• Title/Summary/Keyword: Water Vapor Pressure

Search Result 422, Processing Time 0.033 seconds

Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants (목본식물 형성층 전기저항에 영향을 주는 환경 요인)

  • Kim, Dong-Uk;Kim, Min-Soo;Lee, Bu-Yong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

Improvement of Soft Ground using Electric Heating Equipment (전기가열장치를 이용한 연약지반개량)

  • Han, Heuisoo;Im, Eunsang;Lee, Kumsung;Chang, Donghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.5-12
    • /
    • 2014
  • In this study, we developed the electric heating equipment and applied for soft ground improvement. The developed heat pipe is 4 m-length and consumes 1 kW/m, which is consisted of Ni-Cr wire. It was installed in 3.5~4.5 m below ground surface and heated for 96 hours (48 hours, 2 times). The temperature variation and vapor pressure caused by electric heating was measured by the thermometer and pressure gauge which were installed in the ground (5.0 m), and the tip resistances were measured by static electronic piezo-cone penetration test (CPT). As the results of experiments, 2-order polynomial curve was shown to adjust the variation of tip resistance and the temperature distribution with the horizontal distance from electric heater, whose R2 value is close to 1. In addition, in-situ pore-water pressure and water content was decreased.

Applicability evaluation of aerodynamic approaches for evaporation estimation using pan evaporation data (증발접시 증발량자료를 이용한 공기동력학적 증발량 산정 방법의 적용성 평가)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.11
    • /
    • pp.781-793
    • /
    • 2017
  • In this study, applicabilities of aerodynamic approaches for the estimation of pan evaporation were evaluated on 56 study stations in South Korea. To accomplish this study purpose, previous researchers' evaporation estimation equations based on aerodynamic approaches were grouped into seven generalized evaporation models. Furthermore, four multiple linear regression (MLR) models were developed and tested. The independent variables of MLR models are meteorological variables such as wind speed, vapor pressure deficit, air temperature, and atmospheric pressure. These meteorological variables are required for the application of aerodynamic approaches. In order to consider the effect of autocorrelation, MLR models were developed after differencing variables. The applicability of MLR models with differenced variables was compared with that of MLR models with undifferenced variables and the comparison results showed no significant difference between the two methods. The study results have indicated that there is strong correlation between estimated pan evaporation (using aerodynamic models and MLR models) and measured pan evaporation. However, pan evaporation are overestimated during August, September, October, November, and December. Most of meteorological variables that are used for MLR models show statistical significance in the estimation of pan evaporation. Vapor pressure deficit was turned out to be the most significant meteorological variable. The second most significant variable was air temperature; wind speed was the third most significant variable, followed by atmospheric pressure.

Refinement of GRACE Gravity Model Including Earth's Mean Mass Variations (지구 평균 질량 변화를 포함한 GRACE 중력 모델 보정)

  • Seo, Ki-Weon;Eom, Jooyoung;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.35 no.7
    • /
    • pp.537-542
    • /
    • 2014
  • The Gravity Recovery and Climate Experiment (GRACE) has observed the Earth's mass redistribution mainly caused by the variations of groundwater, ice sheet, and sea level since its launch in April 2002. The global gravity model estimated by the GRACE observation is corrected by barometric pressure, and thus represents the change of Earth mass on the Earth's surface and below Earth's surface excluding air mass. However, the total air mass varies due to the water exchange between the Earth's surface and the atmosphere. As a result, the nominal GRACE gravity model should include the Earth's gravity spectrum associated with the total air mass variations, degree 0 and order 0 coefficients of spherical harmonics ($C_{00}$). Because the water vapor content varies mainly on a seasonal time scale, a change of $C_{00}$ (${\delta}C_{00}$) is particularly important to seasonal variations of sea level, and mass balance between northern and southern hemisphere. This result implies that ${\delta}C_{00}$ coefficients should be accounted for the examination of continental scale mass change possibly associated with the climate variations.

Manufacture of Control and Data Acquisition System of Centrifugal Thin Film Evaporator(Centri-Therm, CT-1B) by Computer (컴퓨터를 이용한 원심식 박막증발기의 제어 및 자료 수집 시스템의 제작)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Park, Moo-Hyun;Han, Bong-Ho;Bae, Tae-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.479-485
    • /
    • 1990
  • For the automation of a evaporation process, computer based evaporation system was built and applied to acquisition of the process variables with an centrifugal thin film evaporator(Centri-Therm, CT-1B). Controls of the process conditions were performed by computer system for pressure, feeding rate, steam, evaporation temperature and flow rate of cooling water. The data acquisitions were also performed by computer system for the changes in the concentration and temperature readings for steam, evaporation and cooling water at the both inlet and outlet. The control and the acquisition variables were collected through the interface device and analyzed by programs using the PASCAL language. To control the feeding rate during the concentration process, inverter was used. The cooling water for the vapor condensation was controlled by the valve controller and should be supplied with the flow rate of 125 kg/h. The maximum vapor condensation rate was 41.7kg/h at the feeding rate of 125 kg/h.

