• 제목/요약/키워드: Water Supply Installations

검색결과 20건 처리시간 0.033초

급수기구 발생음의 실험실 측정방법 제4부 : 특수 기구의 설치방법 및 작동조건 (Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 4: Mounting and operating conditions for special appliances)

  • 정갑철;양관섭;박현구;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.990-993
    • /
    • 2004
  • The method of measurement for laboratory tests on noise emission from appliances and equipment used in water supply installations is specified in ISO 3822-1 This part of standard gives detailed descriptions for mounting and operating conditions for laboratory tests of appliances of such construction that they cannot easily be considered as draw-off or in-line appliances, e.g. water heaters, shower heads, etc.

  • PDF

상수도관망에서 제한급수에 따른 간헐적 흐름의 특성 및 제어 (Characteristics and control of intermittent flow in water distribution systems due to restricted supply)

  • 양강승;김동홍;정관수;김주환
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.1-11
    • /
    • 2014
  • The water distribution system should be invariably operated on continuous pattern for 24 hours a day. Occasionally, it is not practically possible to operate for 24 hours due to water shortage or financial constraints. Therefore an intermittent water supply is unavoidable in water shortage area and developing countries. But the intermittent water supply can introduce large pressure forces and rapid fluid accelerations into a water supply network. These disturbances may result in new pipe failure, leakage and secondary contamination. This paper proposed an improvement methodology to prevent the disturbances by intermittent water supply. For the study, the hydraulic variation of intermittent flow in water distribution system was measured and analyzed in the field by comparing with simulation of hydraulic model. Installations of control valves such as, pressure reducing and sustaining and air valves were employed for pressure and flow control. The effectiveness of the methods are presented by comparing hydraulic conditions before and after introducing the proposed solutions.

상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석 (Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline)

  • 이호현;홍성택
    • 한국정보통신학회논문지
    • /
    • 제25권6호
    • /
    • pp.834-840
    • /
    • 2021
  • 먹는 물을 생산하여 공급하는 상수도 관로에 있어서 압력계에 대한 설치와 관리 방안이 미비함에 따라 압력데이터 신뢰성의 확보 및 운영관리의 어려움을 겪고 있는 실정이다. 관망 및 펌프 등 운영관리 효율화 및 SWM(Smart Water Management)을 구현하기 위해서는 하부 계측 센서의 정확한 데이터 취득을 통하여 의사결정이 이루어져야 한다. 따라서, 본 연구에서는 게이트 밸브와 버터플라이 밸브를 중심으로 관로의 직경(D)을 기준으로 전단 -3D에서부터 후단 7D까지 압력계를 설치하여 밸브의 개도율을 조절하며 데이터를 취득하는 직관 거리 시험을 실시하였으며, 관로에 수직으로 상단(180°)부터 하단(0°)까지 45° 각도 간격으로 압력계를 설치한 후 수직 위치 시험을 실시하였으며, 이 결과들을 바탕으로 압력계의 최적 위치선정 방안을 제시하고자 한다.

장수명 공동주택의 SI분리공급 활성화를 위한 제도개선 방향설정 연구 (A Study on the Revision of Regulation to Develop for Supply of SI Separation in Long-Life Housing)

  • 정준수;김수암
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.475-478
    • /
    • 2008
  • In Korea, there has been a tendency that multi-family housings are constructed by providers such as constructors or real estate agents for the economical benefits and selling efficiency, using standardized plans, load-bearing wall system, water-based construction method, and uniformized formworks. Especially, the traditional installation works which service equipments are buried into structures cause serious problems such as shortening building life span, increasing times of remodeling during specific period (100 years) and wasting resources. Also the unilateral way of massive distribution by providers for multi-family housings is not appropriate to meet the various social needs of residents. To solve these problems, it is necessary to build long-life housing which can be easily separated installations, interior and exterior finishings from structural parts. Therefore, this paper will examine the present administrative law and the civil law in order to find negative factors that can be obstructions for providing long-life housings and set the direction to revise the regulations.

