• 제목/요약/키워드: Water Treatment Process

검색결과 2,488건 처리시간 0.036초

하수처리 공정시스템에서 유량제어기법의 활용에 관한 연구 (A Study on the applications of flow control methods in sewage treatment process system)

  • 정성윤;강선홍
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.597-604
    • /
    • 2016
  • This study was begun with the object of actively reflection the rapid technological advancements of the electronical control and mechanical control industries to sewage disposal methods. Or focuses on applying a flow control method that utilizes inverters and automatic valves to sewage treatment process systems. This study proposes that sewage treatment process systems architects must acquire a certain degree of technical skills in the areas of electrical and mechanical controls in order to raise the standard of completeness of sewage treatment process systems. And further emphasizes that there is required continuous research on automatics valves that are used in sewage treatment.

Model based control of filter run time on potable water treatment plant

  • Jusic, Suvada;Milasinovic, Zoran
    • Coupled systems mechanics
    • /
    • 제4권2호
    • /
    • pp.157-172
    • /
    • 2015
  • Control of potable water treatment plant (PWTP) is nowadays based on experience. The aim of this article is to show that model based control of treatment process is more efficient than process operation based on experience. Stimela environment is used for modeling of processes of potable water treatment. Application of the model was conducted on PWTP "Crkvice" in Zenica (BiH). This plant has used conventional rapid sand filters. By effective application of the model it is determined the optimal filter run time for different input turbidity of raw water. This results in the possibility of reducing the consumption of backwashing water, lower costs for its pumping and reducing the amount of coagulants. In the existing practice, based on experience, these benefits are not used.

고도정수처리(DAF) 정수장 전력설비 적정 설계를 위한 고조파 현장 측정 및 분석 (The diagnosis and analysis for the correct design of electrical system in water treatment plan(Dissolved Air FIotation Process))

  • 김동룡;김기태;한병옥;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.61-63
    • /
    • 2007
  • In these days there are many troubles - system data error, control malfunctions, cable overheating - in water treatment plant. Specially DAF(Dissolved Air Floation Process) plant has high frequency than previous water treatment process. DAF plant has diverse equipment, nonlinear loads for the precise control. But there is no sufficient overall study about harmonics condition of water treatment plant just taking a following partial action without a fundamental solution. On designing of power system, designer should have regard to harmonics condition, but there is no guide reflected harmonics condition on DAF plant This study says what is the result of guideless design about harmonics. With the result of diagnosis and analysis in DAF plant, economical efficiency and safety of plant will be upgraded in the next design.

  • PDF

천연조류제거제를 활용한 응집·부상 전처리공정의 기존 응집공정 대체 가능성 (Substitutability of coagulation process by pre-treatment of coagulation·flotation using natural algae coagulant)

  • 장여주;정진홍;임현만;장향연;김원재
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.39-50
    • /
    • 2017
  • In the coagulation/sedimentation (C/S) process of the water treatment process, the inflow of massive algal bloom causes many problems including fouling of filter media. This study was conducted to find out the way to remove the algae's harmful effects by addition of pre-treatment prior to C/S process. Many Jar-tests were conducted such as (1) ACF (Algae Coagulation Flotation) process using natural algae coagulant (Water $Health^{(R)}$), (2) ACF + C/S process and (3) C/S process with a variety of conditions using cultured algae. The average values of turbidity were (1) 0.42 NTU for ACF process, (2) 0.13 NTU for ACF + C/S process and (3) 0.25 NTU for C/S process. It was shown that the treatment efficiency of ACF process could get low turbidity results, and ACF + C/S process could achieve more efficient results than those of C/S process. Any negative effects of ACF process to the efficiency of C/S process were not observed in ACF + C/S process. In order to reduce the unfavorable effects of algae, it was found out that the introduction of ACF process in the forms of (1) ACF or (2) ACF + C/S could be one of the effective and alternative solutions.

Pilot Study Analysis of Three Different Processes in Drinking Water Treatment

  • Kim, Dae-Ho;Lee, Byoung-Ho
    • Environmental Engineering Research
    • /
    • 제16권4호
    • /
    • pp.237-242
    • /
    • 2011
  • In this study, three pilot-scale plants with the capacity 30 $m^3$/day were designed and set up to treat reservoir water for the production of drinking water. Three treatment processes were compared in the pilot testing: process 1 (coagulation- flocculation- sedimentationsand filtration- ozone- BAC); process 2 (coagulation- flocculation- sedimentation- microfiltration-ozone- BAC); and process 3 (coagulation- flocculation- sedimentation- sand filtration- GAC). The quality of water has been evaluated on the basis of selected parameters such as turbidity, color, consumption of $KMnO_4$, dissolved organic carbon (DOC), trihalomethane formation potential (THMFP), geosmin and 2-MIB. A detailed assessment of performance was carried out during a five months operation. Process 2 was found to have better removal efficiency of DOC, THMFP, geosmin and 2-MIB than process 1 and process 3 under identical conditions, although the removal rate of color was found to be the same in the three cases.

