• 제목/요약/키워드: Water Resistivity

검색결과 383건 처리시간 0.031초

흙의 전기비저항 특성 (Electrical Resistivity Characteristic of Soils)

  • 박삼규;김정호;조성준;이명종;손정술
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.847-854
    • /
    • 2004
  • The resistivity of soils depends on grains size, porosity, water saturation, pore fluid resistivity, caly contents and son on. It is very important to understand the relationship between resistivity and such physical properties of soils, in order to interpret and evaluate ground conditions by using resistivity data obtained from electrical resistivity prospecting. In this paper, to study the relationship between resistivity and physical properties of soils, the resistivity of glass beads and compacted soil samples both in saturated and unsaturated conditions is measured. As the results, the resistivity of saturated soils depends mainly on porosity and clay contents, while that of unsaturated soils is sensitive to compaction conditions, and decreases with increasing water content until the optimum water condition, that is the maximum dry density. But, the relationship between resistivity and water saturation for soils is unique, being independent of compaction energy. Also, the resistivity ratio decrease with increasing water saturation, followed by no significant change of resistivity ratio over 80 percent of water saturation (the optimum water content).

  • PDF

체적함수비 및 주파수에 따른 풍화토의 전기비저항 특성 (Characteristic of electrical resistivity against volumetric water content and frequency in weathered soil)

  • 손영환;봉태호;장병욱
    • 한국농공학회논문집
    • /
    • 제50권5호
    • /
    • pp.63-72
    • /
    • 2008
  • This study was conducted to define a characteristics of Electrical Resistivity of weathered soil against volumetric water content and frequency. It is essential to analyze and understand a characteristics of the Electrical Resistivity for evaluation of soil as subsurface contaminant detection. Before the test, an effect of pore water and ion were checked using four liquids(distilled water, tap water, potassium chloride 1.8mM, and 3.7mM). As a result, the correlation between the volumetric water content and the Electrical Resistivity was estimated. The Electrical Resistivity decreases with increasing frequency and water content. Also, Electrical Resistivity could be described by an exponential function of volumetric water content with the constants.

용담댐 발전소 접지설계를 위한 대지비저항 모델링 및 접지저항 추정 (Earth Resistivity Modelling and Grounding Resistance Estimation for Yongdam Dam Power Station Grounding Design)

  • 오민환;김형수;김종득
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1188-1191
    • /
    • 1998
  • Detailed estimation of subsurface resistivity distribution and accurate estimation of actual fault current coming into the grounding system are indispensible to optimun grounding system design. Especially, it is essential for efficient grounding design to estimate subsurface resistivity distribution quantitatively and logically. Accurate estimation of subsurface resistivity distribution has an absolute influence on calculating touch voltage, step voltage and ground potential rise (GPR) which are related with grounding design standard for human safety. In this study, thirty-three electrical sounding surveys were made in Yongdam Power Station to obtain detailed subsurface resistivity distribution and the sounding data were interpreted quantitatively using multi-layered model. The results of the quantitative resistivity models were adopted practically to calculate grounding resistance values. Analytical asymptotic equations and CDEGS program were used in grounding resistance calculation and the results were compared and reviewed in the study.

  • PDF

수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구 (Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities)

  • 박삼규;김정호;서구원;원종근;김병호
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 공동학술대회 논문집
    • /
    • pp.71-76
    • /
    • 2005
  • 이 논문에서는 수리시설물을 효율적으로 유지관리하기 위하여 저수지 및 방조제제체에 계측 시스템을 설치하고, 전기비저항, SP, 수위, 간극수압 및 지중변위를 주기적으로 모니터링하여 그 결과를 분석함으로써 제체의 누수현상 및 안정성 평가를 시도하였다. 저수지 및 방조제의 체제에 설치된 전기비저항/SP 측정 시스템으로부터 측정한 각 단계별 측정 자료의 변화영상을 구하고, 변화추이를 비교분석함으로써 누수현상을 정확하게 파악할 수 있었고, 수위, 간극수압 및 지중변위량의 자료를 종합적으로 해석함으로써 제체의 안정성을 평가할 수 있었다. 이러한 결과로부터 종래의 일시적으로 실시한 물리탐사 결과로부터 누수현상을 파악하는 것보다 모니터링 계측시스템을 설치하여 운용하는 것이 수리시설물을 효율적이고 경제적으로 유지관리하기 위한 방법임을 알았다.

  • PDF

저수지의 유지관리를 위한 전기비저항모니터링 기법 응용 (Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments)

  • 박삼규;김정호;서구원
    • 지구물리와물리탐사
    • /
    • 제8권2호
    • /
    • pp.177-183
    • /
    • 2005
  • 이 논문에서는 수리시설물을 효율적으로 유지관리하기 위하여 저수지 제체에 계측 시스템을 설치하고, 전기비저항, 수위, 간극수압 및 지중변위를 주기적으로 모니터링하여 그 결과를 분석함으로써 제체의 누수현상 및 안정성 평가를 시도하였다. 저수지 제체의 댐마루에 설치된 전기비저항 측정 시스템으로부터 측정한 각 단계별 전기비저항의 변화영상을 구하고, 변화추이를 비교분석함으로써 누수현상을 정확하게 파악할 수 있었고, 수위, 간극수압 및 지중변위량의 자료를 종합적으로 해석함으로써 제체의 안정성을 평가할 수 있었다. 이러한 결과로부터 종래의 일시적으로 실시한 전기비저항탐사 결과로부터 누수현상을 파악하는 것보다 전기비저항 등 모니터링 계측시스템을 설치하여 운용하는 것이 수리시설물을 효율적이고 경제적으로 유지관리하기 위한 방법임을 알았다.

