• 제목/요약/키워드: Water Resistivity

검색결과 383건 처리시간 0.028초

폐광산의 AMD 오염영역탐지를 위한 지구물리탐사 (Geophysical Surveys for Mapping of the AMD Contaminant Channels at an Abandoned Mine)

  • 김지수;최상훈;한수형
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.258-261
    • /
    • 2000
  • Geophysical surveys (electrical resistivity, self-potential, and magnetic methods) and streamwater sample analysis have been carried out at a site of tailings of waste deposits in an abandoned mine, Jangpoong, which is situated in Kowesan-Gun, Chungbuk-Do. The research was aimed at investigating the suitability of the various geophysical methods for detection of AMD (acid mine drainage) paths, and ultimately mapping of preferred AMD flow channels by incorporating the water sample analysis. Electrical resistivity section from the dipole-dipole line represents the low-resistivity zone trending northwest toward the stream nearby. The positions of the resistivity anomalies for AMD channels are well correlated to the ones from the various geophysical surveys. In addition they correspond to the sites of the higher peaks for the pH, EC, heavy metal content for the water sample data.

  • PDF

염류집적 농경지에서 전기비저항 탐사기법의 활용성 (Application of Electrical Resistivity Measurement to an Evaluation of Saline Soil in Cropping Field)

  • 윤성원;박삼규;전현정;한경화;강성수;김명숙;김유학
    • 한국토양비료학회지
    • /
    • 제44권6호
    • /
    • pp.1035-1041
    • /
    • 2011
  • Salinity of soil under the plastic film houses in Korea is known as a significant factor to lower the crop production and to hamper the sustainable agricultural land management. In this study we propose a field monitoring technique to examine the methods applied to minimize the adverse effect of salts in soil based on the relationship between soil electrical characteristics and soil properties. Field experiments for 4 different treatments (water only, fertilizer only, DTPA only, and DTPA and fertilizer together) were conducted on soils at the plastic film house built for cultivating a cucumber plant located at Chunan-si, Chungchungnam-do in Korea. The electrical resistivity was measured by both a dipole-dipole and wenner multi-electrodes array method. After the electrical resistivity measurement we also measured the soil water content, temperature, and electrical conductivity on surface soil. The resulted image of the interpreted resistivity by the inversion technique presented a unique spatial distribution depending on the treatment, implying the effect of the different chemical components. It was also highly suspected that resistivity response changed with the nutrients level, suggesting that our proposed technique could be the effective tool for the monitoring soil water as well as nutrient during the cropping period. Especially, subsoils under DTPA treatment at 40 to 60 cm depth typically presented lower soil water accumulation comparing to subsoils under non-DTPA treatment. It is considered that DTPA resulted in increase of a root water uptake. However, our demonstrated results were mainly based on qualitative comparison. Further experiments need to be conducted to monitor temporal changes of electrical resistivity using time lapse analysis, providing that a plant root activity difference based on changes of soil water and nutrients level in time.

전기비저항탐사에 의한 산사태 지역의 지하수조사 (Geoelectrical laboratory and field studies of groundwater occurrence in a landslide area: a case study from Japan)

  • 박삼규;;;;김정호
    • 지구물리와물리탐사
    • /
    • 제8권1호
    • /
    • pp.86-91
    • /
    • 2005
  • 일본의 제 3 기 퇴적암이 분포하고 있는 대규모 산사태 지역에 있어서 계절에 따른 지하수위 변동을 파악하기 위하여 전기비저항탐사를 적용하였다. 기존의 시추조사가 수행된 NE-SW 방향으로 탐사측선을 설치하고, 동일 탐사측선에 대해서 눈이 녹은 6월과 눈이 오기전의 10월에 각각 전기비저항탐사를 실시하였다. 또한 산사태 지역에 두껍게 분포하고 있는 화산쇄설성 퇴적물 시료를 재취하여 실내에서 함수비를 인위적으로 조절하면서 전기비저항을 측정하고, 이 결과로 부터 포화상태의 화산쇄성설 퇴적물의 전기비저항이 573 ohm-m 임을 밝혔다. 이 값을 이용하여 2 회에 결쳐 실시한 산사태 지역의 전기비저항분포로부터 화산쇄설성 퇴적층 내에 분포하고 있는 지하수위를 추정할 수 있었다. 그 결과 눈이 오기 전보다 눈이 녹은 후의 융설기에 지하수위가 $1.1\~4.7m$ 정도 높은 것으로 평가되었으며, 화산쇄설성 퇴적층이 두껍게 쌓여 있는 산사태 지역의 상부에서 지하수위 변동이 큰 것으로 나타났다. 이러한 이유는 눈이 녹은 시기에 다량의 융설수가 지표로 침투되어 지하수위가 상승하고 있으며, 산사태 지역의 지하수 공급이 상부의 두꺼운 화산쇄설성 퇴적층에서 일어나고 있기 때문임을 알았다.

