• Title/Summary/Keyword: Water Vapor Pressure

Search Result 422, Processing Time 0.028 seconds

Development of Nano Ceramic Structures for HEPA Type Breathing Wall (HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발)

  • Kim, Jong-Won;Ahn, Young-Chull;Kim, Gil-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

A Study on the Heat Storage System for Chemical Heat Pump Using Inorganic Hydrates(I) - Heat Storage Characteristics - (화학열펌프에 있어서의 무기수화물계 축열시스템에 관한 연구(I) - 탈수 축열 성능연구 -)

  • Park, Young-Hae;Kim, Jong-Shik
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.29-38
    • /
    • 1995
  • The heat-storage characteristics accompanied by exothermic reaction at the regeneration of $Ca(OH)_2$ in tile heat-storage mode of a chemical heat pump system using a $Ca(OH)_2/CaO$ reversible thermochemical reaction was examined in a lab-scale unit. In this heat-storage mode, the particle bed of CaO could be regenerated by heating the $Ca(OH)_2$ packed bed to the higher temperature at which the equilibrium pressure in the reactor is greater than the water vapor pressure in the condenser. The results are i) the dehydration, thermal decomposition, rate of $Ca(OH)_2$ was higher at the lower part of particle bed than at the upper part, ii) in the reactor, the dehydration was proceeded along radial and axial direction, from inner part to the outer part, which explains heat transfers from the center to wall and from the tenter to lower or upper part of reactor.

  • PDF

Syngas/Diesel Dual Fuel Combustion in a Compression Ignition Engine with Different Composition Ratios of Syngas and Compression Ratios (합성가스/디젤 혼소압축착화 엔진의 합성가스 혼합비와 압축비에 따른 연소 및 배출가스 특성)

  • Lee, Junsun;Chung, Tahn;Lee, Yonggyu;Kim, Changup;Oh, Seungmook
    • Journal of ILASS-Korea
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2019
  • Syngas is widely produced by incomplete combustion of coal, water vapor, and air (oxygen) in a high-temperature/high-pressure gasifier through a coal-gasification process for power generation. In this study, a simulation syngas which was mainly composed of $H_2$, CO, $CO_2$, and $N_2$ was fueled with diesel. A modified single cylinder compression ignition (CI) engine is equipped with intake port syngas supply system and mechanical diesel direct injection system for dual fuel combustion. Combustion and emission characteristics of the engine were investigated by applying various syngas composition ratios and compression ratios. Diesel fuel injection timing was optimized to increase indicated thermal efficiency (ITE) at the engine speed 1,800 rpm and part load net indicated mean effective pressure ($IMEP_{net}$) 2 to 5 bar. ITE of the engine increased with the $H_2$ concentration, compression ratio and engine load. With 45% of $H_2$ concentration, compression ratio 17.1 and $IMEP_{net}$ 5 bar, ITE of 41.5% was achieved, which is equivalent to that of only diesel fuel operation.

Evapotranspiration Measurements using an Eddy Covariance Technique in the Seolmacheon Catchment (에디 공분산으로 관측된 설마천 산림 유역의 증발산)

  • Kwon, Hyou-Jung;Kim, Joon;Lee, Jung-Hoon;Jung, Sung-Won;Lee, Jin-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1112-1116
    • /
    • 2009
  • The importance of securing water resources and their efficient management has attracted more attention recently due to water deficit. In water budget analysis, however, evapotranspiration (${\lambda}E$) has been approximated as the residual in the water balance equation or estimated from empirical equations and assumptions. To minimize the uncertainties in these estimates, it is necessary to directly measure ${\lambda}E$. In this study, using the eddy covariance technique, we have measured ${\lambda}E$ in a mixed forest in the Seolmacheon catchment in Korea from September 2007 to December 2008. During the growing season (May - July), ${\lambda}E$ in this mixed forest averaged about 2.2 mm $d^{-1}$, whereas it was on average 0.5 mm $d^{-1}$ during the non-growing season in winter. The annual total ${\lambda}E$ in 2008 was 581 mm $y^{-1}$, which is about 1/3 of the annual precipitation of 1997 mm. Despite the differences in the amount and frequency of precipitation, the accumulated ${\lambda}E$ during the overlapping period (i.e., September to December) for 2007 and 2008 was both ${\sim}$ 110 mm, showing virtually no difference. The omega factor, which is a measure of decoupling between forest and the atmosphere, was on average 0.5, indicating that the contributions of equilibrium ${\lambda}E$ and imposed ${\lambda}E$ to the total ${\lambda}E$ were about the same. The results suggest that ${\lambda}E$in this mixed forest was controlled by various factors such as net radiation, vapor pressure deficit, and canopy conductance. In this study, based on the direct measurements of ${\lambda}E$, we have quantified the relative contribution of ${\lambda}E$in the water balance of a mixed forest in the Seolmacheon catchment. In combination with runoff data, the information on ${\lambda}E$ would greatly enhance the reliability of water budget analysis in this catchment.