오염지반의 전기비저항치와 토성과의 상관성 연구 (A Study on the Correlation between Electrical Resistivity and Properties of Contaminated Soils)

  • 윤길림;이영남
    • 한국지반공학회지:지반
    • /
    • 제14권2호
    • /
    • pp.79-92
    • /
    • 1998
  • 실내모형실험으로 전기비저항치와 오염된 흙의 물리적 성질과의 상관관계를 규명하기 위해서 요소분석을 수행하였다. 세가지의 모래질 구에 산업폐기물매립지의 침출수를 첨가하여 모형실험에 이용했다. 혼합토의 전기비저항치는 비저항콘을 모사한 프로브를 제작하여 측정했다. 실내모형실험에서는 흙의 함수비, 간극비. 단위중량, 함수비 및 침출수의 농도를 변화시키면서 혼합토의 전기비 저항치를 계측했다. 실험결과는 흙의 종류 및 단위중량보다는 흙의 함수비, 간극수의 전도성이 전기비저항치에 큰 영향를 미치고 있음을 알 수 있었다.

  • PDF

오염토양의 전기 비저항치 변화 연구 (Electrical Resistivity Variations of Contaminated Soils)

  • 윤길림;이용길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

사질토 간극수의 이온 성분들에 따른 전기비저항값의 변화 (Variation of the Electrical Resistivity with ion Components of Pore Water in the Sand)

  • 유찬;윤춘경;이영남;이용길
    • 한국지반공학회논문집
    • /
    • 제15권1호
    • /
    • pp.185-196
    • /
    • 1999
  • 실내실험에 의하여 사질토 간극수의 이온 성분들사이 관계를 규명하기 위하여 흙의 비저항측정 상자와 STING-Rl비저항 측정기를 이용하여 분석을 수행하였다. 실험은 이온성분들의 농도를 변화시키면서 실시하였다. 또한 2~3가지 성분을 혼합한 경우에 대해서도 비저항값의 변화를 측정하였다. 실험결과는 성분중에서 비소(As)의 비저항값의 감소가 가장 컸으며, 나머지 성분들은 일반성분들과 큰 차이를 보이지는 않았다. 또한 혼합성분의 경우에는 비저항값의 범위가 간극수에 포함된 성분들의 비저항값에 따라 달라지는 것으로 나타났다.

  • PDF

Use of Two Dimensional Electrical Resistivity Tomography to Identify Soil Water Dynamics and the Effective Plant Root Zone

  • Yoon, Sung-Won;Zhang, Yong-Seon;Han, Kyung-Hwa;Jo, Hee-Rae;Ha, Sang-Keun;Park, Sam-Kyeu;Sonn, Yeon-Kyu
    • 한국토양비료학회지
    • /
    • 제45권3호
    • /
    • pp.353-359
    • /
    • 2012
  • The identification of effective root zone would clarify dynamics of plant available water and soil water balance. Using the relationship between soil properties and electrical resistivity (ER) the purpose of this research is to identify soil zone affected by a plant root activity using electrical resistivity tomography (ERT) technique. Four plastic containers were prepared for two different soil textures (clay and sandy loam) and one container for each texture was selected for planting four corn seedlings (Zea mays L.) and the others were prepared for the blank. For ERT monitoring, we prepared 0.8 m plastic sticks with 17 electrodes installed with 5 cm space. The Ministing (AGI Inc., Texas) instrument for electrical resistivity measurement and semi-auto converter of electrode arrangement were set up for dipole-dipole array. During 2 months of the corns growing, ERT monitoring was made 3 to 4 days after the irrigation practice. Despite of the same amount water supplied into soils, two textures showed very different apparent resistivity values due to different clay content. The apparent electrical resistivity is consistently lower in clay loam comparing to sandy loam soil implying that plant root does not significantly alter the overall trend of resistivity. When plant root system, however, is active both soils with plants showed 2-7 times higher electrical resistivity and higher coefficient variation than soils without plant, implying the effect of root system on the resistivity, in which may caused by. This result suggests plant root activities regulating the soil water dynamics mainly control the variation of electrical resistivity over soil textural difference. Therefore the identification of water uptake zone would highly be correlated to plant root activities, thus ERT will be feasible approach to identify spatial characteristics of a plant root activity.

석탄 화력발전소에서 발생되는 석탄회의 수분함유량 및 온도에 따른 비저항성 특성 연구 (A Study of Fly Ash Resistivity Characteristics Generated from the Coal Fired Power Plant as a Function of Water Concentration and Temperature)

  • 구재현;이정언;이재근
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.526-532
    • /
    • 2000
  • Recent studies have been directed toward obtaining a better understanding of the application of electrostatic precipitators to collect fly ash particles produced in a coal-fired power plant. Electrical resistivity can be described as the resistance of the collected dust layer to the flow of electrical current and is an important property for the collection efficiency in the electrostatic precipitator. In this paper, fly ash resistivity as a function of temperature up to $450^{\circ}C$ has been experimentally investigated using the resistivity meter consisted of the movable electrode, dust cup, and furnace. Resistivity was found to increase with increased temperature up to $200^{\circ}C$ due to the reduction of water concentration and then gradually decrease with increased temperature due to the activation of electrons. As the resistivity of fly ash in the flue gas temperature of $150^{\circ}C$ was measured >$10^{10}$ ohm cm, the efficiency of fly ash removal in the electrostatic precipitator might be expected to be low due to back-corona phenomenon. Flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash as required.