• Title/Summary/Keyword: Water Stops

Search Result 23, Processing Time 0.028 seconds

An Experimental Study on Performance of neater Stops at Construction joints in Tunnel (터널 시공이음부에서의 방수재 역할에 대한 실험연구)

  • 백송훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.217-223
    • /
    • 1999
  • Mostly, water leakage took place in construction joints. In case of cable tunnels constructed by open-cut method, waterstops have been used to prevent the water leakage. But, we haven't any experience to install the waterstops in NATM cable tunnels. So, it is necessary to develope the waterstops and test the performance of it in laboratory. We manufactured cable tunnel lining quarter scale model by pouring concrete, and installed the waterstops. After filling the inside of concrete lining about two-third with water, we put the air pressure on the water, In addition, it is also carried out water leakage test for concrete lining model without waterstops. As a result, we confirmed the performance of waterstops and its adaptability. It is also tested that the performance of rubber gaskets used in concrete segments of Shield tunnelling. In addition, we determined the allowable infiltration rate for cable tunnel with non-drainage system.

  • PDF

Development of a constant pressure feed system using a constant pressure proportional control mode (정압비례제어방식을 적용한 정압급수장치의 개발)

  • 김주명;김광열;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1026-1031
    • /
    • 2003
  • Automatic feed pumps are operated and stopped by a pressure switch. Thus, because of repeated operations and stops of the pumps according to fluctuations of water volume, operation with constant rate and pressure is impossible. Moreover, because of repeated running of the pump, keeping up of constant pressure is impossible and damage and energy loss are weak points of the pimps. To make up for defects of an automatic feed pump, this paper designed and made a static pressure feed system which was composed of a feed water control valve, a flow sensor and a control system. The valve device plays an important part in reducing load of pumps by constant water supply regardless of outflow of water. Outflow of water is determined by infrared diode of the flow sensor. The control system is made of a 8 bit micro-processor and the pump was controled by a specific control algorithm. With the constant pressure feed system, discharge pressure was kept at fixed pressure, accurate operations and stops were smoothly accomplished and the pump was operated with constant pressure. Thus, the constant pressure feed system can be considered as an advanced system which made up for the weak points in the current automatic feed systems.

A Study on the Application of Non-glutinous rice in Shanghanlun (『상한론(傷寒論)』의 갱미(粳米) 입약법(入藥法)에 대한 고찰)

  • Ahn, Jin-hee
    • Journal of Korean Medical classics
    • /
    • v.32 no.2
    • /
    • pp.71-92
    • /
    • 2019
  • Objectives : To examine various ways non-glutinous rice has been applied in different formulas of "Shanghanlun" and the relationship between non-glutinous rice and the formulas' effects. Methods : First, texts that included non-glutinous rice were selected from the "Shanghanlun". Then, they were categorized according to the application of non-glutinous rice, followed by analysis of its relationship with each formula. Results : Most formulas that used non-glutinous rice in raw form when decocting with other ingredients included Shigao. Non-glutinous rice alleviates coldness of Shigao as in the case with Taohuatang where it stops diarrhea. Non-glutinous rice used in Wumeiwan warms the center and boosts Qi and helps the medicinal ingredients to bind when made into pellets. In Guizhitang and Lizhongwan, non-glutinous rice assists Stomach Qi. In Shizaotang, porridge is taken after diarrhea to help quick recovery. To prevent damage of Zheng Qi, Baisan can be mixed with rice water for administration. The level of cathartic effect can be managed through giving cold or hot porridge to the patient according to his/her response to the medicine. Mazirenwan, Mulizexiesan, Banxiasan, Sinisan, Wulingsan are mixed in rice water for administration. It makes it easier to swallow than when mixed with plain water. The application of rice flour is either internal or external. In Zhufutang, where rice flour is parched, it harmonizes the center and stops diarrhea. In Daqinglongtang when there is too much perspiration, warm powder is sprinkled on the skin to stop sweating. Clear porridge in Jiuziyisifang and rice flour in Shechuangzisan were exclusive to "Jinguiyaolue", while Baisan and rice water mixture could only be found in "Shanghanlun". Conclusions : The excavation and research on various ways non-glutinous rice was applied in treatment holds certain meaning in contemporary practice of Korean Medicine where treatment leans heavily on medicinal treatment rather than food, and all ingredients are boiled together in large quantities for most decoctions.

