• Title/Summary/Keyword: Water Tank Test

Search Result 388, Processing Time 0.026 seconds

Large Capacity Passive Flow Control Vortex Valve (대용량 피동형 유량제어 와류 밸브)

  • Choi, N. H.;Chu, I.-C.;Chung, C. H.;Cho, B. H.;Song, C.-H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.635-640
    • /
    • 2004
  • The present paper provides the design specifications and working principle of flow controlling vortex valve which will be adopted in a Korean next generation reactor (APR1400). The vortex valve is installed inside the pressurized safety injection tank of APR1400, and it passively controls the water discharge flowrate from the tank. In the present study, the performance of the vortex valve have been evaluated throughout the repeated experiments in the full-scale test facility called VAPER(VAlve Performance Evaluation Rig). Based on the experimental results, it is confirmed that the currently developed vortex valve satisfies the major performance requirements of APR1400 plant design in view of the peak discharge flowrate, pressure loss coefficient, and total discharge duration time. To achieve the highest quality of the experimental results, a quality assurance program for vortex valve tests has been strictly applied.

  • PDF

The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling (냉매 과냉각을 이용한 열펌프 시스템의 성능 특성)

  • Roh, Geon-Sang;Son, Chan-Ghyo
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.4
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

High-Rate Nitrogen Removal using a Submerged Module of Sulfur-Utilizing Denitrification (침지형 황 탈질 모듈을 이용한 고속의 질소제거)

  • Moon, Jin-Young;Hwang, Yong-Woo;Ga, Mi-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.429-437
    • /
    • 2007
  • This study aims to develop a sulfur-using denitrification process which is possible a renovation to advanced treatment plant submerging a simple module in activated sludge aeration tank. At first, the impact factor of sulfur-using denitrification was appreciated by the batch test. Secondly, reflecting a dissolved oxygen effect of sulfur-using denitrification that was confirmed by the batch test, in a continuous nitrification/sulfur-using denitrification, high-rate nitrogen removal reaction was induced at optimum condition controlling DO concentration according to phases. Also, inside and outside of sulfur-using denitrification module was covered with microfilter and the module was considered as an alternative of clarifier. Result of batch test for sulfur-using denitrification, $NO_2{^-}N$ was lower for consumption of alkalinity and sulfur than that of $NO_3{^-}-N$. These results revealed the accordance of theoretical prediction. In continuous nitrification/sulfur-using denitrification experiment, actual wastewater was used as a influent, and influent nitrogen loading rates were increased 0.04, 0.07, 0.11, $0.14kg\;N/m^3-day$ by changing hydraulic retention times. At this time, nitrogen loading rates of packed sulfur were increased 0.23, 0.46, 0.69, $0.93kg\;N/m^3-day$. As a result, nitrification efficiency was about 100% and denitrification efficiency was 93, 81, 79, 72%. Accordingly, nitrogen removal was a high-rate. Also the module of sulfur-using denitrification covered with microfilter did not make a fouling phenomena according to increased flux. And the module was achieved effluent suspended solids of below 10 mg/L without a clarifier. In conclusion, it is possible a renovation to advanced treatment plant submerging a simple module packed sulfur in activated sludge aeration tank of traditional facilities. And the plant used the module packed sulfur is expected as a effective facilities of high-rate and the smallest.

Nondestructive Evaluation of Thermal Shock Damage for Alumina Ceramics (알루미나 세라믹에 대한 열충격 손상의 비파괴적 평가)

  • Lee, Jun-Hyeon;Lee, Jin-Gyeong;Song, Sang-Heon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.8
    • /
    • pp.1189-1196
    • /
    • 2001
  • The objective of this paper is to investigate the applicability of acoustic emission(AE) technique to monitor the progress of the thermal shock damage on alumina ceramic. For this purpose, alumina ceramic specimen was heated in the furnace and then was quenched in the water tank. When the specimen was quenched in the water tank, complex AE signals due to the initiation of micro-cracks and boiling effect were generated by the progress of thermal shock damage. These mixed AE signals have to be classified for monitoring the degree of the thermal shock damage of alumina ceramics. In this paper, the mixed AE signals generated from both the boiling effect and the crack initiation under thermal shock test was analyzed. The characteristics of AE signals were also discussed by considering the variation of bending strength and Yongs modulus of specimens.

A study on the stability of a crab trap fishing boat with water tank experiment (수조 실험에 의한 게 통발 어선의 복원성에 관한 연구)

  • Lee, A-Reum;Kang, Il-Kwon;Jo, Hyo-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.4
    • /
    • pp.267-275
    • /
    • 2009
  • According to the recent statistics of marine casualties in Korea, fishing boats are more likely to be ended in the casualties, and small fishing boats especially cause much more accidents in sinking and capsizing than any other big vessels. These casualties were mainly produced from the ignorance on the lack of own ship stability. From this view, this study aims to analyze the characteristics of stability on the crab trap fishing boat receiving transverse wave by means of carrying out the water tank test. The rolling angle of the model ship was affected largely with the displacement and the wave period of it, and the trends were shown that the magnitude of the angle was proportional to the displacement, but inversely to the wave period. And the wave height had effect on the rolling angle just in the specific range of the wave period. The force of steady wind didn't have influence on the rolling variation significantly.

