• 제목/요약/키워드: Water Treatment Plant

검색결과 2,073건 처리시간 0.033초

덕산(德山) 정수장(淨水場)에서의 BAC Pilot plant에 관한 연구(硏究) (A study on the BAC pilot plant in the Duk-san water works)

  • 이상봉;김동윤;임정아;이원권
    • 상하수도학회지
    • /
    • 제9권2호
    • /
    • pp.97-107
    • /
    • 1995
  • Today a conventional water treatment system has many problems. The ozone/GAC process, sometimes termed Biological Activated Carbon(BAC), appeared to be effective for the removal of soluble organic matters in the drinking water. The water quality of Nak-dong river in Pusan, generally shows BDOC 30-40% and NBDOC 60-70%. The pilot plant installed at the Duk-san water works that was been largest treatability(1,650,000ton/day) in Pusan. A experimental water in the pilot plant made use of the water after sand-filteration. Following results are drawn from this study. Initial adsorption velocity($DOC/DOC_o/T$) in the pure adsorption of GAG had a 0.0225, it's velocity changed to 0.006 after ozone added and the optimum ozone dose ranged of $1.4-2.0mgO_3/L$. A experimental water in the pilot plant composed with humic material(78%). Humic material composed with humic acid(20%) and fulvic acid(56%), and it's rate changed to 18 and 50% respectively after ozone added. DOC constantly decreased in the EBCTs and removal efficieny in the 15min of EBCT was 45-50%. It showed the largest removal rate of BDOC in the EBCT 5 and among the season, characteristics of removal varied. The HPC distributed over $10^6-10^7CFU/cm^3$ in the bed depth and among the season, distribution of HPC were differential.

  • PDF

정수처리용 활성탄 공정의 적정 역세척 시점 선정을 위한 영향인자들 평가 (Evaluation of Influence Factors for Determination of Proper Backwashing Time of Biological Activated Carbon (BAC) Process in Drinking Water Treatment Process)

  • 김상구;박홍기;손희종;염훈식;류동춘
    • 한국환경과학회지
    • /
    • 제24권12호
    • /
    • pp.1551-1558
    • /
    • 2015
  • In Korea, many drinking water treatment plants (DWTPs) have introduced and are going to introduce biological activated carbon (BAC) process to treated dissolved organic matter (DOM) in water which are difficult to control by conventional water treatment processes. Even though more decade have passed since introduced BAC in Korea, most of BAC operating method was followed to the modified sand filter operating manuals. In case of BAC backwashing, many DWTPs set the periods of backwashing about 3~5 days. In this study, we have collected data to set the proper BAC backwashing periods from both pilot-plant and real DWTPs. We had measured heterotrophic plate count (HPC), turbidity, water temperature, dissolved organic carbon (DOC) and headloss from just after backwashing to the next backwashing time for two years. Considering water quality factors, the BAC run time from backwashing to the next backwashing could extend more 30 days without water quality deterioration if the head loss do not reach the limited level which depends on each BAC facilities' condition. It means the BAC treated water could be saved in the proportion of extended the backwashing period to the existing backwashing period.

Reuses Of Wash Water Effluents Of The Ion-Exchanger Units Of Water Demineralization Plant For Economic And Environmental Benefits

  • Miah, Raisuddin
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.799-806
    • /
    • 1995
  • In industrial field, a large volume of regenerants (acid and caustic soda) and their washing effluents are regularly disposed off from the water demineralization plant during regeneration of the ion-exchanger units. Of these waste effluents, a part of the wash water discharged from the single bed Anion and Mixed Bed units can be utilized at a certain stage of their washing cycles when its conductivity is fallen down and becomes considerably less than that of the input raw water. The main aim of this specific waste effluent utilization is to dilute the TDS concentration of the input raw water (fed into the single bed ion-exchanger units) by blending. The achievement is the increase of the longevity of the production cycles of the I.E. units along with the improvement of the production quality and decrease of the regeneration frequencies. As a result, regenerant consumption would be saved because of the reduction of ionic load in feed water which will ultimately reduce the water purification cost. At the same time, the environment pollution will also be protected to a considerable extent. This operational measure is quite effective and useful specially where high TDS water is demineralized only by single bed ion-exchangers. In such case, the water treatment plant is very often found to suffer from both production quality and quantity in addition to carrying out of random and restless regenerations. Proper reuses of the aforesaid wash water effluents of the Anion and MB units excellently minimizes the difficulties experienced in practice. This paper contains the utilities and techniques of reuses of the different kinds of waste effluents of the industrial water treatment plant in addition to the specific reuses of the post-regeneration wash waters of the Anion and MB ion-exchanger units.

