• Title/Summary/Keyword: Water Tank

Search Result 2,116, Processing Time 0.033 seconds

Analytical Study on the Performance Characteristics of an Instant Cooling Type Water Purifier with the Design Parameters of the Cooling Tank (순간냉각식 정수기 냉수조의 설계변수에 따른 성능 특성에 관한 해석적 연구)

  • Jeon, Yong-Seok;Park, Hong-Hee;Lee, Joo-Seoung;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.545-552
    • /
    • 2012
  • The objective of this study is to analyze the effect on the energy consumption of an instant cooling type water purifier by the design parameters of the cooling tank. Initially, the simulation program was developed and verified. The simulation results showed that the energy consumption was reduced by replacing the shape of the cooling tank from a rectangular to a cube, increasing the evaporator length, decreasing the volume of the cooling tank, and increasing the performance of the insulator. The order of the effect magnitude on the energy consumption was as follows; volume of the cooling tank, conductivity and thickness of the insulator, shape of the cooling tank, length of the evaporator, and length of the water tube.

A study on the drinking water for some primary school in Seoul (서울지역 일부 국민학교의 음용수 이용에 관한 연구)

  • Lee, Won-Myo;Bang, Hyeong-Ae
    • Journal of the Korean Dietetic Association
    • /
    • v.1 no.1
    • /
    • pp.31-42
    • /
    • 1995
  • The aims of this study are to enhance the students' knowledge of the drinking water and its reliability by investigating drinking water situation and the degree of students' knowledge on the drinking water. The results are as follows 1. Status and drinking behavior about school drinking water (1) 97.53% of the schools are using the tap water as the resource of drinking water (2) 46 schools are in possession of water tank and 18 schools of them are using the water tank as the resource of drinking water. The cleaning and sanitization of the tank are carried out once in a year with hypochloronatrium by the low-level officials, nurse teachers, and dietitian. 2. The degree of students' knowledge about drinking water (i) This survey represent that students favor the spring water best and think the tap water worst for drinking. (2) 83% of the students think that the tap water is polluted and these conception are formed mostly by the mass communication. 80% of boys and 90% of girls answered they don't drink plain tap water.

  • PDF

The Effect of a Manifold in a Storage Tank Applied to a Solar Combisystem (태양열 콤비시스템의 축열조에 적용되는 분배기의 효과)

  • Son, Hyo Seok;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.7
    • /
    • pp.322-328
    • /
    • 2014
  • Return piping is used in a solar combi-system for heating and hot water supply. When the temperature of the lower side of a storage tank is low due to hot water usage, the returned hot water after heating is mixed with the lower side cold water of the tank, and the useful energy is reduced. We studied the degree of thermal stratification in the tank, using either a diffuser or a manifold to prevent mixing. Using the diffuser, mixing starts from the bottom of the storage tank. On the other hand, the manifold has the marked effect of preventing mixing. As a result of experiments with changing the diameter and number of holes in the manifold, the optimum condition is 8.5 mm diameter and 96 holes, under the condition of 0.3 lpm.

Level control of single water tank systems using Fuzzy-PID technique

  • Lee, Yun-Hyung;Jin, Gang-Gyoo;So, Myung-Ok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.550-556
    • /
    • 2014
  • In this study, for the control of a single water tank system, a fuzzy-PID controller design technique based on a fuzzy model is investigated. For this purpose, a water tank system is linearized as a number of submodels depending on the operating point, and a fuzzy model is obtained by fuzzy combining. Each submodel is approximated as a first order time delay model, and a PID controller is designed using several existing tuning techniques. Then, through the fuzzy combination of this controller using the same method as that of the fuzzy model, a fuzzy-PID controller is designed. For the proposed technique, a simulation is performed using the fuzzy model of a water tank system, and the validity is examined by comparing its performance with that of a PID controller.

Convergence Study on Flow Characteristic due to the Configuration of Water Tank (물탱크의 형상에 따른 유동 특성에 관한 융합 연구)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.6
    • /
    • pp.185-190
    • /
    • 2019
  • In this study, the flow characteristics happening inside water tank due to the configuration of various water tank were analyzed by using a computation fluid dynamics program, ANSYS CFX. This study also examined which model was most efficient at the flow by changing the flow conditions of the inlet and outlet due to the configuration of various tank. Same material was applied to models A, B and C. As the result of flow analysis, it was shown that model B had the best flow and model C had the highest pressure applied to the flow. So, though the water tank has the same material according to the configuration of product, the velocity and pressure of flow become different. Therefore, it is thought to develop the tank good for the fluid flow due to the product configuration through this flow analysis result. On the basis of this study result, the esthetic sense can be shown as the analysis data of flow due to the configuration of fluid tank are grafted onto the real life.

