• Title/Summary/Keyword: Water Retention

Search Result 1,285, Processing Time 0.039 seconds

Recycling of Wastepaper(Ⅷ)-Contamination of Process WAter by System Closure (고지재생연구(제 8보) -제지 공정수 폐쇄화에 따른 오여-)

  • 여성국;류정용;신종호;송봉근;오세균
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.4
    • /
    • pp.1-7
    • /
    • 1999
  • This study was carried out to simulate the change of various properties of recycled water when zero-discharge system was applied to a KOCC recycling process. contaminants such as chemical oxygen demand, anionic trash, and calcium hardness were gradually increased in the process water as the recycling was repeated . Especially, the increase of anionic trash and COD were closely related to the starch derived from corrugating adhesive in KOCC. Four kinds of water were compared in the preparation of handsheet to evaluate the performance of retention program. Waters used in this work were laboratory tab water, process water from Dong-II mill and the same one treated by UASB process, and closed white water prepared by KRICT. The result revealed that one the major factors fro reducing a retention power was the anioni trash accumulated in the recycled water.

  • PDF

Moisture Sorption Isotherm and Quality Deterioration of Dry Jujube (건대추의 등온흡습곡선 및 품질열화특성)

  • 김영숙;안덕순
    • Food Science and Preservation
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 1997
  • In order to provide informations for designing packaging and storage condition of dry jujube (Zizyphus jujuba MILLER), moisture sorption isotherm was determined for temperatures of 20, 30 and 4$0^{\circ}C$, and quality changes were evaluated as function of temperature and water activity. Dry jujube at a given water activity showed higher equilibrium moisture content for lower temperature. Moisture isothem could be fitted by GAB model equation, giving higher C value, lower m0 and relatively constant k value with increase in temperature. Ascorbic acid was lost more highly at higher temperature and water activity, and showed negligible retention for whole range of water activity and temperature studied after 141 days. Browning increased with water activity up to 0.73 at 30 and 4$0^{\circ}C$. Dry jujube of high water activity had high L value in surface color, which represent brightness of surface color. Considering quality retention in the storage, dry jujube is desired to be dried to water activity of 0.42 and be stored at temperature below 3$0^{\circ}C$

  • PDF

Comparisons of Soil Water Retention Characteristics and FDR Sensor Calibration of Field Soils in Korean Orchards (노지 과수원 토성별 수분보유 특성 및 FDR 센서 보정계수 비교)

  • Lee, Kiram;Kim, Jongkyun;Lee, Jaebeom;Kim, Jongyun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.401-408
    • /
    • 2022
  • As research on a controlled environment system based on crop growth environment sensing for sustainable production of horticultural crops and its industrial use has been important, research on how to properly utilize soil moisture sensors for outdoor cultivation is being actively conducted. This experiment was conducted to suggest the proper method of utilizing the TEROS 12, an FDR (frequency domain reflectometry) sensor, which is frequently used in industry and research fields, for each orchard soil in three regions in Korea. We collected soils from each orchard where fruit trees were grown, investigated the soil characteristics and soil water retention curve, and compared TEROS 12 sensor calibration equations to correlate the sensor output to the corresponding soil volumetric water content through linear and cubic regressions for each soil sample. The estimated value from the calibration equation provided by the manufacturer was also compared. The soil collected from all three orchards showed different soil characteristics and volumetric water content values by each soil water retention level across the soil samples. In addition, the cubic calibration equation for TEROS 12 sensor showed the highest coefficient of determination higher than 0.95, and the lowest RMSE for all soil samples. When estimating volumetric water contents from TEROS 12 sensor output using the calibration equation provided by the manufacturer, their calculated volumetric water contents were lower than the actual volumetric water contents, with the difference up to 0.09-0.17 m3·m-3 depending on the soil samples, indicating an appropriate calibration for each soil should be preceded before FDR sensor utilization. Also, there was a difference in the range of soil volumetric water content corresponding to the soil water retention levels across the soil samples, suggesting that the soil water retention information should be required to properly interpret the volumetric water content value of the soil. Moreover, soil with a high content of sand had a relatively narrow range of volumetric water contents for irrigation, thus reducing the accuracy of an FDR sensor measurement. In conclusion, analyzing soil water retention characteristics of the target soil and the soil-specific calibration would be necessary to properly quantify the soil water status and determine their adequate irrigation point using an FDR sensor.

