A Numerical Method to Calculate Drainage Time in Large Transmission Pipelines Filter (대구경 관로의 배수시간 산정을 위한 수치해석 기법)

  • Shin, Byoung-Ho;Choi, Doo-Yong;Jeong, Kwansue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.511-519
    • /
    • 2017
  • Multi-regional water supply system, which installed for supplying multiple water demands, is characterized by large-sized, long-distance, tree-type layout. This system is vulnerable to long-standing service interruption when a pipe breaks is occurred. In this study, a numerical method is proposed to calculate drainage time that directly affects time of service interruption. To begin with, governing equations are formulated to embed the delayed drainage effect by the friction loss, and to resolve complicated connection of pipelines, which are derived from the continuity and energy equations. The nonlinear hydraulic equations are solved by using explicit time integration method and the Newton-Raphson method. The developed model is verified by comparing the result with analytical solution. Furthermore, the model's applicability is validated by the examples of pipelines in serial, in parallel, and complex layout. Finally, the model is utilized to suggest an appropriate actions to reduce the deviation of draining time in the C transmission line of the B multi-regional water supply system.

Design of Multi-Regional Water Supply System Based on the Optimization Technique (최적화 기법을 이용한 광역상수도 관로시스템 설계)

  • Kim, Ju Hwan;Kim, Zong Woo;Park, Jae Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.95-112
    • /
    • 1999
  • In this research, it is proposed that optimization method is introduced and applied to the design of pipeline system in multi-regional water supply project, which has been constructed to settle the regional unbalance problems of available water resources. For the purpose, interface programs are developed to integrate linear programming model and KYPIPE model which is used for optimization and hydraulic analysis, respectively. The developed program is applied to the pipeline system design of multi-regional water supply project. The optimal diameters from the application of linear programming technique are compared with those from conventional method that is time-consuming and tedious trail and error process. Since the conventional design largely depends upon the experience of designers and the results of general hydraulic analysis, it can not be reasonable and consistent. The application of linear programming technique can make it possible to design pipeline system optimally by using same design factors of general hydraulic models. The model can select commercial discrete pipe diameter as optimal size by using pipe length as decision variables. The developed model is applied to Pohang multi-regional water supply system design with two different objective functions, which are initial construction cost and annual cost including electric cost. As results, it is calculated that the initial construction cost of 1,449,740 thousand won is saved and annual cost of 128,951 thousand won is saved for a year within study year. Also, the optimal site of pump station is selected on 5th pipe, which is located between the diverging junction to Kangdong(2) province and the diverging junction to Cheonbuk province. It is explained that pump cost is less than pipe cost in this application case study due to little pump station scale. In the case of water supply with large pump capacity, it is reasonal that the increase of pipe size is more efficient instead the increase of pump station capacity to save annual cost.

  • PDF

Development of a PC-Based Water Supply Facilities Information System (개인용 컴퓨터를 이용한 상수도 시설물 관리 정보체계 개발)

  • 황국웅;이규석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.2
    • /
    • pp.187-197
    • /
    • 1994
  • The purpose of this study is to develop a PC-based water supply facilities information system. This system will be a major stepping-stone for developing Geographic Information Systems(GIS) in Korea, which is constructed by integrating the technologies related to Automated Mapping(AM) systems and Facilities Management(FM) system. And the results of this study are as follows: (1) After the user needs assessment, it was decided that information management of the water supply facilities including distribution pipes, valves, and leaking management are the most urgent tasks. So, the system was developed focusing on these tasks. (2) After the system design and development, the water supply facilities information system consists of graphic database management system, attribute database management system, internal interface that links graphic data and attribute data, and graphic user interface for user-friendliness. (3) The graphic data and the attribute data including distribution pipes, leading-pipes, valves, and parcels at the study area, Non-Hyun Dong Kang-Nam Gu in Seoul, were used in this system, and the water supply facilities database was established. It was applied to test these facilities, and proved that the system developed in this study is efficient to manage information within the scope of this study. (4) The function using the parcel identification number was efficient to locate the address concerned.

  • PDF

Digital Twin based Household Water Consumption Forecasting using Agent Based Modeling

  • Sultan Alamri;Muhammad Saad Qaisar Alvi;Imran Usman;Adnan Idris
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.4
    • /
    • pp.147-154
    • /
    • 2024
  • The continuous increase in urban population due to migration of mases from rural areas to big cities has set urban water supply under serious stress. Urban water resources face scarcity of available water quantity, which ultimately effects the water supply. It is high time to address this challenging problem by taking appropriate measures for the improvement of water utility services linked with better understanding of demand side management (DSM), which leads to an effective state of water supply governance. We propose a dynamic framework for preventive DSM that results in optimization of water resource management. This paper uses Agent Based Modeling (ABM) with Digital Twin (DT) to model water consumption behavior of a population and consequently forecast water demand. DT creates a digital clone of the system using physical model, sensors, and data analytics to integrate multi-physical quantities. By doing so, the proposed model replicates the physical settings to perform the remote monitoring and controlling jobs on the digital format, whilst offering support in decision making to the relevant authorities.

Formation and Treatment Methods of N-Nitrosodimethylamine (NDMA) in Water and Wastewater (상하수에서 N-Nitrosodimethylamine (NDMA) 발생 및 처리법 비교 분석)

  • Kim, Jongo;Lee, Woo-Bum;Park, Soo-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.1
    • /
    • pp.95-101
    • /
    • 2014
  • Overall studies for the N-nitrosodimethylamine (NDMA) formation and treatment methods were conducted. In this study, occurrence in several countries and emerging treatment technologies of NDMA were generally reviewed. The NDMA formation was dependent on pH, contact time, and molar ratio (monochloramine/dimethylamine). The formation was rapidly increased when the molar ratio was greater than 1. It was likely that monochloramine could be related to stimulate NDMA formation. NDMA concentrations in water supply and wastewater plants after disinfection were approximately 10 ng/L and 100 ng/L, respectively. UV oxidation and adsorption processes are regarded as effective technologies for the NDMA removal. It is suggested that the UV oxidation with proper lamps is applied in water supply system.

