• Title/Summary/Keyword: Water Supply and Sewage

Search Result 126, Processing Time 0.04 seconds

Classification and Installation Cases of Small Hydraulic Turbine (소수력용 수차의 종류 및 설치 예)

  • Choi, Young-Do;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.503-506
    • /
    • 2006
  • Recently, small hydropower attracts attention because of its clean renewable and abundant energy resources to develop. However, suitable turbine type is not normalized yet in the range of small hydropower and it is necessary to study for the effect ive turbine type. Moreover, relatively high manufacturing cost by the complex structure of the turbine is the highest barrier for developing the small hydropower turbine. Therefore, this study is trying not only, to classify the type of current operating turbines installed in the domestic power plants and turbines supplied in Japan by Japanese manufacturer but also, to examine the practical turbine type and installation site to extract the small hydropower energy effectively.

  • PDF

Analysis of project-level elements of a smart city: A case study

  • Kisi, Krishna P.;Bhattarai, Sushmit Sharma
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1001-1008
    • /
    • 2022
  • As a part of the Smart Cities Mission, the Government of India in 2015 embarked upon the development of 100 existing cities as smart cities. In this study, the authors selected Ahmedabad city as the smart city development in India and presented project-level elements of the city based on the secondary data availability. At first, the authors focused on peer-reviewed articles, policy documents, and technical reports. Next, the authors collected the secondary data of project-level elements of the Ahmedabad city from the years 2015 to 2019. The findings show no significant improvement in the sewage system and waste collection as compared to the level of investment made in these sectors. The study showed that the water supply system outperformed revenue generation based on the government investment made in that sector. As a lesson learned, these findings indicate that significant improvement should be addressed in sewage management and waste collection. These study findings could help government officials, investors, developers, and city planners in making the appropriate decision before and during smart city execution. The lesson learned from this study could be used as a reference to improve revenue during the future smart city implication.

  • PDF

Groundwater Investigation of the Cheonggyecheon Watershed Area

  • Choi, Doo-Hyung;Yang, Jea-Ha;Jun, Sung-Chun;Lee, Kang-Keun;Kim, Yoon-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.323-327
    • /
    • 2004
  • The groundwater system of the Cheonggyecheon watershed is very complicated because it is influenced by many factors such as pumping out, groundwater leakages into subway stations, civil use of groundwater, and leaking water from water supply and sewage lines. So the characterization and evaluation of tile groundwater flow and contaminant transport in the Cheonggyecheon water system is quite a difficult task. The purpose of this study is to analyze of the influence to the 'groundwater' below the Cheonggyecheon watershed by the 'surface water' on the Cheonggyecheon stream after the restoration. We have so far collected groundwater quality data, hydrogeologic aquifer parameters, and tile amount of leakages into subway stations and its influence on the groundwater system of the Cheonggyecheon. Results show that groundwater level was influenced by the direction and depth of a 녀bway station. This study will continue to monitor groundwater quality, a water level fluctuation relation between rainfall and groundwater recharge for further investigation of the groundwater flow system in Cheonggyecheon.

  • PDF

Groundwater system Investigation of the Cheonggyecheon watershed Area

  • Choi, Doo-Hyung;Yang, Jae-Ha;Jun, Seong-Chun;Lee, Kang-Keun;Kim, Yoon-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.326-329
    • /
    • 2004
  • The groundwater system of the Cheonggyecheon watershed is very complicated because it is influenced by many factors such as pumping out, groundwater leakages into subway stations, civil use of groundwater, and leaking water from water supply and sewage lines. So the characterization and evaluation of the groundwater flow and contaminant transport in the Cheonggyecheon water system is quite a difficult task. The purpose of this study is to analyze the influence on the‘groundwater’ below the Cheonggyecheon watershed by the‘maintenance water’on the Cheonggyecheon stream after the restoration. We have so far collected groundwater quality data, hydrogeologic aquifer parameters, and the amount of leakages into subway stations and its influence on the groundwater system. Results show that groundwater level was influenced by the direction and depth of subway tunnel. This study will continue to monitor groundwater quality, a water level fluctuation relation between rainfall and groundwater recharge for further investigation of the groundwater flow system in the Cheonggyecheon watershed.

  • PDF

Recycling of a discarded septic tank as a rainwater management system and it's economic feasibility analysis (폐정화조를 재활용한 다목적 빗물관리시스템 구상 및 경제성 분석)

  • Kim, Mikyeong;Kwak, Donggeun;Han, Mooyoung;Yang, Jichung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.647-654
    • /
    • 2009
  • Since the end of the 1990s, sewer pipe improvement works have been going on: most septic tanks have been thrown away and discarded. These discarded septic tanks amounts up to 370,000 based on the project plan 2005-2008: it is a serious squander of nation's resources, a contaminating means that buries toxins under soil, and a cause of a expensive waste. Research on recycling of discarded septic tank as a new resource is in urgent need. This research suggests plans to recycle discarded septic tank as a rainwater management facility, solutions to water cycle recovery in the limelight, and economic analysis of the plan. In the case of a recycling discarded septic tank as a rainwater management facility will socially benefit to support economical adequacy, discard cost saving of septic tank and water supply and sewage cost reduction will come out. Consequently a rainwater management facility converted from a discarded septic tank leads to decentralization of the rainwater management system, which anticipates a positive effect on recovery of urban water cycle.

