• 제목/요약/키워드: Water Treatment Plant

검색결과 2,070건 처리시간 0.025초

Effect of Deep Sea Water on Seed Germination, Photoperiod and Temperature on the Growth and Flowering of Buckwheat Species

  • Briatia, Xoxiong;Hong, Soon-Kwan;Sung, In-Je;Chang, Kwang-Jin;Park, Byoung-Jae;Park, Cheol-Ho
    • 한국자원식물학회지
    • /
    • 제25권3호
    • /
    • pp.323-328
    • /
    • 2012
  • This paper describes the potential use of deep sea water to stimulate seed germination in both common and Tartary buckwheat. Treatment of 10% deep sea water at $25^{\circ}C$ would slightly enhance germination of buckwheat seeds compared to non-DSW treatment and other temperature. In this study, the significant effects of photoperiod and temperature on seedling growth were also found in the HL treatment for the number of leaf, plant height, and plant fresh weight and LL treatment for root length and leaf size. Common buckwheat (Suwon No.1) showed higher rate (93%) of flowering plants in the HS and LL (93% of flowering rates) than those revealed in the HS and LS treatment, while the low percentage(67%) of plant flowering plants was shown in the LS treatment. All plants (100%) of a Korean landrace, Ahndong-jaerae showed flowers in the HS and LS treatment. HL and LL treatment status did not occur in the plant's flowering. Any Tartary buckwheat (KW45) plant did not yet flowered when it was 21 days-old.

고도정수처리(DAF) 정수장 전력설비 적정 설계를 위한 고조파 현장 측정 및 분석 (The diagnosis and analysis for the correct design of electrical system in water treatment plan(Dissolved Air FIotation Process))

  • 김동룡;김기태;한병옥;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.61-63
    • /
    • 2007
  • In these days there are many troubles - system data error, control malfunctions, cable overheating - in water treatment plant. Specially DAF(Dissolved Air Floation Process) plant has high frequency than previous water treatment process. DAF plant has diverse equipment, nonlinear loads for the precise control. But there is no sufficient overall study about harmonics condition of water treatment plant just taking a following partial action without a fundamental solution. On designing of power system, designer should have regard to harmonics condition, but there is no guide reflected harmonics condition on DAF plant This study says what is the result of guideless design about harmonics. With the result of diagnosis and analysis in DAF plant, economical efficiency and safety of plant will be upgraded in the next design.

  • PDF

Comparative performance evaluation of two UF pilot plants at the Alto da Boa Vista WTP (São Paulo, Brazil)

  • Oliveira, T.F.;Mierzwa, J.C.
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.175-185
    • /
    • 2011
  • Ultrafiltration is an emerging technology for drinking water treatment because it produces better water quality as compared with conventional treatment systems. More recently, the combination of UF technology with other processes in order to improve its performance has been observed. These associations aim to maximize the contaminants removal and reduce membrane fouling. The operational performance of contaminants removal and water production of two UF pilot plants was compared. The first plant (Guarapiranga) was fed with raw water and the second plant (ABV) with pre-treated water by the coagulation, flocculation and sedimentation processes at Alto da Boa Vista WTP (Sao Paulo, Brazil). Both units operated continuously for approximately 2,500 hours, from September/2009 to January/2010. The results showed that the ABV UF pilot plant was able to operate at higher specific fluxes (6.2 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$) than Guarapiranga (3.1 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$). However, the number of chemical cleanings conducted in both pilot units during the considered operation period was the same (4 chemical cleanings for each plant), which shows that the pre-treatment reduced the membrane fouling. The water quality at ABV for all the variables analyzed was better, but the feed water quality was also better due to pretreatment. The rejection values for the different contaminants were higher at Guarapiranga mainly because of a pollution load reduction after pre-treatment at ABV. Even with the better performance of the ABV UF pilot plant, it is necessary to take into consideration the complexity of the complete treatment system, and also the costs involved in the construction and operation of a full-scale treatment unit.

하수처리수를 이용한 소수력발전소 설계 및 성능예측 (Design and Performance Prediction of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant)

  • 이철형;박완순;김원경;김정연;채규정
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.78-83
    • /
    • 2013
  • A methodology to predict the output performance of small hydro power plant using treated effluent in waste water treatment plant has been studied. Existing waste water treatment plant located in Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. .Based on the models developed in this study, the hydrologic performance characteristics for SHP sites have been analyzed. The results show that the flow duration characteristics of small hydropower plant for waste water treatment plant have quite differences compared with small hydropower plant for the river. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in waste water treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed. It was found that the models developed in this study can be used to decide the design performance of small hydropower plant for waste water treatment plant effectively.

낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석 (Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin)

  • 조현경;김상민
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.202-209
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of a sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. Flow and water quality data, such as BOD, COD, SS, T-N, and T-P data, for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS, and T-P were correlated positively with the river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluents and downstream streams, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between the river flow rate and the water quality factors (COD, SS, TP) was high at river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석 (Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin)

  • 조현경;김상민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.493-493
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of the sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. The flow and water quality such as BOD, COD, SS, T-N, and T-P data for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS and T-P were correlated positively with river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluent and downstream stream, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between river flow rate and water quality factors (COD, SS, TP) was high for river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

  • PDF

정수처리공정에서 플록형성지의 효율향상 연구 (The Improvement of Flocculation Basin in Water Treatment Process)

  • 강창호;이현동;유재오
    • 한국수자원학회논문집
    • /
    • 제34권3호
    • /
    • pp.231-240
    • /
    • 2001
  • 본 연구에서는 포항시 양덕정수장에 tracer test를 이용한 pilot plant를 설치하여 기존 플록형성지에 대한 문제점을 도출하였다. 또한 플록형성지 각단 유출부의 단면을 여러 가지 형태로 변경시키면서 수리학적 평가를 실시하였고, 그 결과 플록형성지의 각단 유출부에 대한 최적 개량단면을 제시하였고, plant에 적용하여 현재 운전중에 있다. 또한 입자의 크기별 개수를 측정할 수 있는 particle counter를 이용하여 플록형성지 개량후의 효율을 평가하여 다음과 같은 결론을 얻었다. 체류시간에 관계없이 전체적으로 비슷한 흐름과 index 수치를 나타내므로 체류시간을 가능한 짧게 잡는 것이 바람직하다고 판단된다. 또한 양덕정수장의 플록형성지 개선공사후 기존의 플록이 깨어지는 문제가 개선되어 상당히 양호하게 운전되고있으며, tracer test를 이용한 수리학적 특성 실험방법은 플록지형성지 뿐만 아니라 기존 정수장의 단위공정에 대한 성능평가나 시설개선에 사용할 수 있으며, 신설정수정의 설계인자를 구하는데 유용하게 이용할 수 있다.

  • PDF

정유량 막여과 파울링 모델을 이용한 막여과 정수 플랜트 공정 진단 기법 (A process diagnosis method for membrane water treatment plant using a constant flux membrane fouling model)

  • 김수한
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.139-146
    • /
    • 2013
  • A process diagnosis method for membrane water treatment plant was developed using a constant flux membrane fouling model. This diagnosis method can be applied to a real-field membrane-based water treatment plant as an early alarming system for membrane fouling. The constant flux membrane fouling model was based on the simplest equation form to describe change in trans-membrane pressure (TMP) during the filtration cycle from a literature. The model was verified using a pilot-scale microfiltraton (MF) plant with two commercial MF membrane modules (72 m2 of membrane area). The predicted TMP data were produced using the model, where the modeling parameters were obtained by the least square method using the early plant data and modeling equations. The diagnosis was carried out by comparing the predicted TMP data (as baseline) and real plant data. As a result of the case study, the diagnsis method worked pretty well to predict the early points where fouling started to occur.

정수장운영관리사 직무분석에 관한 연구 (Job Analysis for the Development of Curriculum for Education and Training and Guidelines for Making Questions in Examinations of Water Treatment Plant Operator)

  • 구자건;박종성;오현제;최승일;허방련;위미경
    • 상하수도학회지
    • /
    • 제20권3호
    • /
    • pp.377-388
    • /
    • 2006
  • This paper is aimed to design for qualification structure and developing Vocational Education and Training Program of Water Treatment Plant Operator. Also job analysis was performed by the experts of education and related field though Developing A Curriculum(DACUM). The qualification structure and developing Vocational Education and Training Program of Water Treatment Plant Operator was designed and policy suggestions are made for the substantiality and activity to the government. This study is performed expert interview and job analysis The results are presented the summaries of job definitions, job models, areas of vocation activities, curriculum for education and training and guidelines for making questions in examinations.

정수 및 하수처리공정 중 침전지 부착조류 및 미생물 군집구조 해석 (Analysis of Attached Algae and Microbial Community Structure in Sedimentation Basin of Water and Wastewater Treatment Plant)

  • 임병란;안규홍;송경근;박유정;전대영
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.61-67
    • /
    • 2005
  • The objective of this study was to investigate community structure of attached algae and microbes in sedimentation basin of water and wastewater treatment plants by using respiratory quinone profile. There was an evident difference, in microbial community structure and attached algae species, between inclination plate settler and drainage canal in the sedimentation basin. The algae was composed of species in following order; Chlorophyceae>Bascillariophyceae>Cyanophyceae. The dominant quinone types of attached microorganisms in the wastewater treatment plant were plastoquinone (PQ)-9, vitamin(V)K-1 followed by UQ-8, but those for water treatment plant were VK-1, PQ-9 followed by UQ-8. These results suggests that nutrients, seasons and material of sedimentation basin have notable influence on composition of attached algae and microbial community structure in water and wastewater treatment plants.