  • PDF

정수처리장 내의 미세플라스틱의 유입 및 처리기술 현황에 관한 고찰 (A mini-review on microplastics in drinking water treatment processes)

  • 최병규;김지윤;최수훈
    • 상하수도학회지
    • /
    • 제34권5호
    • /
    • pp.357-371
    • /
    • 2020
  • Microplastics have become a rising issue in due to its detection in oceans, rivers, and tap water. Although a large number of studies have been conducted on the detection and quantification in various water bodies, the number of research conducted on the removal and treatment of microplastics are still comparatively low. In the current research, the inflow and removal of microplastics were investigated for various drinking water treatment plants around the world. Addition to the investigation of filed research, a survey was also conducted on the current research trend on microplastic removal for different treatment processes in the drinking water treatment plants. This includes the researches conducted on coagulation/flocculation, sedimentation, dissolved air flotation, sand filtration and disinfection processes. The survey indicated mechanisms of microplastic removal in each process followed by the removal characteristics under various conditions. Limitations of current researches were also mentioned, regarding the gap between the laboratory experimental conditions and field conditions of drinking water treatment plants. We hope that the current review will aid in the understanding of current research needs in the field of microplastic removal in drinking water treatment.

갑천 상류부의 수질오염 우려구간 수질특성 및 수질관리방안 (Characteristics and Management Plan of Water Quality at the Water Pollution Deterioration Area of the Upper Stream of Gapcheon)

  • 장유호;손봉호;저소웅;임봉수
    • 한국물환경학회지
    • /
    • 제35권5호
    • /
    • pp.399-408
    • /
    • 2019
  • The average annual water quality at Yongchon Bridge, Bonggok 2 Bridge, and Gasuwon Bridge in upstream of Gapcheon in 2018 was Ib grade (good) in organic matters, including BOD and TOC compared to the local environmental standard in Daejeon. However, their monthly changes for TOC partially exceeded the standard during the busy farming season at Bonggok 2 Bridge and Gasuwon Bridge. Although the annual average TP was within the standard, the monthly change at Bonggok 2 Bridge partially exceeded the standard. For Dugyecheon, the annual average water quality in 2018 at Umyeon-dong Bridge and Wonjeong Bridge, which are downstream of the Gyeryong public sewage treatment plant, exceeded the local environmental standard in BOD. COD was exceeded, and TP was within the standard. It seemed that the causes of deteriorated water quality downstream of Dugyecheon were discharges of agricultural water from agricultural land and effluent from the Gyeryong public sewage treatment plant. Assuming the pollution load of 100% based at the Mulangil point of the mainstream of Gapcheon, the ratio of BOD load and TOC load were as high as 58% and 47%, respectively. At the basin of Bonggok 2 Bridge and Mulangil, the loads downstream of Dugyecheon including the Gyeryong public sewage treatment plant were as high as 43% for TN and 56% for TP, respectively, indicating that Dugyecheon had a major impact on the water quality at the mainstream of Gapcheon.

국내정수장의 잔류염소농도에 대한 조사연구 (Statistical Analysis of Chlorine Residual in Korean Drinking Water)

  • 손진식;강효순
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.281-287
    • /
    • 2006
  • Maintaining adequate chlorine residual is crucial in water treatment facilities, Treatment technique, newly promulgated regulation, requires sufficient disinfection in order to control more resistant microorganisms such as Viruses and Giardia lamblia. Each water treatment plant should report various water qualities including chlorine residual and disinfection by-products, thus plenty of data has been generated. Even though statistical analysis using these data are forced to investigate the status and effect of water qualities in water facilities very few researches have been performed in korea. This study performed statistical analysis of chlorine residual during three years in Korean drinking water. The average chlorine residual concentrations were 0.701mg/L, 0.738mg/L, 0.763mg/L in 2002, 2003, 2004, respectively. Monthly variations of chlorine residual was not significant. ANOVA result showed that yearly variance of chlorine residual is different in only less than $5000m^3/day$ of water treatment capacity. The statistical analysis can help government to establish new regulation with scientific basis.

