow velocity in the ambient air are 470K, 1 atm, and 2m/s, respectively. Measurements are carried out for the wide range of water vapor concentration$(0%\sim40%)$. To obtain the time histories of droplet diameter, suspended droplet in hot and humid air stream was synchronized with a back flash light, and enlarged droplet images were taken on a CCD camera. With the vapor concentration increasing, the evaporation rate constant of water droplet decrease slightly and the droplet of ethanol and n-heptane increase actively. The evaporation rate constant of n-hexadecane which has higher boiling point than water increases within around 30% of the concentration.

  • PDF

Analysis on Characteristics of Radiosonde Bias Using GPS Precipitable Water Vapor

  • Park, Chang-Geun;Baek, Jeong-Ho;Cho, Jung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.3
    • /
    • pp.213-220
    • /
    • 2010
  • As an observation instrument of the longest record of tropospheric water vapor, radiosonde data provide upper-air pressure (geopotential height), temperature, humidity and wind. However, the data have some well-known elements related to inaccuracy. In this article, radiosonde precipitable water vapor (PWV) at Sokcho observatory was compared with global positioning system (GPS) PWV during each summertime of year 2007 and 2008 and the biases were calculated. As a result, the mean bias showed negative values regardless of the rainfall occurrence. In addition, on the basis of GPS PWV, the maximum root mean square error (RMSE) was 5.67 mm over the radiosonde PWV.

Effect of radiation model on simulation of water vapor - hydrogen premixed flame using flamelet combustion model in OpenFOAM

  • Kim, Sangmin;Kim, Jongtae
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1321-1335
    • /
    • 2022
  • This study was conducted to investigate the effect of absorption coefficient models on the P1 radiation model for a premixed hydrogen flame containing the water vapor. A CFD combustion simulation analysis was performed using XiFoam, one of the open-source CFD solvers in OpenFOAM. The solver using the flamelet combustion model has been modified to implement radiative heat transfer. The absorption coefficient models used in this study the grey-mean model and constant model, and for comparison, case without radiation was added. This CFD simulation study consisted of benchmarking the THAI HD-15 and HD-22 experiments. The difference between the two tests is the inclusion of water vapor in the condition before ignition. In the case of the HD-22 experiment containing water vapor in the initial condition, the simulation results show that the grey-mean absorption coefficient model has a strong influence on the temperature decrease of the flame and on the change in pressure inside the vessel.

Electrical Conduction in $SrZr_{0.95}Y_{0.05}O_{2.975}$ Ceramics

  • Baek, Hyun-Deok;Noh, Jin-Hyo
    • The Korean Journal of Ceramics
    • /
    • v.5 no.3
    • /
    • pp.288-295
    • /
    • 1999
  • Partial conductivities contributed by electron holes, oxygen ions, and protons were caluclated in $SrZr_{0.95}Y_{0.05}O_{2.975}$, using the reported formulae derived from the defect chemistry of HTPCs. Required parameters were obtained from the graphical analysis of total conductivity variation against partial pressure of water vapor and oxygen. Predicted overall conductivities showed a reasonable agreement with experimental measurements. The conductivity of the material showed a linear increase with square root of the water vapor pressure. This increase was due to proton conduction in an almost pure ionic conductivity. The calculation of partial conductivities at $800^{\circ}C$ resulted in an almost pure ionic conductivity at $P_{02}=10^{-10}$ atm and a predominant hole conductivity at $P_{02}=10^{-10}$ atm. Pure proton conduction was not expected at this temperature, contrary to the earlier reports. Discussions were made in relation with reported thermodynamic data and defect structure of the material. It was shown that from the total conductivity dependence on water vapor pressure, the pure ionic conductivity at low oxygen partial pressures could be separated into protonic and oxygen ionic conductivity in $ZrO_2$-based HTPCs.

  • PDF

Comparison of Photosynthetic Responses in Allium microdictyon Prokh and Allium ochotense Prokh from Atmosphere-Leaf Vapor Pressure Deficit (VPD) (대기-엽 수증기압차에 의한 산마늘과 울릉산마늘의 광합성 반응 비교)

  • Lee, Kyeong-Cheol;Kim, Ha-Sun;Noh, Hee-Sun;Kim, Jongh-Wan;Han, Sang-Sup
    • Korean Journal of Medicinal Crop Science
    • /
    • v.20 no.3
    • /
    • pp.171-176
    • /
    • 2012
  • This study was conducted to investigate the effect of atmosphere-leaf vapor pressure deficit (VPD) in Allium microdictyon Prokh. and Allium ochotense Prokh. The vapor pressure deficit (VPD) was rapidly increased with increasing temperature and decreasing relative humidity. Taken as a whole, the stomatal transpiration reaction was slightly late with increading of VPD. Maximum photosynthetic rate at high-VPD condition was 5.98 ${\mu}mol$ $CO_2{\cdot}m^{-2}{\cdot}s^{-1}$ in Allium microdictyon, which was a little lower than 6.59 ${\mu}mol$ $CO_2{\cdot}m^{-2}{\cdot}s^{-1}$ in Allium ochotense, respectively. After 2 p.m, stomatal transpiration of Allium microdictyon at the high VPD condition were rapidly decreased. Ci/Ca began to decline sharply at 8 a.m and showed the lowest value at 2 p.m, The results showed that Ci/Ca decreased with being used $CO_2$ in the mesophyll intercellular space for photosynthesis. In high VPD condition, The water potential values showed the highest at 5 a.m, and the lowest at 1 p.m in high VPD condition. The water saturation deficits (WSD) in high VPD condition showed about 1.5 times higher than in low VPD condition. The results indicated that physiological activities in Allium microdictyon is more limited from high VPD conditions.

Effect of Fiber Content, Yarn Size and Construction of Knit Fabrics on the Buffering Capacity against Water Vapor (편성물의 섬유의 종류, 실의 굵기 및 니트타입에 따른 투습완충능력)

  • Yoo, Hwa-Sook;Hu, Yoon-Sook;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.1
    • /
    • pp.228-238
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of chacteristics of knit fabrics on the microclimate of the skin simulating system. To determine the effect of characteristics of knit fabrics, vapor state of sweat pulse was simulated in the closed system. Different contents of fibers such as cotton, wool and polyester with different yarn size and knit types were chosen for specimens. The changes of humidity and temperature of air layer in the simulated systems were measured. Buffering indices, $K_d$ and $\beta_r$, were determined by considering $\alpha_p, \DeltaP_{max}, t_{max}, and tan\beta$. Physical properties of knit fabrics such as thickness, porosity, air resistance and moisture vapor transport were measured. Results showed that vapor pressure of wool was lower than cotton or polyester This was attributed to the hydrophilicity of wool which absorbed moisture rather quickly and retained in the knit fabric. The time to decrease vapor pressure was faster for polyester than cotton or wool. As a result, $K_d$ was in the order of wool> polye, item> cotton. $\beta_r$ of wool was rower than cotton or polyester due to its lowers porosity and slower desorption rate. For the yarn size, $K_d$ was in the order of 80's> 60's> 30's; thinner and lighter yarn showed better water vapor transport property. For knit type, buffering capacity of single jersey was better than interlock knit fabric. Statistical analysis showed that the air permeability was the most influential factor far the water vapor transport properties.

  • PDF