제체형태와 수위에 따른 전기비저항 반응 연구 (Electrical Resistivity Response Due to the Variation of Embankment Shape and Reservoir Level)

  • 오석훈
    • 지구물리와물리탐사
    • /
    • 제11권3호
    • /
    • pp.214-220
    • /
    • 2008
  • 점토질의 중심코어부에 차수 역할을 의존하는 형식의 제체에 대한 안정성 검토에 자주 적용되는 B차원 전기비저항 탐사자료의 해석 시, 제체의 심벽 구조와 수위에 따른 왜곡 양상을 모델링을 통해 검증하였다. 3차원 구조인 제체의 해석을 주로 2차원으로 수행하는 과정에서 다양한 왜곡효과가 나타났다. 제체의 재료가 수평적으로 균질한 상태에서 수위와 연관지어 분석한 결과, 양안부보다는 제체 중앙부가 비저항 단면에서 수위선을 비교적 정확히 나타내며, 양안에 존재하는 지반 등 3차원 효과로 인해 양안부로 다가가면 수위선이 깊어지는 반응을 보였다. 또한 제체의 가장 외부구조인 채움재부의 경사가 일정할 때, 코어부의 경사가 급할수록 실제 수위와 비슷한 효과를 보였다. 코어부의 경사가 비슷할 때는, 외부 채움재부의 경사가 완만할수록 실제 수위와 비슷한 효과를 보였으며, 양안에서의 3차원 효과도 덜 나타났다. 채움재부의 경사가 급하면 2차원 역산 결과, 실제수위보다 더 깊은 위치에서 수위와 관련된 저비저항대를 지시하였으며, 양안에서의 3차원 효과가 크게 나타났다.

풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법 (Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope)

  • 김재홍;박철숙;이현재;정교철
    • 지질공학
    • /
    • 제19권3호
    • /
    • pp.323-330
    • /
    • 2009
  • 전기비저항 탐사는 최근 토목설계 및 환경분야에 있어서 단층 및 파쇄대의 탐지 등에 활발히 적용되고 있다. 국내에서는 지금까지 시공실적이 없는 직경 15 m 3열의 터널 굴착공사를 시행하는 도중 터널 유입부 지반이 당초 설계와 달리 기반암선이 낮게 형성되었고, 풍화된 사면에 핵석과 파쇄대가 존재하는 것으로 나타났다. 터널 유입부 지반의 분포양상을 정확히 파악하고자 전기비저항 쌍극자탐사를 시행하였다. 전기비저항 탐사는 암석의 종류, 공극, 온도 및 지질적 순환과정 등을 통하여 외견비저항 값이 많은 변화를 보인다. 역산해석 후 전기비저항치에 의한 지반특성을 파악하였고 유한차분법을 활용한 2차원 전기비저항 구조도를 적용하여 파쇄대를 추정하였다.

Saudi Arabia 북서부의 지하수조사 (Groundwater Investigation in Northwestern Part of Saudi Arabia)

  • 한정상;정수웅
    • 물과 미래
    • /
    • 제8권2호
    • /
    • pp.30-40
    • /
    • 1975
  • Hydrogeological survey and geophysical prospecting have been carried out in Saudi Arabia for the purpose of finding groundwater in the soil and rock at the request of General trading company in Jeddah, Saudi Arabia. The surveyed area is located on $38^{\circ}-39^{\circ}$ 30' in longitude and $26^{\circ}-26^{\circ}$ 30' in latitude. The topography of this area is dominated by northwest southeast mountain range composed mostly of precambrian rocks and basalt of tertiary period. Geology is mainly composed of greenstone, granite, andesite, diorite rhyolite of pre-cambrian era and sandstone of cambrian period which are underlained by basalt and andesite of tertiary period and alluvium of quaternary unconformably. The instruments used in this investigation are TR-18B2 radioactivity unit which isjapanese patented and A.C. Terrameter, a resistivity meter manufactured by ABEM of Stockholm, Sweden. Radioactivity method has been conducted along the Alula-Khaybar road, totally 164Km by the car-borne. As a result of the above survey 16 places have been selected and these anomalies show 1.2N-1.6N compared to background of each area in intensity with width of 10-50m. Resistivity vertical profiling which made use of Schlumberger configuration method has been made over selected areas by radioactivity method to provide hydrogeological information for a water resources survey. The result of resistivity shows that good aquifers are located in the western part of surveyed area where sedimentary rock is distributed. The strata showing 10-50, ${\Omega}-m$ in resistivity are thought to be waterbearing layer. The variations in aquifer resistivity found, are thought to be due to verying clay content, which could be related to aquifer yield. It has proved impossible to detect small salinity variation in the buried aquifer by geophysics. As a result of resistivity prospecting 10 places are recommended to be drilled at the anomalies as shown attached map. yields from the proposed holes have been estimated approximately from $20m^3$ to $200m^3$ per day. Prior to drilling for groundwater, test boring using ${\c}4"$ should be drilled in order to obtain more reliable hydrogeological information for the construction of perfect wells.ells.