The Analysis of Mesoscale Circulations Characteristics Caused by the Evaporation-Efficiency of Water Retention Pavement (보수성 도로 포장재의 증발효율 변화에 의한 중규모 순환장 특성 분석)

  • Kim, In-Su;Lee, Soon-Hwan;Kim, Hae-Dong;Suh, Young-Chan
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.709-720
    • /
    • 2009
  • Field observation and numerical experiments were conducted to understand the impact of water retention pavement on the surface heat budget and on the regional circulation. The numerical model applied in this study is the atmospheric dynamic model Local Circulation Model (LCM) with two dimensional grid system, and a field observation was carried out under the clear sky and calm conditions of the weather on 19 July 2007. In the field observation, the maximum value of surface temperature on pavement covered with water retention material reached the $41.2^{\circ}C$ at 1430 LST and the values was lower for $16.1^{\circ}C$ than that of asphalt without the material. The Case BET03 assumed to be 0.3 for the surface evaporation efficiency was in good agreement with the observation and its sensible and latent heat fluxes were numerically estimated to be 229 and 227 $W/m^2$, respectively. Results of the numerical experiments demonstrated that the water retention pavement tends to induce the increase of latent heat flux associated with the lower surface temperature and mixing height during the daytime. Discontinuity of latent heat caused by the water retention pavement also tends to promote the development of mesoscale circulation called as land-land breeze or country breeze.

The Role of Charge and Retention in Effective Wet end Management

  • Rantala, T.;Nokelainen J.;Ojala, T;Dr. Taina Sopenlehto
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.1-10
    • /
    • 2000
  • The development of paper machines, increasing machine speeds with new, mostly low basis weight and/or high ash content paper grades, as well as the fact that several trends regarding process items have increased the sensitivity of papermaking. At the same time, papermakers are looking for flexibility in the production line. We can say that with all PMs the biggest benefits with the lowest capital spending can be achieved by focusing on improved wet end management. In order to manage wet end chemistry on a paper machine, our goal is to control sub-process through which we can influence the operation of the entire wet end with maximum effect. Key measurements and controls are-white water consistency control which is the most effective way to control retention - charge demand measurement and control which takes care of concentration of the anionic material entering to PM -ash measurements and controls which are deeply related to retention and paper quality This paper presents and concentrates to two of these key controls ; retention and charge. The purpose of charge control is to give the process control the tools to react to changes caused by amount of dissolved and colloida material incoming to wet end system. It is called coagulation or fixing control. Retention control is then taking care of retention aid flow to the process by responding any changes seen in white water consistency. It is called flocculation control. Each of these solutions separately , and even more effectively all together, stabilize the wet end operations and so greatly improve the produced paper quality and machine runnability. Practical results will be presented and they are referring to the latest mill cases. We have developed the first wet end measuring system in the late 1980s and control solutions based on this modern measuring technology were completely updated in 1990s. This paper introduces the principle, operation , and results of our unique wet end analyzers (retention and charge ) which are at the level of automation solutions as a part of paper machine quality control Especially our newest member of the platform , on-line charge analyzer has reached and set new standards to the on-line charge monitoring.

The Role of Charge and Retention in Effective Wet End Management

  • Rantala, T.;Nokelainen, J.;Ojala, T.;Sopenlehto, Taina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.44-53
    • /
    • 2000
  • The development of paper machines, increasing machine speeds with new, mostly low basis weight and/or high ash content paper grades, as well as the fact that several trends regarding process items have increased the sensitivity of papermaking. At the same time, papermakers are looking for flexibility in the production line. We can say that with all PMs, the biggest benefits with the lowest capital spending can be achieved by focusing on improved wet end management. In order to manage wet end chemistry on a paper machine, our goal is to control subprocesses through which we can influence the operation of the entire wet end with maximum effect. Key measurements and controls are - white water consistency control which is the most effective way to control retention. - charge demand measurement and control which takes care of concentration of the anionic material entering to PM. - ash measurements and controls which are deeply related to retention and paper quality. This paper presents and concentrates to two of these key controls: retention and charge. The purpose of charge control is to give the process control the tools to react to changes caused by amount of dissolved and colloidal material incoming to wet end system. It is called coagulation or fixing control. Retention control is then taking care of retention aid flow to the process by responding any changes seen in white water consistency. It is called flocculation control. Each of these solutions separately, and even more effectively all together, stabilize the wet end operations and so greatly improve the produced paper quality and machine runnability. Practical results will be presented and they are referring to the latest mill cases. We have developed the first wet end measuring system in the late 1980s and control solutions based on this modern measuring technology were completely updated in 1990s. This paper introduces the principle, operation, and results of our unique wet end analyzers (retention and charge) which are at the level of automation solutions as a part of paper machine quality control. Especially our newest member of the platform, on-line charge analyzer has reached and set new standards to the on-line charge monitoring.