  • PDF

Reviewing the Explosively Deepening Cyclone(Cyclonic Bomb) over the East Sea with the Satellite Observations (위성관측에 의한 동해상의 폭발적 저기압의 고찰)

  • 정효상
    • Korean Journal of Remote Sensing
    • /
    • v.12 no.2
    • /
    • pp.126-138
    • /
    • 1996
  • The characteristics of rapid development of the low pressure system over the East Sea from 06 to 08 Nov., 1995 has been analyzed in detail by the synoptic numerical products and satellite observations. The Low system was initially triggered the development of the baroclinic leaf cloud over the border of the northern part of Korea and China and moved eastward and then developed explosively com-ma or lambda type cloud system over the East Sea. To forecast well the general development and movement of the coastal winter cyclone over the East Sea popularly in a numerical simulation by several scientists, the large baroclinicity, continuous support of water vapor, and sequential cold outbreak over the warm sea surface have been more commonly concerned about. The cyclone which the central surface pressure was dropped 40hPa within 24 hours has often accompanied strong wind and heavy snow- or rain-fall in the winter season. In all successive observations with 12-hourly satellite imagery and analyzed meteorological variables in this period, the centers of the sea-level pressure and 500hPa geopotential height associated with this cyclone were typically illustrated by moving farther eastward using GMS combined enhanced IR images. The maxi-mum wind sustained by this system with the intensity and central pressure of tropical storm was about 60 knots with the center pressure drop of 44hPa/day similar to the North American cyclonic bomb and Atlantic storm.

A Study on the Fog Occurrence in Suyoung Bay (수영만의 안개 발생에 관한 연구)

  • Jo, Gyu-Dae;Kim, Sun-Yeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.3
    • /
    • pp.254-264
    • /
    • 1990
  • Using the meteorological data, surface weather map, and oceanographic data for 5 years(1984-1988). I investigated the characteristics of the fog occurrence and the role of the inshore in Pusan about the fog occurrence. And the meteorological data and sea surface temperature(SST), which were observed in July, 1989 in Suyoung Bay, were compared with those in Pusan. The fogs in Pusan concentrate in May, June and July. And at fog occurrence time the principal wind directions are Southwest(SW) winds, which easily supply with water vapor, and a series of Northeast(NE) wind. At the fog days pressure patterns are pattern 7 in spring time (March, April, and May) and pattern 10 and pattern 13 in summer time (June, July, and August). Also the advection fog(sea fog) is closely related with the relationship between warm and cold advection in 850~700mb and cold and warm SST rather than the increase of the instability of atmosphere in 850~500mb. The fogs in Taegu, which is the inland region, mainly occur at dawn in fall time due to the strong night radiation fog. On the other hand in Pusan the coastal region, the fogs occur from late spring time to summer time (May, June, and July). Because there is the abundant supply of the water vapor from the ocean owing to a series of South(S) wind at this time. Then the atmosphere, which has high relative humidity, reaches easily the supersaturation by the radiation cooling. In Suyoung Bay and Pusan the meteorological observation data, SST and fog days are almost similar. And I think that the mechanism of the fog occurrence nearly accords with both regions.

  • PDF

A Kinetics Study of Rn Daughter and Atmospheric Trace Gas Using Alpha Track Detection (알파비적검출방법에 의한 대기중 라돈딸핵종의 화학적 동특성연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.79-83
    • /
    • 1995
  • A number of investigators have reported formation of radiolytic ultrafine particles produced by the interaction of ionizing radiation with atmospheric trace gases. Previous studies have suggested that a very high localized concentration of the hydroxyl radical produced by the radiolysis of water can react with atmospheric trace gases such as $SO_2$ and produce lower vapor pressure compounds that can subsequently nucleate. To determine the trace gas and water vapor concentration dependence of the active, positively charged, first decayt product of radon (Po-218), a well-controlled radon chamber was used in this research. The mobility spectrum of the decay products in the range of $0.07-5.0cm^2/V\;sec$ from the radon chamber was measured using alpha track detector installed inside a specially-designed electrostatic spectrometer. Measurements were taken for different concentrations (0.5ppm to 5ppm) of $SO_2$ in Purified, Compressed air. A kinetics Study following the clustering of $SO_2$ around the $PoO_x^+$ ion in an excess of $SO_2$ for interpretation of the reaction processes was performed.