  • PDF

Accuracy Analysis of GPS-derived Precipitable Water Vapor According to Interpolation Methods of Meteorological Data (기상자료 보간 방법에 의한 GPS기반 가강수량 산출 정확도 분석)

  • Kim, Du-Sik;Won, Ji-Hye;Kim, Hye-In;Kim, Kyeong-Hui;Park, Kwan-Dong
    • Spatial Information Research
    • /
    • v.18 no.4
    • /
    • pp.33-41
    • /
    • 2010
  • Approximately 100 permanent GPS stations are currently operational in Korea. However, only 10 sites have their own weather sensors connected directly to the GPS receiver. Thus. calculation of meteorological data through interpolation of AWS data are needed to determine precipitable water vapors at a specific GPS station without a meteorological sensor. This study analyzed the accuracy of two meteorological data interpolation methods called reverse sea level correction and kriging. As a result, the root-mean square-error of reverse sea level correction were seven times more accurate in pressure and twice more accurate in temperature than the kriging method. For the analysis of PWV accuracy, we calculated GPS PWV during the summer season in :2008 by using GPS observation data and interpolated meteorological data by reverse sea level correction. And, we compared GPS PWV s based on interpolated meteorological data with those from radiosonde observations and GPS PWV s based on onsite GPS meteorological sensor measurements. As a result, the accuracy of GPS PWV s from our interpolated meteorological data was within the required operational accuracy of 3mm.

A Numerical study on the Moisture Transport of Concrete Tunnel Linings with the Sprayable Waterproofing Membrane (뿜칠 방수 멤브레인이 시공된 터널 라이닝의 수분이동에 관한 수치해석 연구)

  • Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho
    • Tunnel and Underground Space
    • /
    • v.26 no.3
    • /
    • pp.212-219
    • /
    • 2016
  • The sprayable waterproofing membrane is installed between shotcrete to provide crack bridging and hence prevent flow of liquid water as a waterproofing system. Because of its material characteristics, the sprayable membrane can be constructed at more complex structure than sheet membrane. The main component of the sprayable waterproofing membrane is a polymer-based material, therefore, moisture can migrate through sprayable waterproofing membrane materials by capillary and vapor diffusion mechanisms. The moisture transport mechanisms can have an influence on the degree of saturation and may influence the pore pressure and risk of freeze-thaw damage on concrete linings and membrane. In this study, long-term hygrothermal behavior was simulated with considering moisture transport and long-term effects on saturation of tunnel linings. From the simulation, due to water absorption and vapor transport properties of sprayable membrane, change of relative humidity and water content in tunnel lining can be evaluated.

Evaporation Theory for Reclaimed Clay (준설 점토 지반에서의 증발 이론 개발)

  • 이형주;이인모;이영남;성상규
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.55-64
    • /
    • 2003
  • Desiccation of a soil is basically the removal of water by evaporation, which is controlled by evaporativity and evaporability. Surface evaporation improves the trafficability which is essential for the access of construction equipment in the area reclaimed with soft clay. The existing traditional methods for evaluating evaporation can not account for the deformation of reclaimed soft soils during evaporation. Therefore, a theoretical model for predicting the rate of evaporation from the surface of a deformable material is proposed. The model is based on a system of equations for coupled heat and mass transfer in unsaturated soils. The modified pressure plate extractor test and glass desiccator test were carried out to obtain the soil-water characteristic curve for a deformable soil. The column drying test was conducted to investigate one dimensional water flow, heat flow and evaporation in the surface. A finite difference program was developed to solve the coupled nonlinear partial differential equations, which permit the study of water, vapor and heat flows in the deformable soil. Comparison between measured and simulated values shows a reasonably good matching between the two.

Multivariate Statistical Analysis Approach to Predict the Reactor Properties and the Product Quality of a Direct Esterification Reactor for PET Synthesis (다변량 통계분석법을 이용한 PET 중합공정 중 직접 에스테르화 반응기의 거동 및 생산제품 예측)

  • Kim Sung Young;Chung Chang Bock;Choi Soo Hyoung;Lee Bomsock;Lee Bomsock
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.6
    • /
    • pp.550-557
    • /
    • 2005
  • The multivariate statistical analysis methods, using both multiple linear regression(MLR) and partial least square(PLS), have been applied to predict the reactor properties and the product quality of a direct esterification reactor for polyethylene terephthalate(PET) synthesis. On the basis of the set of data including the flow rate of water vapor, the flow rate of EG vapor, the concentration of acid end groups of a product and other operating conditions such as temperature, pressure, reaction times and feed monomer mole ratio, two multi-variable analysis methods have been applied. Their regression and prediction abilities also have been compared. The prediction results are critically compared with the actual plant data and the other mathematical model based results in reliability. This paper shows that PLS method approach can be used for the reasonably accurate prediction of a product quality of a direct esterification reactor in PET synthesis process.

Removal Characteristics of Styrene Vapor in the Biofilter Packed with Loess/Polyurethane Composite Media (황토/폴리우레탄 복합담체를 충전한 Biofilter에서 기상 Styrene의 제거특성)

  • Kang Kyung-Ho;Kam Sang-Kyu;Lee Taek-Kwan;Lim Sang-Bin;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.14 no.11
    • /
    • pp.1027-1033
    • /
    • 2005
  • The treatment of styrene vapor was carried out using the biofilter packed with loess/polyurethane composite during continuous operation of 74 days. The microorganisms were adapted within 2-3 days under the experimental conditions of inlet concentration and empty bed contact time (EBCT). At 200 sec of EBCT, the removal efficiency of styrene was 100\% with 200 ppmv of inlet concentration, while $92\%$ with 400 ppmv of inlet concentration. The biofilter showed the stable removal efficiencies of over $74\%$ under the EBCT range from 300 to 75 sec at the 150 ppmv of inlet styrene concentration. The maximum capacity of styrene removal for the biofilter packed with loess/polyurethane was $29g/m^3/hr$. During continuous operation of 74 days, pH of the drain water changed slightly and the pressure drop through the biofilter column was below $45\;mmH_2O/m$.