Electrical Resistivity Characteristic of Soils (흙의 전기비저항 특성)

  • Park, Sam-Gyu;Kim, Jung-Ho;Cho, Seong-Jun;Yi, Myeong-Jong;Son, Jeong-Sul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.847-854
    • /
    • 2004
  • The resistivity of soils depends on grains size, porosity, water saturation, pore fluid resistivity, caly contents and son on. It is very important to understand the relationship between resistivity and such physical properties of soils, in order to interpret and evaluate ground conditions by using resistivity data obtained from electrical resistivity prospecting. In this paper, to study the relationship between resistivity and physical properties of soils, the resistivity of glass beads and compacted soil samples both in saturated and unsaturated conditions is measured. As the results, the resistivity of saturated soils depends mainly on porosity and clay contents, while that of unsaturated soils is sensitive to compaction conditions, and decreases with increasing water content until the optimum water condition, that is the maximum dry density. But, the relationship between resistivity and water saturation for soils is unique, being independent of compaction energy. Also, the resistivity ratio decrease with increasing water saturation, followed by no significant change of resistivity ratio over 80 percent of water saturation (the optimum water content).

  • PDF

Characteristic of electrical resistivity against volumetric water content and frequency in weathered soil (체적함수비 및 주파수에 따른 풍화토의 전기비저항 특성)

  • Son, Young-Hwan;Bong, Tae-Ho;Chang, Pyoung-Wuck
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.5
    • /
    • pp.63-72
    • /
    • 2008
  • This study was conducted to define a characteristics of Electrical Resistivity of weathered soil against volumetric water content and frequency. It is essential to analyze and understand a characteristics of the Electrical Resistivity for evaluation of soil as subsurface contaminant detection. Before the test, an effect of pore water and ion were checked using four liquids(distilled water, tap water, potassium chloride 1.8mM, and 3.7mM). As a result, the correlation between the volumetric water content and the Electrical Resistivity was estimated. The Electrical Resistivity decreases with increasing frequency and water content. Also, Electrical Resistivity could be described by an exponential function of volumetric water content with the constants.

Earth Resistivity Modelling and Grounding Resistance Estimation for Yongdam Dam Power Station Grounding Design (용담댐 발전소 접지설계를 위한 대지비저항 모델링 및 접지저항 추정)

  • Oh, Min-Hwan;Kim, Hyoung-Soo;Kim, Jong-Deug
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1188-1191
    • /
    • 1998
  • Detailed estimation of subsurface resistivity distribution and accurate estimation of actual fault current coming into the grounding system are indispensible to optimun grounding system design. Especially, it is essential for efficient grounding design to estimate subsurface resistivity distribution quantitatively and logically. Accurate estimation of subsurface resistivity distribution has an absolute influence on calculating touch voltage, step voltage and ground potential rise (GPR) which are related with grounding design standard for human safety. In this study, thirty-three electrical sounding surveys were made in Yongdam Power Station to obtain detailed subsurface resistivity distribution and the sounding data were interpreted quantitatively using multi-layered model. The results of the quantitative resistivity models were adopted practically to calculate grounding resistance values. Analytical asymptotic equations and CDEGS program were used in grounding resistance calculation and the results were compared and reviewed in the study.

  • PDF

Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities (수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구)

  • Park, Sam-Gyu;Kim, Jung-Ho;Seo, Goo-Won;Won, Jong-Geun;Kim, Byung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.71-76
    • /
    • 2005
  • The subject of this paper is research into the application of resistivity/SP monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity/SP measurement, inclinometer, piezometer, and water gauge at an embankment, Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and SP variations that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variations of resistivity and SP at the embankment were provided from the monitoring data and we could accurately locate the portions of which resistivities and SP have sharply changed, Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity and SP, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity and SP data would be much more preferable to performing the just one-time measurements.

  • PDF

Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments (저수지의 유지관리를 위한 전기비저항모니터링 기법 응용)

  • Park Sam Gyu;Kim Jung-Ho;Seo Goo Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The subject of this paper is research into the application of electrical resistivity monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity measurement, inclinometer, piezometer, and water gauge at an embankment. Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variant images of electrical resistivity at the embankment were provided from the monitoring data and we could accurately locate the portion of which resistivities have sharply changed. Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity data and hydrological data would be much more preferable to performing the just one-time measurements.