  • PDF

직결식 변속펌프의 운전 방안에 대한 연구 (A Study on the Operating Characteristics of Variable Speed Pump for In-Line Booster Pumping Station)

  • 박종문;최성일;노형운;서상호;김상균
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.191-196
    • /
    • 2001
  • In the systems with largely pipe head loss, variable speed pumps are generally used because substantial energy saving can be expected from such systems by controlling pump speed and also they offer simpler maintenance and operational ease even in conditions where abrupt changes In flow rate and head can occur. The invertor or the fluid coupling system are mainly adopted to control the rotating speed. In this paper, operating conditions at Migum pressing pump station(5 stage), where the fluid coupling system was the first installed for KOWACO, are investigated and analysed so that information thus gained can be usefully employed in the efficient operation of variable speed pump in new installations of in-line booster pumping station.

  • PDF

반구형 접지모의시스템을 이용한 접지전극의 형상에 따른 대지전위상승의 분석 (The Analysis of Ground Potential Rise for Shapes of Grounding Electrode Using Hemispherical Grounding Simulation System)

  • 길형준;최충석;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권7호
    • /
    • pp.319-325
    • /
    • 2005
  • In order to analyze ground potential rise of grounding system installed in buildings, the hemispherical grounding simulation system has been designed and fabricated as substantial and economical measures. Ground potential rise(GPR) has been measured and analyzed for shapes of grounding electrode using the system in real time. The system is apparatus to have a free reduced scale for conductor size and laying depth of a full scale grounding system and is constructed so that a shape of equipotential surface is nearly identified a free reduced scale with a real scale when a current flows through grounding electrode. The system was composed of a hemispherical water tank, AC Power supply, a movable potentiometer, and test grounding electrodes. The test grounding electrodes were fabricated through reducing grounding electrode installed in real buildings such as rod type, mesh grid type. When a mesh grid type was associated with a rod type, GPR was the lowest value. The proposed results would be applicable to evaluate GPR in the grounding systems. and the analytical data can be used 0 stabilize the electrical installations and prevent the electrical disasters.

어촌·어항을 활용한 해양스포츠 체험관광 활성화 방안 (The Promotion of Experiential Marine Sports by Developing aPlan for Fishing Village and Port)

  • 지삼업;김용재;이재형
    • 수산해양교육연구
    • /
    • 제17권1호
    • /
    • pp.86-105
    • /
    • 2005
  • The plan of developing a fishing village and port will be indirectly funded by the government. In the short term, there will be five different multi-functional fishing village models which are based on the first industry to attach to the third industry of marine sports experience tourism. In the long run, they have to be reached gradually. The popular scenic spot of the marine sports experience tourism is made by human resources and fundamental installations considering that it must be done in unpolluted water. It is necessary to separate the fish harbor into two sides. One side is an existing fishing industry. The other side is made up of several pontoons for the marine sports equipment of the marine mooring. It is necessary to build facilities, such as the mooring facility, the storage facility, the repair-check facility, supply-cleaning facility, information booth, accommodations, education facility, and a marine culture exchange facility.

Distribution of Potential Rise as a Function of Shape of Grounding Electrodes

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Kim, Hyang-Kon
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.73-79
    • /
    • 2007
  • In order to analyze the potential rise of grounding systems installed in buildings, a hemispherical grounding simulation system was studied. Potential rise was measured and analyzed regarding the shape and distance of the grounding electrodes by using this system. The system was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured in real time by the horizontal moving probe of be potentiometer. The test grounding electrodes were fabricated through reducing the grounding electrode installed in real buildings such as the ground rod, grounding grid and so on. The potential rise was displayed in a two-dimensional profile and was analyzed regarding the shapes of the ground electrodes. The potential rise of the grounding grid combined with a ground rod was the lowest of every grounding electrode tested. The proposed results can be applicable to evaluating ground potential rise in grounding systems, and the analytical data can be used to stabilize the electrical installations and prevent electrical disasters.