Development and Assessment of Specific and High Sensitivity Reverse Transcription Nested Polymerase Chain Reaction Method for the Detection of Aichivirus A Monitoring in Groundwater (지하수 중 Aichivirus A 모니터링을 위한 특이적 및 고감도 이중 역전사 중합효소연쇄반응 검출법 개발 및 평가)

  • Bae, Kyung Seon;Kim, Jin-Ho;Lee, Siwon;Lee, Jin-Young;You, Kyung-A
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.3
    • /
    • pp.190-198
    • /
    • 2021
  • Human Aichivirus (Aichivirus A; AiV-A) is a positive-sense single-strand RNA non-enveloped virus that has been detected worldwide in various water environments including sewage, river, surface, and ground over the past decade. To develop a method with excellent sensitivity and specificity for AiV-A diagnosis from water environments such as groundwater, a combination capable of reverse transcription (RT)-nested polymerase chain reaction (PCR) was developed based on existing reported and newly designed primers. A selective method was applied to evaluate domestic drinking groundwater samples. Thus, a procedure was devised to select and subsequently identify RT-nested PCR primer sets that can successfully detect and identify AiV-A from groundwater samples. The findings will contribute to developing a better monitoring system to detect AiV-A contamination in water environments such as groundwater.

Characteristics of Disinfection By-Products Formation in Chlorination of Principal Raw Waters for Drinking Water of Jeju Island, Korea

  • Oh, Sun-Mi;Park, Tae-Hyun;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1031-1041
    • /
    • 2012
  • This study was carried out to investigate the characteristics of disinfection by-products (DBPs-trihalomethanes (THMs), haloacetic acids (HAAs) and haloacetonitriles (HANs) formation in chlorination of principal raw waters used for drinking water on Jeju Island, Korea. The domestic water supply of other area and humic acid solution (HA) were used as a reference point. The effects of chlorine contact time, solution temperature and pH on DBPs formation potential (DBPFP) were investigated for raw waters. In addition, the effect of $Br^-$ was studied for HA. The DBPFP (THMFP, HAAFP and HANFP) were increased with increasing chlorine contact time. Comparing the individual DBPFPs for raw waters, they decreased in the order of HAAFP > THMFP ${\geq}$ HANFP. As the solution temperature was increased, the THMFP, HAAFP and HANFP increased. With increasing the solution pH, the THMFP was increased, but HAAFP and HANFP were decreased. With the addition of 0.3 mg/L $Br^-$ for HA, the DBPFP was increased and the major chemical species changed: from trichloromethane to dibromochloromethane and tribromomethane for THMs; from dichloroacetic acid and trichloroacetic acid to tribromoacetic acid for HAAs; and from dichloroacetonitrile to dibromoacetonitrile for HANs.

Numerical Study on Submersible Pumps with a Vortex Reduction Function (와류저감기능이 적용된 수중펌프에 관한 수치적 연구)

  • Ahn, Deog-Inn;Kim, Hong-gun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.83-92
    • /
    • 2019
  • A pump is considered to be submersible when a motor and a pump are integrated and operate while submerged in water. Submersible pumps mainly function as rejection pumps to prevent foods in densely populated areas, as cold water circulation pumps in large power plants, as pumps to supply irrigation water, as drainage pumps to prevent flooding of agricultural lands, as water supply intake pumps, and as inflow pumps for sewage treatment. The flow in such turbomachines (submersible pumps) inevitably involves various eddy currents. Since it is almost impossible to accurately grasp the complex three-dimensional flow structure and characteristics of a rotating turbomachine through actual testing, three-dimensional numerical analysis using computational fluid dynamics techniques measuring the flow field, velocity, and the pressure can be accurately predicted. In this study, the shape of the impeller was developed to reduce vibration and noise. This was done by increasing the efficiency of the existing submersible pump and reducing turbulence. In order to evaluate the pump's efficiency and turbulence reduction, we tried to analyze the flow using ANSYS Fluent V15.0, a commercial finite element analysis program. The results show that the efficiency of the pump was improved by 4.24% and the Reynolds number was reduced by 15.6%. The performance of a developed pump with reduced turbulence, vibration, and noise was confirmed.

Effect of municipal sludge from drainage facility on foul smell (도시내 배수설비 슬러지가 악취에 미치는 영향 연구)

  • Yu, Dae-Hyun;Park, Jihoon;Lee, Yong-Hoon;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

Design of dashboard conceptual model for digital twin based smart pipe health monitoring (디지털 트윈 기반 스마트 파이프 상태 감시를 위한 대시보드 개념모델 설계)

  • Hong, Phil-Doo;Kim, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.389-391
    • /
    • 2022
  • Efforts by the Ministry of Environment and local governments in Korea are continuing to manage the aging of water supply and sewage buried underground. With the support of the Korea Institute of Environmental Industry and Technology's water and sewage innovation technology development project, it is conducting a project to predict and exchange accidents due to aging, and to apply smart functions to new buried pipes. As one of these studies, this paper proposes the design of a dashboard concept model for digital twin-based smart pipe health monitoring, one of the key features of the entire study. Since remote control and monitoring are one of the main functions, distributed transmission and reception agents are deployed to visualize monitoring situations in real time and to increase user affinity by deploying intuitive UI. To validate the design of this proposed special digital twin based smart pipe state monitoring, we construct the conceptual model level and measure the agent effectiveness to validate its excellence.

  • PDF