  • PDF

Difference in canopy and air temperature as an indicator of crop water stress and its feasibility for irrigation scheduling (작물 캐노피 온도와 대기온도간의 상관관계 분석 및 활용 연구)

  • Kim, Minyoung;Choi, Yonghun;Jeon, Jonggil;Kim, Youngjin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.131-131
    • /
    • 2017
  • 작물의 체온인 엽온은 작물의 증발산량 또는 작물의 스트레스와 관련이 있으며, 일반적으로 일사, 풍속, 습도 등 기상조건과 잎의 크기, 형태 등 생리작용 등에 의해 지배된다. 엽온을 작물의 수분스트레스지수, 증발산량 등을 산정하기 위한 인자로 많이 활용되고 있으며, 최근 ICT 기술의 발달로 인해 열영상 카메라, 적외선 센서 등을 활용해서 실시간 측정을 하고, 정보를 작물 생육환경 제어에 활용하는 연구들이 많이 이루어지고 있다. 본 연구에서는 시설오이를 대상으로 캐노피 온도(Canopy temperature, $T_c$)와 대기온도(Air temperature, $T_a$)간의 상관관계, 또 ($T_c-T_a$)와 포화수증기압차(Vapor pressure deficit, VPD)와의 관계를 분석하였다. 대기온도와 상대습도를 이용하여 산정된 VPD가 엽온에 미치는 영향을 분석한 결과, 엽온 증가에 따라 VPD가 증가하였으며, 캐노피와 대기온도간의 차이 또한 VPD간에 음의 상관관계($R^2=0.82{\sim}0.89$)가 나타났는데, 이는 대기온도에 따른 엽온과 포화수증기압의 상승이 원인인 것으로 나타났다. ($T_c-T_a$)와 VPD값을 이용하면 작물 수분스트레스(Crop Water Stress Index, CWSI)를 산정할 수 있는 데, 결과값을 분석한 결과 $T_c$$T_a$의 차가 적은 경우 CWSI값이 증가함을 알 수 있었다. 향후 연구에서는 추가적으로 다양한 재배환경에서의 캐노피 온도, 포화수증기압차, 그리고 CWSI를 산정하여, 적정 생육 환경조성을 위한 지표로 활용할 계획이다.

  • PDF

A Study on Synthetic Method and Material Analysis of Calcium Ammine Chloride as Ammonia Transport Materials for Solid SCR (Solid SCR용 암모니아 저장물질인 Calcium Ammine Chloride의 합성방법 및 물질분석 연구)

  • Shin, Jong Kook;Yoon, Cheon Seog;Kim, Hongsuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.199-207
    • /
    • 2015
  • Solid materials of ammonia sources with SCR have been considered for the application of lean NOx reduction in automobile industry, to overcome complex problems of liquid urea based SCR. These solid materials produce ammonia gas directly with proper heating and can be packaged by compact size, because of high volumetric ammonia density. Among ammonium salts and metal ammine chlorides, calcium ammine chloride was focused on this paper due to low decomposition temperature. In order to make calcium ammine chloride in lab-scale, simple reactor and glove box was designed and built with ammonium gas tank, regulator, and sensors. Basic test conditions of charging ammonia gas to anhydrous calcium chloride are chosen from equilibrium vapor pressure by Van't Hoff plot based on thermodynamic properties of materials. Synthetic method of calcium ammine chloride were studied for different durations, temperatures, and pressures with proper ammonia gas charged, as a respect of ammonia gas adsorption rate(%) from simple weight calculations which were confirmed by IC. Also, lab-made calcium ammine chloride were analyzed by TGA and DSC to clarify decomposition step in the equations of chemical reaction. To understand material characteristics for lab-made calcium ammine chloride, DA, XRD and FT-IR analysis were performed with published data of literature. From analytical results, water content in lab-made calcium ammine chloride can be discovered and new test procedures of water removal were proposed.

Study of Hydration Reaction Characteristics of Inorganic Salts for Chemical Cold Storage and Method of Enhancement of Heat and Mass Transfer (화학축냉용 무기염들의 수화반응 및 열 및 물질전달 향상방안)

  • 김상욱;한종훈;황용준;이건홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.185-191
    • /
    • 1999
  • An air-conditioning system based on the chemical heat storage principle was considered. $H_2O$ was chosen as the reaction gas and the working fluid as well. Na$_2$S, CaCl$_2$, MnCl$_2$, BaCl$_2$, MgCl$_2$, Fe$_2$(SO$_4$)$_3$ and MnSO$_4$ were tested as the solid reactants by using Cahn pressure balance. Na$_2$S was superior to other salts in respect of high capability of absorption of water gas, 5 moles of $H_2O$ per unit mole of Na$_2$S, and adequate temperature of adsorption, $65^{\circ}C$ at 7torr, and of desorption, 13$0^{\circ}C$ at 76torr. Clausius-Clapeyron diagram of Na$_2$S was obtained via adsorption experiments at several vapor pressures of water gas. To enhance heat and mass transfer characteristics, usually below 1W/m K, of the reactor bed of general adsorption systems, expanded graphite block was adapted as the support of Na$_2$S salt. Expanded graphite blocks had thermal conductivity values of 20~80W/mK with respect to 100~400kg/㎥ of block bulk density. Permeability values of expanded graphite blocks were 10$^{-13}$ ~ 10$^{-14}$ $m^2$ with respect to 100~300kg/㎥ of block bulk density showing highly decreasing values of permeability, below 10$^{-l4}$$m^2$, in the range of above 150kg/㎥ of block bulk density.y.

  • PDF