ETFE 필름을 적용한 태양광 모듈의 전기적 출력 및 신뢰성에 관한 연구 (Electrical Output and Reliability of Photovoltaic Module Using Ethylene Tetrafluoroethylene Film)

  • 신우균;임종록;고석환;강기환;주영철;황혜미
    • 한국태양에너지학회 논문집
    • /
    • 제40권4호
    • /
    • pp.13-22
    • /
    • 2020
  • As the supply of photovoltaic (PV) increases worldwide, the cumulative installations in 2018 were 7.9 and 560 GW in Korea and the world, respectively. Typically, when the ground on commercial PV modules is installed, the area is limited; hence, new designs of PV modules are required to install additional PVs. Among the new design of PV modules, lightweight PV modules can be utilized in PV systems, such as buildings, farmlands, and floating PV. Concerning the investigation of lightweight PV modules, several studies on materials for replacing low-iron tempered glass, which comprises approximately 65% of the PV module weight, have been conducted. However, materials that are used as substitutes for glass should possess similar lightweight properties and reliability as glass. In this study, experimental tests were performed to evaluate the applicability of ethylene tetrafluoroethylene (ETFE) film with excellent resistance to water and aging as a front material of PV modules. The transmittance and ultraviolet properties of the ETFE film were determined and compared with those of glass. A 1-cell module and laboratory-scale 24-cell module were manufactured using the ETFE film and glass, and the electrical output was measured and analyzed. Furthermore, damp heat and thermal cycle tests were conducted to evaluate the reliability of the ETFE film module. Based on the experimental results, the electrical output and reliability of the ETFE film module were similar to those of the glass module, and the ETFE film could be used as the front material of PV modules.

소방수 공급설비에 대한 공통원인고장을 고려한 확률론적 신뢰도 분석 (Reliability Analysis on Firewater Supply Facilities based on the Probability Theory with Considering Common Cause Failures)

  • 고재선;김효
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.76-85
    • /
    • 2003
  • 본 논문에서는 공통원인고장의 이론적 고찰로서 정의와 그 원인, 분석방법을 기술하고 대표적인 소방설비의 하나인 소방펌프에 대해 공통원인고장을 고려한 신뢰도분석에 적용함으로써 공통원인고장의 중요성과 그 한계성을 규명하고자 한다. 공통원인고장을 고려한 소방수 공급설비에 대한 신뢰도분석 결과 알 수 있듯이 펌프의 운전고장이 계통실패의 가장 큰 요인으로 나타났으며 특히 두 펌프의 공통원인고장이 지배적이다. 다시 말하면 공통원인고장을 고려하지 않을 경우에 계통신뢰도를 실제보다 2배 이상 초과하여 평가할 수 있다는 것이다. 이로서 계통 신뢰도분석에서 공통원인고장의 중요성을 인식할 수 있으며 분석결과는 공통원인고장의 변수인자의 값에 크게 의존하는 것을 알 수 있다. 그리고 소방수 공급설비설계에 계통설계 시 다중성을 반영하면 신뢰도가 증가하는 것은 사실이나 공통원인고장 요인 때문에 다중기기 설치대수에 비례하는 정도의 신뢰도 향상을 얻지 못할 수도 있다. 또한 공통원인고장의 한계성으로는 분석모델의 차이로 인한 차이는 미미한 수준이었으나 각각 다른 데이터 원을 사용했을 경우 그 결과는 큰 차이를 나타내었다. 따라서 공통원인고장 분석에 사용되는 모델보다는 이용 가능한 경험데이터의 품질이 그 분석결과의 신뢰성에 큰 영향을 미친다는 것을 알 수 있었다. 결과적으로 다중기기의 공통원인고장을 방지하기 위한 기본적이고 공학적인 방안으로는 설계시 요구되는 적정 신뢰도를 유지하는 것이므로 적어도 소방펌프에 요구되는 신뢰도수준으로 설계되어야 한다. 즉 SIS(Safety Instrumented system)에 요구되는 신뢰도수준인 안전건전성수준(SIL; Safety integrity level)에 적합한가의 유무를 PFD를 활용하여 정량적으로 파악하는 것이다. 공통원인고장을 고려한 소방수 공급설비에 대한 신뢰도분석 결과 계통작동요구시 실패확률(PFD: Probability of failure on demand), 즉 계통 이용 불능도는 3.80E-3이므로 규정목표인 SIL5의 범주 안에 들어있지 않아 안전건전성수준으로 설계되어 있지 않다고 판단되며, 만일 공통원인고장을 고려하지 않았을 경우인 계통 이용불능도 또한 1.82E-3으로 계산되는데, 이 또한 SIL5의 범주 안에 들어있지 않으므로 단전건전성수준으로 설계되어 있지 않다고 판단된다.