Design of the Heat Exchanger in Pool Water Management System of a Research Reactor and Estimation of the Pool Water Temperature Using CFD (전산유체해석을 이용한 연구용원자로 수조수관리계통 열교환기 설계 및 수조수 온도 예측)

  • Jeong, Namgyun
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.45-51
    • /
    • 2016
  • The pool water management system, which is installed for purification of the coolant in the pools and the primary cooling system of a research reactor, removes the decay heat from the reactor core when the primary cooling system stops. It also removes the heat generated from the irradiated objects in the service pool and the spent fuels in the spent fuel storage pool to keep the temperature of the pools within a limited value. In this study, the heat exchanger of the pool water management system is designed by CFD method using a commercial code Flowmaster, and the temperature of the pools is estimated along the time to conclude the design and operation method of the pool water management system.

Integrated Expansion Analysis of Pipe-In-Pipe Systems

  • Choi, Han-Suk;Do Chang-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.5 s.72
    • /
    • pp.9-14
    • /
    • 2006
  • This paper presents an analytical method, application of expansion, mechanical design, and integrated expansion design of subsea insulated pipe-in-pipe (PIP) systems. PIP system consists of a flowline and a casing pipe for the transport of high temperature and high pressure product from the subsea wells. To prevent heat lass from the fiowline, insulation material is applied between the pipes. The fiawline pipe and the casing pipe have mechanical connections through steel ring plate (water stops) and bulkheads. Pipeline expansion is defined by temperature, internal pressure, soil resistance, and interaction force between the flowline and the casing pipe. The results of the expansion analysis, the mechanical design of connection system of the two pipes and tie-in spool design are integrated for the whole PIP system.

NEAR-FIELD DILUTION OF ROSETTE TYPE MULTIPORT WASTEWATER DIFFUSERS

  • Seo, Il-Won;Yeo, Hong-Koo
    • Water Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.93-111
    • /
    • 2002
  • In this paper, mixing characteristics and dilution of the merging buoyant discharges from array of multiple jets has been extensively studied in the hydraulic model experiments. New equations for dilution, which include the merging effects correctly, were derived. Experiments were constructed in a 20-m long, 4.9-m wide and 0.6-m deep flume, and the model diffuser was manufactured to indicate the typical characteristics of the existing ocean wastewater outfall in South Korea. Buoyant discharge from the diffuser was reproduced using heated water. Water temperature was measured using CC-Type thermocouple sensors, which were connected to a 40-channel data logger. Experimental results show that merging between ports in a particular riser is dependent upon the discharge densimetric Froude number, whereas merging between two ports which are facing each other at 90$\circ$ at the adjacent risers is dependent upon the discharge densimetric Froude number and distance from the port and port spacing. Centerline dilution increase with distance from the port outlet until two plumes has merged. However, after merging occurs, increase of the centerline dilution almost stops. Further distance from the position where merging occurs, centerline dilution increases again.

  • PDF

A Study on the Drum Water Level Versus Incoming Water Quantities for Small Vertical Hydraulic Water Turbine Plant (종축소수력발전소의 인입수량과 드럼수위와의 관계에 관한 연구)

  • Che, Gyu-Shik;Jung, Ju-One
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.3
    • /
    • pp.254-260
    • /
    • 2014
  • We studied water level rising of drum versus time in the small hydraulic vertical water turbine system in this paper. The water level rises continuously up to a certain point with the passage of time if the constant incoming water is supplied, while it stops rising and maintains equilibrium state without any more rising because it increases position energy and evatually makes outgoing velocity and outgoing water quantities of runner area. The water level of drum is determined independent of size, height, width, figure of drum or runner configuration. It comes out that the water level is dependent only on the incoming and outgoing water quantities, and the output power has similar behavior. Therefore, desirable water level and output power are not available unless incoming water quantities is abundant. We validate this phenomina through applyng our methodolgies to the real small hydraulic vertical water turbine system under constructing and testing in industrial facilities in Korea.