Development of a measurement device of water level at the bottom of fuel tanks using an optical cable sensor

  • Kim, Hiesik;Lee, Byoungsuk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.95.1-95
    • /
    • 2002
  • <1. New level meter inside the fuel tank> Ultrasound level sensors are widely applied as level meters of liquid tank. Measurement instrument of level between water and fuel is developed. Since the fuel is inflammable, the sensor system doesn't allow to include any electric circuit inside the fuel tank. The optical cable sensor can satisfy this explosive condition. The measurement method with ultrasonic sensor is attached on the tank wall or tank manhole lid. The pressure sensor can't be applied inside the gasoline fuel tank. An ultra-sonic sensor doesn't detect a enough signal reflected from water level deep under gasoline fuel. The pressure sensor is difficult to measure the height o...

  • PDF

2D Finite element analysis of rectangular water tank with separator wall using direct coupling

  • Mandal, Kalyan Kumar;Maity, Damodar
    • Coupled systems mechanics
    • /
    • v.4 no.4
    • /
    • pp.317-336
    • /
    • 2015
  • The present paper deals with the analysis of water tank with elastic separator wall. Both fluid and structure are discretized and modeled by eight node-elements. In the governing equations, pressure for the fluid domain and displacement for the separator wall are considered as nodal variables. A method namely, direct coupled for the analysis of water tank has been carried out in this study. In direct coupled approach, the solution of the fluid-structure system is accomplished by considering these as a single system. The hydrodynamic pressure on tank wall is presented for different lengths of tank. The results show that the magnitude of hydrodynamic pressure is quite large when the distances between the separator wall and tank wall are relatively closer and this is due to higher rotating tendency of fluid and the higher sloshed displacement at free surface.

Development of Wireless Integrated System for Managing Water Tank (저수조 무선 통합 관리 시스템 개발)

  • Jung Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.6
    • /
    • pp.16-25
    • /
    • 2006
  • Most water tanks operating have been managed by people's five senses. A human material resource have been wasted awfully at this. In the present study, we suggest the wireless integrated system for managing water tank of reducing the wastage human resources and on-line real time managing efforts of water tanks. Water level sensor works the pump sending the data from water tank control to the wireless control on sensing water level. At this time, every kind data which happens in the water tank transmits the line transmission modem. Data to be received from the line transmission modem is stored at the database after we record the logs by each hour. We display the result to the web pages, after checking the pump motion, the pump error, the water level, the solar battery error, the chemicals, and the telephone line to the foundation data to be saved. Furthermore, this paper suggests empirical applications of the proposed wireless integrated system for managing water tank in order to verify its feasibility.

  • PDF

The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank (응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리)

  • Kim, Dong-Ha;Lee, Soo-Young;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

Self-healing and leakage performance of cracks in the wall of a reinforced concrete water tank

  • Gao, Lin;Wang, Mingzhen;Guo, Endong;Sun, Yazhen
    • Earthquakes and Structures
    • /
    • v.16 no.6
    • /
    • pp.727-741
    • /
    • 2019
  • A reinforced concrete water tank is a typical functional liquid storage structure and cracks are the greatest threat to the liquid storage structure. Tanks are readily cracked due to seismic activity, thereby leading to the leakage of the stored liquid and a loss of function. In order to study the effect of cracks on liquid storage tanks, self-healing and leakage tests for bending cracks and through cracks in the walls of a reinforced concrete water tank were conducted. Material performance tests were also performed. The self-healing performance of bending cracks in a lentic environment and through cracks in a lotic environment were tested, thereby the self-healing width of bending micro-cracks in the lentic environment in the short term were determined. The through cracks had the capacity for self-healing in the lotic environment was found. The leakage characteristics of the bending cracks and through cracks were tested with the actual water head on the crack. The effects on liquid leakage of the width of bending cracks, the depth of the compression zone, and the acting head were determined. The relationships between the leakage rate and time with the height of the water head were analyzed. Based on the tests, the relationships between the crack characteristics and self-healing as well as the leakage were obtained. Thereby the references for water tank structure design and grading earthquake damage were provided.