Preference of adult top shell (Batillus cornutus) on specific marine algae in the coastal waters of Jeju Island (제주도산 소라 (Batillus cornutus) 성패의 특정 해조류에 대한 선호도)

  • Yoo, Joon-Taek;Oh, Bong-Se;Chang, Dae-Soo
    • The Korean Journal of Malacology
    • /
    • v.27 no.4
    • /
    • pp.299-306
    • /
    • 2011
  • This paper examines relation between growth of adult top shell and their selectivity over different marine algae. For the study the top shell density and the algal species in different depth were surveyed by SCUBA. To test selectivity over different types of algae, five algal species including Ecklonia cava, Undaria pinnatifida, Ulva spp, Gelidium amansii and Sargassum spp were provided to top shells in indoor water tank condition. In the field survey, the wet weight of Ecklonia cava was significantly (r = 0.612, p < 0.05) correlated to the shell length (SL) of top shell. In the indoor water tank experiment conducted over 12 hours after sunrise, adult top shell (SL > SL 4.5 cm) tended to select Ecklonia cava and Undaria pinnatifida, which are common and abundant algal in the subtidal waters in Jeju Island. Our field survey and the indoor experiment suggest that E. cava and U. pinnatifida could be food preferred by adult top shell in its habitat.

A Study on Integrated OWC System within Turbine Effects

  • Liu, Zhen;Hyun, Beom-Soo;Hong, Key-Yong;Lee, Young-Yeon;Jin, Ji-Yuan
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • Oscillating Water Column is one of the most widely used converting systems all over the world. The operating performance is influenced by the efficiencies of the two converting stages in the OWC chamber-turbine integrated system. In order to study the effects of the pressure drop induced by the air turbine, the experiments using the impulse turbine and the orifice device are carried out in the wave simulator test rig. The numerical simulation utilizing the orifice and porous media modules is calculated and validated by the corresponding experimental data. The numerical wave tank based on the two-phase VOF model embedded with the above modules is employed to investigate the wave elevation, pressure variation inside the chamber and the air flow velocity in the duct. The effects of the air turbine on the integrated system and interaction among the wave elevation, pressure and air flow velocities variations are investigated, which demonstrates that the present numerical model are more accurate to be employed.

Distributed control system architecture for deep submergence rescue vehicles

  • Sun, Yushan;Ran, Xiangrui;Zhang, Guocheng;Wu, Fanyu;Du, Chengrong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.274-284
    • /
    • 2019
  • The control architectures of Chuan Suo (CS) deep submergence rescue vehicle are introduced. The hardware and software architectures are also discussed. The hardware part adopts a distributed control system composed of surface and underwater nodes. A computer is used as a surface control machine. Underwater equipment is based on a multi-board-embedded industrial computer with PC104 BUS, which contains IO, A/D, D/A, eight-channel serial, and power boards. The hardware and software parts complete data transmission through optical fibers. The software part involves an IPC of embedded Vxworks real-time operating system, upon which the operation of I/O, A/D, and D/A boards and serial ports is based on; this setup improves the real-time manipulation. The information flow is controlled by the software part, and the thrust distribution is introduced. A submergence vehicle heeling control method based on ballast water tank regulation is introduced to meet the special heeling requirements of the submergence rescue vehicle during docking. Finally, the feasibility and reliability of the entire system are verified by a pool test.

Blowdown and Condensation (B&C) Loop for Development of Reactor Depressurization System

  • Park, Choon K.;Chul H. Song;Soon Y. Won;Seok Cho;Moon K. Chung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.61-66
    • /
    • 1996
  • High pressure. high temperature steam/water blowdown test loop has been constructed. The loop simulates a pressurizer. depressurizalion system and In-Containment Refueling Water Storage Tank (IRWST) with full pressure and temperature conditions. and will be used to generate data for development of an optimal sparser as well as for design of safety/automatic depressurization system. In addition. experiments for reactor safety and pressurizer thermal hydraulics are scheduled. In this paper. general description of the Blowdown and Condensation (B&C) Loop will be given together with the test program.

  • PDF

A Study on the Mix Design of the Self-Compaction Concrete for the LNG Tank (LNG Tank용 자기충전 콘크리트의 배합설계에 관한 연구)

  • Kim, Dong-Seok;Park, Sang-Joon;Won, Cheol;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.135-138
    • /
    • 2003
  • The purpose of this study was to design the self-compaction concrete mixture, having not only high strength but also compensation of shrinkage without thermal crack under 4 sides outer restraint of the member. In the experimental mix, replacement ratio of limestone Powder, CSA expansive additives, and unit water were selected as parameters, using portland blast-furnace slag cement. And, bleeding test, expansibility test, hydration heat analysis were performed. As a results, when 35% of limestone Powder, 6% CSA expansive additives are replaced at unit water 175kg/$\textrm{m}^3$, demanded performances of fresh and hardened self-compaction concrete are accomplished.