The Size Distribution of Free Water Paths in Heartwood of Softwood by Centrifugal Method - The Difference between Earlywood and Latewood - (원심법에 의한 침엽수 심재부 유효수분이동경로의 반경분포 - 조재와 만재의 비교 -)

  • Park, Jong Su;Chun, Su Kyoung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.61-70
    • /
    • 2003
  • The size distribution of the free water paths between earlywood and latewood for six species in the heartwood of softwoods was estimated from the amount of dehydrated free water under various centrifugal fields, such as 2,200, 3,300, 4,800 and 6,900 rpm. The centrifugal method is based on the concept that water movement occurs by the balance of centrifugal force and water potential by meniscus. Water stops where the pressure differential is zero. In the centrifugal field, only two factors affect water movement in wood, that is, centrifugal force and water potential. Also, the water permeability was evaluated from the relationship between the water saturation ratio after the centrifugal treatment and the measure of water potential in specimen. The results showed that Cryptpmeria japonica had clear peaks at 0.70 ㎛ in earlywood and at 0.50 ㎛ in latewood. Tsuga sieboldii and Larix kaemferi had peaks at 0.50 and 0.30 ㎛ in both earlywood and latewood, respectively. Abies firma showed peaks at 0.70 ㎛ in earlywood and at 0.30 ㎛ in latewood. The water permeability of earlywood was higer than that of latewood for all softwoods except Pseudotsuga menziesii.

Comparison of Wetting and Drying Characteristics in Differently Textured Soils under Drip Irrigation (점적관개 시 토성별 습윤.건조 특성 비교)

  • Kim, Hak-Jin;Son, Dong-Wook;Hur, Seung-Oh;Roh, Mi-Young;Jung, Ki-Yuol;Park, Jong-Min;Rhee, Joong-Yong;Lee, Dong-Hoon
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.309-315
    • /
    • 2009
  • Maintenance of adequate soil water content during the period of crop growth is necessary to support optimum plant growth and yields. A better understanding of soil water movement for precision irrigation would allow efficient supply of water to crops, thereby resulting in minimization of water drainage and contamination of ground water. This research reports on the characterization of spatial and temporal variations in water contents through three different textured soils, such as loam, sandy loam, and loamy sand, when water is applied on the soil surface using an one-line drip irrigation system and the soils are dried after the irrigation stops, respectively. Water contents through each soil profile were continuously monitored using three Sentek probes, each consisting of three capacitance sensors at 10, 20, and 30cm depths. Spatial variability in water content for each soil type was strongly influenced by soil textural class. There were big differences in wetting pattern and the rate of downward movement between loam and sandy loam soils, showing that the loam soil had a wider wetting pattern and a slower rate of downward movement than did the sandy loam soil. The wetting pattern in loamy sand soil was not apparent due to a low variability in water content (< 10%) by a lower-water holding capacity as compared to those measured in the loam and sandy loam soils, implying that the rate of water drainage below a depth of 30cm was high. When soils were dried, there were highly exponential relationships between water content and time elapsed after irrigation stops ($r^2$${\geq}$0.98). It was estimated that equilibrium moisture contents for loam, sandy loam, and loamy sand soils would be 17.6%, 6.2%, and 4.2%, respectively.

The Experimental Research for the Collecting Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 집열특성에 대한 실험적 연구)

  • Lee, Dong-Won;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.12-18
    • /
    • 2013
  • Domestic solar hot water system can be divided into a passive type and an active type. In a passive type the storage tank is horizontally mounted immediately above the solar collectors. No pumping is required as the hot water naturally rises into the storage tank from the collectors through thermo-siphon flow. While, in an active type the storage tank is ground- or floor-mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the storage tank and the collectors. We installed two types solar hot water systems consisting of the same storage tank and collectors at the same place, and were measured and compared typical operating characteristics under the same external conditions. In particular, the daily system performance was presented through the stirring test after the sunset. The results show that the amount of solar radiation obtained for an active type were less than a passive type on a cloudy day, because the operation of the circulation pump stops frequently took place on that day. However, on a sunny day, depending on the stable operation of the circulation pump, the amount of solar radiation obtained for an active type were increased than a passive type.