  • PDF

Retention Behavior of the Phenols on the Binary and Ternary Mobile Phases in Reversed-Phase Liquid Chromatography (역상 액체크로마토그래피에 있어서 이성분과 삼성분 이동상에 대한 페놀류의 머무름 거동)

  • Dae Sub Oh;Sun Haing Lee;Soo Han Kim;Sang Tae Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.352-358
    • /
    • 1986
  • An extensive experimental survey on the retention behaviors of phenols in the binary solvent system such as methanol-water, acetonitrile-water and tetrahydrofuran-water as well as the ternary solvent system such as methanol-acetonitrile-water and methanol-tetrahydrofuran-water is presented. A linear equation, which describes the capacity factor as a function of the solvent composition in the mobile phase and is able to predict the retention behaviors of phenols, was obtained. The iso-eluotropic lines for the binary and ternary solvent system are based on the equal strength of the methanol-water solvent which shows an optimum separation of the phenols used. The specific effect of each solute in the binary solvent system appeared to be larger than those in the ternary system.

  • PDF

Effect of Copper Retention on Copper Leaching in Wood Treated with Copper-based Preservatives

  • Ra, Jong-Bum;Kang, Sung-Mo;Kang, Shin-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.421-425
    • /
    • 2009
  • This research investigates the effect of copper retention on copper leaching in wood treated with copper-based preservatives. Radiata pine (Pinus radiata D. Don) sapwood samples were ground in a Wiley mill equipped with a 20-mesh screen. The ground wood was vacuum-treated with various concentrations of alkaline copper quat (ACQ), bis-(N-cyclohexyl-diazeniumdioxy)-copper (CB-HDO), and copper azole (CUAZ). The treated samples were conditioned at $70^{\circ}C$ and 100% RH for 72 hours. The samples were leached by using the distilled water for four weeks, and the copper contents in each sample were measured by X-ray spectroscopy. As expected, the copper leaching was increased with increasing of copper retention. The copper leaching from the ACQ and CB-HDO treated samples were gradually decreased with increasing copper retention: however, the copper losses from the CUAZ treated samples appeared to be proportionally increased with the increase in copper retention in all retention levels tested. The results indicate that at the conditions of the same copper retention ACQ and CB-HDO treated wood have a better leaching resistance compared to CUAZ treated wood.

Mass Transfer and Optimum Processing Conditions for Osmotic Conditions of Potatoes prior to Air Dehydration (열풍건조 전 감자의 삼투압농축시 물질이동과 공정의 최적화)

  • Kim, Myung-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.497-502
    • /
    • 1990
  • The effect of sugar concentration, immersion time and temperature on water loss, solid gain or loss, and sugar molality of potatoes during osmotic concentration was analyzed by a response surface methodology (RSM), and those values were predicted by using a second degree polynomial regression model. Effect of osmotic concentration and blanching on vitamin C retention of air dried potatoes (6% MC: wet basis) was also evaluated. The most significant factor was sugar concentration for water loss, solid gain or loss, sugar molality, rate parameter and retention of vitamin C. Second and third factors were immersion time and temperature respectively. Water loss and solid gain were rapid in the first 10 min and then levelled off. A 44.6% of water loss was observed during osmotic concentration using a sugar solution $(60\;Brix,\;80^{\circ}C$) with 20 min of immersion time. Dried potatoes after osmotic concentration had higher vitamin C content than dried potatoes after blanching. Optimum regions for osmotic concentration process of potatoes were $60-70^{\circ}C$ of immersion temperature, 60 Brix of sugar solution and 16-20 min of immersion time based on above 30% of water loss and 50% of vitamin C retention.

  • PDF

mprovement of Estimation Method of Load Capture Ratio for Design and Evaluation of Bio-retention LID Facility (생태저류지 LID 시설의 설계 및 평가를 위한 삭감대상부하비 산정방법 개선)

  • Choi, Jeonghyeon;Lee, Okjeong;Kim, Yongseok;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.6
    • /
    • pp.569-578
    • /
    • 2018
  • To minimize the negative alterations in hydrologic and water quality environment in urban areas due to urbanization, Low Impact Development (LID) techniques are actively applied. In Korea, LID facilities are classified as Non-point Pollution Reduction Facilities (NPRFs), and therefore they are evaluated using the performance evaluation method for NPRFs. However, while LID facilities are generally installed in small, distributed configuration and mainly work with the infiltration process, the existing NPRFs are installed on a large scale and mainly work with the reservoir process. Therefore, some limitations are expected in assessing both facilities using the same method as they differ in properties. To solve these problems, in this study, a new method for performance evaluation was proposed with focus on bio-retention LID facilities. EPA SWMM was used to reproduce the hydrologic and water quality phenomena in study area, and SWMM-LID module used to simulate TP interception performance by installing a bio-retention cell under various conditions through long-term simulations. Finally, an empirical formula for Load Capture Ratio (LCR) was derived based on storm water interception ratio in the same form as the existing method. Using the existing formula in estimating the LCR is likely to overestimate the performance of interception for non-point pollutants in the extremely low design capacity, and also underestimate it in the moderate and high design capacity.