Feasibility Study on the Conjunctive Operation of Water Transmission Systems from Multiple Source with Applying EPAnet (수리해석(水理解析) 모형(模型)을 이용한 다수원(多水源) 송수계통(送水系統)의 연계(連繫) 운영(運營) 방안(方案) 경제성(經濟性) 평가(評價) - 거제시(市)를 대상(對象)으로 -)

  • Ryu, Tae-Sang;Ha, Sung-Ryong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.609-619
    • /
    • 2007
  • The objective of this paper is to evaluate the feasibility of conjunctive Operation between Multi-regional water supply networks from multiple source as a effective way to meet two conditions: to minimize the electric cost for providing water demanded and meet the water flow rate for satisfying customers. EPAnet Model is used to calculate a hydraulic water distribution condition based on an integrated operation of water supply systems located in short distance. The modeling was conducted on several simulation cases including the individual operation by existing inter-regional water supply networks within short distance, the conjunctive operation of more than two existing networks with valve fully closed and full open constraint. As a study distribution system, water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. It was found that a well-allocated water supply scheme based on a conjunctive operation promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. The result such as unit district costs, pareto optimum pump combination sets will be applied to the optimization for a conjunctive operation of existing inter-regional water supply networks within short distance.

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

A Study on the Drinking Water Quality and Problem of Simple Piped Water Supply System in a Rural Area (일부 농촌지역 간이상수도의 운영실태와 수질에 관한 조사연구)

  • 김영규
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.39-51
    • /
    • 1992
  • This study was carried out for 1 year between 1990 and 1991. The interviewers visited 513 households to evaluate the perception of the residents using the Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 48 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are summarized as follows: 1) Approximately 44.0% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 8 sites and valley water in 40 sites. 3) Considering the type of distribution of the SPWS, there are 40 natural gravity systems and 8 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 73.9% of the SPWS facilities %'ere used more than ten years. 5) 47.4% of the SPWS facilities are neighbored with pollution source. 6) 42.4% of the maintenance crews were not committed to their job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 36.9% of the residents complaind that the amount of daily water supply is not adequate. 8) About 55.6% of the residents felt that the water quality is good for drinking water and therefore, But in contrast, the biochemical tests indicated that most of the SPWS met the drinking water quality standards. 9) Under the present water analysis system, The method of sampling and analysis are not effective, so that analysis system shoud be done by local health center.

  • PDF

Evaluation of Water Supply Adequacy using Real-time Water Level Monitoring System in Paddy Irrigation Canals (실시간 관개수로 수위 모니터링을 활용한 논 관개용수 공급적정성 평가)

  • Hong, Eun Mi;Nam, Won-Ho;Choi, Jin-Yong;Kim, Jin-Taek
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • Appropriate amount of water supply to paddy fields in proper time is important to achieve efficient agricultural water management. The purpose of this study is to evaluate the irrigation water supply adequacy for paddy fields using water level data in irrigation canals. For the evaluation, the real-time water level data were collected from main canals in the Dongjin irrigation district for 2 years. Using the water level data, delivered irrigation water amounts at the distribution points of each canal were calculated. The water balance model for paddy field was designed considering intermittent irrigation and the irrigation water requirement was estimated. Irrigation water supply adequacy was analyzed from main canals to the irrigation blocks based on the comparison between estimated requirement and delivered irrigation water amounts. From the adequacy analysis, irrigation water supply showed poor management condition in 2012 with low efficiency except the Daepyong canal section, and the adequacy in 2013 was good or fair except the Yongsung canal section. When irrigation water for paddy fields was insufficient, water supply adequacy was affected by irrigation area, but when irrigation water was enough to supply, adequacy was affected by distance from main canal to distribution points. These results of the spatial and temporal dimensions of the irrigation adequacy could be utilized for efficient irrigation water management to improve the temporal uniformity and equity in the water distribution for paddy fields.

Design Modification of a Thermal Storage Tank of Natural-Circulation Solar Water Heater for a Pressurized System (자연순환형 태양열 온수기 축열조의 압력식 설계 개조)

  • Boo, Joon-Hong;Jung, Eui-Guk
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.45-54
    • /
    • 2007
  • For a conventional natural-circulation type solar water heater, the pressure head is limited by the height between the storage tank and hot water tap. Therefore, it is difficult to provide sufficient hot water flow rate for general usage. This study deals with a design modification of the storage tank to utilize the tap-water pressure to increase hot-water supply Based on fluid dynamic and heat transfer theories, a series of modeling and simulation is conducted to achieve practical design requirements. An experimental setup is built and tested and the results are compared with theoretical simulation model. The storage tank capacity is 240 l and the outer diameter of piping was 15 mm. Number of tube turns tested are 5, 10, and 15. Starting with initial storage tank temperature of $80^{\circ}C$, the temperature variation of the supply hot water is investigated against time, while maintaining minimum flow rate of 10 1/min. Typical results show that the hot water supply of minimum $30^{\circ}C$ can be maintained for 34 min with tap-water supply pressure of 2.5 atm, The relative errors between modeling and experiments coincide well within 10% in most cases.