  • PDF

수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성 (Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content)

  • 최종혁;차응석;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.98-104
    • /
    • 2010
  • 고주파수성분을 포함하는 뇌격전류나 또는 고장전류에 대한 접지시스템의 성능을 평가하기 위해 접지저항보다는 접지임피던스에 대한 고려가 필요하다. 접지임피던스를 평가하기 위해서는 토양의 저항률과 비유전율의 주파수의존성이 규명되어야 한다. 본 논문은 3가지 다른 토양에 대하여 수분함유량에 따른 저항률과 비유전율의 주파수의존성을 나타낸다. 결론적으로 토양의 저항률은 수분함유량이 증가함에 따라서 작아지게 되고, 1[MHz]보다 낮은 주파수에서 거의 변화하지 않으며 1[MHz]이상의 주파수에서는 감소한다. 반면에 비유전율은 1[MHz]이하의 주파수에서 매우 급격하게 감소하며, 1[MHz]이상의 주파수에서는 거의 변화하지 않는 것으로 나타났다. 본 실험 결과로 부터 낙뢰 또는 개폐서지에 대한 보호를 목적으로하는 접지시스템의 설계시 토양의 저항률과 비유전율을 고려하는 것이 바람직한 것으로 밝혀졌다.

모르타르의 전기비저항 특성 (Mortar Characterization using Electrical Resistivity Method)

  • ;박삼규;송영수;김정호
    • 지구물리와물리탐사
    • /
    • 제12권2호
    • /
    • pp.215-220
    • /
    • 2009
  • 시멘트 모르타르는 고속도로 건설 및 댐 사이트의 연약지반 보강과 석회암 공동의 지반보강에 널리 사용되고 있다. 모르타르의 물리적 성질은 많은 연구 결과로부터 잘 알려져 있지만, 연약지반의 개량 정도를 평가하기 위해서 알아야 할 가장 중요한 물성 중의 하나인 전기비저항에 대해서는 극히 일부의 연구만 수행되어 있다. 이 연구에서는 물과 포틀랜드 시멘트의 배합비(0.35, 0.45, 0.50, 0.65)를 달리하여 원통형의 모르타르 시료를 제작하여, 웨너 배열 방식으로 전기비저항을 측정하였다. 그 결과 모르타르 시료의 전기비저항은 경과시간에 따라 증가하였으며, 함수비와 물/시멘트의 배합비가 증가할수록 감소하였다. 이 결과로부터 모르타르의 전기비저항과 압축강도는 밀접한 관계를 가지고 있음을 알 수 있었다.

충적대수층 조사를 위한 모래와 점토의 유도분극 특성 고찰 (IP Characteristics of Sand and Silt for Investigating the Alluvium Aquifer)

  • 최상혁;김형수;김지수
    • 지질공학
    • /
    • 제18권4호
    • /
    • pp.423-431
    • /
    • 2008
  • 충적층의 구성물질 중에서 포화된 실트 또는 점토층은 다른 층들에 비해 상대적으로 낮은 전기비저항 값을 나타낸다. 따라서 자료해석에 있어서 실트 및 점토층이 전기비저항이 작고 투수성이 높은 대수층으로 오인될 수 있다. 본 연구에서는 이러한 문제를 극복하고 충적층 내 포화된 실트 또는 점토층과 모래 또는 자갈 대수층을 구분하기 위해 충적층을 구설하고 있는 물질의 전기비저항 및 유도분극 값을 함께 측정하는 실내실험을 실시하였다. 실험결과 실트 또는 점토시료가 모래시료보다 충전성이 높게 나타났으며, 또한 모래와 점토 혼합시료에서 점토함량이 증가함에 따라 전기비저항은 감소하고 충전성은 증가하다가 다시 감소하는 경향을 보였다.

Validation of a new magnetometric survey for mapping 3D subsurface leakage paths

  • Park, DongSoon;Jessop, Mike L.
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.891-902
    • /
    • 2018
  • Techniques for more reliable detection of 3D subsurface flow paths are highly important for most water-related geotechnical projects. In this case study, a magnetometric resistivity method with a new approach and state-of-the-art technology ("Willowstick survey") was applied to the testbed dam (YD dam) site, and its applicability was validated by geotechnical investigation techniques including borehole drilling and sampling, Lugeon test, flow direction and velocity test, and seismic tomography. In addition to the magnetometric survey, a 3D electrical resistivity survey was performed independently and the results were compared and discussed. The electrical resistivity survey was effective in detecting groundwater levels, but it was limited in mapping leakage paths. On the other hand, the Willowstick magnetometric survey effectively detected geologic weaknesses (e.g., fault fracture) and potential leakage paths of the dam site foundation rocks. The results of this research are expected to be effective for water infrastructures where leakage is an important issue.