고도정수처리를 위한 HCPAC-MBR 공정에서의 소독부산물 저감에 관한 연구 (A Study on Removal of Disinfection By-products in High Concentration Powdered Activated Carbon Membrane Bio-reactor Process for Advanced Water Treatment)

  • 이송희;장성우;서규태
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.27-34
    • /
    • 2006
  • This study was conducted to evaluate the performance of a membrane bioreactor filled with high concentration of powdered activated carbon (HCPAC-MBR) to reduce DBPs at the drinking water treatment. The pilot system was installed after the rapid sand filtration process whose plant was the conventional treatment process. The removal efficiencies of DBPs were measured during pilot operation period of 2 years. HAA and THM removal rates could be maintained around 80~90% without any troubles and then tremendous reduction of HAA and THM reactivity were observed more than 52%. The average removal rate of HAA formation potential (FP) and THM formation potential (FP) were 70.5% and 67.6% respectively. It is clear that the PAC membrane bioreactor is highly applicable for advanced water treatment to control DBPs.

하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구 (Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant)

  • 김충곤;신현곤
    • 유기물자원화
    • /
    • 제20권3호
    • /
    • pp.52-59
    • /
    • 2012
  • 처리공정별 연계처리수질을 검토한 결과 생물학적처리만 거친 생물반응조 처리수의 경우 연계부하율이 $COD_{Mn}$의 경우 1.67%(설계수질 기준), 2.59%(운영수질 기준), T-P의 경우 3.69%(설계수질 기준), 7.67%(운영수질 기준)로 다소 높게 나타났으나 하수처리장 운영에 미치는 영향은 거의 없을 것으로 판단된다. 또한, 고도처리공정인 산화부상분리 처리수 및 생물여과 처리수의 경우 연계부하율은 1% 내외로 고도처리설비 설치 시 과대 설비설치의 우려가 있다. 따라서 S하수처리장의 경제성 및 안정적인 운영을 고려할 경우 생물학적처리인 생물반응조를 거친 처리수를 연계하는 것이 바람직할 것으로 판단된다.

소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선 (Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater)

  • 이재엽;제스민아터;김일호
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

분말활성탄(PAC)+막여과(MF) 조합공정에서 PAC의 영향 평가 (Assesment of Powdered Activated Carbon Effect on PAC+MF Hybrid Membrane Process)

  • 김병수;왕창근;임재림;김충환
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.517-522
    • /
    • 2008
  • This study aims at an assessment of the effectiveness of taste & odor removal and transmembrane pressure changes in a pilot membrane plant(500m3/day) by adding PAC to MF process, and at providing a basis for applying it to the advanced water treatment process. The transmembrane pressure showed, in low turbidity of raw water, a tendency to decrease when PAC was injected at the Flux of 1, $1.5m^3/m^2{\cdot}d$, while it increased in high Flux($1.5m^3/m^2{\cdot}d$) in high turbidity of raw water. in addtion, it is shown that the fouling could be reduced more when PAC is injected together with appropriate amount of coagulant, than when PAC is solely injected. Taste & Odor-causing 2-MIB may not be detected in membrane filtered water, if the amount of PAC injection is increased in accordance with the increasing concentration of 2-MIB. Hence, PAC injection, as a pre-treatment process in MF membrane filtering, is supposed to be a suitable process for reducing fouling as well as for improvement effectiveness of taste & odor treatment.

POTABLE WATER TREATMENT BY POLYACRYLAMIDE BASE FLOCCULANTS, COUPLED WITH AN INORGANIC COAGULANT

  • Bae, Young-Han;Kim, Hyung-Jun;Lee, Eun-Joo;Sung, Nak-Chang;Lee, Sung-Sik;Kim, Young-Han
    • Environmental Engineering Research
    • /
    • 제12권1호
    • /
    • pp.21-29
    • /
    • 2007
  • For this study, we polymerized polyacrylamide base flocculants (PAA) and tested their properties and settling efficiency as a treatment for potable water. The most common chemicals for potable water treatment in Korea are alum or PAC. However, due to various reasons (such as rainy season or algae), inorganic flocculants cannot be solely depended on to solve all the problems caused by the poor quality of inflow water. When PAA coupled with coagulants in a potable water purification process is used, the turbidity removal efficiency increases by a factor of three on a single chemical system using PAC (Raw water: 5.21 NTU; Treated PAA+PAC: 0.34 NTU; and, Treated PAC: 1.04 NTU). It is possible to offset the toxic effect of residual monomers in treated water using PAA, because the concentrations of residual acrylamide are less than 400 mg/L in the polymer itself and less than $0.04\;{\mu}g/L$ in the treated water base at a dosage of 0.1 mg/L. Therefore, PAAs may be a workable, and dependable, potable water treatment process for the high pollutant level of resource water.