A Study on the Correlation between Electrical Resistivity and Properties of Contaminated Soils (오염지반의 전기비저항치와 토성과의 상관성 연구)

  • 윤길림;이영남
    • Geotechnical Engineering
    • /
    • v.14 no.2
    • /
    • pp.79-92
    • /
    • 1998
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and properties of contaminated soils. Three kinds of sandy soils sampled and leachate from an industrial waste landfill were mired to model the contaminated soils. Electrical resistivity of soils was measured by using a simulated resistivity cone penetrometer probe. In the experiments. the electrical resistivity was observed by changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

Electrical Resistivity Variations of Contaminated Soils (오염토양의 전기 비저항치 변화 연구)

  • 윤길림;이용길
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

Variation of the Electrical Resistivity with ion Components of Pore Water in the Sand (사질토 간극수의 이온 성분들에 따른 전기비저항값의 변화)

  • Yu, Chan;Yoon, Chun-Gyeong;Lee, Young-Nam;Lee, Yong-Gil
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.185-196
    • /
    • 1999
  • A laboratory experiment was performed to examine the relationship between resistivity and ionic components in the pore water of a sand by using soil resistivity test box and STING-Rl. The resistivity measurement was performed with the concentration changes of ionic components. Also, the resistivity change was evaluated for multiple components. The results showed that the resistivity of Arsenic was less than other heavy metals. In the case of complex components, resistivity ranges depended on the resistivity of components existed in the pore water.

  • PDF

Use of Two Dimensional Electrical Resistivity Tomography to Identify Soil Water Dynamics and the Effective Plant Root Zone

  • Yoon, Sung-Won;Zhang, Yong-Seon;Han, Kyung-Hwa;Jo, Hee-Rae;Ha, Sang-Keun;Park, Sam-Kyeu;Sonn, Yeon-Kyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.3
    • /
    • pp.353-359
    • /
    • 2012
  • The identification of effective root zone would clarify dynamics of plant available water and soil water balance. Using the relationship between soil properties and electrical resistivity (ER) the purpose of this research is to identify soil zone affected by a plant root activity using electrical resistivity tomography (ERT) technique. Four plastic containers were prepared for two different soil textures (clay and sandy loam) and one container for each texture was selected for planting four corn seedlings (Zea mays L.) and the others were prepared for the blank. For ERT monitoring, we prepared 0.8 m plastic sticks with 17 electrodes installed with 5 cm space. The Ministing (AGI Inc., Texas) instrument for electrical resistivity measurement and semi-auto converter of electrode arrangement were set up for dipole-dipole array. During 2 months of the corns growing, ERT monitoring was made 3 to 4 days after the irrigation practice. Despite of the same amount water supplied into soils, two textures showed very different apparent resistivity values due to different clay content. The apparent electrical resistivity is consistently lower in clay loam comparing to sandy loam soil implying that plant root does not significantly alter the overall trend of resistivity. When plant root system, however, is active both soils with plants showed 2-7 times higher electrical resistivity and higher coefficient variation than soils without plant, implying the effect of root system on the resistivity, in which may caused by. This result suggests plant root activities regulating the soil water dynamics mainly control the variation of electrical resistivity over soil textural difference. Therefore the identification of water uptake zone would highly be correlated to plant root activities, thus ERT will be feasible approach to identify spatial characteristics of a plant root activity.

A Study of Fly Ash Resistivity Characteristics Generated from the Coal Fired Power Plant as a Function of Water Concentration and Temperature (석탄 화력발전소에서 발생되는 석탄회의 수분함유량 및 온도에 따른 비저항성 특성 연구)

  • Ku, Jae-Hyun;Lee, Jung-Eun;Lee, Jae-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.526-532
    • /
    • 2000
  • Recent studies have been directed toward obtaining a better understanding of the application of electrostatic precipitators to collect fly ash particles produced in a coal-fired power plant. Electrical resistivity can be described as the resistance of the collected dust layer to the flow of electrical current and is an important property for the collection efficiency in the electrostatic precipitator. In this paper, fly ash resistivity as a function of temperature up to $450^{\circ}C$ has been experimentally investigated using the resistivity meter consisted of the movable electrode, dust cup, and furnace. Resistivity was found to increase with increased temperature up to $200^{\circ}C$ due to the reduction of water concentration and then gradually decrease with increased temperature due to the activation of electrons. As the resistivity of fly ash in the flue gas temperature of $150^{\circ}C$ was measured >$10^{10}$ ohm cm, the efficiency of fly ash removal in the electrostatic precipitator might be expected to be low due to back-corona phenomenon. Flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash as required.