탈수(脫水) 및 건조기법(乾燥技法)을 이용한 정수장(淨水場) 슬러지 감량화(減量化) (Sludge Minimization by Using Dewater and Thermal Treatment in the Water Treatment Plant)

  • 전항배;김영한;김량
    • 유기물자원화
    • /
    • 제2권1호
    • /
    • pp.87-98
    • /
    • 1994
  • 슬러지 발생량은 정수처리공정에서 부터 슬러지 농축 및 탈수에 이르는 과정을 최적화하므로써 감량화할 수 있다. 본 논문에서는 탈수 및 건조기법에 의하여 정수처리공정에서 발생하는 슬러지의 함수율을 낮추어 슬러지 발생량을 줄이는 방법에 대하여 연구하였다. 탈수효율향상을 위한 polymer 투입량 및 교반조건등을 최적화하고, 온도에 따른 슬러지의 중량변화에 대하여 관찰하였다. 탈수효율은 polymer의 종류보다 교반강도에 의한 영향이 크고, pH의 영향도 큰 것으로 나타났다. 최적 polymer 주입농도는 1.5mg-polymer/g-TSS이었고, pH가 약산성이나 약알카리성 조건에서 탈수효율이 양호한 것으로 나타났다. 교반강도는 낮을수록(10,000ses-1이하) 효율이 향상되었고, 속도구배(G)보다 GT값이 중요한 영향인자인 것으로 나타났다. 자유수의 건조는 $100^{\circ}C$ 전후, 화학적 결함수는 $300^{\circ}C$ 근방에서 증발하며, 유기물질은 약 $300-600^{\circ}C$ 구간에서 산화되어 증발하는 것으로 나타났다. 취수원 수질에 따라 강열감량은 약 15-40%로 나타났으며, 화학적 결합수에 의한 감량이 약 10-20%, 유기물질에 의한 감량이 약 4-20%인 것으로 나타났다.

  • PDF

하수처리시설 신설에 따른 QUAL2E모델에 의한 만경수계 수질예측 (Water Quality Prediction of the Mankyung Water Shed according to Construction of New Sewage Treatment Facilities)

  • 정팔진;현미희;정진필
    • 한국물환경학회지
    • /
    • 제26권2호
    • /
    • pp.200-207
    • /
    • 2010
  • The sewage treatment plants to be built to improve the water quality of the Mankyung River will total 11, of which combined capacity will reach $39,850m^3/day$, and saying in detail, 5 at Gunsan city, 2 at Iksan city, 1 at Kimje city and 3 at Wanju gun, The scenario for water quality improvement was developed, considering the conditions of plant operation ratio and the accomplishment of the water quality target (BOD 4.4 mg/L, T-P 0.356 mg/L) at the end of the watershed of Mankyung B was predicted, making use of QUAL2E model. As a result of prediction using QUAL2E model based on scenarios with 70% and 100% of operation ratio, respectively, at 11 plants in 2010, the water quality at the watershed of Mankyung B was estimated at 4.322 mg/L which was lower than the target of BOD 4.4 mg/L, indicating the target water quality was achieved, when it comes to 70% of operation ratio, But in case of T-P, it was estimated at 0.565 mg/L, which was higher than the target. When it comes to 100% of operation ratio, T-P also was 0.563 mg/L which exceeded the target, 0.356 mg/L. As indicated above, the effect of water quality improvement appeared very insignificant, which was attributable to the limit of small scale sewage treatment plant in total reduction capacity. Hence, the measures for additional reduction in a bid to achieve the target water quality of T-P at the designated location need to be taken, and the measures to build the Sewage treatment facilities at the place where the pollution is significantly caused by T-P appeared to be required as well.

CFD를 이용한 농축조 슬러지의 유출흐름특성 해석 (Analysis of the sludge thickening characteristics in the thickener using CFD Model)

  • 박노석;문용택;김병군;김홍석
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.